Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The DUNE Near Detector

DUNE is a next-generation experiment aiming to provide precision measurements of neutrino oscillation parameters. It will detect neutrinos produced in the Long-Baseline Neutrino Facility beamline at Fermilab, using a Near Detector situated near the beam target where the neutrinos originate and a Far Detector located 1300 km away in South Dakota. A comparison of the spectra of neutrinos measured at the Far and the Near Detector will allow for the extraction of oscillation probabilities from which the oscillation parameters can be inferred. The specific role of the Near Detector is to serve as the experiment’s control: it will establish the no oscillation null hypothesis, measure and monitor the beam, constrain systematic uncertainties, and provide essential measurements of the neutrino interactions to improve models. The Near Detector complex will include three primary detector components: a liquid argon time projection chamber, a high-pressure gas time projection chamber and an on-axis beam monitor. The three detectors will serve important individual and overlapping functions, with two of them being also able to move transverse to the beam’s axis via the DUNE-PRISM program. The overall mission of the Near Detector, as well as the three sub-detectors’ unique capabilities and physics programs will be discussed in these proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Studies of the trigger performance of the ICARUS T600 detector at Fermilab

In recent years, experimental neutrino anomalies were reported: if confirmed, they could hint at the existence of additional sterile neutrino states participating in the mixing phenomenon. The future Short-Baseline Neutrino (SBN) project at Fermilab will pursue sterile neutrino searches, by exploiting three Liquid Argon (LAr) Time Projection Chamber (TPC) detectors located on-axis along the Booster Neutrino Beam (BNB). Aside from SBND and MicroBooNE, ICARUS will be the far detector and will also be interested by the NuMI beam (off-axis). The trigger system is a key component of the detector: it is based on the coincidence of prompt signals from scintillation light in the LAr-TPC (recorded by a system of PhotoMultiplier Tubes, PMTs) with the proton spill extraction of the beam. The present system exploits a majority-based logic and may be complemented by a trigger system based on adder boards, that add the analog signals of the PMTs in groups of 15. Triggering on the sum may help in identifying events closer to the TPC walls, in which there is plenty of light collected by few PMTs and for which the majority condition may not be satisfied. Many tests were carried out to characterize the adder boards, both on the hardware and software sides.

43 PARTICLE ACCELERATORS↗

On-line diagnosis of unrestricted faults

A formal model for the study of on-line diagnosis is introduced and used to investigate the diagnosis of unrestricted faults. A fault of a system S is considered to be a transformation of S into another system S' at some time tau. The resulting faulty system is taken to be the system which looks like S up to time tau, and like S' thereafter. Notions of fault tolerance error are defined in terms of the resulting system being able to mimic some desired behavior as specified by a system similar to S. A notion of on-line diagnosis is formulated which involves an external detector and a maximum time delay within which every error caused by a fault in a prescribed set must be detected. It is shown that if a system is on-line diagnosable for the unrestricted set of faults then the detector is at least as complex, in terms of state set size, as the specification. The use of inverse systems for the diagnosis of unrestricted faults is considered. A partial characterization of those inverses which can be used for unrestricted fault diagnosis is obtained.

Meyer, J. F.↗

Exploring AI/ML-based Real-time Anomaly Detection in DUNE for Supernova Burst Neutrinos

The Deep Underground Neutrino Experiment (DUNE) is currently under construction with far detectors consisting of 4 liquid argon time projection chamber (LArTPC) modules at SURF (South Dakota Underground Research Facility) and a near detector complex with neutrino beam production at Fermilab to unambiguously determine neutrino mass ordering, to discover and precisely measure Charge-Parity (CP) violation phase in leptonic sector, to search for Beyond Stand Model (BSM) physics, and to study solar and supernova burst neutrinos. Anomalies in this project are classified in three categories: new physics signals, supernova burst neutrinos, and detector malfunction. We report here on promising early studies toward an Artificial Intelligence/Machine Learning-based real-time anomaly detection system, using a prototype autoencoder model currently under development. Additionally, the current status of an improved model and its performance will be presented. The model will be evaluated not only for its sensitivity to supernova neutrinos, but also to BSM physics signals and detector malfunctions. We will also consider how such a real-time algorithm might be used in DUNE.

de Jonge, Anselm [Kirchhoff Inst. Phys.] (ORCID:00↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

Source record↗

Light Yield Calibration in MicroBooNE

The MicroBooNE detector is a Liquid Argon Time Projection Chamber (LArTPC) located along the Booster Neutrino Beam (BNB) at Fermilab. Its primary physics goal is to contribute to addressing the elusive short-baseline MiniBooNE low energy excess. MicroBooNE records and utilises both the ionisation charge and scintillation light produced inside the TPC to select and reconstruct neutrino interactions. The scintillation light collected using a plane of PhotoMultiplier Tubes (PMTs) is also used for accurate event timing and cosmic muon rejection with the latter being an important background for detectors, such as MicroBooNE, located on the surface. A good understanding of light modeling and its related systematic uncertainties is crucial to evaluate their impact on physics analyses. The experience acquired from MicroBooNE regarding how the stability of the scintillation light behaves and evolves during the 5 years of the primary physics run will be discussed as well as the calibration method used. This experience will help with understanding the physics of scintillation light in LArTPCs for the future long-running Short-Baseline Neutrino (SBN) and Deep Underground Neutrino Experiment (DUNE) programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency discriminator/phase detector

Circuit provides dual function of frequency discriminator/phase detector which reduces frequency acquisition time without adding to circuit complexity. Both frequency discriminators, in evaluated frequency discriminator/phase detector circuits, are effective two decades above and below center frequency.

Crow, R. B.↗

GRIS background reduction results using isotopically enriched Ge

The Gamma Ray Imaging Spectrometer (GRIS) was flown twice from Alice Springs, Australia, in the spring of 1992 for a total of 32 hr at float altitude. One of the seven Ge detectors was isotopically enriched (greater than 97% Ge-70). This was the first time an enriched-Ge detector was used for astrophysical observations. Because of its thick anticoincidence shield, the GRIS instrument background is dominated by internal beta-decay in the energy range of 200-1000 keV. Half of the contribution in this beta-decay 'hump' is due to neutron-activated Ge-74. In this energy range, GRIS observed a factor of 2 reduction in the background in the enriched detector, as predicted. In future instruments (e.g., INTEGRAL), with thicker anticoincidence shields and smaller apertures, the background reduction will be even larger. Three strong instrumental background lines (54, 67, and 139 keV) are also eliminated. The elimination of the first two is particularly important for cylotron line observations.

Barthelmy, S. D.↗

The EBIT Calorimeter Spectrometer: A New, Permanent User Facility at the LLNL EBIT

The EBIT Calorimeter Spectrometer (ECS) has recently been completed and is currently being installed at the EBIT facility at the Lawrence Livermore National Laboratory. The ECS will replace the smaller XRS/EBIT spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory. The new ECS spectrometer was built from the ground up to be a low maintenance, high performance microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 us event timing, and capable of uninterrupted acquisition sessions of over 70 hours at 50 mK. The XRSIEBIT program has been extremely successful, producing over two-dozen refereed publications on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility, with many more publications in preparation. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. This proposed future instrument would include a hybrid detector system with 0.8 eV resolution in the band from 0.1-1.0 keV, 2 eV from 0.1-10 keV, and 30 eV from 0.5-100 keV, with high quantum efficiency in each band. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES spectrometer.

Porter, S.↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗