Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

ON IMPROVING ANALYTICAL MODELS OF COSMIC REIONIZATION FOR MATCHING NUMERICAL SIMULATION

The methods for studying the epoch of cosmic reionization vary from full radiative transfer simulations to purely analytical models. While numerical approaches are computationally expensive and are not suitable for generating many mock catalogs, analytical methods are based on assumptions and approximations. We explore the interconnection between both methods. First, we ask how the analytical framework of excursion set formalism can be used for statistical analysis of numerical simulations and visual representation of the morphology of ionization fronts. Second, we explore the methods of training the analytical model on a given numerical simulation. We present a new code which emerged from this study. Its main application is to match the analytical model with a numerical simulation. Then, it allows one to generate mock reionization catalogs with volumes exceeding the original simulation quickly and computationally inexpensively, meanwhile reproducing large-scale statistical properties. These mock catalogs are particularly useful for cosmic microwave background polarization and 21 cm experiments, where large volumes are required to simulate the observed signal.

79 ASTRONOMY AND ASTROPHYSICS↗

A simple technique to reduce evaporation of crystallization droplets by using plate lids with apertures for adding liquids

This article describes the use of evaporation control lids that are fitted to crystallization plates to improve the reproducibility of trials using as little as 5 nl. The plate lids contain apertures which are large enough for the transfer of protein containing droplets, but small enough to greatly reduce the rate of evaporation during the time needed to prepare the plate. A method is described for using plate lids to reduce evaporation in low-volume vapor-diffusion crystallization experiments. The plate lids contain apertures through which the protein and precipitants were added to different crystallization microplates (the reservoir was filled before fitting the lids). Plate lids were designed for each of these commonly used crystallization microplates. This system minimizes the dehydration of crystallization droplets containing just a few nanolitres of protein and precipitant, and results in more reproducible diffraction from the crystals. For each lid design, changes in the weight of the plates were used to deduce the rate of evaporation under different conditions of temperature, air movement, droplet size and precipitant. For comparison, the state of dehydration was also visually assessed throughout the experiment. Finally, X-ray diffraction methods were used to compare the diffraction of protein crystals that were conventionally prepared against those that were prepared on plates with plate lids. The measurements revealed that the plate lids reduced the rate of evaporation by 63–82%. Crystals grown in 5 nl drops that were set up with plate lids diffracted to higher resolution than similar crystals from drops that were set up without plate lids. The results demonstrate that plate lids can be instrumental for improving few-nanolitre crystallizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

{sup 18}F-sodium fluoride positron emission tomography assessed microcalcifications in culprit and non-culprit human carotid plaques

Background: {sup 18}F-NaF positron emission tomography (PET) targets microcalcifications. We compared in vitro microPET assessed {sup 18}F-NaF uptake between culprit and non-culprit human carotid plaques. Furthermore, we compared {sup 18}F-NaF uptake with calcification visualized on microcomputed tomography (microCT). Methods: Carotid plaques from stroke patients undergoing surgery were incubated in {sup 18}F-NaF and scanned using a microPET and a microCT scan. The average PET assessed {sup 18}F-NaF uptake was expressed as percentage of the incubation dose per gram (%Inc/g). {sup 18}F-NaF PET volume of interest (VOI) was compared with CT calcification VOI. Results: 23 carotid plaques (17 culprit, 6 non-culprit) were included. The average {sup 18}F-NaF uptake in culprit carotid plaques was comparable with the uptake in non-culprit carotid plaques (median 2.32 %Inc/g [IQR 1.98 to 2.81] vs. median 2.35 %Inc/g [IQR 1.77 to 3.00], P = 0.916). Only a median of 10% (IQR 4 to 25) of CT calcification VOI showed increased {sup 18}F-NaF uptake, while merely a median of 35% (IQR 6 to 42) of {sup 18}F-NaF PET VOI showed calcification on CT. Conclusions: {sup 18}F-NaF PET represents a different stage in the calcification process than CT. We observed a similar PET assessed {sup 18}F-NaF uptake and pattern in culprit and non-culprit plaques of high-risk patients, indicating that this method may be of more value in early atherosclerotic stenosis development. [French] French Abstract: Contexte: La tomographie par émission de positons (TEP) au {sup 18}F-NaF marque les micro-calcifications. Nous avons comparé in vitro les plaques carotidiennes humaines responsable d’accident vasculaire cérébrales marquées au {sup 18}F-NaF avec une microTEP et leur calcification au moyen d’un microCT Méthodes: Les plaques carotidiennes de patients victimes d’un accident vasculaire cérébral qui ont bénéficié d’ une intervention chirurgicale ont été incubées dans du {sup 18}F-NaF et imagées avec une microTEP et un microCT. Le pourcentage d’absorption moyen de {sup 18}F-NaF par gr de tissu (% Inc/g) ont été comparées au volume d’intérêt (VOI) des calcifications mesurées par CT. Résultats: 23 plaques carotidiennes (17 responsables d’un AVC et 6 non responsables) ont été incluses. Le % moyen d’absorption de {sup 18}F-NaF dans les plaques carotidiennes responsables furent comparable à l’absorption dans les plaques non responsables (2,32% Inc/g vs 2,35% Inc/g , p = 0,916). Dix pourcent seulement des calcifications visualisées par CT démontrèrent une augmentation d’absorption de {sup 18}F-NaF et 35% des plaques montrant une absorption de {sup 18}F-NaF PET VOI démontrèrent des calcifications au CT. Conclusions: L’imagerie de l’absorption de {sup 18}F-NaF par tomographie à positrons représente un processus physiopathologique différent de l’imagerie des calcifications par CT. L’absorption du {sup 18}F-NaF par les plaques responsables et non responsables d’accidents vasculaire cérébraux pourrait s’avérer utile dans le diagnostic précoce des sténoses athéromateuses. [Spanish] Spanish Abstract: Antecedentes: La tomografía por emisión de positrones (PET) con {sup 18}F-floruro de sodio ({sup 18}F-NaF) demuestra microcalcificaciones. En este estudio, comparamos la captación de {sup 18}F-NaF entre placas carotideas culpables y no culpables valorada con microPET in vitro. Además, comparamos la captación de {sup 18}F-NAF con las calcificaciones detectadas por microtomografía computada (microCT). Métodos: Placas carotídeas de pacientes postoperados que sufrieron de un evento vascular cerebral fueron incubadas en 18-NaF y escaneadas usando microPET y microCT. El promedio de la captación fue expresado como porcentaje de la dosis de incubación por gramo (%Inc/gr). El volumen de interés (VOI) del PET {sup 18}F-NaF se comparó con el VOI de calcificación por CT. Resultados: Se incluyeron 23 placas carotídeas (17 culpables y 6 no culpables). El promedio de la captación de {sup 18}F-NaF en placas carotídeas culpable fue comparable al de las placas no culpables. (mediana 2.32%Inc/gr [IQR1.98-2.81] vs. mediana 2.35%Inc/gr [IQR1.77-3], p=.916). Solo una mediana de 10% (IQR 4-25) del VOI en CT mostró un aumento en la captación de {sup 18}F-NaF, mientras una mediana de 35% (IQR 6-42) del VOI de PET {sup 18}F-NaF mostró calcificación en CT. Conclusiones: La tomografía por emisión de positrones con {sup 18}F-NaF evalúa una etapa distinta en el proceso de calcificación que la CT. El patrón de captación de {sup 18}F-NaF que observamos en este estudio fue similar entre placas culpables y no culpables de pacientes de alto riesgo, lo cual indica que este método puede ser de mayor valor en el desarrollo temprano de la estenosis ateroesclerótica. [Chinese] Chinese Abstract: 背景: F18 氟化钠正电子发射断层扫描 (PET) 可用于检测微钙化。我们使用微型 PET 来评估病人体外 F18 氟化钠在颈动脉罪犯和非罪犯斑块之间的的摄取区别。此外, 我们还将 F18 氟化钠的摄取与 microCT 扫描检测的钙化进行对比。 方法: 将接受手术的中风患者的颈动脉斑块在 F18 氟化钠中培养并用 microPE 和 microCT 进行扫描。PET 对 F18 氟化钠的平均摄取率表示为每克培养剂量的百分比。F18 氟化钠 PET 中的感兴趣区域和 CT 钙化图像中的感兴趣区域 (VOI) 进行比较。 结果: 一共有 23个颈动脉斑块, 其中 17个罪犯斑块和 6个非罪犯斑块。罪犯和非罪犯颈动脉斑块的 F18 氟化钠的平均摄取率无明显差异 (中值 2.32 % Inc/g [IQR 1.98-2.81] vs. 中值2.35 % Inc/g [IQR 1.77-3.00], p = 0.916)。仅中值为10% [IQR 4-25] 的 CT 钙化 VOI 显示有F18氟化钠的摄取增加, 中值为 35%[IQR 6-42] 的 F18 氟化钠 PET VOI 显示有CT 上的钙化。 结论: 相较于 CT, F18 氟化钠 PET 展现了钙化过程中的一个不同阶段。在高危病人中, 我们观察到罪犯和非罪犯斑块具有类似的 PET F18 氟化钠摄取和模式, 表明该方法可能在早期动脉粥样硬化狭窄发展中具有更高的价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Why wait? Let's start computing while data is still on the wire

In this era of Big Data, computing useful information from data is becoming increasingly complicated, particularly due to the ever increasing volumes of data that need to travel over the network to data centers to be stored and processed, all highly expensive operations in the long haul. In this paper we suggest that we can do computing and analysis of data "on the wire," i.e., while data is still in transit. The nature of these computations include analysis, visualization, pattern recognition, and prediction, or forecasting, on the streaming data. We follow a service function chaining architecture to implement this, assuming that the data packets arrive within a single network administrative domain. As a demonstration of this new computing paradigm, we present three examples. Firstly, we demonstrate pattern recognition and data visualization on streaming forex data, which can be used for lucrative trading in the forex market. In our second example, we analyze and learn user buying patterns from clickstream data streaming from multiple websites. Finally, we monitor solar sensors for a zero reading while the packets are still on their way to the data center, to schedule any maintenance and requisite repairs with no time delay.

97 MATHEMATICS AND COMPUTING↗

Three-Dimensional Imaging in Gynecologic Brachytherapy: A Survey of the American Brachytherapy Society

Purpose: To determine current practice patterns with regard to three-dimensional (3D) imaging for gynecologic brachytherapy among American Brachytherapy Society (ABS) members. Methods and Materials: Registered physician members of the ABS received a 19-item survey by e-mail in August 2007. This report excludes physicians not performing brachytherapy for cervical cancer. Results: Of the 256 surveys sent, we report results for 133 respondents who perform one or more implantations per year for locally advanced cervical cancer. Ultrasound aids 56% of physicians with applicator insertion. After insertion, 70% of physicians routinely obtain a computed tomography (CT) scan. The majority (55%) use CT rather than X-ray films (43%) or magnetic resonance imaging (MRI; 2%) for dose specification to the cervix. However, 76% prescribe to Point A alone instead of using a 3D-derived tumor volume (14%), both Point A and tumor volume (7%), or mg/h (3%). Those using 3D imaging routinely contour the bladder and rectum (94%), sigmoid (45%), small bowel (38%), and/or urethra (8%) and calculate normal tissue dose-volume histogram (DVH) analysis parameters including the D2cc (49%), D1cc (36%), D0.1cc (19%), and/or D5cc (19%). Respondents most commonly modify the treatment plan based on International Commission on Radiation Units bladder and/or rectal point dose values (53%) compared with DVH values (45%) or both (2%). Conclusions: More ABS physician members use CT postimplantation imaging than plain films for visualizing the gynecologic brachytherapy apparatus. However, the majority prescribe to Point A rather than using 3D image based dosimetry. Use of 3D image-based treatment planning for gynecologic brachytherapy has the potential for significant growth in the United States.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-BRF-07: Accuracy of Routine Treatment Planning 4D and DIBH CT Delineation of the Left Anterior Descending Artery in Radiotherapy

Purpose: To assess the feasibility of routine treatment planning 4DCT and deep inspiration breath-hold (DIBH) to accurately contour the left anterior descending artery (LAD), a primary indicator of cardiac toxicity, for radiotherapy treatment planning of breast cancer. Methods: Ten subjects were imaged with a cardiac-gated MRI protocol to determine the displacement of a ROI that included the LAD. The subjects performed a series of breath-hold maneuvers to obtain short-axis and radial views, which were resampled to create a 3D-volume. Tissue motion was determined using a multi-resolution 3D optical flow deformable image registration algorithm. The ROI motion was then used as a spatial boundary to characterize the blurring motion of the LAD in ten patients during clinical 4DCT and DIBH protocols. A radiologist contoured the LAD. Coronary motion-induced blurring artifacts were quantified by applying an unsharp filter to accentuate the LAD despite motion-blurring. The 4DCT maximum inhalation and exhalation respiratory phases were co-registered to determine the LAD displacement during tidal respiration, as visualized in 4DCT. Results: The average 90{sup th} percentile heart motion for the ROI was 0.7±0.1mm(LR), 1.3±0.6mm(SI), 0.6±0.2mm(AP) in the cardiac-gated MRI cohort. The average relative increase in the number of voxels comprising the LAD contour was 69.4±4.5% for the DIBH. During tidal respiration, the average relative increase in the LAD contour was 69.3±5.9% and 67.9±4.6% for inhalation and exhalation respiratory phases respectively. The average 90{sup th} percentile LAD motion was 4.8±1.1mm(LR), 0.9±0.4mm(SI), 1.9±0.6mm(AP) for the 4DCT cohort, in the absence of cardiac-gating. Conclusion: Uncompensated coronary motion was the dominant form of motion blurring present in the CT images due to the high frequency of the cardiac cycle relative to the respiratory cycle. The 4D and DIBH CT contour delineation of the LAD was consistently overestimated without cardiac-gating, which could have led to inaccurate dose volume histogram indicators in clinical practice.

60 APPLIED LIFE SCIENCES↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Mapping strain fields induced in Zr-based bulk metallic glasses during in-situ nanoindentation by X-ray nanodiffraction

A pioneer in-situ synchrotron X-ray nanodiffraction approach for characterization and visualization of strain fields induced by nanoindentation in amorphous materials is introduced. In-situ nanoindentation experiments were performed in transmission mode using a monochromatic and highly focused sub-micron X-ray beam on 40 μm thick Zr-based bulk metallic glass under two loading conditions. Spatially resolved X-ray diffraction scans in the deformed volume of Zr-based bulk metallic glass covering an area of 40 × 40 μm{sup 2} beneath the pyramidal indenter revealed two-dimensional map of elastic strains. The largest value of compressive elastic strain calculated from diffraction data at 1 N load was −0.65%. The region of high elastic compressive strains (<−0.3%) is located beneath the indenter tip and has radius of 7 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Provenance-Enabling DOE Visualization Applications

VisTrails, Inc.’s goal main charter has been to develop provenance management solutions for software tools. As the use of computation increases, keeping track of computational processes and the data they consume and derive is essential for many applications. Provenance (also referred to as audit trail, lineage, and pedigree) captures information about the steps used to generate a given data product. Such information provides important documentation that is key to preserving the data, to determining the data’s quality and authorship, and to reproducing as well as validating the results. Given the growing complexity of the computational processes and the volume of data they manipulate, manual approaches to maintaining provenance are both tedious and error-prone. At VisTrails, Inc., we have implemented infrastructure that can be used to provenance-enable existing tools. We have developed a series of plugins for specific applications, including ParaView and VisIt, which enable these applications to capture provenance. While developing these plugins, we identified general patterns across different applications, and these were used to inform the design of a general framework: the VisTrails Provenance Software Development Kit (SDK). The SDK encapsulates a set of core functionality including methods for capture, navigation, analysis and re-use of provenance. It allows application or plugin developers to more effectively provide provenance support: they can use the core functionality and write code only to handle application specific components. The SDK includes features that can be used in any application, for example, a refined interface for browsing the intermediate and final results captured. While the application-specific plugins were written in Python, the SDK was written from scratch in C++. This has led not only to substantial gains in performance but also the ability to integrate the SDK with applications written in other languages, including Java. To ensure that the SDK supported all of the functionality in the application-specific plugins, we have rewritten some of the existing plugins using the SDK. The SDK can be downloaded from www.vistrals.com/sdk.html.

97 MATHEMATICS AND COMPUTING↗

Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

36 MATERIALS SCIENCE↗

X-ray Spray Diagnostics: Comparing Sources and Techniques

Unveiling the internal structure of sprays for propulsion applications is difficult under conditions with high optical extinction. While a number of laser-based techniques have been utilized at intermediate to high optical densities of 2 to 4 (Log10 scale), it is difficult to extract quantitative information under these conditions. The ability of X-rays to penetrate even the most optically dense sprays has enabled quantitative investigation of liquid volume fractions for a variety of applications. Much of the development in this area has taken place utilizing the Advanced Photon Source at Argonne National Laboratory. This paper makes a comparison between two sources: including the bright, coherent, monochromatic, pulsed beam at the Advanced Photon Source and an incoherent, polychromatic, sealed-tube source at the X-ray Flow Visualization Facility at Iowa State University. Studies of dense sprays and static fluid samples were conducted at both facilities to compare performance characteristics of each source for a variety of operating conditions. Data for solid-cone and impinging-jet sprays are presented, and challenges with utilizing polychromatic, incoherent sources are discussed.

43 PARTICLE ACCELERATORS↗

Evaluation of Geologic Carbon Storage Resource Estimates (SREs) of Cambrian Ordovician Units within the CarbonSAFE Prefeasibility Study Region Subtasks 4.2 and 4.3 – Topical Report

This report by the Indiana Geological & Water Survey (IGWS) assessed the storage resource estimate (SRE) of Cambrian-Ordovician stratigraphic units located within the CarbonSAFE prefeasibility area within the Illinois Basin. A comprehensive data set of wireline logs and petrophysical information was used. These data include core analysis for porosity and permeability, and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for four potential storage reservoirs (Upper Ordovician Trenton Limestone/Black River Group, Middle Ordovician St. Peter Sandstone, Lower Ordovician and Upper Cambrian Knox Supergroup, including a separate assessment for the lower Knox Potosi Dolomite. The resultant SREs volumes are displayed using georeferenced maps and boxplots. The latter allow for comparing data statistics (mean values and variability) between five methods employed for the SRE calculations. Differences observed in SRE results from the five methods are mainly attributable to differences in the data used for porosity in each method. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Accurate Analysis of the Change in Volume, Location, and Shape of Metastatic Cervical Lymph Nodes During Radiotherapy

Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed in this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrafast three-dimensional x-ray computed tomography

X-ray computed tomography (CT) is a well established visualization technique in medicine and nondestructive testing. However, since CT scanning requires sampling of radiographic projections from different viewing angles, common CT systems with mechanically moving parts are too slow for dynamic imaging, for instance of multiphase flows or live animals. Here, we introduce an ultrafast three-dimensional x-ray CT method based on electron beam scanning, which achieves volume rates of 500 s{sup -1}. Primary experiments revealed the capability of this method to recover the structure of phase boundaries in gas-solid and gas-liquid two-phase flows, which undergo three-dimensional structural changes in the millisecond scale.

42 ENGINEERING↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗

SU-F-T-99: Data Visualization From a Treatment Planning Tracking System for Radiation Oncology

Purpose: A treatment planning process tracker database with input forms and a TV-viewable display webpage was developed and implemented in our clinic to collect time data points throughout the process. Tracking plan times is important because it directly affects the patient quality of care. Simply, the longer a patient waits after their initial simulation CT for treatment to begin, the more time the cancer has to progress. The tracker helps to drive workflow through the clinic, while the data collected can be used to understand and manage the process to find and eliminate inefficiencies. Methods: The overall process steps tracked are CT-simulation, mark patient, draw normal contours, draw target volumes, create plan, and review/approve plan. Time stamps for task completion were extracted and used to generate a set of clinic metrics, among which include average time for each step in the process split apart by type of treatment, average time to completion for plans started in a given week, and individual overall completion time per plan. Results: Trends have been tracked for fourteen weeks of clinical data (196 plans). On average, drawing normal contours and target volumes is taking 2–5 times as long as creating the plan itself. This is potentially an issue because it could mean the process is taking too long initially, and it could be forcing the planning step to be done in a short amount of time. We also saw from our graphs that there appears to be no clear trend on the average amount of time per plan week-to-week. Conclusion: A tracker of this type has the potential to provide insight into how time is utilized in our clinic. By equipping our dosimetrists, radiation oncologists, and physicists with individualized metric sets, the tracker can help provide visibility and drive workflow. Funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗