Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Anode heat transfer in a constricted tube arc.

The complex energy exchange mechanisms occurring on the most severely heated component of an arc constrictor, the anode, have been investigated. Measurements performed to determine the anode heat flux for a cascade, atmospheric argon arc of the Maecker type are described. The results are used to check the validity of an existing anode heat transfer model.

Lukens, L. A.↗

Field-aligned particle currents near an auroral arc.

A Nike-Tomahawk rocket equipped to measure electric and magnetic fields and charged particles from a few eV to several hundred keV energy was flown into an auroral band on April 11, 1970. The purpose of this flight was to obtain evidence of the low-energy electrons and protons that constitute a field-aligned sheet current, and also to obtain the magnetic signature of such a current and the electric field in and near the auroral-arc electric current system. Particular attention was given to a sudden increase in the field-aligned current associated with a prior sudden increase in the electric field and a sudden change in the magnetic field, all occurring near the edge of a visual auroral arc. Data obtained are discussed and analyzed; they present an important contribution to the problem of mapping of atmospheric auroral phenomena to the magnetospheric equatorial plane.

Choy, L. W.↗

Cross-flow blowing of a two-dimensional stationary arc.

It is demonstrated in an analysis that the electrons emitted from the cathode undergo collisions with the heavy particles and are deflected in the flow direction by the component of a collisional force associated with the relative difference in flow velocities between electrons and heavy particles. The resultant motion of the electrons describing the arc is thus caused by a combined action of the collisional force that results from the externally applied electric field. An expression is given which enables computation of the arc shape to be made provided the velocity distribution of the cross-flow and the distribution of the externally applied electric field are prescribed.

Bose, T. K.↗

A model following variable stability system for the NASA ARC X-14B.

A description of the basic design concept, hardware design, and flight evaluation of a Variable Stability System (VSS) installed on the NASA ARC X-14B is presented. The NASA ARC X-14B is a twin-engine, single-seated VTOL aircraft. The VSS is unique in that it employs a general purpose airborne digital computer as an integral part of the hybrid model following flight control system. The system design, analysis and testing phases are discussed in the paper from the application of optimal control techniques in the preliminary design of the system, through the flight demonstration of the VSS hardware.

Gallagher, J. T.↗

Exhaust plume structure in a quasi-steady MPD arc.

Results of spectroscopic and photographic investigations revealing a complex azimuthal species structure in the exhaust plume of a quasi-steady argon MPD arc. The features of the plume structure are found to be dependent on the arc current and mass flow rate. Time-resolved spectroscopic velocity measurements, obtained by a scanning Fabry-Perot interferometer, indicate argon ion jet velocities of 16,500 m/sec at a current of 16 kA and a matched mass flow of 6 g/sec. It is found that nearly half this velocity is attained in an acceleration region well downstream of the region of significant electromagnetic interaction. Temperature measurements suggest that simple expansion processes in the argon jets cannot fully explain the observed acceleration. It is possible that a transfer of momentum from the ablated core flow to the argon jets may contribute to the high argon velocities.

Bruckner, A. P.↗

Design and performance of the Ames electric-arc shock tunnel

A high enthalpy shock tunnel using arc-heated helium as the driver gas was designed for gas dynamic research at total stream energies from 7,000 to 35,000 j/g. The arc driver was found to be a relatively efficient energy converter. Tailored shock Mach numbers from 11.5 to 14.6 in air were demonstrated. A nozzle calibration with a total stream enthalpy of 18,600 j/g of air gave test times of 1.5 to 2.0 m sec at flow Mach numbers from 16 to 24.

Reller, J. O., Jr.↗

Casting copper to tungsten for high power arc lamp cathodes

A method for making 400-kW arc lamp cathodes is described. The cathodes are made by casting a 1.75-in. diameter copper body onto a thoriated tungsten insert. The addition of 0.5-percent nickel to the copper prevents voids from forming at the copper-tungsten interface. Cathodes made by this process have withstood more than 110 hours of operation in a 400-kW arc lamp.

Will, H. A.↗

Experimental investigation of a wall stablized arc with comparisons to theoretical predictions

A wall-stabilized, constricted-arc heater was investigated by extensive measurements of pressure, voltage, and wall heat flux at different axial locations along the constrictor. Radial temperature profiles were measured at one axial location by the radiance of a single line method and also by the continuum radiance at a wavelength of 4955 A. The arc heater with an inside diameter of 2.37 cm and a constrictor length of 42 cm was operated with nitrogen flow rate from about 2 to 10 g/sec, and are currents from 400 to 1200 amperes. Based on a literature search, two different digital computer programs were selected which were used to predict the pertinent parameters by numerical solutions to the governing differential equations. The program selections were based on completeness and availability. In general the predictions were adequate when laminar flow was assumed, and the greatest difficulty was encountered in the predictions of wall heat flux. The results of the measurements are shown in graphical form, along with the theoretical predictions from both computer programs.

Wells, W. L.↗

Reflecting Solutions of High Order Elliptic Differential Equations in Two Independent Variables Across Analytic Arcs

Consideration is given specifically to sixth order elliptic partial differential equations in two independent real variables x, y such that the coefficients of the highest order terms are real constants. It is assumed that the differential operator has distinct characteristics and that it can be factored as a product of second order operators. By analytically continuing into the complex domain and using the complex characteristic coordinates of the differential equation, it is shown that its solutions, u, may be reflected across analytic arcs on which u satisfies certain analytic boundary conditions. Moreover, a method is given whereby one can determine a region into which the solution is extensible. It is seen that this region of reflection is dependent on the original domain of difinition of the solution, the arc and the coefficients of the highest order terms of the equation and not on any sufficiently small quantities; i.e., the reflection is global in nature. The method employed may be applied to similar differential equations of order 2n.

Carleton, O.↗

Cyclic arc plasma tests of RSI materials using a preheater

The results of a test program are reported in which a preheater was used with an arc plasma stream to study the thermal response of samples of candidate reusable surface insulation materials for the space shuttle. The preheater simulated the shuttle temperature history during the first and last portions of the test cycle, which could not be simulated by the air arc plasma flow. Pre- and post-test data taken for each of the materials included magnified views, optical properties, and chemical analyses. The test results indicate that the mullite base samples experience higher surface temperatures than the other materials at heating rates greater than 225 kw/sq m. The ceramic fibrous mullite and silica coatings show noncatalytic wall behavior. Internal temperature response data for the materials are compared and correlated with analytical predictions.

Stewart, D. A.↗

Quasi-monochromatic measurements of homogeneous arc plasmas.

The refined diagnostic information obtainable by high-order spectrometry is illustrated by the results of quantitative measurements of a few rotational lines of OH in the ultraviolet spectrum of water-vapor plasmas generated in a wall-stabilized arc. Because of the high spectral and spatial resolution achieved in end-on measurements, the emission and also the absorption coefficients pertaining to homogeneous arc regions were obtained directly from measured line spectra - although the absorption was not measured explicitly - leading to the occupation of the upper and the lower state for the transition. The gas temperature was determined from the halfwidth of the Doppler-broadened rotational lines. The measured resolving power of the spectrometer was of the order of 400,000 in these measurements.

Klein, L.↗

Zonal gravity harmonics from long satellite arcs by a seminumeric method.

A zonal geopotential is presented to degree 21 from evaluation of mean elements for 21 satellites, including two of low (less than 20 deg) inclination. Each satellite is represented by an arc of at least one apsidal rotation. The lengths range from 50 to 660 days. Differential correction of the initial elements in all of the arcs, together with radiation pressure and atmospheric drag coefficients, is accomplished simultaneously with the correction for the zonal harmonics. The satellite orbits and their variations are generated by numerical integration of the Lagrange equations for mean elements. Disturbances due to precession and nutation, atmospheric drag, radiation pressure, and lunisolar gravity are added at 1- to 8-day intervals in the integrated orbits.

Wagner, C. A.↗

Long and short arc altitude determination for GEOS-C

The accuracy with which the GEOS-C altitude may be estimated over long (7 day) and short (40 minute) orbital arcs is investigated. Over the long are excellent agreement was attained between a simulation of the orbit determination process and a covariance analysis. Both approaches yielded RMS altitude errors of about 1.5 meters over the Caribbean calibration area and approximately 7.5 meters overall. The geopotential was identified as the largest error source. For the short arc, the covariance analysis revealed that the propagated altitude error is linearly dependent upon station survey component errors which are also the largest source of altitude errors. An Appendix contains the mathematics of covariance analysis as applied to orbit determination.

Koch, D.↗

Submerged arc welding of heavy plate

The submerged arc process is particularly suitable for heavy plate welding because of its ability to combine very high deposit rates along with excellent quality. It does these things without the smoke and spatter often accompanying other processes. It is available today in several forms that are pointed to the fabricators of heavy sections with long, short or round about welds. Tandem arc full automatic equipment is particularly suitable for those long heavy welds where speed and deposit rate are of the first order. An attachment called long stick-out which makes use of the IR drop on long electrode extensions can be included on this equipment to increase deposition rates 50% or more.

Wilson, R. A.↗

Long term spectral irradiance measurements of a 1000-watt xenon arc lamp

Spectral irradiance measurements over the range of 200 to 1060 nm were made on a 1000-watt xenon arc lamp over a period of 1500 hours. Four sets of measurements were made after periods of 70, 525, 1000, and 1500 hours of operation. The lamp (Hanovia Compact Xenon Arc Lamp) was mounted in the NASA Solar Irradiation System. When used in the System, the lamp is used as the radiating source for six test stations. Measurements were made of both the longterm stability (or variation of spectral irradiance as a function of time) and the actual spectral irradiance incident on the test specimen.

Schneider, W. E.↗

Anode power deposition in quasi-steady MPD arcs

The power deposited in the anode of a quasi-steady MPD accelerator has been measured directly by thermocouples attached to the inside surface of a shell anode which provide a local measurement of anode heat flux. The results over a range of arc currents from 5.5 to 44 kiloamperes and argon mass flows from 1 g/sec to 48 g/sec show that the fraction of the total input power deposited in the anode decreases drastically from 50% at an arc power of 200 kW to 10% at 20 MW, and that anode power is not uniformly deposited in the anode. A theoretical model of the anode heat transfer, including effects of anode work function, electron thermal energy, and anode sheath, can be brought into reasonable agreement with the measurements, provided the effective range of the conduction electrons from within the discharge plasma to the anode surface is properly acknowledged.

Saber, A. J.↗

Nonequilibrium flow calculations for the hydrogen constricted arc

A nonequilibrium flow model has been formulated and solved numerically for conditions in an atomic hydrogen cascade arc. Solutions show that although thermal nonequilibrium effects are minor, the departure from chemical equilibrium is significant. Comparisons with results obtained from an equilibrium flow model reveal the deficiencies associated with such a model and parametric calculations reveal the effect of current, pressure, and radius on arc behavior.

Scott, R. K.↗

Arc melting and homogenization of ZrC and ZrC + B alloys

A description is given of the methods used to arc-melt and to homogenize near-stoichiometric ZrC and ZrC-boron alloys, giving attention to the oxygen contamination problem. The starting material for the carbide preparation was ZrC powder with an average particle size of 4.6 micron. Pellets weighing approximately 3 g each were prepared at room temperature from the powder by the use of an isostatic press operated at 50,000 psi. These pellets were individually melted in an arc furnace containing a static atmosphere of purified argon. A graphite resistance furnace was used for the homogenization process.

Darolia, R.↗