Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aging analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Mineralogical Analysis of the Oppia Quadrangle of Asteroid (4) Vesta: Evidence for Occurrence of Moderate-Reflectance Hydrated Minerals

Quadrangle Av-10 'Oppia' is one of five quadrangles that cover the equatorial region of asteroid (4) Vesta. This quadrangle is notable for the broad, spectrally distinct ejecta that extend south of the Oppia crater. These ejecta exhibit the steepest ('reddest') visible spectral slope observed across the asteroid and have distinct color properties as seen in multispectral composite images. Compared to previous works that focused on the composition and nature of unusual ('orange') ejecta found on Vesta, here we take into account a broader area that includes several features of interest, with an emphasis on mineralogy as inferred from data obtained by Dawn's Visible InfraRed mapping spectrometer (VIR). Our analysis shows that the older northern and northeastern part of Av-10 is dominated by howardite-like material, while the younger southwestern part, including Oppia and its ejecta blanket, has a markedly eucritic mineralogy. The association of the mineralogical information with the geologic and topographic contexts allows for the establishment of relationships between the age of the main formations observed in this quadrangle and their composition. A major point of interest in the Oppia quadrangle is the spectral signature of hydrous material seen at the local scale. This material can be mapped by using high-resolution VIR data, combined with multispectral image products from the Dawn Framing Camera (FC) so as to enable a clear correlation with specific geologic features. Hydrated mineral phases studied previously on Vesta generally correlate with low-albedo material delivered by carbonaceous asteroids. However, our analysis shows that the strongest OH signature in Av-10 is found in a unit west of Oppia, previously mapped as 'light mantle material' and showing moderate reflectance and a red visible slope. With the available data we cannot yet assess the presence of water in this material. However, we offer a possible explanation for its origin.

Asteroids↗

Explosives for Lunar Seismic Profiling Experiment (LSPE)

Explosive charges of various sizes were investigated for use in lunar seismic studies. Program logistics, and the specifications for procurement of bulk explosives are described. The differential analysis, thermal properties, and detonation velocity measurements on HNS/Teflon 7C 90/10 are reported along with the field tests of the hardware. It is concluded that nearly all large explosive charges crack after fabrication, from aging or thermal shock. The cracks do not affect the safety, or reliability of the explosives.

Source record↗

The effect of diffusive hydrogen segregation on fracture of polycrystalline nickel

Hydrogen embrittlement of polycrystalline nickel was studied under conditions which allowed the diffusion and segregation of hydrogen to grain boundaries to be controlled. It was shown that even at high solute concentrations of hydrogen, the fracture mode was ductile shear rupture, if transport of hydrogen to the grain boundaries was not allowed. As the amount of hydrogen segregation to the grain boundaries was increased, the fracture mode became increasingly intergranular. Analysis of the temperature dependence of this transition from ductile rupture to transgranular fracture yields a hydrogen segregation enthalpy of 11.6 kJ/mol. The transition in the fracture mode was also observed at a constant aging temperature by increasing the solute hydrogen concentration. The kinetics of this fracture transition suggest that the hydrogen segregation layer extends about 35 nm from the grain boundary. It is suggested that the fracture mechanism is a softening of the material in this segregation region due to the high hydrogen concentration.

Lassila, D. H.↗

Passive films on magnesium anodes in primary batteries

The characteristics of the passive films over Mg anodes, which essentially govern the voltage delay of the latter, have been determined nondestructively from an analysis of the transient and steady-state response of the electrode potential to low amplitude galvanostatic polarization under various experimental conditions viz., with different corrosion inhibitor coatings on Mg, after various periods of ageing of anode in solutions containing corrosion inhibitors, at various low temperatures etc. Using these parameters, the kinetics of film build-up or dissolution under these conditions have been monitored. The morphology of the anode film has been verified with scanning electron microscopy. Similar transients at low temperatures point out a steep rise in the film resistivity which is essentially responsible for the severe voltage delay. Finally, possible application of this technique in secondary Li batteries to improve cycling characteristics of the Li anode has been pointed out.

Ratnakumar, B. V.↗

Flexor bias of joint position in humans during spaceflight

The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

STS-78 Shuttle Project↗

Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies

The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

Non-NASA Center↗

Evidence of SV40 infections in hospitalized children

Simian virus 40 (SV40) is known to have contaminated poliovirus vaccines used between 1955 and 1963. Accumulating reports have described the presence of SV40 DNA in human tumors and normal tissues, although the significance of human infections by SV40 is unknown. We investigated whether unselected hospitalized children had evidence of SV40 infections and whether any clinical correlations were apparent. Serum samples were examined for SV40 neutralizing antibody using a specific plaque reduction test; of 337 samples tested, 20 (5.9%) had antibody to SV40. Seropositivity increased with age and was significantly associated with kidney transplants (6 of 15 [40%] positive, P < .001). Many of the antibody-positive patients had impaired immune systems. Molecular assays (polymerase chain reaction and DNA sequence analysis) on archival tissue specimens confirmed the presence of SV40 DNA in 4 of the antibody-positive patients. This study, using 2 independent assays, shows the presence of SV40 infections in children born after 1980. We conclude that SV40 causes natural infections in humans.

NASA Discipline Regulatory Physiology↗

High Resolution ECG for Evaluation of QT Interval Variability during Exposure to Acute Hypoxia

Ventricular repolarization instability as quantified by the index of QT interval variability (QTVI) is one of the best predictors for risk of malignant ventricular arrhythmias and sudden cardiac death. Because it is difficult to appropriately monitor early signs of organ dysfunction at high altitude, we investigated whether high resolution advanced ECG (HR-ECG) analysis might be helpful as a non-invasive and easy-to-use tool for evaluating the risk of cardiac arrhythmias during exposure to acute hypoxia. 19 non-acclimatized healthy trained alpinists (age 37, 8 plus or minus 4,7 years) participated in the study. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position breathing room air and then after breathing 12.5% oxygen for 30 min. For beat-to-beat RR and QT variability, the program of Starc was utilized to derive standard time domain measures such as root mean square of the successive interval difference (rMSSD) of RRV and QTV, the corrected QT interval (QTc) and the QTVI in lead II. Changes were evaluated with paired-samples t-test with p-values less than 0.05 considered statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with p = 0.000 and p = 0.005, respectively. Significant increases were found in both the rMSSDQT and the QTVI in lead II, with p = 0.002 and p = 0.003, respectively. There was no change in QTc interval length (p = non significant). QT variability parameters may be useful for evaluating changes in ventricular repolarization caused by hypoxia. These changes might be driven by increases in sympathetic nervous system activity at ventricular level.

Zupet, P.↗

Forty-Year Calibrated Record of Earth-Surface Reflected Radiance from Landsat: A Review

Sensors on Landsat satellites have been collecting images of the Earth's surface for nearly 40 years. These images have been invaluable for characterizing and detecting changes in the land cover and land use of the world. Although initially conceived as primarily picture generating sensors, even the early sensors were radiometrically calibrated and spectrally characterized prior to launch and incorporated some capabilities to monitor their radiometric calibration once on orbit. Recently, as the focus of studies has shifted to monitoring Earth surface parameters over significant periods of time, serious attention has been focused toward bringing the data from all these sensors onto a common radiometric scale over this 40-year period. This effort started with the most recent systems and then was extended back in time. Landsat-7 ETM+, the best-characterized sensor of the series prior to launch and once on orbit, and the most stable system to date, was chosen to serve as the reference. The Landsat-7 project was the first of the series to build an image assessment system into its ground system, allowing systematic characterization of its sensors and data. Second, the Landsat-5 TM (still operating at the time of the Landsat-7 launch and continues to operate) calibration history was reconstructed based on its internal calibrator, vicarious calibrations, pseudo-invariant sites and a tie to Landsat-7 ETM+ at the time of the commissioning of Landsat-7. This process was performed in two iterations: the earlier one relied primarily on the TM internal calibrator. When this was found to have some deficiencies, a revised calibration was based more on pseudo-invariant sites, though the internal calibrator was still used to establish the short-term variations in response due to icing build up on the cold focal plane. As time progressed, a capability to monitor the Landsat-5 TM was added to the image assessment system. The Landsat-4 TM, which operated from 1982-1992, was the third system to which the radiometric scale was extended. The limited and broken use of the Landsat-4 TM made this analysis more difficult. Eight-day separated image pairs from Landsat-5 combined with analysis of pseudo invariant sites established this history. The fourth and most challenging effort was making the Landsat-1 to -5 MSS sensors' data internally radiometrically consistent. This effort was particularly complicated by the age of the MSS data, varying formats and processing levels in the archive, limited datasets, and limited documentation available. Ultimately, pseudo-invariant sites were identified in North America and used for this effort. Note that most of the Landsat-MSS archived data had already been calibrated using the MSS internal calibrators, so this processing was imbedded in the result. The final effort was developing an absolute scale for Landsat MSS similar to what was already established for the "TM" sensors. This was accomplished by using simultaneous data from Landsat-5 MSS and Landsat-5 TM, accounting for spectral differences between the sensors using EO-1 Hyperion data. The recalibrated history of the Landsat data and implications to users are discussed. The key result from this work is a consistently calibrated Landsat data archive that spans nearly 40 years with total uncertainties on the order of 10% or less for most sensors and bands.

Markham, Brian↗

Can Terrestrial Microbes Grow on Mars?

The theme for AbSciCon 2012 is "Exploring Life: Past and Present, Near and Far." The conference will address our current understanding of life - from processes at the molecular level to those which operate at planetary scales. Studying these aspects of life on Earth provides an essential platform from which to examine the potential for life on other worlds, both within our solar system and beyond. Mars exhibits a variety of extreme environments characterized by high UV and ionizing radiation flux, low pressure anoxic atmosphere, scarce or absent liquid water, extreme low temperatures, etc. The ability of terrestrial microorganisms to survive and adapt to the Mars environment has profound implications for astrobiology, planetary protection, and Mars life detection missions. At the NASA Ames Synthetic Biology Initiative, we believe that synthetic biology has the potential to revolutionize human space exploration. As such, the initiative is dedicated to applying the tools and techniques of synthetic biology to space exploration and astrobiology. Biological solutions will be invaluable for space exploration because they are not resource intensive, and they are versatile and self-renewing. An understanding of how to work with DNA in an unfavorable environment is paramount to utilizing biological tools on space missions. Furthermore, the ability to adjust life to the parameters of Mars is vital both to discovering what life on Mars might look like, and to using biological tools under such conditions. As a first step, we need an energy-efficient, low cost means of transporting, storing, and protecting genomic DNA, DNA parts, and whole microbial strains. Our goal is to develop and demonstrate viable and superior alternatives to standard DNA storage methods, which can be optimized to the conditions of space exploration, using synthetic biology as a tool. This includes protocols and kit designs for easy and repeatable DNA and strain recovery from protective storage conditions. We are constructing newly engineered genetic parts for different valuable host organisms, designed to increased long-term survival and functional retention. These methods should be applied for DNA and strain storage and transportation. In parallel, we seek inspiration from natural organisms that have developed means for survival in extreme environmental conditions. We are utilizing novel techniques for analysis of lipid biomarkers in the Antarctic Dry Valleys in order to identify resident microbes in the Antarctic soil and permafrost, as well as biomarker fossils of organisms that survived in the valleys in ages past. Through the identification of these life forms, we hope to understand and draw on new biological tools and strategies for synthetic biological applications on Mars.

Rothschild, Lynn↗

Altered fractal dynamics of gait: reduced stride-interval correlations with aging and Huntington's disease

Fluctuations in the duration of the gait cycle (the stride interval) display fractal dynamics and long-range correlations in healthy young adults. We hypothesized that these stride-interval correlations would be altered by changes in neurological function associated with aging and certain disease states. To test this hypothesis, we compared the stride-interval time series of 1) healthy elderly subjects and young controls and of 2) subjects with Huntington's disease and healthy controls. Using detrended fluctuation analysis we computed alpha, a measure of the degree to which one stride interval is correlated with previous and subsequent intervals over different time scales. The scaling exponent alpha was significantly lower in elderly subjects compared with young subjects (elderly: 0.68 +/- 0.14; young: 0.87 +/- 0.15; P < 0.003). The scaling exponent alpha was also smaller in the subjects with Huntington's disease compared with disease-free controls (Huntington's disease: 0.60 +/- 0.24; controls: 0.88 +/-0.17; P < 0.005). Moreover, alpha was linearly related to degree of functional impairment in subjects with Huntington's disease (r = 0.78, P < 0.0005). These findings demonstrate that strike-interval fluctuations are more random (i.e., less correlated) in elderly subjects and in subjects with Huntington's disease. Abnormal alterations in the fractal properties of gait dynamics are apparently associated with changes in central nervous system control.

NASA Discipline Cardiopulmonary↗

Oscillations of red dwarfs in evolved low-mass binaries with neutron stars

We investigate a novel aspect of a problem related to the properties of low-mass binaries (LMBs) with millisecond pulsars: the pulsations of the red dwarf (donor) companion of the neutron star (NS). The illumination of the donor star by the pulsar's high-energy nonthermal radiation and relativistic wind may substantially affect its structure. We present a quantitative analysis of the oscillation spectrum of a red dwarf which has evolved in an LMB and has undergone the stage of evaporation. We calculate the p- and g-modes for red dwarfs with masses in the interval (0.2-0.6) stellar mass. For comparison, similar calculations are presented for zero age main-sequence (ZAMS) stars of the same masses. For less massive donor stars (approximately 0.2 stellar mass) the oscillation spectrum becomes quantitatively different from that of their ZAMS counterparts. The differnce is due to the fact that a ZAMS star of 0.2 stellar mass is fully convective, while the donor star in an LMB is expected to be far from thermal equilibrium and not fully convective. As a result, in contrast to a low-mass ZAMS star, a red dwarf of the same mass in an LMB allows the existence of g-modes. We also consider tidally forced g-modes, and perform a linear analysis of these oscillations for different degrees of nonsynchronism between the orbital and spin rotation of the red dwarf component. We demonstrate the existence of a series of reasonances for the low-order g-modes which may occur in LMBs at a late stage of their evolution. We discuss the possibility that these oscillations may trigger Roche lobe overflow and sudden mass loss by the donor star. Further implications of this effect for gamma- and X-ray burst phenomena are outlined.

Sarna, Marek J.↗

Rapid and precise analysis for calcium in blood serum

Differential absorption spectrophotometric technique, using murexide, gives a highly precise analysis of calcium in volumes of blood serum as small as 0.01 ml. The method of additions and proper timing allows compensation to be made for fading, variation in type of serum or plasma, and aging of the specimen.

Holtzman, R. B.↗

Long Term Aging of Elastomers: Chemorheology of Viton B Fluorocarbon Elastomer

The continuation of a study to ascertain the nature, extent, and the rate of chemical changes that take place in certain selected elastomers is reported. Under discussion is Viton B, regarded as a temperature and fuel resistant fluorocarbon rubber. The kinetic analysis of the chemical stress relaxation, and infrared and gel permeation chromatography analysis results are discussed.

Kalfayan, S. H.↗

Problems in the use of interference filters for spectrophotometric determination of total ozone

An analysis of the use of ultraviolet narrow-band interference filters for total ozone determination is given with reference to the New Zealand filter spectrophotometer under the headings of filter monochromaticity, temperature dependence, orientation dependence, aging, and specification tolerances and nonuniformity. Quantitative details of each problem are given, together with the means used to overcome them in the New Zealand instrument. The tuning of the instrument's filter center wavelengths to a common set of values by tilting the filters is also described, along with a simple calibration method used to adjust and set these center wavelengths.

Basher, R. E.↗

Shock disturbance of the I-Xe system

Three separate samples of the meteorite Bjurbole were artificially shocked at pressures of 70 kb, 200 kb, and 400 kb. Analysis of xenon released in stepwise heating shows that the I-Xe system of the 400 kb sample is substantially altered by the shock loading, and it is no longer possible to infer an age or trapped xenon composition for that sample. The 200-kb and 70-kb samples display isotopic structures progressively less altered demonstrating the gradations in shock disturbance likely to be found in natural systems. Interpretations of the I-Xe and Ar-40-Ar-39 systems for several naturally shocked meteorites are also presented. New data for Arapahoe do not confirm the previously reported age and trapped xenon composition, demonstrating instead that its I-Xe structure has been strongly disturbed by shock.

Caffee, M. W.↗

The thermodynamic case for a water-rich Mars

The geologic evidence for a water-rich Mars has been reviewed, and it has been concluded that it is consistent with an outgassed inventory of H2O equivalent to global ocean 0.5-1 km deep. The most persuasive support for this conclusion comes from the martian outflow channels, whose distribution, size, and range of ages, suggests that a significant body of ground water was present on Mars throughout much of its geologic history. In this abstract, the thermodynamic implications of the outflow channels are considered. The results of this analysis suggest that if the outflow channels were carved by the discharge of ground water in diffusive and thermodynamic equilibrium with the overlying frozen crust, it implies a minimum planetary inventory of water in excess of 300 m. However, if the global inventory of ground water on Mars at the time of outflow channel formation was as high as the 500 m estimate of other researchers, then the total inventory of water on Mars could well exceed 750 m.

Clifford, Stephen M.↗

Accelerated Aging Experiments for Prognostics of Damage Growth in Composite Materials

Composite structures are gaining importance for use in the aerospace industry. Compared to metallic structures their behavior is less well understood. This lack of understanding may pose constraints on their use. One possible way to deal with some of the risks associated with potential failure is to perform in-situ monitoring to detect precursors of failures. Prognostic algorithms can be used to predict impending failures. They require large amounts of training data to build and tune damage model for making useful predictions. One of the key aspects is to get confirmatory feedback from data as damage progresses. These kinds of data are rarely available from actual systems. The next possible resource to collect such data is an accelerated aging platform. To that end this paper describes a fatigue cycling experiment with the goal to stress carbon-carbon composite coupons with various layups. Piezoelectric disc sensors were used to periodically interrogate the system. Analysis showed distinct differences in the signatures of growing failures between data collected at conditions. Periodic X-radiographs were taken to assess the damage ground truth. Results after signal processing showed clear trends of damage growth that were correlated to damage assessed from the X-ray images.

composites↗