Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion concentration polarization causes a nearly pore-length-independent conductance of nanopores

There has been a great amount of interest in nanopores as the basis for sensors and templates for preparation of biomimetic channels as well as model systems to understand transport properties at the nanoscale. The presence of surface charges on the pore walls has been shown to induce ion selectivity as well as enhance ionic conductance compared to uncharged pores. Here, using three-dimensional continuum modeling, we examine the role of the length of charged nanopores as well as applied voltage for controlling ion selectivity and ionic conductance of single nanopores and small nanopore arrays. First, we present conditions where the ion current and ion selectivity of nanopores with homogeneous surface charges remain unchanged, even if the pore length decreases by a factor of 6. This length-independent conductance is explained through the effect of ion concentration polarization (ICP), which modifies local ionic concentrations, not only at the pore entrances but also in the pore in a voltage-dependent manner. We describe how voltage controls the ion selectivity of nanopores with different lengths and present the conditions when charged nanopores conduct less current than uncharged pores of the same geometrical characteristics. The manuscript provides different measures of the extent of the depletion zone induced by ICP in single pores and nanopore arrays, including systems with ionic diodes. In conclusion, the modeling shown here will help design selective nanopores for a variety of applications where single nanopores and nanopore arrays are used.

Cain, DaVante↗

Electrothermoplasmonic Trapping and Dynamic Manipulation of Single Colloidal Nanodiamond

Low-power trapping of nanoscale objects can be achieved by using the enhanced fields near plasmonic nanoantennas. Unfortunately, in this approach the trap site is limited to the position of the plasmonic hotspots and continuous dynamic manipulation is not feasible. In this work, we report a low-frequency electrothermoplasmonic tweezer (LFET) that provides low-power, high-stability and continuous dynamic manipulation of a single nanodiamond. LFET harnesses the combined action of the laser illumination of a plasmonic nanopillar antenna array and low-frequency alternating current (ac) electric field to establish an electrohydrodynamic potential capable of the stable trapping and dynamic manipulation of single nanodiamonds. We experimentally demonstrate the fast transport, trapping, and dynamic manipulation of a single nanodiamond using a low-frequency ac field below 5 kHz and low-laser power of 1 mW. This nanotweezer platform for nanodiamond manipulation holds promise for the scalable assembly of single photon sources for quantum information processing and low noise quantum sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

Relating Hydro–Mechanical and Elastodynamic Properties of Dynamically Stressed Tensile–Fractured Rock in Relation to Applied Normal Stress, Fracture Aperture, and Contact Area

We exploit nonlinear elastodynamic properties of fractured rock to probe the micro-scale mechanics of fractures and understand the relation between fluid transport and fracture aperture under dynamic stressing. Experiments were conducted on rough, tensile-fractured Westerly granite subject to triaxial stresses. We measure fracture permeability for steady-state fluid flow with deionized water. Pore pressure oscillations are applied at amplitudes ranging from 0.2 to 1 MPa at 1 Hz frequency. During dynamic stressing we transmit ultrasonic signals through the fracture using an array of piezoelectric transducers (PZTs) to monitor evolution of interface properties. We examine the influence of fracture aperture and contact area by conducting measurements at effective normal stresses of 10–20 MPa. Additionally, the evolution of contact area with stress is characterized using pressure sensitive film. These experiments are conducted separately with the same fracture and map contact area at stresses from 9 to 21 MPa. The measurements are a proxy for “true” contact area for the fracture surface and we relate them to elastic properties using the calculated PZT sensor footprints via numerical modeling of Fresnel zones. We compare the elastodynamic response of the fracture using the stress-induced changes in ultrasonic wave velocities for transmitter-receiver pairs to image spatial variations in contact properties. We show that nonlinear elasticity and permeability enhancement decrease with increasing normal stress. Additionally, post-oscillation wave velocity and permeability exhibit quick recoveries toward pre-oscillation values. Estimates of fracture contact area (global and local) demonstrate that the elastodynamic and permeability responses are dominated by fracture topology.

58 GEOSCIENCES↗

PyDA: A Hands-On Introduction to Dynamical Data Assimilation with Python

Dynamic data assimilation offers a suite of algorithms that merge measurement data with numerical simulations to predict accurate state trajectories. Meteorological centers rely heavily on data assimilation to achieve trustworthy weather forecast. With the advance in measurement systems, as well as the reduction in sensor prices, data assimilation (DA) techniques are applicable to various fields, other than meteorology. However, beginners usually face hardships digesting the core ideas from the available sophisticated resources requiring a steep learning curve. In this tutorial, we lay out the mathematical principles behind DA with easy-to-follow Python module implementations so that this group of newcomers can quickly feel the essence of DA algorithms. We explore a series of common variational, and sequential techniques, and highlight major differences and potential extensions. We demonstrate the presented approaches using an array of fluid flow applications with varying levels of complexity.

97 MATHEMATICS AND COMPUTING↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory, and commercialization partner the Aquila Group.

Younkin, James↗

Compliant and stretchable thermoelectric coils for energy harvesting in miniature flexible devices

With accelerating trends in miniaturization of semiconductor devices, techniques for energy harvesting become increasingly important, especially in wearable technologies and sensors for the internet of things. Although thermoelectric systems have many attractive attributes in this context, maintaining large temperature differences across the device terminals and achieving low–thermal impedance interfaces to the surrounding environment become increasingly difficult to achieve as the characteristic dimensions decrease. Here, we propose and demonstrate an architectural solution to this problem, where thin-film active materials integrate into compliant, open three-dimensional (3D) forms. This approach not only enables efficient thermal impedance matching but also multiplies the heat flow through the harvester, thereby increasing the efficiencies for power conversion. Interconnected arrays of 3D thermoelectric coils built using microscale ribbons of monocrystalline silicon as the active material demonstrate these concepts. Quantitative measurements and simulations establish the basic operating principles and the key design features. The results suggest a scalable strategy for deploying hard thermoelectric thin-film materials in harvesters that can integrate effectively with soft materials systems, including those of the human body.

42 ENGINEERING↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards On-Chip Learning for Low Latency Reasoning with End-to-End Synthesis

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application-Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frame-works), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This paper provides an overview of the flow in the context of the generation of accelerators for edge processing to be integrated in transmission electron microscopy (TEM) devices, focusing on use cases from precision material synthesis. We show the tool in action with an example of design space exploration for inference on reconfigurable devices with a conventional deep neural network model (LeNet). Finally, we discuss the research directions and opportunities enabled by SODA in the area of autonomous control for scientific experimental workflows.

Castellana, Vito G.↗

Towards Automated Generation of Chiplet-Based Systems

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application- Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a high-level frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frameworks), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This talk will discuss ongoing work on the SODA synthesizer to enable no-human-in-the-loop generation and design space exploration of the chiplets for highly specialized artificial intelligence accelerators. Connecting these highly specialized chiplets to general-purpose cores or programmable accelerators will allow to quickly deploy autonomous systems for scientific discovery.

Limaye, Ankur M.↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.

array↗

Fundamental Piezotronic and Piezo-phototronic Effects in Nanowires

The piezo-phototronic effect is about the use of the piezoelectric potential created inside some materials for enhancing the charge carrier generation or separation at the metal-semiconductor contact or p-n junction. We demonstrate the impact of the piezo-phototronic effect on the photon sensitivity for a ZnO-CdS core-shell micro/nanowire based visible and UVsensor. CdS nanowire arrays were grown on the surface of a ZnO micro/nanowire to form a ZnO-CdS core-shell nanostructure by a facile hydrothermal method. With the two ends of a ZnO-CdS wire bonded on a polymer substrate, a flexible photodetector was fabricated, which is sensitive simultaneously to both green light (548 nm) and UV light (372 nm). The photocurrent and sensitivity of the ZnO_CdS wire photodetector is 103 times higher than that of CdS nanoribbon, and the responsivity (11 A W -1 , 548 nm, at 2 V bias) is nearly 100 times higher than that of ZnSe-nanobelt-based blue/UV-light sensor (0.12 AW -1 , 400 nm, at 30 V bias). Moreover, the performance of the ZnO-CdS wire photodetector upon illumination of visible and UV light can be both further enhanced for more than 10 times with the participation of the piezo-phototronic effect when the device is subjected to a -0.31% compressive strain. This investigation extends the application of the piezo-phototronic effect in a wide spectrum photon detector.

14 SOLAR ENERGY↗

Two–Photon Printing of Shape–Memory Microstructures and Metasurfaces via Radical–Mediated Thiol–Vinyl Hydrothiolation

Shape-memory resists capable of high-resolution curing into arbitrarily designed structures are increasingly demanded for soft robotics, optical sensors, microscale manufacturing, and biomedicine. Amorphous, shape-memory thiol-vinyl networks were printed using two-photon polymerization (2PP) curing of a simple resin formulated with commercially available reagents. The ability to print high-resolution feature sizes down to 200 nm is attributed to the use of radicalmediated, thiol-vinyl step-growth polymerization that quickly crosslinks the resin, limiting diffusive transport. The thermomechanical behavior of the 2PP-cured material analyzed in compression, tension and three-point bending is similar to the behavior of the UV-polymerized samples. To demonstrate the ability to design, field, and test 4D responsive microstructures, an array of nine springs with coil diameters of 330 μm was printed. Following compressive shapefixing, printed arrays can release 11 μJ of stored elastic strain energy when reheated. Further, a new concept of dichroic-memory of a metamaterial device is demonstrated by printing a twisted woodpile structure with circular dichroism as characterized by Mueller Matrix ellipsometry. Furthermore, our results demonstrate how combining high-resolution 2PP curing with stimuli-responsive molecular architectures can further the engineering of responsive microstructures and metamaterials.

36 MATERIALS SCIENCE↗

Future energy infrastructure, energy platform and energy storage

Today fossil energy dominates energy consumption across the world. There has been an increasing momentum to reduce fossil energy consumption and increase renewable energy utilization to more than 70%. Such high penetrations of distributed renewable resources bring large uncertainty and complexity that cannot be easily handled by the current infrastructure. For the last two decades, telecommunication industry has gone through a similar transition from centralized to distributed systems, and more recently to platform approaches, which become the corner stone of today’s vibrant platform economy. Based on telecommunication history, we believe that a platform-based approach, called the energy platform, is a viable solution for addressing the renewable energy challenges. The energy platform consists of an array of computational algorithms, sensing and control technologies for key industry, energy generators and users to jointly manage and control the complex energy infrastructure. It includes the following key components: (1) the hardware and software to generate, store, control and transmit electricity/data (the energy cloud), (2) the digital platforms and tools for key energy producers, digital, service and communication industry to share the assets, participate in and manage the complex infrastructure, and for customers to participate in energy transactions, (3) the transaction platform for new service and business models. Additionally, the energy platform requires breakthroughs in large scale energy storage and many other areas including efficient power electronics, sensors and controls, new mathematical and computational tools, and deep integration of energy technologies and information sciences to control and stabilize such complex chaotic systems.

25 ENERGY STORAGE↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sunlight collection system with lightguide having solid and fluid components

The system captures and concentrates sunlight for transmission to interior spaces or to a PV system. A solar collector uses arrayed refractive lenses and opposing concave focusing mirrors and a movable coupling sheet forming part of a lightguide. The transparent sheet contains small angled mirrors, where each angled mirror corresponds to a particular set of the lenses/focusing mirrors and is in the focal plane. The lightguide also includes a fluid surrounding the transparent sheet, and lower index cladding layers sandwich the fluid. The sheet is translated within the fluid by an actuator to position the angled mirrors at the focal points of the sunlight for maximum deflection of the sunlight to an edge of the lightguide for extraction to a light transmission system or to a PV system. A position sensor on the sheet provides feedback regarding the position of the angled mirrors relative to the focal points.

Kozodoy, Peter↗