Pore Formation and Mobility Investigation (PFMI): Description and Initial Analysis of Experiments Conducted Aboard the International Space Station

Flow Visualization experiments on the controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The experimental samples were prepared on ground by filling glass tubes, 1 cm 1D and approximately 30 cm in length, with pure succinonitrile (SCN) under 450 millibar of nitrogen. Porosity in the samples arose from natural shrinkage, and in some cases by direct insertion of nitrogen bubbles, during solidification of the liquid SCN. The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus that is placed in the glovebox facility (GBX) aboard the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. During the experiments, the sample is first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. The temperatures in the sample are monitored by six in situ thermocouples. Real time visualization of the controlled directional melt back shows bubbles of different sizes initiating at the melt interface and, upon dislodging from the melting solid, migrating at different speeds into the temperature field ahead of them, before coming to rest. The thermocapillary flow field set up in the melt, ahead of the interface, is dramatic in the context of the large bubbles, and plays a major role in dislodging the bubble. A preliminary analysis of the observed bubble formation and mobility during melt back and its implication to future microgravity experiments is presented and discussed.

Grugel, R. N.↗

Bubble Formation and Transport during Microgravity Materials Processing: Model Experiments on the International Space Station

Flow Visualization experiments on the controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with pure succinonitrile (SCN) under 450 millibar of nitrogen. Porosity in the samples arose from natural shrinkage, and in some cases by direct insertion of nitrogen bubbles, during solidification of the liquid SCN. The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus that is placed in the glovebox facility (GBX) aboard the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. During the experiments, the sample is first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. The temperatures in the sample are monitored by six in situ thermocouples. Real time visualization of the controlled directional melt back shows bubbles of different sizes initiating at the melt interface and, upon dislodging from the melting solid, migrating at different speeds into the temperature field ahead of them, before coming to rest. The thermocapillary flow field set up in the melt, ahead of the interface, is dramatic in the context of the large bubbles, and plays a major role in dislodging the bubble. A preliminary analysis of the observed bubble formation and mobility during melt back and its implication to future microgravity experiments is presented and discussed.

Grugel, R. N.↗

Bubble Formation and Transport during Microgravity Materials Processing: Model Experiments on the International Space Station

Flow Visualization experiments on the controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with pure succinonitrile (SCN) under 450 millibar of nitrogen. Porosity in the samples arose from natural shrinkage, and in some cases by direct insertion of nitrogen bubbles, during solidification of the liquid SCN. The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus that is placed in the glovebox facility (GBX) aboard the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. During the experiments, the sample is first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. The temperatures in the sample are monitored by six in situ thermocouples. Real time visualization of the controlled directional melt back shows bubbles of different sizes initiating at the melt interface and, upon dislodging from the melting solid, migrating at different speeds into the temperature field ahead of them, before coming to rest. The thermocapillary flow field set up in the melt, ahead of the interface, is dramatic in the context of the large bubbles, and plays a major role in dislodging the bubble. A preliminary analysis of the observed bubble formation and mobility during melt back and its implication to future microgravity experiments is presented and discussed.

Grugel, R. N.↗

Bubble Formation and Transport during Microgravity Materials Processing: Model Experiments on the Space Station

Flow Visualization experiments on the controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with pure succinonitrile (SCN) under 450 millibar of nitrogen. Porosity in the samples arose from natural shrinkage, and in some cases by direct insertion of nitrogen bubbles, during solidification of the liquid SCN. The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus that is placed in the glovebox facility (GBX) aboard the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. During the experiments, the sample is first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. The temperatures in the sample are monitored by six in situ thermocouples. Real time visualization of the controlled directional melt back shows bubbles of different sizes initiating at the melt interface and, upon dislodging from the melting solid, migrating at different speeds into the temperature field ahead of them, before coming to rest. The thermocapillary flow field set up in the melt, ahead of the interface, is dramatic in the context of the large bubbles, and plays a major role in dislodging the bubble. A preliminary analysis of the observed bubble formation and mobility during melt back and its implication to future microgravity experiments is presented and discussed.

Grugel, R. N.↗

Practical and efficient magnetic heat pump

Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.

Brown, G. V.↗

Finite difference solution for transient radiative cooling of a conducting semitransparent square region

Transient solutions were obtained for a square region of heat conducting semitransparent material cooling by thermal radiation. The region is in a vacuum environment, so energy is dissipated only by radiation from within the medium leaving through its boundaries. The effect of heat conduction during the transient is to partially equalize the internal temperature distribution. As the optical thickness of the region is increased, the temperature gradients increase near the boundaries and corners, unless heat conduction is large. The solution procedure must provide accurate temperature distributions in these regions to prevent error in the calculated radiation losses. Two-dimensional numerical Gaussian integration is used to obtain the local radiative source term. A finite difference procedure with variable space and time increments is used to solve the transient energy equation. Variable spacing was used to concentrate grid points in regions with large temperature gradients.

Siegel, R.↗

The effect of stress on the migration of He gas bubbles under a thermal gradient in Fe by phase-field modeling

Here a phase-field model is parameterized to study the effect of elastic stresses on the migration of He gas bubbles in Fe under a temperature gradient. Stresses caused by the gas bubble pressure and residual stress in the Fe matrix are considered. The dependence of He bubble migration velocity on the magnitude of the residual stress, average temperature, temperature gradient, and bubble size is measured. In agreement with a theoretical model based on surface diffusion, simulation results demonstrate that He bubbles move towards the high temperature region with velocities in Fe that are orders of magnitude faster than previously reported in UO 2 . It is found that local stresses in the matrix caused by the He bubble have negligible effect on the bubble migration process; however, residual stresses in the Fe matrix, potentially caused by processing or irradiation, can modestly modify bubble kinetics through pressure dependence of the He diffusion coefficients. Compressive residual stress decreases diffusion coefficients for bulk and surface diffusion mechanisms, thus reducing the migration velocity of the gas bubble. In contrast, tensile residual stress increases the diffusion coefficients, resulting in an increase in the gas bubble migration velocity. This pressure dependence is also consistent with a theoretical model. This phase field model lays the foundation for analysis of bubble coalescence-induced fracture in He bubble-containing steels.

36 MATERIALS SCIENCE↗

Thermal-Structural Analysis of Sunshield Membranes

Future large infrared space telescopes, such as the James Webb Space Telescope (JWST), will require deployable sunshields to provide passive cooling for optics and instruments. Deployable sunshield structures for such applications typically consist of multiple thin-film membrane layers supported by deployable booms. The mechanical design of the sunshield must accommodate thermal strains due to layer-to-layer temperature differences as well as potentially large in-plane temperature gradients within individual film layers. This paper describes a thermal-structural analysis for predicting the stress state in a thin-film membrane subject to both mechanical thermal loads that could aid in the mechanical design of future sunshield structures. First the temperature field predicted by a thermal analysis is mapped to a structural finite element model, and then the structural response is predicted using a nonlinear static analysis. The structural model uses membrane elements in conjunction with a tension field material model to predict the response of the thin-film membrane layer. The tension field material model accounts for no-compression behavior associated with wrinkling and slackness. This approach was used to study the problem of a single membrane layer from the NASA reference concept for the JWST sunshield. Results from the analysis show that the membrane can experience a loss of tensile preload due to the presence of an in-plane temperature gradient representative of the cold-side layer temperature distribution predicted for the reference concept JWST.

Johnston, John↗

Thermocapillary migration of bubbles and droplets

A discussion is presented concerning the motion of droplets in a surrounding fluid induced by a temperature gradient. Such 'thermocapillary migration' may be characterized as the tangential stress at the interface that is induced by the temperature gradient's variation of interfacial tension, causing motion in the neighboring fluid both inside and outside the droplet. As a result, the droplet moves in the direction of the pole with the lower interfacial tension. An analysis is conducted in the creeping flow limit, for the case of small Marangoni number values. The method of matched asymptotic expansions is used for the solution of the field equations.

Subramanian, R. S.↗

Interpretation of electromagnetic modes in the sub-TAE frequency range in JET plasmas with elevated monotonic q-profiles

Recent JET deuterium experiments with an advanced tokamak scenario using an internal transport barrier (ITB) have been performed to clearly observe destabilized toroidicity-induced Alfvén eigenmodes (TAEs) by fast ions; interestingly, these also exhibit unstable electromagnetic (EM) perturbations in the sub-TAE frequency range. We identify such EM perturbations to be beta-induced ion temperature gradient (BTG) eigenmodes and not beta-induced Alfvén eigenmodes nor beta-induced Alfvén acoustic eigenmodes, which are often unstable in such high-beta plasmas with high-power neutral beam injection (NBI). The BTG modes are the most unstable modes due to the high thermal ion temperature gradient related to the ITB, high thermal ion temperature compared to thermal electron temperature (high T i /T⁠ e ), and a high ion beta regime. BTG mode experimental characteristics match the analytical theory, i.e., location in the vicinity of a rational magnetic surface with a low magnetic shear, mode frequency scaling with the ion diamagnetic frequency (⁠ω$^*_i$⁠), and a coupling among Alfvén and drift waves. We also perform linear gyrokinetic simulations with validated plasma profiles and equilibrium, and find a mode kinetically driven by thermal ions with similar characteristics as the experimental BTG modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geometrical evidence for dark matter: X-ray constraints on the mass of the elliptical galaxy NGC 720

We describe (1) a new test for dark matter and alternate theories of gravitation based on the relative geometries of the X-ray and optical surface brightness distributions and an assumed form for the potential, of the optical light, (2) a technique to measure the shapes of the total gravitating matter and dark matter of an ellipsoidal system which is insensitive to the precise value of the temperature of the gas and to modest temperature gradients, and (3) a new method to determine the ratio of dark mass to stellar mass that is dependent on the functional forms for the visible star, gas and dark matter distributions, but independent of the distance to the galaxy or the gas temperature. We apply these techniques to X-ray data from the ROSAT Position Sensitive Proportional Counter (PSPC) of the optically flattened elliptical galaxy NGC 720; the optical isophotes have ellipticity epsilon approximately 0.40 extending out to approximately 120 sec. The X-ray isophotes are significantly elongated, epsilon = 0.20-0.30 for semimajor axis a approximately 100 sec. The major axes of the optical and X-ray isophotes are misaligned by approximately 30 deg +/- 15 deg. Spectral analysis of the X-ray data reveals no evidence of temperature gradients or anisotropies and demonstrates that a single-temperature plasma (T approximately 0.6 keV) having subsolar heavy element abundances and a two-temperature model having solar abundances describe the spectrum equally well. Considering only the relative geometries of the X-ray and optical surface brightness distributions and an assumed functional form for the potential of the optical light, we conclude that matter distributed like the optical light cannot produce the observed ellipticities of the X-ray isophotes, independent of the gas pressure, the gas temperature, and the value of the stellar mass; this comparison assumes a state of quasi-hydrostatic equilibrium so that the three-dimensional surfaces of the gas emissivity trace the three-dimensional isopotential surfaces -- we discuss the viability of this assumption for NGC 720. Milgrom's Modification of Newtonian Dynamics (MOND) cannot dispel this manifestation of dark matter. Hence, geometrical considerations require, without mention of pressure or temperature, the presence of an extended, massive dark matter halo in NGC 720. Employing essentially the technique of Buote & Canizares (1992; Buote 1992) we use the shape of the X-ray surface brightness to constrain the shape of the total gravitating matter. The total matter is modeled as either an oblate or prolate spheriod of constant shape and orientation having either a Ferrers (rho approximately r(exp -n)) or Hernquist density. Assuming the X-ray gas is in hydrostatic equilibrium, we construct a model X-ray gas distribution for various temperature profiles. We determine the ellipticity of the total gravitating matter to be epsilon approximately 0.50-0.70. Using the single-temperature model we estimate a total mass approximately (0.41-1.4) x 10(exp 12) h(sub 80) solar mass interior to the ellipsoid of semimajor axis 43.6 h(sub 80) kpc. Ferrers densities as steep as r(exp -3) do not fit the data, but the r(exp -2) and Hernquist models yield excellent fits. We estimate the mass distributions of the stars and the gas and fit the dark matter directly. For a given gas equation of state and functional forms for the visible stars, gas, and dark matter, these models yield a distance-independent and temperature-independent measurement of the ratio of dark mass to stellar mass M(sub DM)/M(sub stars). We estimate a minimum M(sub DM)/M(sub stars) greater than or equal to 4 which corresponds to a total mass slightly greater than that derived from the single-temperature models for distance D = 20h(sub 80) Mpc.

Buote, David A.↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

Stellar model chromospheres. XIII - M dwarf stars

Single-component, homogeneous model chromospheres that are consistent with high-resolution profiles of the Ca II K line calibrated in surface flux units for three dMe and 2 dM stars observed at quiescent times are constructed. The models reveal several systematic trends. Large values of the ratio of T(min) to T(eff) are derived, indicating a large amount of nonradiative heating present in the upper photospheres of M dwarf stars. It is also found that the lower chromospheric temperature gradient is similar for all the M dwarf stars. Since for the models here the chromospheric K line emission strength is most sensitive to the total amount of chromospheric material present within the approximate temperature range T(min)-6000 K, increasing the emission strength is not simply due to increasing chromospheric temperature gradients. It is also found that both the electron density and electron temperature at one thermalization length in the K line below the top of the chromospheres are greater in the dMe stars than in the dM stars. The M dwarf models here have microturbulent velocities between 1 and 2 km/sec, which are much smaller than for solar chromosphere models.

Giampapa, M. S.↗

Thermal drawdown and late‐stage seismic‐slip fault reactivation in enhanced geothermal reservoirs

Abstract Late‐stage seismic slip in geothermal reservoirs has been shown as a potential mechanism for inducing seismic events of magnitudes to ~2.6 as late as two decades into production. We investigate the propagation of fluid pressures and thermal stresses in a prototypical geothermal reservoir containing a centrally located critically stressed fault from a doublet injector and withdrawal well to define the likelihood, timing, and magnitude of events triggered by both fluid pressures and thermal stresses. We define two bounding modes of fluid production from the reservoir. For injection at a given temperature, these bounding modes relate to either low‐ or high‐relative flow rates. At low relative dimensionless flow rates the pressure pulse travels slowly, the pressure‐driven changes in effective stress are muted, but thermal drawdown propagates through the reservoir as a distinct front. This results in the lowest likelihood of pressure‐triggered events but the largest likelihood of late‐stage thermally triggered events. Conversely, at high relative non‐dimensional flow rates the propagating pressure pulse is larger and migrates more quickly through the reservoir but the thermal drawdown is uniform across the reservoir and without the presence of a distinct thermal front, and less capable of triggering late‐stage seismicity. We evaluate the uniformity of thermal drawdown as a function of a dimensionless flow rate Q D that scales with fracture spacing s ( m ), injection rate q ( kg/s ), and the distance between the injector and the target point L ∗ ( Q D ∝ qs 2 / L ∗ ). This parameter enables the reservoir characteristics to be connected with the thermal drawdown response around the fault and from that the corresponding magnitude and timing of seismicity to be determined. These results illustrate that the dimensionless temperature gradient adjacent to the fault dT D / dx D is exclusively controlled by the factor Q D . More significantly, this temperature gradient correlates directly with both the likelihood and severity of triggered events, enabling the direct scaling of likely magnitudes and timing to be determined a priori and directly related to the characteristics of the reservoir. This dimensionless scaling facilitates design for an optimum Q D value to yield both significant heat recovery and longevity of geothermal reservoirs while minimizing associated induced seismicity.

Gan, Quan↗

Observation and characterisation of trapped electron modes in Wendelstein 7-X

In the past, quasi coherent (QC) modes were reported for nearly all tokamaks. The general definition describes modes as QC when the magnitude squared coherence is in the range of 0.3 to 0.6. QC modes are observed in the plasma core as well as in the plasma edge and can have quite different physical origins. The one in the core are observed in plasmas with low collisionality, where the electron temperature exceeds the ion temperature in the plasma core. This is the case for electron cyclotron heating in general. The origin of these modes are electrons trapped within a magnetic mirror, as reported in the past from various fusion devices. The so-called trapped-electron modes (TEMs) belong to drift wave instabilities and can be destabilized by electron-temperature gradients in the plasma core. From the diagnostic point of view, QC modes appear as fluctuations in electron density and temperature. Therefore, the microwave reflectometer is very well suited to monitor these modes. This paper describes experiments, conducted at the Wendelstein 7-X stellarator (W7-X), which aim at detecting QC modes at low wave numbers. A poloidal correlation reflectometer installed at W7-X, is able to measure low wave numbers ($k_\perp\unicode{x2A7D}{3.5}\,\textrm{cm}^{-1}$). For medium line-averaged densities ($\int n_\textrm{e}\unicode{x2A7D}{6 \times10^{19}}\,\textrm{m}^{-2}$) the plasma core is accessible for this diagnostic. For different magnetic configurations and plasma parameters, broad QC structures are observed in the coherence spectra. From the analysis of the rotation and the poloidal structure, these QC modes show the properties of electron-temperature-gradient driven TEMs. A linear relation between the mode velocity and the rotation frequency is found. The relation is uniform and confirms the nature of QC-mode observation as TEM in tokamaks, too.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulence-Driven Edge-Localized-Mode-Free High-Confinement Mode with Divertor Detachment in a Metal-Wall Tokamak

We report the first demonstration of a minute-scale, edge-localized-mode-free high-confinement plasma regime compatible with divertor partial detachment and enhanced pedestal performance in a metal-wall tokamak, the Experimental Advanced Superconducting Tokamak. This regime is enabled by a newly identified mechanism: during divertor partial detachment, reduced ionization and enhanced pumping in a closed divertor lead to less cooling of the pedestal by recycling neutrals and seeding impurities, resulting in an increased pedestal temperature gradient, which excites high-frequency broadband turbulence. Gyrokinetic simulations identify the high-frequency broadband turbulence as a temperature-gradient-driven trapped electron mode (𝜂 𝑒 -TEM), which drives outward transport of particles and heat, thereby maintaining the edge-localized-mode-free state. This pedestal regime is particularly promising for the International Thermonuclear Experimental Reactor, where the anticipated lower density gradient, reduced E×B shear, and lower collisionality in the pedestal will further facilitate 𝜂 𝑒 -TEM excitation. The achieved integrated scenario with a detached divertor and turbulence-dominated pedestal thus offers a compelling solution for managing heat loads and metal impurity sources for long-pulse high-performance operation in future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact furnace to support in situ neutron imaging of hydrogen dynamics in yttrium hydride moderators

A compact, nuclear microreactor that utilizes low-enriched uranium fuel is a promising solution to meet U.S. energy demands in nonconventional nuclear markets such as remote and decentralized energy grids. Yttrium hydride (YHx) is a potential moderator material for a microreactor design that reduces the amount of required fuel and provides superior retention of hydrogen at high reactor operating temperatures. Hydrogen diffusion properties in YHx are highly sought after for computer model validation and reactor prototyping. To characterize hydrogen diffusion, a compact dual-zone furnace was developed at Los Alamos National Laboratory and analyzed via neutron imaging at the Los Alamos Neutron Science Center (LANSCE). The goal of these measurements is to assess hydrogen diffusion in YHx samples as a function of applied temperature gradients. Included herein is recent progress in technique and furnace developments as well as initial results from concentration- and temperature-gradient measurements at LANSCE.

Torres, James↗

Measuring nanoscale thermal gradients in suspended MoS2 with STEM-EELS

Transition metal dichalcogenides such as molybdenum disulfide (MoS2) may see service in the heart of next-generation nanoelectronic devices, where highly localized power dissipation can produce nontrivial temperature gradients over nanometer-scale distances. Here, we demonstrate that MoS2 is a promising target for plasmon energy expansion thermometry (PEET), a high-spatial resolution temperature mapping technique employed in a scanning transmission electron microscope (STEM) equipped with electron energy loss spectroscopy (EELS). We first use a calibrated, commercial MEMS-style TEM sample heater chip to measure the temperature dependence of the MoS2 bulk plasmon. We corroborate the chip's temperature calibration with Raman thermometry and determine the bulk thermal expansion coefficient (TEC) of MoS2 in the temperature range of 300–1100 K. Applying this TEC value to PEET measurements on a suspended MoS2 flake, we map 70–90 K/μm temperature gradients with a submicrometer spatial resolution.