Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Pipelined digital SAR azimuth correlator using hybrid FFT-transversal filter

A synthetic aperture radar system (SAR) having a range correlator is provided with a hybrid azimuth correlator which utilizes a block-pipe-lined fast Fourier transform (FFT). The correlator has a predetermined FFT transform size with delay elements for delaying SAR range correlated data so as to embed in the Fourier transform operation a corner-turning function as the range correlated SAR data is converted from the time domain to a frequency domain. The azimuth correlator is comprised of a transversal filter to receive the SAR data in the frequency domain, a generator for range migration compensation and azimuth reference functions, and an azimuth reference multiplier for correlation of the SAR data. Following the transversal filter is a block-pipelined inverse FFT used to restore azimuth correlated data in the frequency domain to the time domain for imaging.

Wu, C.↗

The use of multiwavelets for uncertainty estimation in seismic surface wave dispersion.

This report describes a new single-station analysis method to estimate the dispersion and uncer- tainty of seismic surface waves using the multiwavelet transform. Typically, when estimating the dispersion of a surface wave using only a single seismic station, the seismogram is decomposed into a series of narrow-band realizations using a bank of narrow-band filters. By then enveloping and normalizing the filtered seismograms and identifying the maximum power as a function of frequency, the group velocity can be estimated if the source-receiver distance is known. However, using the filter bank method, there is no robust way to estimate uncertainty. In this report, I in- troduce a new method of estimating the group velocity that includes an estimate of uncertainty. The method is similar to the conventional filter bank method, but uses a class of functions, called Slepian wavelets, to compute a series of wavelet transforms of the data. Each wavelet transform is mathematically similar to a filter bank, however, the time-frequency tradeoff is optimized. By taking multiple wavelet transforms, I form a population of dispersion estimates from which stan- dard statistical methods can be used to estimate uncertainty. I demonstrate the utility of this new method by applying it to synthetic data as well as ambient-noise surface-wave cross-correlelograms recorded by the University of Nevada Seismic Network.

58 GEOSCIENCES↗

A structural model of anti-anti-[sigma] inhibition by a two-component receiver domain: the PhyR stress response regulator

PhyR is a hybrid stress regulator conserved in {alpha}-proteobacteria that contains an N-terminal {sigma}-like (SL) domain and a C-terminal receiver domain. Phosphorylation of the receiver domain is known to promote binding of the SL domain to an anti-{sigma} factor. PhyR thus functions as an anti-anti-{sigma} factor in its phosphorylated state. We present genetic evidence that Caulobacter crescentus PhyR is a phosphorylation-dependent stress regulator that functions in the same pathway as {sigma}{sup T} and its anti-{sigma} factor, NepR. Additionally, we report the X-ray crystal structure of PhyR at 1.25 {angstrom} resolution, which provides insight into the mechanism of anti-anti-{sigma} regulation. Direct intramolecular contact between the PhyR receiver and SL domains spans regions {sigma}{sub 2} and {sigma}{sub 4}, likely serving to stabilize the SL domain in a closed conformation. The molecular surface of the receiver domain contacting the SL domain is the structural equivalent of {alpha}4-{beta}5-{alpha}5, which is known to undergo dynamic conformational change upon phosphorylation in a diverse range of receiver proteins. We propose a structural model of PhyR regulation in which receiver phosphorylation destabilizes the intramolecular interaction between SL and receiver domains, thereby permitting regions {sigma}{sub 2} and {sigma}{sub 4} in the SL domain to open about a flexible connector loop and bind anti-{sigma} factor.

59 BASIC BIOLOGICAL SCIENCES↗

Organic–Inorganic Perovskites: Structural Versatility for Functional Materials Design

Although known since the late 19th century, organic–inorganic perovskites have recently received extraordinary research community attention because of their unique physical properties, which make them promising candidates for application in photovoltaic (PV) and related optoelectronic devices. In this review, we will explore beyond the current focus on three-dimensional (3-D) lead(II) halide perovskites, to highlight the great chemical flexibility and outstanding potential of the broader class of 3-D and lower dimensional organic-based perovskite family for electronic, optical, and energy-based applications as well as fundamental research. The concept of a multifunctional organic–inorganic hybrid, in which the organic and inorganic structural components provide intentional, unique, and hopefully synergistic features to the compound, represents an important contemporary target.

36 MATERIALS SCIENCE↗

Entanglement-assisted zero-error capacity is upper-bounded by the Lovasz {theta} function

The zero-error capacity of a classical channel is expressed in terms of the independence number of some graph and its tensor powers. This quantity is hard to compute even for small graphs such as the cycle of length seven, so upper bounds such as the Lovasz theta function play an important role in zero-error communication. In this paper, we show that the Lovasz theta function is an upper bound on the zero-error capacity even in the presence of entanglement between the sender and receiver.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated Sustainable Product Design With Warranty and End-of-Use Considerations

The concept of integrated sustainable product design has recently emerged, aiming to incorporate downstream life cycle performance into the initial product design to enhance sustainability. Various sustainable product design tools based on life cycle assessment or quality function deployment have been established while the impact of reliability on circular practices has received limited attention. Recognizing the critical role of product reliability in post-design performance, this paper develops a product design optimization model that considers the warranty performance and the effect of end-of-use options. The model takes into account the effect of uncertain operating conditions on product reliability. Two optimization goals including the minimization of expected unit life cycle cost and environmental impact are achieved by the model. To demonstrate the benefits of the integrated approach, the model is applied to an electric motor design problem. The results highlight that integrating end-of-use options in the early design phase leads to adjustments in component selection and reliability design. Moreover, the circular utilization of used products enables cost savings throughout the product’s life cycle and contributes to environmental impact reduction. Finally, the study analyzes the effects of operating conditions, warranty policies, and take-back prices for used products on design decisions, providing valuable insights for product designers.

Integrated design↗

Vulval and Vaginal Rhabdomyosarcoma in Children: Update and Reappraisal of Institut Gustave Roussy Brachytherapy Experience

Purpose: To report the Institut Gustave Roussy brachytherapy (BT) experience in the management of vulval and vaginal rhabdomyosarcoma with special emphasis on long-term outcome. Patients and Methods: Between 1971 and 2005, the data concerning 39 girls who had undergone BT as a part of their treatment were retrospectively analyzed. Of the 39 girls, 20 had been treated before 1990, when the BT volume encompassed the initial tumor extension. After 1990, only residual disease was included in the BT volume. Side effects were classified using the Common Terminology Criteria for Adverse Events, version 3.0. Results: The median age was 16.3 months at diagnosis. Vaginal or vulvar rhabdomyosarcoma was diagnosed in 26 and 6 patients, respectively. The median follow-up was 8.4 years. The 5-year overall survival rate was 91%. Of the 39 patients, 6 developed a relapse. Of the 20 patients treated before 1990, 6 experienced Grade 1-2 renal/genitourinary function symptoms and 75% developed sequelae, in the form of vaginal or urethral sclerosis or stenosis. Four patients received follow-up treatment for psychological disorders. Of the 19 patients treated after 1990, 2 developed acute side effects, with maximal Grade 1-2 renal/genitourinary function symptoms, and 20% developed vaginal or urethral sclerosis or stenosis. Two cases of psychological disturbances were also documented. Conclusion: Reducing the BT volume coverage, better indications for surgery, and more efficient chemotherapy, all combined within a multidisciplinary approach, tended to improve results in terms of both survival and long-term sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Creation of a CPU Timer for High Fidelity Programs

Using C and C++ programming languages, a tool was developed that measures the efficiency of a program by recording the amount of CPU time that various functions consume. By inserting the tool between lines of code in the program, one can receive a detailed report of the absolute and relative time consumption associated with each section. After adapting the generic tool for a high-fidelity launch vehicle simulation program called MAVERIC, the components of a frequently used function called "derivatives ( )" were measured. Out of the 34 sub-functions in "derivatives ( )", it was found that the top 8 sub-functions made up 83.1% of the total time spent. In order to decrease the overall run time of MAVERIC, a launch vehicle simulation program, a change was implemented in the sub-function "Event_Controller ( )". Reformatting "Event_Controller ( )" led to a 36.9% decrease in the total CPU time spent by that sub-function, and a 3.2% decrease in the total CPU time spent by the overarching function "derivatives ( )".

Dick, Aidan A.↗

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hemithoracic Intensity Modulated Radiation Therapy After Pleurectomy/Decortication for Malignant Pleural Mesothelioma: Toxicity, Patterns of Failure, and a Matched Survival Analysis

Purpose: To investigate safety, efficacy, and recurrence after hemithoracic intensity modulated radiation therapy after pleurectomy/decortication (PD-IMRT) and after extrapleural pneumonectomy (EPP-IMRT). Methods and Materials: In 2009-2013, 24 patients with mesothelioma underwent PD-IMRT to the involved hemithorax to a dose of 45 Gy, with an optional integrated boost; 22 also received chemotherapy. Toxicity was scored with the Common Terminology Criteria for Adverse Events v4.0. Pulmonary function was compared at baseline, after surgery, and after IMRT. Kaplan-Meier analysis was used to calculate overall survival (OS), progression-free survival (PFS), time to locoregional failure, and time to distant metastasis. Failures were in-field, marginal, or out of field. Outcomes were compared with those of 24 patients, matched for age, nodal status, performance status, and chemotherapy, who had received EPP-IMRT. Results: Median follow-up time was 12.2 months. Grade 3 toxicity rates were 8% skin and 8% pulmonary. Pulmonary function declined from baseline to after surgery (by 21% for forced vital capacity, 16% for forced expiratory volume in 1 second, and 19% for lung diffusion of carbon monoxide [P for all = .01]) and declined still further after IMRT (by 31% for forced vital capacity [P=.02], 25% for forced expiratory volume in 1 second [P=.01], and 30% for lung diffusion of carbon monoxide [P=.01]). The OS and PFS rates were 76% and 67%, respectively, at 1 year and 56% and 34% at 2 years. Median OS (28.4 vs 14.2 months, P=.04) and median PFS (16.4 vs 8.2 months, P=.01) favored PD-IMRT versus EPP-IMRT. No differences were found in grade 4-5 toxicity (0 of 24 vs 3 of 24, P=.23), median time to locoregional failure (18.7 months vs not reached, P not calculable), or median time to distant metastasis (18.8 vs 11.8 months, P=.12). Conclusions: Hemithoracic intensity modulated radiation therapy after pleurectomy/decortication produced little high-grade toxicity but led to progressive declines in pulmonary function; OS and PFS were better in PD-IMRT compared with EPP-IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolutionary characteristics of intergenic transcribed regions indicate rare novel genes and widespread noisy transcription in the Poaceae

Abstract Extensive transcriptional activity occurring in intergenic regions of genomes has raised the question whether intergenic transcription represents the activity of novel genes or noisy expression. To address this, we evaluated cross-species and post-duplication sequence and expression conservation of intergenic transcribed regions (ITRs) in four Poaceae species. Among 43,301 ITRs across the four species, 34,460 (80%) are species-specific. ITRs found across species tend to be more divergent in expression and have more recent duplicates compared to annotated genes. To assess if ITRs are functional (under selection), machine learning models were established in Oryza sativa (rice) that could accurately distinguish between phenotype genes and pseudogenes (area under curve-receiver operating characteristic = 0.94). Based on the models, 584 (8%) and 4391 (61%) rice ITRs are classified as likely functional and nonfunctional with high confidence, respectively. ITRs with conserved expression and ancient retained duplicates, features that were not part of the model, are frequently classified as likely-functional, suggesting these characteristics could serve as pragmatic rules of thumb for identifying candidate sequences likely to be under selection. This study also provides a framework to identify novel genes using comparative transcriptomic data to improve genome annotation that is fundamental for connecting genotype to phenotype in crop and model systems.

59 BASIC BIOLOGICAL SCIENCES↗

Computed axial lithography optimization system

A system for determining a light intensity field for use in manufacturing a 3D object from a volume of material. The system receives a 3D specification of a 3D geometry for the 3D object that specifies voxels within the volume that contain material that is to be part of the 3D object. The system employs a cost function for effectiveness of a light intensity field in manufacturing the 3D object. The cost function may be an adjoint of an Attenuated Radon Transform that models an energy dose that each voxel would receive during manufacture of the 3D object using the light intensity field. The system applies an optimization technique that employs the cost function to generate a measure of the effectiveness of possible light intensity fields and outputs an indication of a light intensity field that will be effective in manufacturing the 3D object.

Shusteff, Maxim↗

Inflationary correlation functions without infrared divergences

Inflationary correlation functions are potentially affected by infrared divergences. For example, the two-point correlator of curvature perturbation at momentum k receives corrections ∼ ln (kL), where L is the size of the region in which the measurement is performed. We define infrared-safe correlation functions which have no sensitivity to the size L of the box used for the observation. The conventional correlators with their familiar log-enhanced corrections (both from scalar and tensor long-wavelength modes) are easily recovered from our IR-safe correlation functions. Among other examples, we illustrate this by calculating the corrections to the non-Gaussianity parameter f{sub NL} coming from long-wavelength tensor modes. In our approach, the IR corrections automatically emerge in a resummed, all-orders form. For the scalar corrections, the resulting all-orders expression can be evaluated explicitly.

79 ASTRONOMY AND ASTROPHYSICS↗

PDB ‐101: Educational resources supporting molecular explorations through biology and medicine

Abstract The Protein Data Bank (PDB) archive is a rich source of information in the form of atomic‐level three‐dimensional (3D) structures of biomolecules experimentally determined using macromolecular crystallography, nuclear magnetic resonance (NMR) spectroscopy, and electron microscopy (3DEM). Originally established in 1971 as a resource for protein crystallographers to freely exchange data, today PDB data drive research and education across scientific disciplines. In 2011, the online portal PDB‐101 was launched to support teachers, students, and the general public in PDB archive exploration ( pdb101.rcsb.org ). Maintained by the Research Collaboratory for Structural Bioinformatics PDB, PDB‐101 aims to help train the next generation of PDB users and to promote the overall importance of structural biology and protein science to nonexperts. Regularly published features include the highly popular Molecule of the Month series, 3D model activities, molecular animation videos, and educational curricula. Materials are organized into various categories (Health and Disease, Molecules of Life, Biotech and Nanotech, and Structures and Structure Determination) and searchable by keyword. A biennial health focus frames new resource creation and provides topics for annual video challenges for high school students. Web analytics document that PDB‐101 materials relating to fundamental topics (e.g., hemoglobin, catalase) are highly accessed year‐on‐year. In addition, PDB‐101 materials created in response to topical health matters (e.g., Zika, measles, coronavirus) are well received. PDB‐101 shows how learning about the diverse shapes and functions of PDB structures promotes understanding of all aspects of biology, from the central dogma of biology to health and disease to biological energy.

Zardecki, Christine↗

Aichi Cancer Center Initial Experience of Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer Using Helical Tomotherapy

Purpose: To assess the feasibility of helical tomotherapy (HT) for patients with nasopharyngeal carcinoma. Methods and Materials: From June 2006 to June 2007, 20 patients with nasopharyngeal carcinoma were treated with HT with (n = 18) or without (n = 2) systemic chemotherapy. The primary tumor and involved lymph node (PTV1) were prescribed 70 Gy and the prophylactic region 54 Gy at D95, respectively. The majority of patients received 2 Gy per fraction for PTV1 in 35 fractions. Parotid function was evaluated using quantitative scintigraphy at pretreatment, and posttreatment at 3 months and 1 year later. Results: The median patient age was 53 years, ranging from 15 to 83. Our cohort included 5, 8, 4, 2, and 1 patients with disease Stages IIB, III, IVA, IVB, and IVC, respectively. Histopathological record revealed two for World Health Organization Type I and 18 for Type 2 or 3. The median duration time for treatment preparation was 9.5 days, and all plans were thought to be acceptable regarding dose constraints of both the planning target volume and organ at risk. All patients completed their treatment procedure of intensity-modulated radiation therapy (IMRT). All patients achieved clinical remission after IMRT. The majority of patients had Grade 3 or higher toxicity of skin, mucosa, and neutropenia. At the median follow-up of 10.9 months, two patients recurred, and one patient died from cardiac disease. Parotid gland function at 1 year after completion of IMRT was significantly improved compared with that at 3 months. Conclusion: HT was clinically effective in terms of IMRT planning and utility for patients with nasopharyngeal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiosensitization of Chemotherapy-Refractory, Locally Advanced or Locally Recurrent Breast Cancer With Trastuzumab: A Phase II Trial

Purpose: Trastuzumab (Herceptin), an anti-human epidermal growth factor receptor 2 (HER2) antibody, has been shown to be an effective radiosensitizer in preclinical studies. The present Phase II trial evaluated trastuzumab plus radiotherapy in patients with HER2-positive, chemotherapy-refractory, locally advanced or locoregionally recurrent breast cancer. Methods and Materials: Eligible patients had measurable disease, normal cardiac function, and biopsy-confirmed residual HER2-positive disease. Patients received weekly trastuzumab (2 mg/kg intravenously), concurrent with radiotherapy (50 Gy) to the breast and regional lymph nodes for 5 weeks. If feasible, surgery followed radiotherapy. The primary endpoint was safety, and the secondary endpoint was efficacy (pathologic response and interval to symptomatic local progression). Results: Of the 19 patients enrolled, 7 were ineligible and received radiotherapy alone and 12 received therapy per protocol. Of these 12 patients, 11 had a Stage T4 diagnosis. Grade 3 toxicities included skin (n = 2) and lymphopenia (n = 1). One patient experienced delayed wound healing after surgery. No patients developed symptomatic cardiac dysfunction. Of the 7 patients who had undergone mastectomy, 3 (43%) had a substantial pathologic response (complete response or microscopic residual disease), significantly more than a comparison cohort (2 of 38 or 5%, p = .02). The median interval to symptomatic local progression was not reached. The median overall survival was 39 months. Conclusion: This is the first prospective trial providing evidence for a radiosensitizing effect of trastuzumab in breast cancer. The combination of trastuzumab and radiotherapy was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity and Outcome Results of a Class Solution With Moderately Hypofractionated Radiotherapy in Inoperable Stage III Non-Small Cell Lung Cancer Using Helical Tomotherapy

Purpose: To prospectively assess the feasibility, toxicity, and local control of a class solution protocol of moderately hypofractionated tomotherapy in Stage III, inoperable, locally advanced non-small-cell lung cancer patients. Methods and Materials: Eligible patients were treated according to a uniform class solution (70.5 Gy in 30 fractions) with fixed constraints and priorities using helical tomotherapy. Toxicity monitoring was performed using the Radiation Therapy Oncology Group criteria and the National Cancer Institute Common Terminology Criteria and Adverse Events (CTCAE) version 3.0. Pulmonary function tests were performed at the start and repeated at 3 months after treatment. Results: Our class solution resulted in a deliverable plan in all 40 consecutive patients. Acute Grade 3 lung toxicity was seen in 10% of patients. Two patients died during acute follow-up with pulmonary toxicity. Correlations were found between changes in pulmonary function test results and mean lung dose or the lung volume receiving 20 Gy (V{sub 20}). The correlation was strongest for lung diffusion capacity for carbon monoxide. A V{sub 20} of >27% and >32% were predictive for Grades 2 and 3 acute lung toxicity respectively (p < 0.05). Late Grade 3 toxicity was exclusively pulmonary, with an incidence of 16%. Overall Grade 3 lung toxicity correlated with a mean lung dose of >18 Gy and a median lung dose of >5 Gy (p < 0.05). Median survival was 17 months, and the 1-year and 2-year local progression-free survivals were 66% and 50%, respectively. Conclusion: The current class solution using moderately hypofractionated helical tomotherapy in patients with locally advanced non-small-cell lung cancer is feasible. Toxicity was acceptable and in line with other reports on intensity-modulated radiotherapy. The local progression-free survival was encouraging considering the unselected population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Nonhuman Primate Model of Human Radiation-Induced Venocclusive Liver Disease and Hepatocyte Injury

Background: Human liver has an unusual sensitivity to radiation that limits its use in cancer therapy or in preconditioning for hepatocyte transplantation. Because the characteristic veno-occlusive lesions of radiation-induced liver disease do not occur in rodents, there has been no experimental model to investigate the limits of safe radiation therapy or explore the pathogenesis of hepatic veno-occlusive disease. Methods and Materials: We performed a dose-escalation study in a primate, the cynomolgus monkey, using hypofractionated stereotactic body radiotherapy in 13 animals. Results: At doses ≥40 Gy, animals developed a systemic syndrome resembling human radiation-induced liver disease, consisting of decreased albumin, elevated alkaline phosphatase, loss of appetite, ascites, and normal bilirubin. Higher radiation doses were lethal, causing severe disease that required euthanasia approximately 10 weeks after radiation. Even at lower doses in which radiation-induced liver disease was mild or nonexistent, latent and significant injury to hepatocytes was demonstrated by asialoglycoprotein-mediated functional imaging. These monkeys developed hepatic failure with encephalopathy when they received parenteral nutrition containing high concentrations of glucose. Histologically, livers showed central obstruction via an unusual intimal swelling that progressed to central fibrosis. Conclusions: The cynomolgus monkey, as the first animal model of human veno-occlusive radiation-induced liver disease, provides a resource for characterizing the early changes and pathogenesis of venocclusion, for establishing nonlethal therapeutic dosages, and for examining experimental therapies to minimize radiation injury.

62 RADIOLOGY AND NUCLEAR MEDICINE↗