Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmittance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Optical Characterization of Molecular Contaminant Films

A semi-empirical method of optical characterization of thin contaminant films on surfaces of optical components has been conceived. The method was originally intended for application to films that become photochemically deposited on such optical components as science windows, lenses, prisms, thinfilm radiators, and glass solar-cell covers aboard spacecraft and satellites in orbit. The method should also be applicable, with suitable modifications, to thin optical films (whether deposited deliberately or formed as contaminants) on optical components used on Earth in the computer microchip laser communications and thin-film industries. The method is expected to satisfy the need for a means of understanding and predicting the reductions in spectral transmittance caused by contaminant films and the consequent deterioration of performances of sensitive optical systems. After further development, this method could become part of the basis of a method of designing optical systems to minimize or compensate for the deleterious effects of contaminant films. In the original outer-space application, these deleterious effects are especially pronounced because after photochemical deposition, the films become darkened by further exposure to solar vacuum ultraviolet (VUV) radiation. In this method, thin contaminant films are theoretically modeled as thin optical films, characterized by known or assumed values of thickness, index of refraction, and absorption coefficient, that form on the outer surfaces of the original antireflection coating on affected optical components. The assumed values are adjusted as needed to make actual spectral transmittance values approximate observed ones as closely as possible and to correlate these values with amounts of VUV radiation to which the optical components have been exposed. In an initial study, the method was applied in correlating measured changes in transmittance of high-purity fused silica photochemically coated with silicone films of various measured thicknesses and exposed to various measured amounts of VUV radiation. In each case, it was found to be possible to select an index of refraction and absorption coefficient that made the ultraviolet, visible, and infrared transmittance changes predicted by the model match the corresponding measured transmittance changes almost exactly.

Visentine, James T.↗

TPSAS-NF1676L-11931-DND

Researchers at NASA Langley Research Center have developed an efficient, high repetition rate, pulsed, 2-µm coherent DIAL/IPDA transmitter for CO2 measurements. This transmitter will be employed to measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then measure both the atmospheric CO2 profiles (by DIAL) and column densities (by IPDA) from an airborne platform with the potential for measuring CO2 column density from a space-borne platform. The transmitter consists of a pulsed Q-switched ring-cavity Ho:YLF laser operating at 2.05 micron, being pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz with corresponding energy of 25 to 1 mJ, respectively. This transmitter can be used for direct or coherent detection of CO2 from ground, air or space-borne platform, as it is capable of providing required energy/repetition rate even from space platform. This presentation will describe the details of the injection-seeded highrepetition rate 2-micron transmitter and demonstrate its flexibility for direct or coherent detection of CO2.

Upendra N Singh↗

Methods and systems for determining soiling on photovoltaic devices

An aspect of the present disclosure relates to radiating light on to a front surface of a glass pane comprising a first surface and a second surface defining a thickness between the first surface and the second surface, wherein the first surface is substantially parallel to the second surface; detecting a transmittance of the light through the glass pane; comparing the transmittance through the glass pane to a reference transmittance value corresponding to a clean reference glass pane; and determining, using the transmittance and the reference transmittance, a soiling metric of a photovoltaic module.

14 SOLAR ENERGY↗

Fast All-sky Radiation Model for Solar applications (FARMS) 2023 [SWR-16-18]

The Fast All-sky Radiation Model for Solar applications (FARMS) is used to compute cloudy irradiance. Radiative transfer (RT) models simulating broadband solar radiation have been widely used by atmospheric scientists to model solar resources for various energy applications such as operational forecasting. Due to the complexity of solving the RT equation, the computation under cloudy conditions can be extremely time consuming though many approximations (e.g. two-stream approach and delta-M truncation scheme) have been utilized. Thus, a more efficient RT model is crucial for model developers as a new option for approximating solar radiation at the land surface with minimal loss of accuracy. We have developed a fast all-sky radiation model for solar applications (FARMS) using the simplified clear-sky RT model, REST2, and simulated cloud transmittances and reflectances from the Rapid Radiation Transfer Model (RRTM) with a sixteen-stream Discrete Ordinates Radiative Transfer (DISORT). Simulated lookup tables (LUTs) of cloud transmittances and reflectances were created by varying cloud optical thicknesses, cloud particle sizes, and solar zenith angles. Equations with optimized parameters were fitted to the cloud transmittances and reflectances to develop the model. Using this model the all-sky solar irradiance at the land surface can be computed rapidly by combining REST2 with the cloud transmittances and reflectances. This new RT model is more than 1000 times faster than those currently utilized in solar resource assessment and forecasting since it does not explicitly solve the RT equation for each individual cloud condition. Our results indicate the accuracy of the fast radiative transfer model is comparable to or better than two-stream approximation in term of computing cloud transmittance and solar radiation.

Xie, Yu↗

Influence of oxygen on the optical and electrical properties of magnetron-sputtered indium tin oxide thin films at ambient temperature

Indium Tin Oxide (ITO) thin films are commonly used as transparent conductive layers in the production of solar cells. ITO films are typically heat-treated at temperatures exceeding 200 °C after magnetron sputtering to optimize the physical, optical, and electrical characteristics for photovoltaic devices. Here, this high temperature heating procedure greatly limits the use of potential substrates, particularly those comprised of low-temperature-rated polymers. Herein, we examine the physical, optical, and electrical transport effects of oxygen:argon plasmas during radio frequency magnetron sputtering of ITO on glass and flexible polymer surfaces without subsequent heat treatment. ITO thin films were characterized via sheet resistance testing, UV-Vis spectroscopy, X-ray diffraction, and scanning electron microscopy imaging. Sheet resistance measurements revealed an increase in surface resistance with increasing oxygen concentration during sputtering. UV-Vis optical transmittance measurements demonstrated an improvement in optical transmittance with an increase in oxygen concentration reaching a maximum transmittance at an oxygen concentration of 1-2 %. Most importantly, it was discovered that producing bilayers of ITO with pure argon sputtered plasmas followed by oxygen:argon plasmas produced ITO thin films with suitable resistance and transmittance without the need for high temperature post annealing. These results highlight a methodology for the deposition of ITO thin films on temperature sensitive substrates for flexible photovoltaics and low-cost module production.

36 MATERIALS SCIENCE↗

Quasi-Dynamic Electromagnetic Field Safety Analysis and Mitigation for High-Power Dynamic Wireless Charging of Electric Vehicles

Dynamic wireless charging of electric vehicles (EV) is an emerging charging technology to enable non-contact wireless charging while the vehicle is moving. Compared to stationary wireless charging, in-motion wireless charging involves dynamic processes in which an EV is passing over the charging pads (transmitters). This in motion process makes the dynamic electromagnetic (EM) environment more complicated, and EM safety needs to be ensured under all circumstances. This is due to the fact that the entire vehicle body may be exposed to magnetic fields while the vehicle moves over the energized transmitter. This paper investigates several typical charging scenarios when EVs approach, pass over, and move away from the charging pads. Quasi-dynamic models, which are preliminarily verified by coils’ inductance measurements, are developed to analyze the dynamic process. Based on the quasi-dynamic analysis, shielding solutions are also studied to ensure EM safety for the dynamic wireless charging processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗

Vehicle Position Detection Based on Machine Learning Algorithms in Dynamic Wireless Charging

Dynamic wireless charging (DWC) has emerged as a viable approach to mitigate range anxiety by ensuring continuous and uninterrupted charging for electric vehicles in motion. DWC systems rely on the length of the transmitter, which can be categorized into long-track transmitters and segmented coil arrays. The segmented coil array, favored for its heightened efficiency and reduced electromagnetic interference, stands out as the preferred option. However, in such DWC systems, the need arises to detect the vehicle’s position, specifically to activate the transmitter coils aligned with the receiver pad and de-energize uncoupled transmitter coils. This paper introduces various machine learning algorithms for precise vehicle position determination, accommodating diverse ground clearances of electric vehicles and various speeds. Through testing eight different machine learning algorithms and comparing the results, the random forest algorithm emerged as superior, displaying the lowest error in predicting the actual position.

47 OTHER INSTRUMENTATION↗

Bio-medical telemetry: Sensing and transmitting biological information from animals to man

The application of small radio transmitters for monitoring biological activity in animals and humans is discussed. The microminiaturization of the electronic transmitters makes it possible for them to be swallowed and to operate within the body with no external connections. The small size also makes it possible for the transmitters to be surgically implanted or carried externally to monitor specific bodily functions. The use of satellites to monitor the activity of birds and animals carrying small transmitters is described. Photographs of birds, fish, and reptiles which were equipped with miniature electronic monitors are provided.

Mackay, S.↗

On the Feasibility of Efficient Multiamplitude Communication

Bandwidth constraints in earth-satellite communication systems force consideration of uncoded M-ary modulation to obtain increased data rates. M-ary phase shift keying (MPSK) at first glance seems most promising because of the high transmitter efficiency achieved through Class C operation. Multiple phase-and-amplitude modulation candidates such as quadrature amplitude shift keying (QASK) appear less promising because the transmitter must operate at lower efficiency (in linear or multimode operation). However, initial studies indicate that QASK offers significant raw dc-power savings over MPSK, despite the reduced transmitter efficiency. For example, at S-band both solid-state and traveling wave tube (TWT) QASK transmitters can provide a 3-dB average dc-power savings over comparable 16-ary phase shift keying (PSK) for the same bit rate and error probability. The reason for this savings is that QASK requires much less average signal-to-noise ratio than 16-ary PSK for the same error rate.

Smith, J. G.↗

Phased-array laser radar: Concept and application

The design and construction of a coaxial transmitter-receiver combination was investigated. Major emphasis was placed on simple permanent optical alignment, transmitter-receiver field of view matching, use of a pulsed gas laser as a transmitter maximum optical efficiency, complete digital control of data acquisition, and optical mount pointing and tracking. Also a means of expanding the coaxial transmitter-receiver concept to allow phased-array lidar, par-lidar was described.

Kadrmas, K. A.↗

Single and multichannel implanted telemetry systems.

Description of improved single-channel and multichannel telemetry systems designed for measurements of single and multiple physiological parameters, respectively, with adequate accuracy. The systems include a single-channel biopotential transmitter, a temperature transmitter, a pressure transmitter, and a multichannel transmitter for implant telemetric applications.

Sandler, H.↗

A narrowband, crystal controlled biomedical telemetry system.

A miniature, single-channel, crystal-controlled transmitter has been developed for biomedical applications. A narrow-band frequency modulation (plus or minus 7 kHz) of the RF is used to achieve maximum operating range with minimum transmitting power. The radiated power is limited to stay within the 50 microvolts/m at 15 m FCC requirement for low-power transmitters in the 88- to 108-MHz band. This technique offers a number of advantages. First only manufacturer's type approval is required for the device and the user does not need a license. Second maximum operating range can be achieved within the FCC power limitations by using a narrow-band that is consistent with the required medical information bandwidth. A third advantage in using the 88- to 108-MHz band is that the commercial FM stations are relatively widely spaced and carefully regulated so that by selecting the transmitter's frequency in the guard band between stations, minimum interference from other transmitter sources is encountered.

Westbrook, R. M.↗

Experiment definition phase shuttle laboratory LDRL-10.6 experiment

The 10.6 microns laser data relay link (LDRL 10.6) program was directed to applying optical communications to NASA's wideband data transmission requirements through the 1980's. The LDRL consists of a transmitter on one or more low earth orbit satellites with an elliptical orbit satellite receivers. Topics discussed include: update of the LDRL design control table to detail the transmitter optical chain losses and to incorporate the change to a reflective beam pre-expander; continued examination of the link establishment sequence, including its dependence upon spacecraft stability; design of the transmitter pointing and tracking control system; and finalization of the transmitter brassboard optical and mechanical design.

Source record↗

Models for infrared atmospheric radiation

Line and band models for infrared spectral absorption are discussed. Radiative transmittance and integrated absorptance of Lorentz, Doppler, and voigt line profiles were compared for a range of parameters. It was found that, for the intermediate path lengths, the combined Lorentz-Doppler (Voigt) profile is essential in calculating the atmospheric transmittance. Narrow band model relations for absorptance were used to develop exact formulations for total absorption by four wide band models. Several continuous correlations for the absorption of a wide band model were compared with the numerical solutions of the wide band models. By employing the line-by-line and quasi-random band model formulations, computational procedures were developed for evaluating transmittance and upwelling atmospheric radiance. Homogeneous path transmittances were calculated for selected bands of CO, CO2, and N2O and compared with experimental measurements. The upwelling radiance and signal change in the wave number interval of the CO fundamental band were also calculated.

Tiwari, S. N.↗

Biomedical ultrasonoscope

The combination of a "C" mode scan electronics in a portable, battery powered biomedical ultrasonoscope having "A" and "M" mode scan electronics, the latter including a clock generator for generating clock pulses, a cathode ray tube having X, Y and Z axis inputs, a sweep generator connected between the clock generator and the X axis input of the cathode ray tube for generating a cathode ray sweep signal synchronized by the clock pulses, and a receiver adapted to be connected to the Z axis input of the cathode ray tube. The "C" mode scan electronics comprises a plurality of transducer elements arranged in a row and adapted to be positioned on the skin of the patient's body for converting a pulsed electrical signal to a pulsed ultrasonic signal, radiating the ultrasonic signal into the patient's body, picking up the echoes reflected from interfaces in the patient's body and converting the echoes to electrical signals; a plurality of transmitters, each transmitter being coupled to a respective transducer for transmitting a pulsed electrical signal thereto and for transmitting the converted electrical echo signals directly to the receiver, a sequencer connected between the clock generator and the plurality of transmitters and responsive to the clock pulses for firing the transmitters in cyclic order; and a staircase voltage generator connected between the clock generator and the Y axis input of the cathode ray tube for generating a staircase voltage having steps synchronized by the clock pulses.

Lee, R. D.↗

Low-frequency radio navigation for the Army's Mobile Automated Field Instrumentation System /MAFIS/

The Jet Propulsion Laboratory is engaged in the early phases of conceptual, preliminary design, and feasibility demonstration studies leading to determination of a design and implementation of the Army's proposed Mobile Automated Field Instrumentation System (MAFIS). An overview is provided of the current design concept for an experimental radio navigation subsystem to be implemented in the field as a part of the MAFIS study effort. Objectives of MAFIS include mobility, field-ruggedness and longevity of equipment, and low acquisition and life-cycle costs. The navigation subsystem comprises a 4-station radio transmitter network, plus the navigation receivers, network monitoring receivers and communications links, and interface to the command/control 'central' for transmitter status monitoring. Attention is given to accuracy goals, radio propagation effects, transmitter arrangement, radio-frequency allocations, position initialization and lane resolution, and transmitter and receiver functions.

Wallis, D. E.↗

Comparison of modelled and empirical atmospheric propagation data

The radiometric integrity of TM thermal infrared channel data was evaluated and monitored to develop improved radiometric preprocessing calibration techniques for removal of atmospheric effects. Modelled atmospheric transmittance and path radiance were compared with empirical values derived from aircraft underflight data. Aircraft thermal infrared imagery and calibration data were available on two dates as were corresponding atmospheric radiosonde data. The radiosonde data were used as input to the LOWTRAN 5A code which was modified to output atmospheric path radiance in addition to transmittance. The aircraft data were calibrated and used to generate analogous measurements. These data indicate that there is a tendancy for the LOWTRAN model to underestimate atmospheric path radiance and transmittance as compared to empirical data. A plot of transmittance versus altitude for both LOWTRAN and empirical data is presented.

Schott, J. R.↗