Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Prospects for imaging and astrometry on the ground and implications for space interferometry

The potential imaging performance of large telescopes using adaptive optics with laser guide stars, and of interferometers using laser phased subapertures are considered. The potential astrometric performance from the ground is also discussed. For each case the implications for a space interferometry mission are considered. The advantages of the space environment for optical and infrared astronomical interferometry are: transparency at all wavelength bands, no atmospheric turbulence, and the ability to cool optics for observation in the thermal infrared. However, ground based interferometry also has important advantages: the availability of large apertures and long baselines and generally lower costs. While transparency and thermal emission are fundamental, adaptive optics aided by laser guide stars shows promise to eliminate some of the effects of turbulence for ground based imaging. Other techniques such as phase referencing and closure phase can also be used to circumvent some of the effects of atmospheric turbulence. While it is a long step from the theoretical performance predictions for a ground based instrument to their attainment, a future space imaging interferometer must emphasize those capabilities which are impossible or at least very difficult from the ground: UV observations, very high dynamic range measurements, or high resolution measurements of faint, extended objects. The case for space astrometry is more clear: while ground interferometry can offer high accuracies over very small fields, a space interferometer can offer more than two orders of magnitude better performance over wide fields than that achievable with groundbased systems.

Colavita, M. Mark↗

Vision-based range estimation using helicopter flight data

Pilot aiding during low-altitude flight depends on the ability to detect and locate obstacles near the helicopter's intended flightpath. Computer-vision-based methods provide one general approach for obstacle detection and range estimation. Several algorithms have been developed for this purpose, but have not been tested with actual flight data. This paper presents results obtained using helicopter flight data with a feature-based range estimation algorithm. A method for recursively estimating range using a Kalman filter with a monocular sequence of images and knowledge of the camera's motion is described. The helicopter flight experiment and one of four resulting datasets is briefly discussed. Finally the performance of the range estimation algorithm is explored based on comparison of the range estimates with true range measurements collected during the flight experiment.

Smith, Phillip N.↗

Vision-based range estimation using helicopter flight data

Pilot aiding during low-altitude flight depends on the ability to detect and locate obstacles near the helicopter's intended flightpath. Computer-vision-based methods provide one general approach for obstacle detection and range estimation. Several algorithms have been developed for this purpose, but have not been tested with actual flight data. This paper presents results obtained using helicopter flight data with a feature-based range estimation algorithm. A method for recursively estimating range using a Kalman filter with a monocular sequence of images and knowledge of the camera's motion is described. The helicopter flight experiment and four resulting datasets are discussed. Finally the performance of the range estimation algorithm is explored in detail based on comparison of the range estimates with true range measurements collected during the flight experiment.

Smith, Phillip N.↗

Simultaneous observations of solar plage with the solar extreme ultraviolet rocket telescope and spectrograph (SERTS), the VLA, and the Kitt Peak magnetograph

We obtained simultaneous images of solar plage on 1991, May 7 with SERTS, the VLA,4 and the NASA/National Solar Observatory spectromagnetograph at the NSO/Kitt Peak Vacuum Telescope. Using intensity ratios of Fe XVI to Fe XV emission lines, we find that the coronal plasma temperature is (2.3-2.9) x 10 exp 6 K throughout the region. The column emission measure ranges from 2.5 x 10 exp 27 to l.3 x 10 exp 28 cm exp -5. The calculated structure and intensity of the 20 cm wavelength thermal bremsstrahlung emission from the hot plasma observed by SERTS is quite similar to the observed structure and intensity of the 20 cm microwave emission observed by the VLA. Using the Meyer (1991, 1992) revised coronal iron abundance, we find no evidence either for cool absorbing plasma or for contributions from thermal gyroemission. Using the observed microwave polarization and the SERTS plasma parameters, we calculate a map of the coronal longitudinal magnetic field. The resulting values, about 30-60 G, are comparable to extrapolated values of the potential field at heights of 5000 and 10,000 km.

Brosius, Jeffrey W.↗

Novel Co:MgF2 lidar for aerosol profiler

Lidars are of great interest because of their unique capabilities in remote sensing applications in sounding of the atmosphere, meteorology, and climatology. In this small business innovative research (SBIR) phase II program, laser sources including Co:MgF2, CTH:YAG, CTH:YSGG, CT:YAG, and Er:Glass were evaluated. Modulator of fused silica and TeO2 materials with Brewster's angle end faces were used with these lasers as acousto-optical (AO) Q-switches. A higher hold-off energy and hence a higher Q-switched energy was obtained by using a high power RF driver. The report provides performance characteristics of these lasers. The tunable (1.75-2.50 microns) Co:MgF2 laser damaged the TeO2 Q-switch cell. However, the CTH:YAG laser operating at 2.09 microns provided output energy of over 300 mJ/p in 50 ns pulse width using the fused silica Q-switch. This Q-switched CTH:YAG laser was used in a breadboard vertical aerosol profiler. A 40 cm diameter telescope, InSb and InGaAs detectors were used in the receiver. The data obtained using this lidar is provided in the report. The data shows that the eye safe lidar using CTH:YAG laser for the vertical aerosol density and range measurements is the viable approach.

Acharekar, M. A.↗

Tracking capabilities of SPADs for laser ranging

The spatial sensitivity of Single-Photon Avalanche Diodes (SPADs) can be exploited in laser ranging measurements to finely tune the laser spot in the center of the detector sensitive area. We report the performance of a SPAD with l00 micron diameter. It features a time resolution better than 80 ps rms when operated 4V above V(b) at minus 30 C, and a spatial sensitivity better than 20 microns to radial displacements of the laser spot. New SPAD structures with auxiliary delay detectors are proposed. These improved devices could allow a two dimensional sensitivity, that could be employed for the design of pointing servos.

Zappa, F.↗

ETALON-1,-2 center of mass correction and array reflectivity

Center of mass correction to be applied to measured ranges to the ETALON 1 and 2 satellites is considered. Numerical values of the correction and reflectivity from the retroreflector array are computed. The variations of these values with satellite orientation are investigated.

Mironov, N. T.↗

Some results gained from JAPE: An overview

During JAPE, a variety of sound propagation experiments were conducted including long range measurements and investigations of the masking of sound by natural barriers. An overview of the measurements is given. A comparison between measured SPL's and theoretical estimates is presented.

Becker, Gunnar R.↗

Overall assessment of needs and benefits in controlled structures

The potential benefits of employing controlled structures technology in spacecraft design are illustrated using an example of a Mission-to-Planet Earth multisensor geostationary platform. The platform has a precipitation mapping sensor which requires large antennas to meet the science requirement of resolution cell size and dynamic measurement range. A series approach and an integrated approach to designing a controlled structure are discussed.

Newsom, Jerry R.↗

Global and regional kinematics with VLBI

Since a VLBI station cannot operate in isolation and since simultaneous operation of the entire VLBI network is impractical, it is necessary to design observing programs with periodic observing sessions using networks of 3-7 stations that, when treated together, will have the necessary interstation data and network overlaps to determine the desired rates of change. Thus, there has been a mix of global, intercontinental, transcontinental, and regional networks to make measurements ranging from plate motions to deformation over a few hundred km. Over time, even networks focusing on regional deformation using mobile VLBI included large stations removed by several thousand km to increase sensitivity, determine EOP more accurately, and provide better ties to the terrestrial reference frame (TRF). Analysis products have also evolved, beginning with baseline components, and then to full three-dimensional site velocities in a global TRF.

Ma, Chopo↗

Electron transport and energy degradation in the ionosphere: Evaluation of the numerical solution, comparison with laboratory experiments and auroral observations

Auroral electron transport calculations are a critical part of auroral models. We evaluate a numerical solution to the transport and energy degradation problem. The numerical solution is verified by reproducing simplified problems to which analytic solutions exist, internal self-consistency tests, comparison with laboratory experiments of electron beams penetrating a collision chamber, and by comparison with auroral observations, particularly the emission ratio of the N2 second positive to N2(+) first negative emissions. Our numerical solutions agree with range measurements in collision chambers. The calculated N(2)2P to N2(+)1N emission ratio is independent of the spectral characteristics of the incident electrons, and agrees with the value observed in aurora. Using different sets of energy loss cross sections and different functions to describe the energy distribution of secondary electrons that emerge from ionization collisions, we discuss the uncertainties of the solutions to the electron transport equation resulting from the uncertainties of these input parameters.

Lummerzheim, D.↗

Gravity recovery analysis using GPS for STEP and a low-low satellite mission

Global Positioning System (GPS) receivers on low Earth orbiting satellites can provide three-dimensional global tracking with sub-decimeter orbit accuracy. The precise GPS data can additionally be used to refine the Earth's gravity field. Satellite Test of the Equivalence Principle (STEP) is a proposed European Space Agency mission which will carry a flight GPS receiver. Using a realistic scenario for processing 5 days of GPS data, a covariance analysis is performed to obtain the expected improvement in the gravity field. Additionally, a similar analysis is then repeated for two low Earth orbiting satellites, each equipped with GPS receivers and with precise ranging measurements between them.

Muellerschroen, Ronald J.↗

Earth System science

Recent research has solidified a view of the Earth as a global-scale interactive system with complex chemical, physical, biological and dynamical processes that link the ocean, atmosphere, land (soils, ice, snow) and marine and terrestrial living organisms. These processes both within and between the major parts of the system help determine global and regional climate and control the biogeochemical and hydrologic cycles essential to life. The study of the Earth System requires measurements ranging from the scales of the smallest processes to the global scale. An ambitious satellite observational program, the Earth Observing System (EOS), carried out along with the complementary and ongoing World Climate Research Program (WCRP) and International Geosphere-Biosphere Program (IGBP) represents a major international effort to understand this System and predict its future changes. The complex and intriguing nature of the Earth System is discussed along with a number of closely coupled processes occurring within it. These are: clouds, precipitation and vegetation; ocean circulation, sea-surface temperature and phytoplankton; coupled oceanic and atmospheric circulation (the Southern Oscillation); biological activity, atmospheric chemistry and climate; and biological emissions and the ozone layer.

Prinn, R. G.↗

Optoelectronic Alignment And Ultrasonic Ranging Apparatus

Beam of light guides alignment, then range measured by use of ultrasound. Optoelectronic/ultrasonic apparatus facilitates three-dimensional alignment of spot on one object with respect to facing (but not touching) spot on another nearby object. Designed to help in positioning external tank of space shuttle between two solid rocket boosters. Useful in other applications to align large components to be locked together in assemblies.

Collins, J. David↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Sensitivity of planetary cruise navigation to earth orientation calibration errors

A detailed analysis was conducted to determine the sensitivity of spacecraft navigation errors to the accuracy and timeliness of Earth orientation calibrations. Analyses based on simulated X-band (8.4-GHz) Doppler and ranging measurements acquired during the interplanetary cruise segment of the Mars Pathfinder heliocentric trajectory were completed for the nominal trajectory design and for an alternative trajectory with a longer transit time. Several error models were developed to characterize the effect of Earth orientation on navigational accuracy based on current and anticipated Deep Space Network calibration strategies. The navigational sensitivity of Mars Pathfinder to calibration errors in Earth orientation was computed for each candidate calibration strategy with the Earth orientation parameters included as estimated parameters in the navigation solution. In these cases, the calibration errors contributed 23 to 58% of the total navigation error budget, depending on the calibration strategy being assessed. Navigation sensitivity calculations were also performed for cases in which Earth orientation calibration errors were not adjusted in the navigation solution. In these cases, Earth orientation calibration errors contributed from 26 to as much as 227% of the total navigation error budget. The final analysis suggests that, not only is the method used to calibrate Earth orientation vitally important for precision navigation of Mars Pathfinder, but perhaps equally important is the method for inclusion of the calibration errors in the navigation solutions.

Estefan, J. A.↗

Common View Time Transfer Using Worldwide GPS and DMA Monitor Stations

Analysis of the on-orbit Navstar clocks and the Global Positioning System (GPS) monitor station reference clocks is performed by the Naval Research Laboratory using both broadcast and postprocessed precise ephemerides. The precise ephemerides are produced by the Defense Mapping Agency (DMA) for each of the GPS space vehicles from pseudo-range measurements collected at five GPS and at five DMA monitor stations spaced around the world. Recently, DMA established an additional site co-located with the US Naval Observatory precise time site. The time reference for the new DMA site is the DoD Master Clock. Now, for the first time, it is possible to transfer time every 15 minutes via common view from the DoD Master Clock to the 11 GPS and DMA monitor stations. The estimated precision of a single common-view time transfer measurement taken over a 15-minute interval was between 1.4 and 2.7 nanoseconds. Using the measurements from all Navstar space vehicles in common view during the 15-minute interval, typically 3-7 space vehicles, improved the estimate of the precision to between 0.65 and 1.13 nanoseconds. The mean phase error obtained from closure of the time transfer around the world using the 11 monitor stations and the 25 space vehicle clocks over a period of 4 months had a magnitude of 31 picoseconds. Analysis of the low noise time transfer from the DoD Master Clock to each of the monitor stations yields not only the bias in the time of the reference clock, but also focuses attention on structure in the behaviour of the reference clock not previously seen. Furthermore, the time transfer provides a a uniformly sampled database of 15-minute measurements that make possible, for the first time, the direct and exhaustive computation of the frequency stability of the monitor station reference clocks. To lend perspective to the analysis, a summary is given of the discontinuities in phase and frequency that occurred in the reference clock at the Master Control Station during the period covered by the analysis.

Reid, Wilson G.↗

Validation of a Deterministic Vibroacoustic Response Prediction Model

This report documents the recently completed effort involving validation of a deterministic theory for the random vibration problem of predicting the response of launch pad structures in the low-frequency range (0 to 50 hertz). Use of the Statistical Energy Analysis (SEA) methods is not suitable in this range. Measurements of launch-induced acoustic loads and subsequent structural response were made on a cantilever beam structure placed in close proximity (200 feet) to the launch pad. Innovative ways of characterizing random, nonstationary, non-Gaussian acoustics are used for the development of a structure's excitation model. Extremely good correlation was obtained between analytically computed responses and those measured on the cantilever beam. Additional tests are recommended to bound the problem to account for variations in launch trajectory and inclination.

Caimi, Raoul E.↗