Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Libby Mitigation Program, 2007 Annual Progress Report: Mitigation for the Construction and Operation of Libby Dam.

Libby Reservoir was created under an International Columbia River Treaty between the United States and Canada for cooperative water development of the Columbia River Basin (Columbia River Treaty 1964). Libby Reservoir inundated 109 stream miles of the mainstem Kootenai River in the United States and Canada, and 40 miles of tributary streams in the U.S. that provided habitat for spawning, juvenile rearing, and migratory passage (Figure 1). The authorized purpose of the dam is to provide power (91.5%), flood control (8.3%), and navigation and other benefits (0.2%; Storm et al. 1982). The Pacific Northwest Power Act of 1980 recognized possible conflicts stemming from hydroelectric projects in the northwest and directed Bonneville Power Administration to 'protect, mitigate, and enhance fish and wildlife to the extent affected by the development and operation of any hydroelectric project of the Columbia River and its tributaries' (4(h)(10)(A)). Under the Act, the Northwest Power Planning Council was created and recommendations for a comprehensive fish and wildlife program were solicited from the region's federal, state, and tribal fish and wildlife agencies. Among Montana's recommendations was the proposal that research be initiated to quantify acceptable seasonal minimum pool elevations to maintain or enhance the existing fisheries (Graham et al. 1982). Research to determine how operations of Libby Dam affect the reservoir and river fishery and to suggest ways to lessen these effects began in May 1983. The framework for the Libby Reservoir Model (LRMOD) was completed in 1989. Development of Integrated Rule Curves (IRCs) for Libby Dam operation was completed in 1996 (Marotz et al. 1996). The Libby Reservoir Model and the IRCs continue to be refined (Marotz et al 1999). Initiation of mitigation projects such as lake rehabilitation and stream restoration began in 1996. The primary focus of the Libby Mitigation project now is to restore the fisheries and fish habitat in basin streams and lakes. 'Mitigation for the Construction and Operation of Libby Dam' is part of the Northwest Power and Conservation Council's (NPCC) resident fish and wildlife program. The program was mandated by the Northwest Planning Act of 1980, and is responsible for mitigating damages to fish and wildlife caused by hydroelectric development in the Columbia River Basin. The objective of Phase I of the project (1983 through 1987) was to maintain or enhance the Libby Reservoir fishery by quantifying seasonal water levels and developing ecologically sound operational guidelines. The objective of Phase II of the project (1988 through 1996) was to determine the biological effects of reservoir operations combined with biotic changes associated with an aging reservoir. The objectives of Phase III of the project (1996 through present) are to implement habitat enhancement measures to mitigate for dam effects, to provide data for implementation of operational strategies that benefit resident fish, monitor reservoir and river conditions, and monitor mitigation projects for effectiveness. This project completes urgent and high priority mitigation actions as directed by the Kootenai Subbasin Plan.

13 HYDRO ENERGY↗

HC-NIDS: signatures and simulations for detecting cyber-attacks aiming to cause damage against cyber-physical energy systems

Physical device safety is typically implemented locally using embedded controllers, while operations safety is primarily performed in control centers. Safe operations can be enhanced by correct design of device-level control algorithms, and protocols, procedures and operator training at the control-room level, but all can fail. Moreover, these elements exchange data and issue commands via vulnerable communication layers. In order to secure these gaps and enhance operational safety, we believe monitoring of command sequences must be combined with an awareness of physical device limitations and automata models that capture safety mechanisms. One way of doing this is by leveraging specification-based intrusion detection to monitor for physical constraint violations. The method can also verify that physical infrastructure state is consistent with monitoring information and control commands exchanged between field devices and control centers. This additional security layer enhances protection from both outsider attacks and insider mistakes. We implemented specification-based SCADA command analyzers using physical constraint algorithms directly in the Bro framework and Broccoli APIs for three separate scenarios: a water heater, an automated distribution system, and an over-current protection scheme. To accomplish this, we added low-level analyzers capable of examining control system-specific protocol packets for both Modbus TCP and DNP3, and also higher-level analyzers able to interpret device command and data streams within the context of each device's physical capabilities and present operational state. Thus the software that we are making available includes the Bro/Broccoli scripts for these three scenarios, as well as simulators, written in C, of those scenarios that generate sample traffic that is monitored by the Bro/Broccoli scripts. In addition, we have also implemented systems to directly pull cyber-physical information from the OSIsoft PI historian system. We have included the Python scripts used to perform that monitoring.

Source record↗

HC-NIDS: signatures and simulations for detecting cyber-attacks aiming to cause damage against cyber-physical energy systems

Physical device safety is typically implemented locally using embedded controllers, while operations safety is primarily performed in control centers. Safe operations can be enhanced by correct design of device-level control algorithms, and protocols, procedures and operator training at the control-room level, but all can fail. Moreover, these elements exchange data and issue commands via vulnerable communication layers. In order to secure these gaps and enhance operational safety, we believe monitoring of command sequences must be combined with an awareness of physical device limitations and automata models that capture safety mechanisms. One way of doing this is by leveraging specification-based intrusion detection to monitor for physical constraint violations. The method can also verify that physical infrastructure state is consistent with monitoring information and control commands exchanged between field devices and control centers. This additional security layer enhances protection from both outsider attacks and insider mistakes. We implemented specification-based SCADA command analyzers using physical constraint algorithms directly in the Bro framework and Broccoli APIs for three separate scenarios: a water heater, an automated distribution system, and an over-current protection scheme. To accomplish this, we added low-level analyzers capable of examining control system-specific protocol packets for both Modbus TCP and DNP3, and also higher-level analyzers able to interpret device command and data streams within the context of each device's physical capabilities and present operational state. Thus the software that we are making available includes the Bro/Broccoli scripts for these three scenarios, as well as simulators, written in C, of those scenarios that generate sample traffic that is monitored by the Bro/Broccoli scripts. In addition, we have also implemented systems to directly pull cyber-physical information from the OSIsoft PI historian system. We have included the Python scripts used to perform that monitoring.

Source record↗

Copper and bismuth-based sorbent characterization in simulated iodine off-gas streams

The effective capture of volatile radioiodine, a fission product present in used nuclear fuel (UNF), is of paramount importance for development of used fuel reprocessing schemes to prevent release of radioiodine during unit operations and to meet regulatory standards for air emissions. A well-studied method for iodine capture in off-gas streams is the use of silver-functionalized zeolite phases (AgZ), which exploit chemisorption of I to Ag. Advances into other Ag-functionalized materials, including aerogels and metal organic frameworks (MOFs), are underway [1]. Additional metals with the capability to chemisorb iodine, including Cu, Bi, and Sn, [1] are being evaluated as alternatives to Ag for potential applicability to iodine management in off-gas systems. The design of novel functionalized sorbents with Cu and Bi, including composites with metal particles embedded in PAN substrates [2] and composites with metal sulfides embedded in PAN [3], is an ongoing area of study for improved iodine capture. Previously reported work on novel PAN-based metal sorbents has provided the synthesis, characterization, and iodine capture efficiency of this new class of sorbent. Specifically, the metal sulfide PAN composites are found to be easy to produce and reproduce, as well as having a high iodine loading potential under static conditions [3]. Due to the favorable testing previously performed with metal sulfide PAN composites, further testing into the performance of these composites under gas streams containing I2(g) in combination with NO2(g) and H2O(g) is needed. Humid streams of NO2(g) may arise from dissolver off-gas streams, when used fuel is dissolved in HNO3(aq) [4]. NO2(g) has been found to reduce AgZ sorption capacity for I because of oxidation of Ag, the chemisorbing agent, to Ag2O [5]. It follows that performance evaluation of novel sorbents under highly oxidizing conditions such as NO2(g) streams is critical. Therefore, the objective of this study is to determine the effect of flowing NO2(g) and H2O(g) streams on iodine sorption capacity and sorbent performance. This work utilizes custom-built gas handling capabilities for sorbent exposure along with solid-state characterization techniques to assess the physical and chemical properties of sorbents before and after exposure.

copper, bismuth, iodine capture, iodine sorbent, p↗

Testing of an Iodine and Tritium Removal System for Advanced Tritium Pretreatment Off-Gas

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas of a processing plant, including 3 H, 14 C, 85 Kr, and 129 I. For a reprocessing plant sited within the United States and governed by US regulations, the abatement of some or all of these radionuclides from the plant off-gas would be required before discharge of that gas to the environment. A potential simplification of the off-gas management system can be achieved through an efficient advanced tritium pretreatment (ATPT) step in which the UO 2 fuel is oxidized by NO 2 prior to dissolution. Oxidation of the UO 2 fuel matrix results in the release of tritium contained within. Up-front removal of tritium from the fuel in a pretreatment step, followed by the abatement of tritium from the advanced tritium pretreatment off-gas (ATPTOG) stream, can minimize or eliminate the distribution of tritium throughout the plant, also decreasing or eliminating the need for tritium capture on multiple off-gas streams. The use of NO 2 as the oxidant allows tritium pretreatment to be performed at lower temperatures and may result in the quantitative release of iodine from the fuel. A total of five tests examined AgA as a potential iodine sorbent at an operating temperature of 150°C and both 3A MS and silica gel as potential tritium sorbents with an operating temperature of 40°C. 3A MS and silica gel are intended for use as regenerative sorbents, in which the adsorbed tritium (as tritiated water or tritiated nitric acid) is loaded onto the sorbent at operating temperature and then subsequently desorbed at high temperature into a small-volume gas stream for recovery and conversion to a waste form. This testing leaves many fundamental questions regarding the ATPTOG iodine and tritium abatement systems unanswered. These include questions regarding sorbent capacity and sorbate desorption. Overall, this testing indicates that tritium and iodine abatement from an ATPTOG stream by solid sorbents is currently at a low stage of technological development and that deployment of such an abatement system would require substantial additional research and development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acceleration of Streamed Tensor Contraction Expressions on GPGPU-based Clusters

Tensor contractions are generalized multidimensional matrix multiplication operations that widely occur in quantum chemistry. Efficient execution of tensor contractions on GPUs requires tackling several challenges to be addressed, including index permutation and small dimension-sizes reducing thread block utilization. In this paper, we present our approach to automatically generate CUDA code to execute tensor contractions on GPUs, including management of data movement between CPU and GPU. GPU-enabled code is generated for the most expensive contractions in CCSD(T) and incorporated into NWChem, a popular computational chemistry suite. We demonstrate speedup over a factor of 8.4 using one core per node and over 2.6 when utilizing the entire system using hybrid CPU+GPU solution with 2 GPUs and 5 cores. We finally analyze the behavior of the application on future GPU systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

BETO 2021 Peer Review - Process Monitoring and Predictions of Biorefinery Performance

Online process monitoring coupled with rapid predictive tools will be essential to refineries of the future to provide real-time feedback and process control on new, renewable feeds and their accompanying processes and products. This project will provide refinery operators with tools to predict product component concentrations in minutes from online, slip stream mass spectra, allowing for rapid detection of off-specification product. We will arrive at a template for predictive tool generation through the development of a specific tool as a starting point -- co-processing of pyrolysis oils and vacuum gas oil over fluid catalytic cracking (FCC) catalysts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Disentangling Beam Losses in The Fermilab Main Injector Enclosure Using Real-Time Edge AI

The Fermilab Main Injector enclosure houses two accelerators, the Main Injector and Recycler Ring. During normal operation, high intensity proton beams exist simultaneously in both. The two accelerators share the same beam loss monitors (BLM) and monitoring system. Deciphering the origin of any of the 260 BLM readings is often difficult. The (Accelerator) Real-time Edge AI for Distributed Systems project, or READS, has developed an AI/ML model, and implemented it on fast FPGA hardware, that disentangles mixed beam losses and attributes probabilities to each BLM as to which machine(s) the loss originated from in real-time. The model inferences are then streamed to the Fermilab accelerator controls network (ACNET) where they are available for operators and experts alike to aid in tuning the machines.

43 PARTICLE ACCELERATORS↗

Design and characterization of an electromagnetic-resonant cavity microwave plasma reactor for atmospheric pressure carbon dioxide decomposition

Plasma processes are ideally suited for the conversion of renewable electricity into gas-phase reactivity, such as for the decomposition of carbon dioxide (CO 2 ). The design, development, and characterization of a microwave plasma reactor for atmospheric pressure undiluted carbon dioxide decomposition are presented. The reactor operates as an electromagnetic-resonant cavity in which the generated plasma forms a bulb attached to a converging-diverging nozzle and stabilized by streams of tangentially-injected processing gas. Electromagnetic wave confinement, residence time, and critical gas vorticity constitute fundamental reactor sizing and operation parameters. Experimental findings demonstrate that flow rate plays a dual role in plasma stabilization and process performance, whereas deposited power has a minor role in CO 2 decomposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Achieving Accelerated Cleanup of Cesium Contaminated Stream at the Savannah River Site; Collaboration between Stakeholders, Regulators, and the Federal Government - 13182

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina that contains six primary stream/river systems. The Lower Three Runs Stream (LTR) is one of the primary streams within the site that is located in the southeast portion of the Savannah River Site and is a large black water stream system that originates in the northeast portion of SRS and follows a southerly direction before it enters the Savannah River. During reactor operations, secondary reactor cooling water, storm sewer discharges, and miscellaneous wastewater was discharged and contaminated a 36 kilometer stretch of Lower Three Runs Stream that narrows providing a limited buffer of US DOE property along the stream and flood plain. Based on data collected during 2009 and 2010 under Recover Act Funding, the stream was determined to be contaminated with cesium-137 at levels that exceeded acceptable risk based limits. As efficiencies were realized within the SRS Recovery Act Program, funding was made available to design, permit and execute remediation of the LTR. This accelerated Project allowed for the remediation of 36 kilometers of LTR in only nine months from inception to completion, contributing significantly to the Foot Print Reduction of SRS. The scope consisted of excavation and disposal of more than 2064 cubic meters of contaminated soil, and installing 11 kilometers of fence and 2,000 signs at 1000 locations. Confirmatory sampling and analysis, and radiological surveying were performed demonstrating that soil concentrations met the cleanup goals. The project completed with a very good safety record considering the harsh conditions including, excessive rain in the early stages of the project, high summer temperatures, swampy terrain, snakes, wild boar, insects and dense vegetation. The regulatory approval process was compressed by over 75% and required significant efforts from SRS's stakeholders including the regulators, U. S. Environmental Protection Agency (US EPA) and the South Carolina Department of Health and Environmental Control (SCDHEC), and the public including local property owners and the SRS Citizens Advisory Board. Stakeholder buy-in was critical in the up-front planning in order to achieve this challenging cleanup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lower Three Runs Remediation Safety Preparation Strategy - 13318

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina that contains six primary stream/river systems. The Lower Three Runs Stream (LTR) is one of the primary streams within the site that is located in the southeast portion of the Savannah River Site. It is a large blackwater stream system that originates in the northeast portion of SRS and follows a southerly direction before it enters the Savannah River. During reactor operations, secondary reactor cooling water, storm sewer discharges, and miscellaneous wastewater was discharged and contaminated a 20 mile stretch of Lower Three Runs Stream that narrows and provides a limited buffer of US DOE property along the stream and flood-plain. Based on data collected during the years 2009 and 2010 under American Recovery and Re-investment Act funding, the stream was determined to be contaminated with cesium-137 at levels that exceeded acceptable risk based limits. In agreement with the Environmental Protection Agency and the South Carolina Department of Health and Environmental Control, three areas were identified for remediation [1] (SRNS April 2012). A comprehensive safety preparation strategy was developed for safe execution of the LTR remediation project. Contract incentives for safety encouraged the contractor to perform a complete evaluation of the work and develop an implementation plan to perform the work. The safety coverage was controlled to ensure all work was observed and assessed by one person per work area within the project. This was necessary due to the distances between the fence work and three transects being worked, approximately 20 miles. Contractor Management field observations were performed along with DOE assessments to ensure contractor focus on safe performance of the work. Dedicated ambulance coverage for remote worker work activities was provided. This effort was augmented with access to medical evacuation services. The areas where the work was performed were remote and difficult to get emergency vehicles to in a timely manner in case of an accident. Satellite phones were utilized due to intermittent phone coverage. High visibility vests were utilized to enable any hunters in the area to see the workers; due to the limited buffer areas along the stream route. An innovative approach to providing the necessary protection for workers during periods of extreme heat and humidity was also employed, which included the use of 'heat islands' with fans and crew trailers and ice vests for workers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report: Effects of Impurities on Fuel Cell Performance and Durability

The main objectives of this project were to investigate the effect of a series of potential impurities on fuel cell operation and on the particular components of the fuel cell MEA, to propose (where possible) mechanism(s) by which these impurities affected fuel cell performance, and to suggest strategies for minimizing these impurity effects. The negative effect on Pt/C was to decrease hydrogen surface coverage and hydrogen activation at fuel cell conditions. The negative effect on Nafion components was to decrease proton conductivity, primarily by replacing/reacting with the protons on the Bronsted acid sites of the Nafion. Even though already well known as fuel cell poisons, the effects of CO and NH3 were studied in great detail early on in the project in order to develop methodology for evaluating poisoning effects in general, to help establish reproducibility of results among a number of laboratories in the U.S. investigating impurity effects, and to help establish lower limit standards for impurities during hydrogen production for fuel cell utilization. New methodologies developed included (1) a means to measure hydrogen surface concentration on the Pt catalyst (HDSAP) before and after exposure to impurities, (2) a way to predict conductivity of a Nafion membranes exposed to impurities using a characteristic acid catalyzed reaction (methanol esterification of acetic acid), and, more importantly, (3) application of the latter technique to predict conductivity on Nafion in the catalyst layer of the MEA. H2-D2 exchange was found to be suitable for predicting hydrogen activation of Pt catalysts. The Nafion (ca. 30 wt%) on the Pt/C catalyst resides primarily on the external surface of the C support where it blocks significant numbers of micropores, but only partially blocks the pore openings of the meso- and macro-pores wherein lie the small Pt particles (crystallites). For this reason, even with 30 wt% Nafion on the Pt/C, few Pt sites are blocked and, hence, are accessible for hydrogen activation. Of the impurities studied, CO, NH3, perchloroethylene (also known as tetrachloroethylene), tetrahydrofuran, diborane, and metal cations had significant negative effects on the components in a fuel cell. While CO has no effect on the Nafion, it significantly poisons the Pt catalyst by adsorbing and blocking hydrogen activation. The effect can be reversed with time once the flow of CO is stopped. NH3 has no effect on the Pt catalyst at fuel cell conditions; it poisons the proton sites on Nafion (by forming NH4+ cations), decreasing drastically the proton conductivity of Nafion. This poisoning can slowly be reversed once the flow of NH3 is stopped. Perchloroethylene has a major effect on fuel cell performance. Since it has little/no effect on Nafion conductivity, its poisoning effect is on the Pt catalyst. However, this effect takes place primarily for the Pt catalyst at the cathode, since the presence of oxygen is very important for this poisoning effect. Tetrahydrofuran was shown not to impact Nafion conductivity; however, it does affect fuel cell performance. Therefore, its primary effect is on the Pt catalyst. The effect of THF on fuel cell performance is reversible. Diborane also can significant affect fuel cell performance. This effect is reversible once diborane is removed from the inlet streams. H2O2 is not an impurity usually present in the hydrogen or oxygen streams to a fuel cell. However, it is generated during fuel cell operation. The presence of Fe cations in the Nafion due to system corrosion and/or arising from MEA production act to catalyze the severe degradation of the Nafion by H2O2. Finally, the presence of metal cation impurities (Na+, Ca 2+, Fe3+) in Nafion from MEA preparation or from corrosion significantly impacts its proton conductivity due to replacement of proton sites. This effect is not reversible. Hydrocarbons, such as ethylene, might be expected to affect Pt or Nafion but do not at a typical fuel cell temperature of 80oC. In the presence of large quantities of hydrogen on the anode side, ethylene is converted to ethane which is very nonreactive. More surprisingly, even more reactive hydrocarbons such as formic acid and acetaldehyde do not appear to react enough with the strong Bronsted acid sites on Nafion at such low temperatures to affect Nafion conductivity properties. These results clearly identify a number of impurities which can have a detrimental impact on fuel cell performance, although some are reversible. Obviously, fuel cells exposed to impurities/poisons which are reversible can recover their original performance capabilities once the impurity flow is stopped. Impurities with irreversible effects should be either minimized in the feed streams, if possible, or new catalytic materials or ion conductors will need to be used to minimize their impact.

08 HYDROGEN↗

THE EFFECT OF THE PRESENCE OF OZONE ON THE LOWER FLAMMABILITY LIMIT OF HYDROGEN IN VESSELS CONTAINING SAVANNAH RIVER SITE HIGH LEVEL WASTE

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'.

08 HYDROGEN↗

Mapping ephemeral stream networks in desert environments using very-high-spatial-resolution multispectral remote sensing

In this paper, understanding the spatial patterns of ephemeral streams is crucial for understanding how hydrologic processes influence the abundance and distribution of wildlife habitats in desert regions. Available methods for mapping ephemeral streams at the watershed scale typically underestimate the size of channel networks. Although remote sensing is an effective means of collecting data and obtaining information on large, inaccessible areas, conventional techniques for extracting channel features are not sufficient in regions that have small topographic gradients and subtle target-background spectral contrast. By using very high resolution multispectral imagery, we developed a new algorithm that applies landscape information to map ephemeral channels in desert regions of the Southwestern United States where utility-scale solar energy development is occurring. Knowledge about landscape features and structures was integrated into the algorithm using a series of spectral transformation and spatial statistical operations to integrate information about landscape features and structures. The algorithm extracted ephemeral stream channels at a local scale, with the result that approximately 900% more ephemeral streams was identified than what were identified by using the U.S. Geological Survey’s National Hydrography Dataset. The accuracy of the algorithm in detecting channel areas was as high as 92%, and its accuracy in delineating channel center lines was 91% when compared to a subset of channel networks that were digitized by using the very high resolution imagery. Although the algorithm captured stream channels in desert landscapes across various channel sizes and forms, it often underestimated stream headwaters and channels obscured by bright soils and sparse vegetation. While further improvement is warranted, the algorithm provides an effective means of obtaining detailed information about ephemeral streams, and it could make a significant contribution toward improving the hydrological modelling of desert environments.

47 OTHER INSTRUMENTATION↗