Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

WaterTAP 0.5 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.6 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.7 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.8 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.10 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.11 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 0.12 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

IDAES↗

WaterTAP 1.0 Release

The Water treatment Technoeconomic Assessment Platform (WaterTAP) is an open-source Python-based software package that supports the simulation and optimization of process-scale water treatment trains. WaterTAP seeks to provide the broader water research community with an integrated modeling capability to evaluate cost, energy, and environmental tradeoffs across water treatment options and identify high impact opportunities for innovation including novel materials, processes, and systems. An updated version of WaterTAP is released quarterly and each includes documentation and release notes.

AS↗

SEASAT economic assessment. Volume 4: Ocean mining case study and generalization

The results of a study of the weather sensitive features of near shore and deep water ocean mining industries are described. Problems with the evaluation of economic benefits for the deep water ocean mining industry are attributed to the relative immaturity and highly proprietary nature of the industry. Case studies on the gold industry, diamond industry, tin industry and sand and gravel industry are cited.

Source record↗

Diel mercury concentration variations in a mercury-impacted stream

Here, filtered and particulate mercury (Hg) and methylmercury (MMHg), and associated water chemistry parameters, were evaluated bi-hourly for several 30 h periods during the summer and winter seasons at several distinct locations (downstream forested, midstream urban/suburban, upstream industrial) along a creek contaminated with high levels of inorganic Hg to determine if biogeochemical Hg and MMHg cycles respond to the daily photocycle. In summer particulate Hg and MMHg concentrations doubled overnight (excluding the upstream industrial site) concurrent with increases in turbidity and total suspended sediment; no such pattern was evident in winter. Seasonal and diel changes in the activity of macrobiota affecting the suspension of contaminated sediments are likely responsible for these patterns as other potential explanatory variables (e.g., instrument drift, pH, discharge) could not account for the range and timing of our observations. Diel patterns in filtered Hg (Hg D ) were significant only at locations and times of the year when channel shading was not present and daytime concentrations increased 22–89% above nighttime minima likely caused by direct and indirect photochemical reactions. Relationships between Hg D and dissolved organic carbon (DOC) concentration or character were inconsistent between sites. Unlike Hg D , there were significant diel patterns in filtered MMHg (MMHg D ) at all sites and times of year, with summer concentrations peaking in mid to late afternoon while the timing differed in winter, with concentrations peaking after sunset. Daily variability in MMHg D concentration ranged between 25 and 75%. The results imply key controls on net methylation occur within the stream or on the stream bed and include factors such as small-scale temperature changes in the water column and photosynthetic activity of stream biofilm. With respect to stream monitoring, results from this study indicate (1) consistent timing in stream Hg and MMHg sampling is required for accurate assessment of long-term trends, (2) in situ measurements of turbidity can be used to quantify diel dynamics of both particulate Hg and MMHg concentrations, and (3) in situ fluorescing dissolved organic matter (FDOM), a potential proxy for DOC, was not capable of resolving diel dynamics of filtered Hg or MMHg.

54 ENVIRONMENTAL SCIENCES↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

Quantifying the effects of urbanization on floods in a changing environment to promote water security — A case study of two adjacent basins in Texas

The increased occurrence of flood events resulting from urbanization and global climate change is a great threat to water security. To systematically evaluate the impacts of urbanization on floods, here we applied a paired catchments approach to two adjacent river basins in south-central Texas — the San Antonio River Basin (SARB), with fast urbanization; and the Guadalupe River Basin (GRB), with little land cover change. A physics-based distributed hydrological model — the Distributed Hydrology Soil Vegetation Model, embedded with a multi-purpose reservoir module (DHSVM-Res) — was used to simulate streamflow and reservoir storage. The simulations were conducted under different land cover scenarios, including a newly developed continuous land cover series (CLCS). Holistic analyses were then conducted for the paired basins using three methods: analyzing the selected flood events, detecting change points (CP) of monthly floods, and testing the elasticity of long-term flood regimes. The results suggest that: (1) urbanization may reduce lag time and elevate flood peaks significantly by 3–30% in our study area; (2) when there is little land cover change, changing climate is the major driver of variations in the monthly maximum streamflow (MMS); (3) fast urbanization can amplify streamflow variability, increase MMS significantly, and thus alter the timing of CP; and (4) the mean MMS of observed streamflow in the SARB has increased by as much as 75.7% from the pre-CP to post-CP periods. This comprehensive study fills in a gap in our current understanding of the isolated impacts of urbanization on flooding and is expected to support future explorations of anthropogenic influences on floods.

54 ENVIRONMENTAL SCIENCES↗

Near-Global Variability of Stratospheric Water Vapor Observed by SAGE III/ISS

The Stratospheric Aerosol and Gas Experiment III instrument on the International Space Station (SAGE III/ISS) has been making high quality solar occultation measurements of stratospheric water vapor since June 2017. Here we evaluate the large-scale geophysical variability of the SAGE III/ISS water vapor measurements for the first 3 years of observations (2017–2020) as part of data validation for retrieval version 5.1 (v5.1). Detailed comparisons of SAGE III/ISS v5.1 with the Aura Microwave Limb Sounder (MLS) version 5 retrievals show overall excellent agreement in terms of seasonal mean structure and large-scale variability. SAGE III/ISS data capture the well-known seasonal variations in water vapor including the vertically propagating “tape recorder” in the tropics and lower stratospheric maxima linked to the NH summer monsoons. The high vertical resolution (∼2 km) measurements from SAGE III/ISS demonstrate contributions of the monsoons to the wet phase of “tape recorder” during the Northern Hemisphere (NH) summer. Interannual variations over the short data record are also consistent between SAGE III/ISS and MLS in the stratosphere between 16 and 30 km. We furthermore evaluate large-scale variations in relative humidity (RH) derived from the high vertical resolution SAGE III/ISS water vapor measurements, highlighting the detailed seasonal behavior and links to thermal structure near the tropical tropopause. Spatial distributions of RH at the cold point tropopause (CPT) show a close link between high RH and the minimum CPT temperature in both the NH winter and summer, consistent with temperature control of water vapor near the tropopause.

water vapor↗

Advanced Space Suit PLSS 2.0 Cooling Loop Evaluation and PLSS 2.5 Recommendations

From 2012 to 2015 The NASA/JSC AdvSS (Advanced Space Suit) PLSS (Primary Life Support Subsystem) team, with support from UTC Aerospace Systems, performed the build-up, packaging and testing of PLSS 2.0. A key aspect of that testing was the evaluation of the long-term health of the water cooling circuit and the interfacing components. Intermittent and end-of-test water, residue and hardware analyses provided valuable information on the status of the water cooling circuit, and the approaches that would be necessary to enhance water cooling circuit health in the future. The evaluated data has been consolidated, interpreted and woven into an action plan for the maintenance of water cooling circuit health for the planned FY (fiscal year) 2016 through FY 2018 PLSS 2.5 testing. This paper provides an overview of the PLSS 2.0 water cooling circuit findings and the associated steps to be taken in that regard for the PLSS 2.5 testing.

Steele, John↗

Advanced Space Suit PLSS 2.0 Cooling Loop Evaluation and PLSS 2.5 Recommendations

From 2012 to 2015 The NASA/JSC AdvSS (Advanced Space Suit) PLSS (Portable Life Support Subsystem) team, with support from UTC Aerospace Systems, performed the build-up, packaging and testing of PLSS 2.0. One aspect of that testing was the evaluation of the long-term health of the water cooling circuit and the interfacing components. Periodic and end-of-test water, residue and hardware analyses provided valuable information on the status of the water cooling circuit, and the approaches that would be necessary to enhance water cooling circuit health in the future. The evaluated data has been consolidated, interpreted and woven into an action plan for the maintenance of water cooling circuit health for the planned FY (fiscal year) 2016 through FY 2018 PLSS 2.5 testing. This paper provides an overview of the PLSS 2.0 water cooling circuit findings and the associated steps to be taken in that regard for the PLSS 2.5.

Steele, John↗

Decision-Making Framework to Evaluate Opportunities for Recovery of Rare Earth Elements and Critical Minerals in Produced Water Networks

Oil and gas development activities require a significant amount of water. Given the environmental impacts associated with high consumption and subsequent disposal of this water, there is a need for strategies to support effective reuse of, treatment of, and/or resource recovery from this produced water. These streams can contain appreciable concentrations of rare earth elements (REE) and critical minerals (CM) (e.g., Lithium), which are critical for many important applications in electronics, technology, manufacturing, energy, and medicine [1]. Along with REE/CM present in produced water, other waste streams such as fly ash from coal-fired power plants and acid mine discharge present other potential sources for recovery of REE/CM [2-4]. And with increases in demand for REE/CM, the need for recovery from wastewater streams is becoming even more important. There is a need to develop effective decision-making tools to evaluate the economic and environmental potential for REE/CM recovery from produced water networks while supporting the needs of drilling and hydraulic fracturing activities. In this work, we present our progress in developing a decision-making framework to efficiently design and operate produced water networks for REE/CM recovery. Our approach considers REE/CM recovery from produced water streams alongside other potential wastewater sources. The models consider the location and capacity of storage and decentralized treatment processes as well as the design and operation of pipeline and transportation networks to connect different sources and effectively schedule inventories, reuse, and recovery opportunities. We focus on the evaluation of opportunities for REE/CM recovery with treatment constraints on composition and flow. We demonstrate this framework with an illustrative case study that features diverse production sites, storage facilities, transportation, and treatment sites. This proposed framework will be deployed in an open-source software package that is compatible with the PARETO framework to deliver analysis and decision-making tools that allow stakeholders to quantitatively evaluate potential opportunities for REE/CM recovery in produced water networks.

Pulsipher, Joshua↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗