At least 577 records · Page 32

Enabling adoption of 2D-NMR for the higher order structure assessment of monoclonal antibody therapeutics

The increased interest in using monoclonal antibodies (mAbs) as a platform for biopharmaceuticals has led to the need for new analytical techniques that can precisely assess physicochemical properties of these large and very complex drugs for the purpose of correctly identifying quality attributes (QA). One QA, higher order structure (HOS), is unique to biopharmaceuticals and essential for establishing consistency in biopharmaceutical manufacturing, detecting process-related variations from manufacturing changes and establishing comparability between biologic products. To address this measurement challenge, two-dimensional nuclear magnetic resonance spectroscopy (2D-NMR) methods were introduced that allow for the precise atomic-level comparison of the HOS between two proteins, including mAbs. Here, an inter-laboratory comparison involving 26 industrial, government and academic laboratories worldwide was performed as a benchmark using the NISTmAb, from the National Institute of Standards and Technology (NIST), to facilitate the translation of the 2D-NMR method into routine use for biopharmaceutical product development. Two-dimensional 1H,15N and 1H,13C NMR spectra were acquired with harmonized experimental protocols on the unlabeled Fab domain and a uniformly enriched-15N, 20%-13C-enriched system suitability sample derived from the NISTmAb. Chemometric analyses from over 400 spectral maps acquired on 39 different NMR spectrometers ranging from 500 MHz to 900 MHz demonstrate spectral fingerprints that are fit-for-purpose for the assessment of HOS. The 2D-NMR method is shown to provide the measurement reliability needed to move the technique from an emerging technology to a harmonized, routine measurement that can be generally applied with great confidence to high precision assessments of the HOS of mAb-based biotherapeutics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of 2D Te and ne measurements made with Helium imaging spectroscopy in the volume of the TCV divertor

Abstract Multi-spectral imaging of helium atomic emission (HeMSI) has been used to create 2D poloidal maps of T e and n e in TCV’s divertor. To achieve these measurements, TCV’s MANTIS multispectral cameras (Perek et al 2019 Rev. Sci. Instrum. 90 123514) simultaneously imaged four He I lines (two singlet and two triplet) and a He II line (468 nm) from passively present He and He + . The images, which were absolutely calibrated and covered the whole divertor region, were inverted through the assumption of toroidal symmetry to create emissivity profiles and, consequently, line-ratio profiles. A collisional-radiative model (CRM) was applied to the line-ratio profiles to produce 2D poloidal maps of T e and n e . The collisional-radiative modeling was accomplished with the Goto helium CRM code (Zholobenko et al 2018 Nucl. Fusion 58 126006, Zholobenko et al 2018 Technical Report , Goto 2003 J. Quant. Spectrosc. Radiat. Transfer 76 331–44) which accounts for electron-impact excitation (EIE) and deexcitation, and electron–ion recombination (EIR) with He + . The HeMSI T e and n e measurements were compared with co-local Thomson scattering measurements. The two sets of measurements exhibited good agreement for ionizing plasmas: ( 5 eV ⩽ T e ⩽ 60 eV , and 2 × 10 18 m − 3 ⩽ n e ⩽ 3 × 10 19 m − 3 ) in the case of majority helium plasmas, and ( 10 eV ⩽ T e ⩽ 40 eV , 2 × 10 18 m − 3 ⩽ n e ⩽ 3 × 10 19 m − 3 ) in the case of majority deuterium plasmas. However, there were instances where HeMSI measurements diverged from Thomson scattering. When T e ⩽ 10 eV in majority deuterium plasmas, HeMSI deduced inaccurately high values of T e . This disagreement cannot be rectified within the CRM’s EIE and EIR framework. Second, on sporadic occasions within the private flux region, HeMSI produced erroneously high measurements of n e . Multi-spectral imaging of Helium emission has been demonstrated to produce accurate 2D poloidal maps of T e and n e within the divertor of a tokamak for plasma conditions relevant to contemporary divertor studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic-Field-Induced 1{sup st} order Transition to FFLO State at Paramagnetic Limit in 2D Superconductors.

We have recently reported the first direct calorimetric observation of a magnetic-field-induced first-order phase transition into a high-field FFLO superconducting state at the Clogston-Chandrasekar 'Pauli' paramagnetic limitH(p) in a 2D superconductor kappa - (BEDT-TTF)(2)Cu(NCS)(2). The high-field state is both higher entropy and strongly paramagnetic, as thermodynamically required for the FFLO state. Here we compare our results with theoretical predictions for the field dependence of the high-field FFLO state in the 2D limit, revealing tentative evidence for transitions between FFLO states of differing order parameter. We also present calorimetric evidence for a 1st order phase transition into the FFLO state for a second 2D organic superconductor: beta '' - (BEDT-TTF)(2)SF5(CH)(2)(CF)(2)(SO)(3).

Fortune, N. A.↗

Designing strong and tunable magnetoelectric coupling in 2D trilayer heterostructures

Abstract The quest for electric-field control of nanoscale magnetic states such as skyrmions, which would impact the field of spintronics, has led to a challenging search for multiferroic materials or structures with strong magnetoelectric coupling and efficient electric-field control. Here we report a theoretical prediction that such phenomena can be realized in two-dimensional (2D) bilayer FE/PMM and trilayer FE/PMM/FE heterostructures (two-terminal and three-terminal devices), where FE is a 2D ferroelectric and PMM is a polar magnetic metal with strong spin–orbit coupling. Such a PMM has strong Dzyaloshinskii-Moriya interactions (DMI) that can generate skyrmions, while the FE can generate strong magnetoelectric coupling through polarization-polarization interactions. In trilayer heterostructures, contact to the metallic PMM layer enables multiple polarization configurations for electric-field control of skyrmions. We report density-functional-theory calculations for particular material choices that demonstrate the effectiveness of these arrangements, with the key driver being the polarization-polarization interactions between the PMM and FE layers. The present findings provide a method to achieve strong magnetoelectric coupling in the 2D limit and a new perspective for the design of related spintronics.

Materials Science↗

Federated learning for 2D synchrotron x-ray diffractometry: a cross-institutional approach for phase quantification of Ti–6Al–4V alloy

High-energy Two dimensional (2D) synchrotron x-ray diffractometry provides important insights into the atomistic structure and phase evolution of materials, yet traditional analysis methods remain complex, knowledge-intensive, and computationally demanding. Deep-learning models offer a powerful alternative for automating their analysis. Institutions that hold these datasets may be unwilling to share their data due to privacy and security policies, as well as the challenges associated with large-scale data transfer. As a result, models trained on local datasets often perform well only on their own data but exhibit bias and poor generalization across different instruments or facilities. To overcome these limitations, we explore federated learning (FL) for 2D synchrotron diffractograms, enabling collaborative model training without exchanging raw data. In this study, 2D synchrotron diffractograms of Ti–6Al–4V alloy collected from two independent facilities are used to train convolutional neural networks for predicting the β-phase volume fraction. Experimental results show that federated global models significantly outperform locally trained models in terms of generalization and achieve accuracy comparable to centralized trained models. These findings demonstrate the potential of FL to enable secure, cross-institutional collaboration and enhance the scalability of deep-learning-based materials characterization.

36 MATERIALS SCIENCE↗

Switching charge states in quasi-2D molecular conductors

Abstract 2D molecular entities build next-generation electronic devices, where abundant elements of organic molecules are attractive due to the modern synthetic and stimuli control through chemical, conformational, and electronic modifications in electronics. Despite its promising potential, the insufficient control over charge states and electronic stabilities must be overcome in molecular electronic devices. Here, we show the reversible switching of modulated charge states in an exfoliatable 2D-layered molecular conductor based on bis(ethylenedithio)tetrathiafulvalene molecular dimers. The multiple stimuli application of cooling rate, current, voltage, and laser irradiation in a concurrent manner facilitates the controllable manipulation of charge crystal, glass, liquid, and metal phases. The four orders of magnitude switching of electric resistance are triggered by stimuli-responsive charge distribution among molecular dimers. The tunable charge transport in 2D molecular conductors reveals the kinetic process of charge configurations under stimuli, promising to add electric functions in molecular circuitry.

Huang, Yulong (ORCID:0000000296160134)↗

Cross-correlating 2D and 3D galaxy surveys

Galaxy surveys probe both structure formation and the expansion rate, making them promising avenues for understanding the dark universe. Photometric surveys accurately map the 2D distribution of galaxy positions and shapes in a given redshift range, while spectroscopic surveys provide sparser 3D maps of the galaxy distribution. We present a way to analyse overlapping 2D and 3D maps jointly and without loss of information. We represent 3D maps using spherical Fourier-Bessel (sFB) modes, which preserve radial coverage while accounting for the spherical sky geometry, and we decompose 2D maps in a spherical harmonic basis. In these bases, a simple expression exists for the cross-correlation of the two fields. One very powerful application is the ability to simultaneously constrain the redshift distribution of the photometric sample, the sample biases, and cosmological parameters. We use our framework to show that combined analysis of DESI and LSST can improve cosmological constraints by factors of ${\sim}1.2$ to ${\sim}1.8$ on the region where they overlap relative to identically sized disjoint regions. We also show that in the overlap of DES and SDSS-III in Stripe 82, cross-correlating improves photo-$z$ parameter constraints by factors of ${\sim}2$ to ${\sim}12$ over internal photo-$z$ reconstructions.

79 ASTRONOMY AND ASTROPHYSICS↗

Crossover from 2D to 3D in a Weakly Interacting Fermi Gas

We have studied the transition from two to three dimensions in a low temperature weakly interacting {sup 6}Li Fermi gas. Below a critical atom number N{sub 2D} only the lowest transverse vibrational state of a highly anisotropic oblate trapping potential is occupied and the gas is two dimensional. Above N{sub 2D} the Fermi gas enters the quasi-2D regime where shell structure associated with the filling of individual transverse oscillator states is apparent. This dimensional crossover is demonstrated through measurements of the cloud size and aspect ratio versus atom number.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mapping Thermal Expansion Coefficients in Freestanding 2D Materials at the Nanometer Scale

Two-dimensional materials, including graphene, transition metal dichalcogenides and their heterostructures, exhibit great potential for a variety of applications, such as transistors, spintronics, and photovoltaics. While the miniaturization offers remarkable improvements in electrical performance, heat dissipation and thermal mismatch can be a problem in designing electronic devices based on two-dimensional materials. Quantifying the thermal expansion coefficient of 2D materials requires temperature measurements at nanometer scale. Here, we introduce a novel nanometer-scale thermometry approach to measure temperature and quantify the thermal expansion coefficients in 2D materials based on scanning transmission electron microscopy combined with electron energy-loss spectroscopy to determine the energy shift of the plasmon resonance peak of 2D materials as a function of sample temperature. Iin this work, by combining these measurements with first-principles modeling, the thermal expansion coefficients (TECs) of single-layer and freestanding graphene and bulk, as well as monolayer MoS 2 , MoSe 2 , WS 2 , orWSe 2 , are directly determined and mapped.

36 MATERIALS SCIENCE↗

Resolving Continua of Fractional Excitations by Spinon Echo in THz 2D Coherent Spectroscopy

We show that the new technique of terahertz 2D coherent spectroscopy is capable of giving qualitatively new information about fractionalized spin systems. For the prototypical example of the transverse field Ising chain, we demonstrate theoretically that, despite the broad continuum of excitations in linear response, the 2D spectrum contains sharp features that are a coherent signature of a “spinon echo,” which gives previously inaccessible information such as the lifetime of the two-spinon excited state. Here, the effects of disorder and finite lifetime, which are practically indistinguishable in the linear optical or neutron response, manifest in dramatically different fashion in the 2D spectra. Our results may be directly applicable to model quasi-1D transverse field Ising chain systems such as CoNb 2 O 6 , but the concept can be applied to fractionalized spin systems in general.

1-dimensional spin chains↗

Monolayer CrCl 3 as an Ideal Test Bed for the Universality Classes of 2D Magnetism

The monolayer halides CrX 3 (X=Cl, Br, I) attract significant attention for realizing 2D magnets with genuine long-range order (LRO), challenging the Mermin-Wagner theorem. In this work, we show that monolayer CrCl 3 has the unique benefit of exhibiting tunable magnetic anisotropy upon applying a compressive strain. This opens the possibility to use CrCl 3 for producing and studying both ferromagnetic and antiferromagnetic 2D Ising-type LRO as well as the Berezinskii-Kosterlitz-Thouless (BKT) regime of 2D magnetism with quasi-LRO. Using state-of-the-art density functional theory, we explain how realistic compressive strain could be used to tune the monolayer's magnetic properties so that it could exhibit any of these phases. Building on large-scale quantum Monte Carlo simulations, we compute the phase diagram of strained CrCl 3 , as well as the magnon spectrum with spin-wave theory. Our results highlight the eminent suitability of monolayer CrCl 3 to achieve very high BKT transition temperatures, around 50 K, due to their singular dependence on the weak easy-plane anisotropy of the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monolayer 2D semiconducting tellurides for high-mobility electronics

Discovery and design of two-dimensional (2D) materials with suitable band gaps and high carrier mobility are of vital importance for the photonics, optoelectronics, and high-speed electronics. In this work, based on first principles calculations using density functional theory with Perdew-Burke-Ernzerhof and Heyd-Scuseria-Ernzerhoffunctionals, we introduce a family of monolayer isostructural semiconducting tellurides MNTe 4 , with M={Ti,Zr,Hf} and N={Si,Ge}. We find that these compounds have been identified to possess direct band gaps from 1.0 to 1.31 eV, which are well suited for photonics and optoelectronics applications. Additionally, anisotropic in-plane transport behavior is observed, and small electron and hole (0.11–0.15m e ) effective masses are identified along the dominant transport direction. Ultrahigh carrier mobility is predicted for this family of 2D compounds, which host great promise for potential applications in high-speed electronic devices. Furthermore, detailed analysis of electronic structures reveals the origins of the promising properties of this unique class of 2D telluride materials.

2-dimensional systems↗

Colloquium : Sliding and pinning in structurally lubric 2D material interfaces

A plethora of two-dimensional (2D) materials have been introduced in physics and engineering in the past two decades. Their robust, membranelike sheets permit (mostly require) deposition, giving rise to solid-solid dry interfaces whose mobility, pinning, and general tribological properties under shear stress are currently being understood and controlled, both experimentally and theoretically. Here, in this Colloquium simulated case studies of twisted graphene systems are used as a prototype workhorse tool to demonstrate and discuss the general picture of 2D material interface sliding. First highlighted is the crucial mechanical difference, often overlooked, between small and large incommensurabilities, which corresponds to, for example, small and large twist angles in graphene interfaces. In both cases, focusing on flat, structurally lubric or “superlubric” geometries, the generally separate scalings with the area of static friction in pinned states and of kinetic friction during sliding are elucidated and reviewed, tangled as they are with the effects of velocity, temperature, load, and defects. The roles of island boundaries and elasticity are also discussed, and compared when possible to results in the literature for systems other than graphene. It is proposed that the resulting picture of pinning and sliding should be applicable to interfaces in generic 2D materials that are of importance for the physics and technology of existing and future bilayer and multilayer systems.

2-dimensional systems↗

Engineering 2D Square Lattice Hubbard Models in 90° Twisted GeX/SnX (X =S, Se) Moiré Superlattices

Because of the large-period superlattices emerging in moiré two-dimensional (2D) materials, electronic states in such systems exhibit low energy flat bands that can be used to simulate strongly correlated physics in a highly tunable setup. While many investigations have thus far focused on moiré flat bands and emergent correlated electron physics in triangular, honeycomb, and quasi-one-dimensional lattices, tunable moiré realizations of square lattices subject to strong correlations remain elusive. Here, in this work, we propose a feasible scheme to construct moiré square lattice systems by twisting two or more layers of 2D materials in a rectangular lattice by 90°. We demonstrate the concept with twisted GeX/SnX (X =S, Se) moiré superlattices and calculate their electronic structures from first principles. We show that the lowest conduction flat band in these systems can be described by a square lattice Hubbard model with parameters which can be controlled by varying the choice of host materials, number of layers, and external electric fields. In particular, twisted double bilayer GeSe realizes a square lattice Hubbard model with strong frustration due to the next-nearest-neighbor hopping that could host unconventional superconductivity, in close analogy to the Hubbard model for copper-oxygen planes of cuprate high-temperature superconductors. The presented scheme uses 90° twisted 2D materials with rectangular unit cells as a promising platform for realizing the physical phenomena of square lattice Hubbard models, establishing a new route for studying its rich phase diagram of magnetism, charge order, and unconventional superconductivity in a highly tunable setting.

2-dimensional systems↗

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2D-3D registration for prostate radiation therapy based on a statistical model of transmission images

Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D-3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model-based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of 3 mm for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone-beam CT (CBCT) and kV projection radiographs of the phantom in the anterior-posterior (AP) view, registration accuracies were 0.42 mm (MLP), 0.29 mm (MLG), and 0.29 mm (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were 1.15 mm (MLP), 0.90 mm (MLG), and 0.69 mm (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗