Automated inspection of wire-frame assemblies

System improves accuracy of measurement between spaces of wire mesh and other wire frame assemblies while significantly reducing inspection time. Device operates automatically producing printout of measured spacings through use of optical scanner.

Etzel, J. G.↗

Voltages and currents induced on wiring

Aircraft lightning strikes were investigated in regard to their effects on voltages and currents in aircraft wiring. An electrical conductor's response to magnetic fields and electric fields was examined as part of the voltage and current calculations. The wiring system of the space shuttle was briefly considered as an example.

Franklin A Fisher↗

Buried wire gage for wall shear stress measurements

A buried wire gage for measuring wall shear stress in fluid flow was studied and further developed. Several methods of making this relatively new type of gage were examined to arrive at a successful technique that is well-suited for wind-tunnel testing. A series of measurements was made to demonstrate the adequacy of a two-point calibration procedure for these gages. The buried wire gage is also demonstrated to be ideally suited for quantitative measurement of wall shear stress in wind-tunnel testing.

Murthy, V. S.↗

A hybrid technique for wire antennas in a cavity

An evaluation is conducted of two numerical techniques developed by Richmond (1961, 1966) for wire antennas and scattering bodies. It is concluded that a more efficient and accurate scheme can be devised by suitably combining the two techniques. This scheme, which is called the 'hybrid method', is well suited for a wire antenna mounted in a cavity. Reaction matching is employed in the case of the antenna, while point matching is used for the support structure. The described approach makes it possible to consider voltage generators without the use of any equivalent magnetic frill current sources. The number of unknown currents to be determined is essentially optimized by this combination of reaction matching and point matching. The resulting current distribution is a quantized distribution on the support structure and is continuous on the main radiator.

Agrawal, P. K.↗

Hot-wire, laser anemometer and force balance measurements of cross-sectional planes of single and interacting trailing vortices

Single and multiple trailing vortices shed from semi-span wings and a transport model in a wind tunnel were studied by means of a laser-velocimeter, hot-wire anemometer, and a trailing model incorporating a 6-component force balance. Velocity profile and turbulence data from the laser-velocimeter and hot-wire anemometer are presented and shown to compare well with the Betz inviscid circulation model. Lift and rolling moment measurements on the following model are compared with those predicted from the flow field measurements.

Iversen, J. D.↗

On the measurement of turbulent fluctuations in high-speed flows using hot wires and hot films

A hot wire has a limited life in high speed wind-tunnel flows because it is typically subjected to large dynamic loads. As a consequence hot films and modified hot wires are frequently used for turbulence measurements in such flows. However, the fluctuation sensitivities of such probes are reduced because of various factors, leading to erroneous results. This paper describes the results of tests on some sensors in both subsonic and supersonic boundary-layer flows. A simple technique to determine dynamic calibration correction factors for the sensitivities is also presented.

Acharya, M.↗

Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

Wood, M. E.↗

Wall proximity corrections for hot-wire readings in turbulent flows

This note describes some details of recent (successful) attempts of wall proximity corrections for hot-wire measurements performed in a three-dimensional incompressible turbulent boundary layer. A simple and quite satisfactory method of estimating wall proximity effects on hot-wire readings is suggested.

Hebbar, K. S.↗

Add-On Shielding for Unshielded Wire

Fabrication sequence used to produce compact shields slipped into place from free ends of wires already soldered into connectors at other ends. Single shields are formed into harnesses by connecting grounding jumpers. Technique is especially useful for small diameter wire attached to microminiature connectors.

Koenig, J. C.↗

Wire Electrical-Discharge Machining Aid

Rerouting cutting wire by adding idler rollers allows standard wire electrical-discharge machine (WEDM) temporarily modified to permit some types of cuts otherwise blocked.

Gollihugh, T.↗

Wire electric-discharge machining and other fabrication techniques

Wire electric discharge machining and extrude honing were used to fabricate a two dimensional wing for cryogenic wind tunnel testing. Electric-discharge cutting is done with a moving wire electrode. The cut track is controlled by means of a punched-tape program and the cutting feed is regulated according to the progress of the work. Electric-discharge machining involves no contact with the work piece, and no mechanical force is exerted. Extrude hone is a process for honing finish-machined surfaces by the extrusion of an abrasive material (silly putty), which is forced through a restrictive fixture. The fabrication steps are described and production times are given.

Morgan, W. H.↗

Turbulence measurements in a complex plowfield using a crossed hot-wire

Turbulence was quantified in complex axisymmetric, nonreacting, nonswirling flowfields using a crossed hot-wire anemometer. Mean velocity, turbulence intensities, turbulent viscosity, and Reynolds tree were measured in round free jet and confined jet flowfields. The confined jet, a model of an axisymmetric can combustor, had an expansion ratio D/d=2, an expansion angle of 90 deg, and an axial location increments of 0.5 diameters. The confined jet was studied with and without a contraction nozzle. Free jet measurements validated the experimental technique and data reduction. Results show good agreement with those of previous research. Measurements in the confined jet indicate that the cross hot-wire used cannot handle axial flow reversal and the experimental technique is inadequate for measuring time-mean radial velocity. Other quantities show a high level of comparability.

Mckillop, B. E.↗

Joining lead wires to thin platinum alloy films

A two step process of joining a lead wire to .000002 m thick platinum alloy film which rests upon an equally thin alumina insulating layer which is adhered to a metal substrate is described. Typically the platinum alloy film forms part of a thermocouple for measuring the surface temperature of a gas turbine airfoil. In the first step the lead wire is deformed 30 to 60% at room temperature while the characteristic one million ohm resistance of the alumina insulating layer is monitored for degradation. In the second step the cold pressed assembly is heated at 865 to 1025 C for 4 to 75 hr in air. During the heating step any degradation of insulating layer resistance may be reversed, provided the resistance was not decreased below 100 ohm in the cold pressing.

Przybyszewski, J. S.↗

Recent developments in multi-wire fixed abrasive slicing technique (FAST)

Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

Schmid, F.↗

Single-wire swirl flow turbulence measurements

A six-orientation, single wire hot wire technique is used to investigate nonswirling and swirling nonreacting flow in an axisymmetric test section with expansion ratio (test section/inlet nozzle diameter) = 2, which may be equipped with a strong contraction nozzle of area ratio 4 at a contraction nozzle downstream distance/test section diameter value = 2. The flowfield contains corner and central recirculation zones typical of gas turbine and ramjet combustion chambers. Swirl may be imparted to the incoming flow by means of a variable angle vane swirler. The effect of swirl on time mean velocities and complete Reynolds stress tensor is investigated, and extensive results are given for swirl vane angles of zero (swirler removed), 38, 45, 60 and 70 deg. The data are being used to aid in the evolution of turbulence models for these complex flow situations. A directional sensitivity analysis is included, which determines the relative accuracy of the measurement technique to approach velocity orientation.

Lilley, D. G.↗

Constant-Operating-Resistance Hot-Wire Probe

Effects of lead-wire-resistance changes with temperature nullified. Constant-operating-resistance hot-wire probe uses two sets of leads. Exposed to identical conditions, comparison of resistance gives change in sensing element itself. Data taken in more convenient manner, with advantage of not having to constantly check for possible changes in lead resistance and consequently readjust potentiometer.

Stainback, P. C.↗

Hot wire in low Reynolds number flow

Progress reports were issued on the following experiments: (1) low Reynolds number flow phenomenon of periodic vortex shedding in the wake behind a cylinder as studied by applying the hot wire anemometer technique of flow measurement. The downstream diffusion of these shed vortices was of prime concern. An evaluation of the performance of the hot wire at low Reynolds number is also considered. (2) A brief examination of the back sections of the Wright Brothers wind tunnel circuits were conducted to establish whether or not gross flow deviations were present at corners, or turning vane regions. A calibration of the test sections was done. (3) The attractiveness of using rembedded grids for airfoil calculations modeled by the Euler equations was explored. These calculations were extended to C-type grids and then to Navier-Stokes calculations,

Kolb, M. A.↗