Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Spectral Gradients and u-v Sampling

I describe a systematic method for characterizing the effects of differences in u-v coverage in terms of inferred spectral gradients in interferometric images. This method is directly applicable to optical and radio interferometry; it is useful in situations when observations using scale arrays are not feasible.

u-v sampling spectral gradients interferometric im↗

Two techniques enable sampling of filtered and unfiltered molten metals

Filtered samples of molten metals are obtained by filtering through a plug of porous material fitted in the end of a sample tube, and unfiltered samples are obtained by using a capillary-tube extension rod with a perforated bucket. With these methods there are no sampling errors or loss of liquid.

Burris, L., Jr.↗

Real-Time Adaptive Drag Minimization Wind Tunnel Investigation of a Flexible Wing with Variable Camber Continuous Trailing Edge Flap System

This paper reports the results of a recently completed real-time adaptive drag minimization wind tunnel investigation of a highly flexible wing wind tunnel model equipped with the Variable Camber Continuous Trailing Flap (VCCTEF) technology at the University of Washington Aeronautical Laboratory (UWAL). The wind tunnel investigation is funded by NASA SBIR Phase II contract with Scientific Systems Company, Inc. (SSCI) and University of Washington (UW) as a subcontractor. The wind tunnel model is a sub-scale Common Research Model (CRM) wing constructed of foam core and fiberglass skin and is aeroelastically scaled to achieve a wing tip deflection of 10% of the wing semi-span which represents a typical wing tip deflection for a modern transport such as Boeing 787. The jig-shape twist of the CRM wing is optimized using a CART3D aero-structural model to achieve the minimum induced drag for the design cruise lift coefficient of 0.5. The wing is equipped with two chord wise cambered segments for each of the six span wise flap sections for a total of 12 individual flap segments that comprise the VCCTEF system. Each of the 12 flap segments is actively controlled by an electric servo-actuator. The real-time adaptive drag optimization strategy includes an on-board aerodynamic model identification, a model excitation, and a real-time drag optimization. The on-board aerodynamic model is constructed parametrically as a function of the angle of attack and flap positions to model the lift and drag coefficients of the wing. The lift coefficient models include a linear model and a second-order model. The drag coefficient models include a quadratic model and a higher-order up to 6th-order model to accurately model the drag coefficient at high angles of attack. The onboard aerodynamic model identification includes a recursive least-squares (RLS) algorithm and a batch least-squares (BLS) algorithm designed to estimate the model parameters. The model excitation method is designed to sample the input set that comprises the angle of attack and the flap positions. Three model excitation methods are developed: random excitation method, sweep method, and iterative angle-of-attack seeking method. The real-time drag optimization includes a generic algorithm developed by SSCI and several optimization methods developed by NASA which include a second-order gradient Newton-Raphson optimization method, an iterative gradient optimization method, a pseudo-inverse optimization method, an analytical optimization method, and an iterative refinement optimization method. The first wind tunnel test entry took place in September 2017. This test revealed major hardware issues and required further redesign of the flap servo mechanisms. The second test entry took place in April 2018. However, the test was not successful due to the issues with the onboard aerodynamic model identification RLS algorithm which incorrectly identified model parameters. This test also provides an experimental comparison study between the VCCTEF and a variable camber discrete trailing edge flap (VCDTEF) without the elastomer transition mechanisms. The experimental result confirms the benefit of the VCCTEF which produces lower drag by 5% than the VCDTEF. The third and final test entry took place in June 2018 after the issues with the RLS algorithm have been identified and corrected. Additional improvements were implemented. These include the BLS algorithm, the iterative angle-of-attack seeking method, the iterative gradient optimization method, and the pseudo-inverse optimization method. The test objectives were successfully demonstrated as the real-time drag optimization identifies several optimal solutions at off-design lift coefficients. The iterative gradient optimization method is found to achieve up to 4.7% drag reduction for the off-design lift coefficient of 0.7. The pseudo-inverse optimization method which does not require the drag coefficient model is found to be quite effective in reducing drag. Up to 9.4% drag reduction for the off-design lift coefficient of 0.7 is achieved with the pseudo-inverse optimization method. The wind tunnel investigation demonstrates the potential of real-time drag optimization technology. Several new capabilities are developed that could enable future adaptive wing technologies for flexible wings equipped with drag control devices such as the VCCTEF.

Drag Optimization↗

Soil Sampling Techniques For Alabama Grain Fields

Characterizing the spatial variability of nutrients facilitates precision soil sampling. Questions exist regarding the best technique for directed soil sampling based on a priori knowledge of soil and crop patterns. The objective of this study was to evaluate zone delineation techniques for Alabama grain fields to determine which method best minimized the soil test variability. Site one (25.8 ha) and site three (20.0 ha) were located in the Tennessee Valley region, and site two (24.2 ha) was located in the Coastal Plain region of Alabama. Tennessee Valley soils ranged from well drained Rhodic and Typic Paleudults to somewhat poorly drained Aquic Paleudults and Fluventic Dystrudepts. Coastal Plain s o i l s ranged from coarse-loamy Rhodic Kandiudults to loamy Arenic Kandiudults. Soils were sampled by grid soil sampling methods (grid sizes of 0.40 ha and 1 ha) consisting of: 1) twenty composited cores collected randomly throughout each grid (grid-cell sampling) and, 2) six composited cores collected randomly from a -3x3 m area at the center of each grid (grid-point sampling). Zones were established from 1) an Order 1 Soil Survey, 2) corn (Zea mays L.) yield maps, and 3) airborne remote sensing images. All soil properties were moderately to strongly spatially dependent as per semivariogram analyses. Differences in grid-point and grid-cell soil test values suggested grid-point sampling does not accurately represent grid values. Zones created by soil survey, yield data, and remote sensing images displayed lower coefficient of variations (8CV) for soil test values than overall field values, suggesting these techniques group soil test variability. However, few differences were observed between the three zone delineation techniques. Results suggest directed sampling using zone delineation techniques outlined in this paper would result in more efficient soil sampling for these Alabama grain fields.

Thompson, A. N.↗

Aircraft digital control design methods

Variations in design methods for aircraft digital flight control are evaluated and compared. The methods fall into two categories; those where the design is done in the continuous domain (or s plane) and those where the design is done in the discrete domain (or z plane). Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the uncompensated s plane design method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

Relative toxicity of pyrolysis products of some elastomers

Ten samples comprising seven generic types of elastomers were evaluated for relative toxicity using the USF/NASA toxicity screening test method. The nitrile rubber samples appeared to generally exhibit greater toxicity than the samples of polyisoprene, styrene butadiene, and chlorinated polyethylene rubber. Carbon monoxide was present in sufficient concentration in the blood of the test animals to be the principal cause of death in the case of polyisoprene and styrene butadiene rubber.

Hilado, C. J.↗

Enhanced Cleaning of Genesis Solar Wind Sample 61348 for Film Residue Removal

The Genesis mission returned to Earth on September 8, 2004, experiencing a nonnominal reentry. During the recovery of the collector materials from the capsule, many of the collector fragments were placed on the adhesive protion of post-it notes to prevent the fragments from moving during transport back to Johnson Space Center. This unknowingly provided an additional contaminate that would prove difficult to remove with the limited chemistries allowed in the Genesis Curation Laboratory. Generally when collector material samples are prepared for allocation to PIs, the samples are cleaned front side only with Ultra-Pure Water (UPW) via megasonic dispersion to the collector surface to remove crash debris and contamination. While this cleaning method works well on samples that were not placed on post-its during recovery, it has caused movement of the residue on the back of the sample to be deposited on the front in at least two examples. Therefore, samples placed on the adhesive portion on post-it note, require enhanced cleaning methods since post-it residue has proved resistant to UPW cleaning.

Allums, K. K.↗

A thermal conductivity cell for small powdered samples.

A thermal conductivity cell is described for making measurements of the thermal conductivity and thermal diffusivity of small samples of powdered dielectric materials. The principle used is that of the line heat source. A novel way is described for applying this method so that much smaller samples than normal may be tested. This size requirement is necessary for investigations involving limited samples as does the Lunar Science Program. The method is checked by measuring the conductivity of standard samples and comparing the results with those found in the literature.

Cremers, C. J.↗

A comparison of digital flight control design methods

Many variations in design methods for aircraft digital flight control have been proposed in the literature. In general, the methods fall into two categories: those where the design is done in the continuous domain (or s-plane), and those where the design is done in the discrete domain (or z-plane). This paper evaluates several variations of each category and compares them for various flight control modes of the Langley TCV Boeing 737 aircraft. Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the 'uncompensated s-plane design' method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

Magnetic constraints on early lunar evolution revisited: Limits on accuracy imposed by methods of paleointensity measurements

It is impossible to carry out conventional paleointensity experiments requiring repeated heating and cooling to 770 C without chemical, physical or microstructural changes on lunar samples. Non-thermal methods of paleointensity determination have been sought: the two anhysteretic remanent magnetization (ARM) methods, and the saturation isothermal remanent magnetization (IRMS) method. Experimental errors inherent in these alternative approaches have been investigated to estimate the accuracy limits on the calculated paleointensities. Results are indicated in this report.

Banerjee, S. K.↗

Preshaping command inputs to reduce telerobotic system oscillations

The results of using a new technique for shaping inputs to a model of the space shuttle Remote Manipulator System (RMS) are presented. The shapes inputs move the system to the same location that was originally commanded, however, the oscillations of the machine are considerably reduced. An overview of the new shaping method is presented. A description of RMS model is provided. The problem of slow joint servo rates on the RMS is accommodated with an extension of the shaping method. The results and sample data are also presented for both joint and three-dimensional cartesian motions. The results demonstrate that the new shaping method performs well on large, telerobotic systems which exhibit significant structural vibration. The new method is shown to also result in considerable energy savings during operations of the RMS manipulator.

Singer, Neil C.↗

Novel High Barrier Films for Packaging Food and Medicine

Long manned missions require food packaging to maintain food safety, nutrition, and acceptability for the length of 3-5 years1,2 while the shelf life assigned by NASA for current provisions is 18-24 months1. The focus of this design project was to make a polymer film specifically to function as a high oxygen barrier to later be included in an improved multi-layer packaging system of other specialized polymers with capabilities to allow for a 5-year shelf-life. To qualify as a high oxygen barrier film and to be a successful design for the future packaging, the resulting film is required to have an oxygen transmission rate (OTR) less than 0.06 cc/ m2/24 hr/atm, the standard for the current packaging3. This new film was designed to have a decreased permeability by increasing the “tortuous path” a gas molecule travels to permeate through a film. The increase in the “tortuous path” of a gas molecule is accomplished by introducing a 2D material additive. The additive chosen for this project was hexagonal boron nitride (h-BN) which exfoliates into boron nitride nanosheets (BNNs). Nylon 6 was chosen as the candidate for the matrix. This project is required to determine the best methods to synthesize the sample film and then to test the OTR of the film to determine if this design was successful. This project examined methods for pulverizing polymer resin pellets, h-BN exfoliation, and film fabrication using a hot press. This report includes the exfoliation and analysis of h-BN, procedural preparations for films, and a modeling study of estimated OTR of the h-BN/Nylon. The work in this report did not yield a high barrier composite film because of the laboratory closure in response to COVID -19 guidance but provides a concise method of the additive preparation and film synthesis. This gives a good starting point for future research in high barrier films by 2D additive composites.

Polymer, Nylon, PET, boron nitride, nanocomposite↗

Culture-Independent Fungal Profiling for the International Space Station using Nanopore Sequencing: Method Development

Microbial monitoring of the International Space Station (ISS) environment is a crew health requirement that encompasses both bacterial and fungal identification. To achieve this currently, culture-based methods are used for sample collection, and these samples must be returned to the laboratory for analysis. The use of culture and the need for sample return to Earth results in a bias toward culturable organisms and causes a significant delay between sample collection and delivery of final data (weeks to months), respectively. Recently, advancements in molecular technology have aided a broad range of applications, including medical, industrial, and basic sciences. Additionally, increases in portability and ease-of-use of molecular platforms have provided point-of-use capabilities demonstrated by the miniPCR thermal cycler (miniPCR bio) and the MinION sequencer (Oxford Nanopore Technologies). Together, these devices have been applied to, and validated for, the identification of bacteria onboard the ISS. Building on this work, we have developed a spaceflight-compatible fungal workflow. Molecular-based fungal analysis is complicated by low biomass, difficult-to-lyse spores, debate regarding the region for taxonomic assignment, and the lack of bioinformatic pipelines and reference databases. To overcome these difficulties, primers yielding an ~ 2 Kb amplicon were validated against a wide range of ISS fungal isolates. The current spaceflight library preparation was substantially optimized, a bioinformatic pipeline was created, and refinements to the UNITE database were implemented. To compare this optimized method to the current culture-based standard, 30 sample sets (60 total swabs, two swabs held in tandem) were evaluated. Parallel fungal profiles were obtained between the two methods, with the culture-independent method revealing increased diversity. The addition of this method to the already established bacterial process fulfills the crew health identification requirement. Moreover, the implementation of this method onboard ISS will enhance our understanding of its unique fungal microbiome.

Hang N. Nguyen↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Experimental breakdown of selected anodized aluminum samples in dilute plasmas

Anodized aluminum samples representative of Space Station Freedom structural material were tested for electrical breakdown under space plasma conditions. In space, this potential arises across the insulating anodized coating when the spacecraft structure is driven to a negative bias relative to the external plasma potential due to plasma-surface interaction phenomena. For anodized materials used in the tests, it was found that breakdown voltage varied from 100 to 2000 volts depending on the sample. The current in the arcs depended on the sample, the capacitor, and the voltage. The level of the arc currents varied from 60 to 1000 amperes. The plasma number density varied from 3 x 10 exp 6 to 10 exp 3 ions per cc. The time between arcs increased as the number density was lowered. Corona testing of anodized samples revealed that samples with higher corona inception voltage had higher arcing inception voltages. From this it is concluded that corona testing may provide a method of screening the samples.

Grier, Norman T.↗

Use of a laser for the spectral analysis of semiconductor materials

Conventional applications of lasers for emission spectroscopy involving direct recording of light pulses of an evaporated substance emitted from the sample under the action of the laser light (direct method) were examined. Use of the laser light for conversion of the substance to a vapor and feeding the vapors into the conventional source of emission such as arc, sparks, etc. (the so called 2 stage excitation) were studied for use in the spectral analysis, of semiconductors. The direct method has a high reproducibility (5-7%); the 2 stage excitation method, characterized by the same intensity as obtained with the conventional constant, current arc, has better reproducibility than the direct method (15-20%). Both methods can be used for the analysis of samples without prior preparation. Advantages of these methods are the elimination of impurities picked up during trituration of the samples into powders and shortening of the analytical procedures.

Karyakin, A. V.↗

Verification of vegetation maps made from remote sensing

Verification of vegetation maps is discussed, including a map of the vegetation of the Mt. Washington area of New Hampshire. This area was chosen to determine the accuracy of mapping by remote sensing at the boundary between two major forest biomass. Verification was carried out by ground observation and through the use of low altitude 70 mm infrared photographs. Two verification sampling schemes were used: a point method and a transect method. Resulting confidence limits gave an area weighted sampling accuracy of 89 pct. Spatial patterns in terrestrial vegetation must be understood in order to choose appropriate spatial resolutions required for remote sensing instruments, and to relate vegetation dynamics to climate dynamics and biogeochemical cycles.

Botkin, Daniel B.↗