BESSIE: Battery & Energy Storage Supply Chain Analysis, Mitigation Deployment, and Tools

Battery energy storage systems (BESS) and their associated power electronic interfaces are key components to delivering clean and more resilient energy, providing much-needed fast-ramping, emergency discharge, generation, and operations support to the electric grid. These services have grown to be invaluable over the past ten years and will soon be an irreplaceable element of energy delivery. The Idaho National Laboratory (INL) strives to address these challenges through a strategic approach to supply chain risk assessment and mitigation for BESS and related digital energy equipment through the BESSIE project under the Center for Securing Digital Energy Technology. Recognizing that decreasing dependence on a foreign supply chain will take significant time and investment, BESSIE’s focus is strategically addressing battery supply chain risks by pairing short-term steps to operate securely through today’s risks with long-term steps to shape the supply chain over the coming years.

25 ENERGY STORAGE↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid Imitation Learning for Real-Time Service Restoration in Resilient Distribution Systems

Self-healing capability is a critical factor for a resilient distribution system, which requires intelligent agents to automatically perform service restoration online, including network reconfiguration and reactive power dispatch. Here, the article proposes the imitation learning framework for training such an agent, where the agent will interact with an expert built based on the mixed-integer program to learn its optimal policy, and therefore significantly improve the training efficiency compared with exploration-dominant reinforcement learning (RL) methods. This significantly improved training efficiency makes the training problem under N-k scenarios tractable. A hybrid policy network is proposed to handle tie-line operations and reactive power dispatch simultaneously to further improve the restoration performance. The 33-bus and 119-bus systems with N-k disturbances are employed to conduct the training. The results indicate that the proposed method outperforms traditional RL algorithms such as the deep-Q network.

42 ENGINEERING↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Hydrogen Transportation and Distributed Energy Systems Risk Assessment for Airport Facilities (CRADA 555) (Final Report)

Portland International Airport (PDX), Oregon, operated by the Port of Portland (Port) is exploring the possibility of operating a fleet of 28 fuel cell electric buses and developing a distributed energy system to support airport operations during various operating modes including large-scale power outages. This study investigates the compatibility of these two missions, which will be key to resilience management at PDX. This study also investigated the risks associated with deploying a hydrogen system that could support bus operations and be utilized during an emergency to ensure continued operation of the airport. This will be a key innovation for the deployment of hydrogen systems at airports. Utilizing the unique benefits of hydrogen infrastructure for multiple roles will aid adopters in justifying new projects and serve to demonstrate the versatility of hydrogen as an energy-carrier to a wider market.

08 HYDROGEN↗

Integrating Cybersecurity with System Operations and Restoration

This presentation covers the interaction of the discipline of system operations with the discipline of cybersecurity. First, a common mental model for risk - both cybersecurity and all-hazards - is presented, followed by a discussion of high-level management strategies for different kinds of cyber harm facing system operators, based on the consequences and frequencies of the harm. The next section covers the importance of cybersecurity for a system operator organization and explains some general concepts to understand the relationships. Finally the role of system operators in the security of the grid as a larger system of systems is discussed over the framework of a resilience event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-Disaster Microgrid Formation for Enhanced Distribution System Resilience

This paper proposes a deep reinforcement learning (DRL) based approach for post-disaster critical load restoration in active distribution systems to form microgrids through network reconfiguration to minimize critical load curtailments. Distribution networks are represented as graph networks, and optimal network configurations with microgrids are obtained by searching for the optimal spanning forest. The constraints to the research question being explored are the radial topology and power balance. Unlike existing analytical and population-based approaches, which necessitate the repetition of entire analyses and computation for each outage scenario to find the optimal spanning forest, the proposed approach, once properly trained, can quickly determine the optimal, or near-optimal, spanning forest even when outage scenarios change. When multiple lines fail in the system, the proposed approach forms microgrids with distributed energy resources in active distribution systems to reduce critical load curtailment. The proposed DRL-based model learns the action-value function using the REINFORCE algorithm, which is a model-free reinforcement learning technique based on stochastic policy gradients. A case study was conducted on a 33-node distribution test system, demonstrating the effectiveness of the proposed approach for post-disaster critical load restoration.

active distribution systems↗

Resilient Communication Scheme for Distributed Decision of Interconnecting Networks of Microgrids

Networking of microgrids can provide the operational flexibility needed for the increasing number of DERs deployed at the distribution level and supporting end-use demand when there is loss of the bulk power system. But, networked microgrids are vulnerable to cyber-physical attacks and faults due to the complex interconnections. As such, it is necessary To design resilient control systems to support the operations of networked microgrids in responses to cyber-physical attacks and faults. This paper introduces a resilient communication scheme for interconnecting multiple microgrids to support critical demand, in which the interconnection decision can be made distributedly by each microgrid controller even in the presence of cyberattacks to some communication links or microgrid controllers. This scheme blends a randomized peer-to-peer communication network for exchanging information among controllers and resilient consensus algorithms for achieving reliable interconnection agreement. The network of 6 microgrids divided from a modified 123-node test distribution feeder is used to demonstrate the effectiveness of the proposed resilient communication scheme.

Vu, Thanh Long↗

Can an Efficient Nuclear Energy Industry Still be Resilient? On the Nature of Efficiency and Resiliency in Complex Systems

At the time of writing, the nuclear industry is on the precipice of a long-hoped for, but as-yet-unrealized, “nuclear renaissance.” Nuclear power plants in the United States and around the globe are aging, emphasizing the criticality of this moment. The importance of carbon free power sources combined with advancements in nuclear technology and innovation have brought a new potential landscape. As existing reactors and utilities cope with increased economic pressure by seeking out efficiencies the push towards novel nuclear platforms like microreactors and fission batteries will only increase this quest for efficiency gains, potentially at the detriment of safety. This paper argues that the concepts of efficiency and resiliency are fundamentally linked and that the change in one necessarily affects the other. As nuclear power is known for being incredibly resilient, this dichotomy needs attention from the current wave of research towards nuclear power efficiencies. This paper argues for resiliency at any cost. We argue that this resilience-first approach is the right path for nuclear power to take in this net-zero future. The paper is laid out as follows. Section 1 introduces the economic context and resilient nature of nuclear power. Section 2 discusses efficiency, resiliency, and the struggle between the two in nuclear power. Section 3 exemplifies our argument through case studies in the aviation and manufacturing industries and extends the argument to the nuclear industry. Section 4 concludes with a discussion of the implications of this idea.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Primary Frequency Control Using Motor Drives for Short Term Grid Disturbances

Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identifying Suitable Front Contacts for High‐Efficiency Cd(Se,Te) Solar Cells on Space‐Qualified Cover Glass

Deployment of photovoltaics in space requires devices that combine high-efficiency, low areal mass, and resilience to harsh environments. Historically, high-efficiency multijunction III–V materials have dominated space power systems; however, their high cost and limited manufacturing throughput motivate the exploration of scalable alternatives. While CdTe-based thin-film photovoltaics offer an attractive option, their performance on non-conventional substrates can suffer from front contact instability under higher-temperature processing. Here, the role of front contact chemistry in limiting cell performance is investigated using CdTe-based devices fabricated on 150 μm thick Ceria-doped space-qualified 0214 Corning glass. A matrix of four transparent conducting oxides (TCOs: CTO, AZO, ITO, IZO) combined with two n-type emitters (MZO, IGO) reveals chemical stability at the front interface—rather than absorber composition alone—governs recombination losses, voltage deficits, and device reproducibility. Chemically stable front contact combinations suppress elemental diffusion and interfacial degradation, resulting in significantly improved carrier lifetimes and junction quality. These insights are validated through record-certified Cd(Se,Te) cell efficiencies of 18.4% under AM1.5G and 16.2% under AM0 illumination on ultra-thin glass. Beyond CdTe, this work provides a general framework for the rational selection of TCO/emitter interfaces in superstrate thin-film photovoltaics, including emerging technologies like metal halide perovskites, while enabling high-efficiency, lightweight photovoltaics for space applications.

14 SOLAR ENERGY↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗

Data Associated with "Identifying Suitable Front Contacts for High-Efficiency Cd(Se,Te) Solar Cells on Space-Qualified Cover Glass"

This is data associated with the publication " Identifying Suitable Front Contacts for High-Efficiency Cd(Se,Te) Solar Cells on Space-Qualified Cover Glass " by Aesha P. Patel, Ryan Muzzio, Matthew R. Young, Robert Morrissey, Suresh Chaulagain, B. Edward Sartor, Prabodika N. Kaluarachchi, Christian Velez, Joshua A. Brown, Joel N. Duenow, Stephen Glynn, Michael J. Heben, Zhaoning Song, Nikolas J. Podraza, Adam B. Phillips, Randy J. Ellingson, Matthew O. Reese. All data associated with each figure in the manuscript and supplementary should be available in this dataset. A readme file is also included to provide some guidance. Abstract: Deployment of photovoltaics in space requires devices that combine high-efficiency, low areal mass, and resilience to harsh environments. Historically, high-efficiency multijunction III–V materials have dominated space power systems; however, their high cost and limited manufacturing throughput motivate the exploration of scalable alternatives. While CdTe-based thin-film photovoltaics offer an attractive option, their performance on non-conventional substrates can suffer from front-contact instability under higher-temperature processing. Here, the role of front-contact chemistry in limiting cell performance is investigated using CdTe-based devices fabricated on 150 μm thick Ceria-doped space-qualified 0214 Corning glass. A matrix of four transparent conducting oxides (TCOs: CTO, AZO, ITO, IZO) combined with two n-type emitters (MZO, IGO) reveals chemical stability at the front interface—rather than absorber composition alone—governs recombination losses, voltage deficits, and device reproducibility. Chemically stable front-contact combinations suppress elemental diffusion and interfacial degradation, resulting in significantly improved carrier lifetimes and junction quality. These insights are validated through record-certified Cd(Se,Te) cell efficiencies of 18.4% under AM1.5G and 16.2% under AM0 illumination on ultra-thin glass. Beyond CdTe, this work provides a general framework for the rational selection of TCO/emitter interfaces in superstrate thin-film photovoltaics, including emerging technologies like metal halide perovskites, while enabling high-efficiency, lightweight photovoltaics for space applications.

14 SOLAR ENERGY↗