Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Tracing Carbon Metabolism with Stable Isotope Metabolomics Reveals the Legacy of Diverse Carbon Sources in Soil

Tracking the metabolic activity of whole soil communities can improve our understanding of the transformation and fate of carbon in soils. For this work, we used stable isotope metabolomics to trace 13 C from nine labeled carbon sources into the water-soluble metabolite pool of an agricultural soil over time. Soil was amended with a mixture of all nine sources, with one source isotopically labeled in each treatment. We compared changes in the 13 C enrichment of metabolites with respect to carbon source and time over a 48-day incubation and contrasted differences between soluble sources (glucose, xylose, amino acids, etc.) and insoluble sources (cellulose and palmitic acid). Whole soil metabolite profiles varied singularly by time, while the composition of 13 C-labeled metabolites differed primarily by carbon source (R 2 = 0.68) rather than time (R 2 = 0.07), with source-specific differences persisting throughout incubations. The 13 C labeling of metabolites from insoluble carbon sources occurred slower than that from soluble sources but yielded a higher average atom percent (atom%) 13 C in metabolite markers of biomass (amino acids and nucleic acids). The 13 C enrichment of metabolite markers of biomass stabilized between 5 and 15 atom% 13 C by the end of incubations. Temporal patterns in the 13 C enrichment of tricarboxylic acid cycle intermediates, nucleobases (uracil and thymine), and by-products of DNA salvage (allantoin) closely tracked microbial activity. Our results demonstrate that metabolite production in soils is driven by the carbon source supplied to the community and that the fate of carbon in metabolites do not generally converge over time as a result of ongoing microbial processing and recycling.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Time Window and Spectral Measurement Options on Empirical Green’s Function Analysis Using DAS Array and Seismic Stations

The recorded seismic waveform is a convolution of event source term, path term, and station term. Removing high-frequency attenuation due to path effect is a challenging problem. Empirical Green’s function (EGF) method uses nearly collocated small earthquakes to correct the path and station terms for larger events recorded at the same station. However, this method is subject to variability due to many factors. Here, we focus on three events that were well recorded by the seismic network and a rapid response distributed acoustic sensing (DAS) array. Using a suite of high-quality EGF events, we assess the influence of time window, spectral measurement options, and types of data on the spectral ratio and relative source time function (RSTF) results. Increased number of tapers (from 2 to 16) tends to increase the measured corner frequency and reduce the source complexity. Extended long time window (e.g., 30 s) tends to produce larger variability of corner frequency. The multitaper algorithm that simultaneously optimizes both target and EGF spectra produces the most stable corner-frequency measurements. The stacked spectral ratio and RSTF from the DAS array are more stable than two nearby seismic stations, and are comparable to stacked results from the seismic network, suggesting that DAS array has strong potential in source characterization.

58 GEOSCIENCES↗

The web based monitoring project at the CMS experiment

The Compact Muon Solenoid is a large a complex general purpose experiment at the CERN Large Hadron Collider (LHC), built and maintained by many collaborators from around the world. Efficient operation of the detector requires widespread and timely access to a broad range of monitoring and status information. To the end the Web Based Monitoring (WBM) system was developed to present data to users located anywhere from many underlying heterogeneous sources, from real time messaging systems to relational databases. This system provides the power to combine and correlate data in both graphical and tabular formats of interest to the experimenters, including data such as beam conditions, luminosity, trigger rates, detector conditions, and many others, allowing for flexibility on the user’s side. This paper describes the WBM system architecture and describes how the system has been used from the beginning of data taking until now (Run1 and Run 2).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Response Prediction: Framing the problem.

Predicting the performance of radiation detection systems at field sites based on measured performance acquired under controlled conditions at test locations, e.g., the Nevada National Security Site (NNSS), remains an unsolved and standing issue within DNDO’s testing methodology. Detector performance can be defined in terms of the system’s ability to detect and/or identify a given source or set of sources, and depends on the signal generated by the detector for the given measurement configuration (i.e., source strength, distance, time, surrounding materials, etc.) and on the quality of the detection algorithm. Detector performance is usually evaluated in the performance and operational testing phases, where the measurement configurations are selected to represent radiation source and background configurations of interest to security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Web Based Monitoring in the CMS Experiment at CERN

The Compact Muon Solenoid (CMS) is a large and complex general purpose experiment at the CERN Large Hadron Collider (LHC), built and maintained by many collaborators from around the world. Efficient operation of the detector requires widespread and timely access to a broad range of monitoring and status information. To this end the Web Based Monitoring (WBM) system was developed to present data to users located anywhere from many underlying heterogeneous sources, from real time messaging systems to relational databases. This system provides the power to combine and correlate data in both graphical and tabular formats of interest to the experimenters, including data such as beam conditions, luminosity, trigger rates, detector conditions, and many others, allowing for flexibility on the user side. This paper describes the WBM system architecture and describes how the system was used during the first major data taking run of the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric Study of X-ray Energy Modulation for Depth Sensitive Backscatter Imaging

The technique of X-ray backscatter imaging has been studied for its applications in both medical imaging and nondestructive testing. The geometry and dimensionality of the detector system and photon source affect acquisition time, resolution, and signal to noise ratio (SNR) but the end result is still, at most, a 2D image. This is similar to transmission radiography with the difference being that the backscatter image has the benefit of requiring only single sided access to the object. Despite these physical limitations to the dimensions of a backscatter image, Towe and Jacobs showed that it is possible to obtain depth sensitive information (the third dimension in this case) by acquiring multiple images, each at a different X-ray tube voltage. By changing the average energy of the X-ray source, the penetration depth and therefore the signal which is generated from a backscatter design changes depending on the materials present in the object of interest. In order to further investigate the capabilities of depth sensitive X-ray backscatter imaging, a parametric study has been conducted on X-ray energy and its associated backscatter signal depth for materials relevant to medical imaging and non-destructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Imaging of Geothermal Faults from a Vertical DAS Fiber at Brady Hot Spring, NV USA

In March 2016, arguably the most ambitious 4D (3D space + over time) active-source seismic survey for geothermal exploration in the U.S. was acquired at Brady Natural Laboratory, outside Fernley, Nevada. The four-week experiment included 191 vibroseis source locations, and approximately 130 m of distributed acoustic sensing (DAS) in a vertical well, located at the southern end of the survey area. The imaging of the geothermal faults is done with reverse time migration of the DAS data for both P-P and P-S events in order to generate 3D models of reflectivity, which can identify subsurface fault locations. Three scenarios of receiver data are explored to investigate the reliability of the reflectivity models obtained: (1) Migration of synthetic P-P and P-S DAS data, (2) migration of the observed field DAS data and (3) migration of pure random noise to better assess the validity of our results. The comparisons of the 3D reflectivity models from these three scenarios confirm that sections of three known faults at Brady produce reflected energy observed by the DAS. Two faults that are imaged are ~1 km away from the DAS well; one of these faults (middle west-dipping) is well-constructed for over 400 m along the fault’s strike, and 300 m in depth. These results confirm that the DAS data, together with an imaging engine such as reverse time migration, can be used to position important geothermal features such as faults.

10 SYNTHETIC FUELS↗

Assessing the benefits of capacity payment, feed‐in‐tariff and time‐of‐use programme on long‐term renewable energy sources integration

Recently, demand response programmes (DRPs) have captured great attention in electric power systems. DRPs such as time‐of‐use (ToU) programme can be efficiently employed in the power system planning to reform the long‐term behaviour of the load demands. The composite generation expansion planning (GEP) and transmission expansion planning (TEP) known as composite GEP–TEP is of high significance in power systems to meet the future load demand of the system and also integrate renewable energy sources (RESs). In this regard, this study presents a dynamic optimisation framework for the composite GEP–TEP problem taking into consideration the ToU programme and also, the incentive‐based and supportive programmes. Accordingly, the performances of the capacity payment and feed‐in tariff mechanisms and the ToU programme in integrating RESs and reducing the total cost have been evaluated in this study. The problem has been formulated and solved as a standard two‐stage mixed‐integer linear programming model aimed at minimising the total costs. In this model, the ToU programme is applied and the results are fed into the expansion planning problem as the input. The proposed framework is simulated on the IEEE Reliability Test System to verify the effectiveness of the model and discuss the results obtained from implementing the mentioned mechanisms to support the RESs integration.

Javadi, Mohammad Sadegh↗

The origin of infrasonic ionosphere oscillations over tropospheric thunderstorms

Thunderstorms have been observed to introduce infrasonic oscillations in the ionosphere, but it is not clear what processes or which parts of the thunderstorm generate the oscillations. In this paper, we present a new technique that uses an array of ground-based GPS total electron content (TEC) measurements to locate the source of the infrasonic oscillations and compare the source locations with thunderstorm features to understand the possible source mechanisms. The location technique utilizes instantaneous phase differences between pairs of GPS-TEC measurements and an algorithm to best fit the measured and the expected phase differences for assumed source positions and other related parameters. In this preliminary study, the infrasound waves are assumed to propagate along simple geometric raypaths from the source to the measurement locations to avoid extensive computations. The located sources are compared in time and space with thunderstorm development and lightning activity. Sources are often found near the main storm cells, but they are more likely related to the downdraft process than to the updraft process. As a result, the sources are also commonly found in the convectively quiet stratiform regions behind active cells and are in good coincidence with extensive lightning discharges and inferred high-altitude sprites discharges.

58 GEOSCIENCES↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

CMS Web-Based Monitoring

With the growth in size and complexity of High Energy Physics experiments, and the accompanying increase in the number of collaborators spread across the globe, the importance of widely relaying timely monitoring and status information has grown. To this end, we present online Web Based Monitoring solutions from the CMS experiment at CERN. The web tools developed present data to the user from many underlying heterogeneous sources, from real time messaging system to relational databases. We provide the power to combine and correlate data in both graphical and tabular formats of interest to the experimentalist, with data such as beam conditions, luminosity, trigger rates, detector conditions and many others, allowing for flexibility on the user side. We also present some examples of how this system has been used during CMS commissioning and early beam collision running at the Large Hadron Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive Target and Ion Source Test Facilities at HRIBF

The test facilities at Oak Ridge National Laboratory s Holifield Radioactive Ion Beam Facility (HRIBF) devoted to testing radioactive ion beam targets and ion sources are described. Beginning in 1992 various capabilities have been developed to support the RIB research mission of HRIBF. These facilities provide direct measurements of release efficiency from target materials, yields (ions/sec and efficiency) and hold up times from target/ion source configurations. In addition, target/ion source configurations can be easily tested and retested after configuration changes to provide optimized operating parameters for new target materials and ion sources.

43 PARTICLE ACCELERATORS↗

Radio and gamma-ray properties of extragalactic jets from the TANAMI sample

The TANAMI program has been observing parsec-scale radio jets of southern (declination south of - 30°) γ-ray bright AGN, simultaneously with Fermi/LAT monitoring of their γ-ray emission, via high-resolution radio imaging with Very Long Baseline Interferometry techniques. In this paper, we present the radio and γ-rayproperties of the TANAMI sources based on one year of contemporaneous TANAMI and Fermi/LAT data. A large fraction (72%) of the TANAMI sample can be associated with bright γ-ray sources for this time range. Association rates differ for different optical classes with all BL Lacs, 76% of quasars, and just 17% of galaxies detected by the LAT. Upper limits were established on the γ-ray flux from TANAMI sources not detected by LAT. This analysis led to the identification of three new Fermi sources whose detection was later confirmed. The γ-ray and radio luminosities are related by L γ ∝ L r 0.89±0.04 . The brightness temperatures of the radio cores increase with the average γ-ray luminosity and the presence of brightness temperatures above the inverse Compton limit implies strong Doppler boosting in those sources. The undetected sources have lower γ/radio luminosity ratios and lower contemporaneous brightness temperatures. Finally, unless the Fermi/LAT-undetected blazars are much γ-ray-fainter than the Fermi/LAT-detected sources, their γ-ray luminosity should not be significantly lower than the upper limits calculated here.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed control system for parallel-connected DC boost converters

The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Explosion Detection and Infrasound Localization by Reverse Time Migration Using 3-D Finite-Difference Wave Propagation

Infrasound data are routinely used to detect and locate volcanic and other explosions, using both arrays and single sensor networks. However, at local distances (< km) topography often complicates acoustic propagation, resulting in inaccurate acoustic travel times leading to biased source locations when assuming straight-line propagation. Here we present a new method, termed Reverse Time Migration-Finite-Difference Time Domain (RTM-FDTD), that integrates numerical modeling into the standard RTM back-projection process. Travel time information is computed across the entire potential source grid via FDTD modeling to incorporate the effects of topography. The waveforms are then back-projected and stacked at each grid point, with the stack maximum corresponding to the likely source. We apply our method to three volcanoes with different network configurations, source-receiver distances, and topography. At Yasur Volcano, Vanuatu, RTM-FDTD locates explosions within ~20 m of the source and differentiates between multiple vents. RTM-FDTD produces a more accurate location for the two Yasur subcraters than standard RTM and doubles the number of detected events. At Sakurajima Volcano, Japan, RTM-FDTD locates the source within 50 m of the active vent despite notable topographic blocking. The RTM-FDTD location is similar to that from the Time Reversal Mirror method, but is more computationally efficient. Lastly, at Shishaldin Volcano, Alaska, RTM and RTM-FDTD both produce realistic source locations (<50 m) for ground-coupled airwaves recorded on a four-station seismic network. We show that RTM is an effective method to detect and locate infrasonic sources across a variety of scenarios, and by integrating numerical modeling, RTM-FDTD produces more accurate source locations and increases the detection capability.

58 GEOSCIENCES↗

Assembly of the Populus Microbiome Is Temporally Dynamic and Determined by Selective and Stochastic Factors

Recent work shows that the plant microbiome, particularly the initial assembly of this microbiome, influences plant health, survival, and fitness. Here, we characterize the initial assembly of the Populus microbiome across ten genotypes belonging to two poplar species in a common garden using 16S rRNA gene and ITS2 region amplicon sequencing of the leaf endosphere, leaf surface, root endosphere, and rhizosphere. We sampled these microbiomes three times throughout the first growing season and found that the composition of the microbiome changed dramatically over time across all plant-associated habitats and host genotypes. For archaea and bacteria, these changes were dominated by strong homogenizing selection (accounting for 29 to 62% of pairwise comparisons). However, fungal assembly was generally characterized by multiple ecological assembly processes (i.e., a mix of weak selective and dispersal processes). Interestingly, genotype, while a significant moderator of microbiome composition, generally explained less variation than sample date across plant-associated habitats. We defined a set of core genera that accounted for, on average, 36% of the microbiome. The relative abundance of this core community was consistent over time. Additionally, using source tracking modeling, we determined that new microbial taxa colonize from both aboveground and belowground sources, and combined with our ecological assembly null models, we found that both selective and dispersal processes explained the differences between exo- (i.e., leaf surface and rhizosphere) and endospheric microbiomes. Taken together, our results suggest that the initial assembly of the Populus microbiome is time-, genotype-, and habitat-dependent and is moderated by both selective and stochastic factors.

16S rRNA↗

Bubble masks for time-encoded imaging of fast neutrons.

Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is induced typically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gaps bubbles propagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

Brubaker, Erik↗

Characterization of a double-sided silicon strip detector autoradiography system

Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and detection efficiency were successfully measured for seven radionuclides. The system dead time was measured to be 59 μs, and FWHM for a {sup 58}Co line source was 154 ± 14 μm for the DSSD system and 343 ± 15 μm for the storage phosphor system. Separation of the contributions from {sup 125}I and {sup 131}I was performed on autoradiography images of tumor sections. Conclusions: This study has shown that a DSSD system can be beneficially applied for digital autoradiography with simultaneous multiradionuclide imaging capability. The system has a low background signal, ability to image both low and high activity samples, and a good energy resolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗