Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Nonradiative relaxation and laser action in tunable solid state laser crystals

Room-temperature pulsed laser action was obtained in chromium-activated forsterite (Cr:Mg2SiO4) for both 532 and 1064 nm pumping. Free running laser emission in both cases is centered at 1235 nm and has a bandwidth of approximately 30 nm. Slope efficiency as high as 22 percent was measured. Using different sets of output mirrors and a single birefrigent plate as the intracavity wavelength selecting element tunability over the 1167 to 1268 nm spectral range was demonstrated. Continuous wave laser operation at room temperature was obtained for 1064 nm pumping from a CW Nd:YAG laser. The output power slope efficiency is 6.8 percent. The gain cross section is estimated to be 1.1 x 10 to the 19th sq cm. Spectroscopic studies suggest that the laser action is due to a center other than the trivalent chromium (Cr 3+), presumably the tetravalent chromium (Cr 4+) in a tetrahedrally coordinated site.

Petricevic, V.↗

Integrated spectrum analyzer/wavemeter for pulsed, tunable lasers

A compact instrument for single shot spectrum analysis and real time wavelength measurement of pulsed, tunable lasers has been built. Its accuracy and limitations are discussed, along with its potential applications. Results of tests with a narrow-line Nd:YAG-pumped dye laser are also presented.

Cotnoir, Leo J.↗

Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns

A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.

May, R. D.↗

Tunable diode laser measurements of absolute line strengths in the 2nu2 band of N2O near 8 microns

The absolute intensities of five rotational transitions in the 2nu2 band of N2O near 8 microns have been measured with a tunable-diode laser-spectrometer. Measurements were reproducible within an average deviation of about 3 percent, and the experimental and calculated line strengths differed by only 1.5 percent. An analysis of the line strengths has yielded a band strength of S(v) = 6.98 + or - 0.26/sq cm per atm at 296 K. The band and line strengths are in excellent agreement with two recently reported values obtained by using Fourier transform-IR spectroscopy.

Tang, Lai-Wa↗

Tunable diode laser measurements of line widths in the nu1-fundamental band of (N-14)2(O-16) at atmospheric temperatures

A tunable diode-laser spectrometer and a low-temperature absorption cell have been employed to measure the N2-broadened and O2-broadened half-widths of rotational lines in the nu1 fundamental band of (N-14)2(O-16) at 185, 235, 263, and 295 K. The temperature dependence of the line widths has been observed to be practically identical, thereby leading to the suggestion that air-broadening would exhibit the same dependence.

Varanasi, P.↗

Frequency stability of a tunable diode laser mounted in a compact Stirling cycle cooler

A tunable diode laser (TDL) has been operated with a compact lightweight closed-cycle Stirling cooler. The laser linewidth has been measured near 80 K and found to be about half of that when using more massive closed-cycle coolers. Novel applications include balloon-borne and aircraft-adapted instruments, where size, weight, and power requirements place stringent demands on necessary TDL cooling systems.

Durso, Santo S.↗

Tunable-Quantum-Well Infrared Detector

Proposed detector of infrared photons based on photon-assisted, resonant quantum-mechanical tunneling between adjacent energy wells in its semiconductor structure. Wavelength adjusted by changing applied voltage. Device contains alternating layers of different seminconductors which form double-quantum-well electron-energy structure. Tunable-quantum-well detectors made on single chip constitutes line imager. Many such devices stacked to form two-dimensional imaging device. Signal-processing circuitry integrated into chip at its lower end. Potential barriers and wells produced by alternating layers of different semiconductor materials. Steepness of slope proportional to applied electric field. Electric field and thicknesses and heights of barriers selected to favor photon-assisted, resonant quantum-mechanical tunneling at chosen photon frequency.

Maserjian, Joseph↗

Tunable Quantum-Well Submillimeter-Wave Oscillators

Tunable submillimeter-wave generator is layered (AI/Ga)As device. Frequencies adjusted via applied voltages. New device concept offers potential to make relatively compact, efficient local oscillators for heterodyne mixers in submillimeter radar and imaging systems, nondestructive testing, diagnosis of plasmas, airborne spectroscopy of atmosphere, detection of weapons and other contraband, and communications.

Maserjian, Joseph↗

Tunable diode laser IR spectrometer for in situ measurements of the gas phase composition and particle size distribution of Titan's atmosphere

A new instrument, the Probe Infrared Laser Spectrometer (PIRLS), is described for in situ sensing of the gas composition and particle size distribution of Titan's atmosphere on the NASA/ESA Cassini mission. For gas composition measurements, several narrow-band (0.0001/cm) tunable lead-salt diode lasers operating near 80 K at selected mid-IR wavelengths are directed over a path length defined by a small reflector extending over the edge of the probe spacecraft platform; volume mixing ratios of 10 to the -9th should be measurable for several species of interest. A cloud-particle-size spectrometer using a diode laser source at 780 nm shares the optical path and deployed reflector; a combination of imaging and light scattering techniques is used to determine sizes of haze and cloud particles and their number density as a function of altitude.

Webster, Christopher R.↗

Computer processing of tunable diode laser spectra

A computer-controlled tunable diode laser spectrometer and spectral analysis software are described. The three-channel system records simultaneously the transmission of a subject gas, a temperature-stabilized etalon, and a calibration gas. The software routines are applied to diode laser spectra of HNO3 and NO2 to illustrate the procedures adopted for conversion of raw spectral data to useful transmission and harmonic spectra. Extraction of line positions, absorption intensities, collisional broadening coefficients, and gas concentrations from recorded spectra is also described.

May, Randy D.↗

Heterodyne spectrophotometry of ozone in the 9.6-micron band using a tunable diode laser

Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (0.0003/cm) solar spectra in the 9.6-micron ozone band. Observations have shown that a signal-to-noise ratio of 120:1 (about 30 percent of theoretical) for an integration time of 1/8 s can be achieved at a resolution of 0.0013 wave numbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that measured at the nearby NOAA ozone monitoring facility in Boulder, Colorado. Line positions for several ozone lines in the spectral region 996-997/cm are reported. Recent improvements have produced a signal-to-noise ratio of 95:1 (about 40 percent of theoretical) at 0.0003/cm and extended the range of wavelengths which can be observed.

Mcelroy, C. T.↗

Electrooptic modulation methods for high sensitivity tunable diode laser spectroscopy

A CdTe phase modulator and low power RF sources have been used with Pb-salt tunable diode lasers operating near 8 microns to generate optical sidebands for high sensitivity absorption spectroscopy. Sweep averaged, first-derivative sample spectra of CH4 were acquired by wideband phase sensitive detection of the electrooptically (EO) generated carrier-sideband beat signal. EO generated beat signals were also used to frequency lock the TDL to spectral lines. This eliminates low frequency diode jitter, and avoids the excess laser linewidth broadening that accompanies TDL current modulation frequency locking methods.

Glenar, David A.↗

A tunable diode laser system for aircraft measurements of trace gases

The advantages of tunable-diode-laser absorption spectrometry (TDLAS) for measuring trace atmospheric gases are universality, positive identification, good sensitivity, and rapid response time. A TDLAS system is described which is capable of making measurements aboard an aircraft. The instrument was employed during the Chemical Instrumentation Test and Evaluation (CITE) 2 program to measure NO2 on 11 flights and HNO3 on five flights. Detection limits were determined to be 25 parts per trillion by volume (pptv) for NO2 and 75 pptv for HNO3 with response times of 3 min. This was sufficient to permit measurements of NO2 in the free troposphere and HNO3 in the continental boundary layer a significant fraction of the time.

Schiff, H. I.↗

Tunable far-IR laser spectroscopy of jet-cooled carbon clusters - The nu-2 bending vibration of C3

Seven rovibrational transitions of the (01/1/0)-(00/0/0) fundamental bending band of C3 have been measured with high precision with the use of a tunable far-infrared laser spectrometer. The C3 molecules were produced by laser vaporization of a graphite rod and cooled in a supersonic expansion. The astrophysically important nu-2 fundamental frequency is determined to be 63.416529(40)/cm. These measurements provide the basis for studies of C3 in the interstellar medium with far-infrared astronomy.

Schmuttenmaer, C. A.↗

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.↗

Tunable far infrared studies of molecular parameters in support of stratospheric measurements

Lab studies were made in support of far infrared spectroscopy of the stratosphere using the Tunable Far InfraRed (TuFIR) method of ultrahigh resolution spectroscopy and, more recently, spectroscopic and retrieval calculations performed in support of satellite-based atmospheric measurement programs: the Global Ozone Monitoring Experiment (GOME), and the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY).

Chance, Kelly V.↗

Tunable diode laser absorption sensor for temperature and velocity measurements of O2 in air flows

A fast and nonintrusive velocity and temperature diagnostic based on oxygen absorption is presented. The system uses a GaAlAs tunable diode laser, ramped and modulated in wavelength at high frequency. Detection is performed at twice the modulating frequency, leading to second harmonic absorption lineshapes. Velocity is inferred from the wavelength shift of the absorption line center due to the Doppler effect. Temperature is determined by comparing experimental and calculated lineshapes. Capabilities of the technique for studies of transient high-speed flows are demonstrated in shock tube experiments. Good agreement is obtained with predicted temperatures and velocities when pressure-induced shifts are accounted for.

Philippe, L. C.↗

Atomic oxygen fine-structure splittings with tunable far-infrared spectroscopy

Fine-structure splittings of atomic oxygen (O-16) in the ground state have been accurately measured using a tunable far-infrared spectrometer. The 3P0-3pl splitting is 2,060,069.09 (10) MHz, and the 3Pl-3P2 splitting is 4,744,777.49 (16) MHz. These frequencies are important for measuring atomic oxygen concentration in earth's atmosphere and the interstellar medium.

Zink, Lyndon R.↗