International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

Maturing Pump Technology for EVA Applications in a Collaborative Environment

The transition from low earth orbit Extravehicular Activity (EVA) for construction and maintenance activities to planetary surface EVA on asteroids, moons, and, ultimately, Mars demands a new spacesuit system. NASA's development of that system has resulted in dramatically different pumping requirements from those in the current spacesuit system. Hamilton Sundstrand, Cascon, and NASA are collaborating to develop and mature a pump that will reliably meet those new requirements in space environments and within the design constraints imposed by spacesuit system integration. That collaboration, which began in the NASA purchase of a pump prototype for test evaluation, is now entering a new phase of development. A second generation pump reflecting the lessons learned in NASA's testing of the original prototype will be developed under Hamilton Sundstrand internal research funding and ultimately tested in an integrated Advanced Portable Life Support System (APLSS) in NASA laboratories at the Johnson Space Center. This partnership is providing benefit to both industry and NASA by supplying a custom component for EVA integrated testing at no cost to the government while providing test data for industry that would otherwise be difficult or impossible to duplicate in industry laboratories. This paper discusses the evolving collaborative process, component requirements and design development based on early NASA test experience, component stand alone test results, and near term plans for integrated testing at JSCs.

Hodgson, Edward↗

Passively Q-switched side pumped monolithic ring laser

Disclosed herein are systems and methods for generating a side-pumped passively Q-switched non-planar ring oscillator. The method introduces a laser into a cavity of a crystal, the cavity having a round-trip path formed by a reflection at a dielectrically coated front surface, a first internal reflection at a first side surface of the crystal at a non-orthogonal angle with the front, a second internal reflection at a top surface of the crystal, and a third internal reflection at a second side surface of the crystal at a non-orthogonal angle with the front. The method side pumps the laser at the top or bottom surface with a side pump diode array beam and generates an output laser emanating at a location on the front surface. The design can include additional internal reflections to increase interaction with the side pump. Waste heat may be removed by mounting the crystal to a heatsink.

Li, Steven X.↗

Evaluation of Dry, Rough Vacuum Pumps

This document provides information on the testing and evaluation of thirteen dry rough vacuum pumps of various designs and from various manufacturers. Several types of rough vacuum pumps were evaluated, including scroll, roots, and diaphragm pumps. Tests included long term testing, speed curve generation, voltage variance, vibrations emissions and susceptibility, electromagnetic interference emissions and susceptibility, static leak rate, exhaust restriction, response/recovery time tests, and a contamination analysis for scroll pumps. Parameters were found for operation with helium, which often is not provided from the manufacturer

Hunter, Brian↗

Liquid Rocket Engine with Hybrid Electric Motor Driven Pump

A nuclear thermal rocket with a superconducting electric motor driven boost pump submerged within a tank of liquid hydrogen, where the boost pump is driven by both an electric motor and a turbine. The boost pump can be submerged in liquid hydrogen so that the electric motor operates as a superconducting motor. Also, a turbopump for a rocket engine can include both a turbine and an electric motor to drive the liquid oxidizer and liquid fuel pumps of the turbopump.

Pinera, Alejandro↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗

Thermal Design Challenges Posed by the Four Bed CO2 Scrubber COTS Air-Save Pump

The Four Bed Carbon Dioxide (4BCO2) scrubber Air-Save Pump (ASP) operates as part of the adsorbent bed regeneration cycle. The ASP removes residual air from the bed for return to the cabin prior to heat and vacuum exposure which drives out the CO2 regenerating the bed. 4BCO2 employs a Commercial Off-the-Shelf (COTS) scroll type air pump, repackaged in an acoustically insulated enclosure to reduce noise and mounted to a cold plate. The International Space Station (ISS) Low Temperature Loop (LTL) flow (operating between 38°F and 50°F) first cools the process air, and then flows through the cold plate, cooling the pump. This results in competing ASP thermal design goals: (1) to keep the pump and motor sufficiently cool and (2) to avoid forming condensation due to over-cooling. Surfaces below 60°F typically warrant careful consideration of condensation. A test-calibrated thermal model demonstrates such a balanced design is feasible with temperatures above 60°F. A separate, coupled fluid model predicts the potential for condensation formation, allowing risk assessment of flying with the unmodified design.

Daniel P Popok↗

Propellant Delivery via VDC Driven Pump

The SMART (Scalable Mobile Autonomous Rocket engine Test) testbed system initiative at SSC was conceived to attempt to address many of the principal cost drivers in developing and maintaining a rocket engine test facility. The system (optimized to test engines and components generating up to 10K lbf nominal thrust) is serving as a testbed for innovative technologies and processes to provide lower cost test services with a rapid test cadence and expedient turnaround times. The system can also potentially be used as a testbed to test other related technologies relevant to surface situations (e.g., moon, Mars associated with crogenic fluid management, engine/component testing, autonomous operations, etc.). This FY20 CIF project, being conducted as part of the SMART testbed system, is developing and testing a propellant delivery system via electrically driven centrifugal pumps (obviating dependence upon Multi-Layer Pressure Vessels) with configuration and operation by a minimal number of personnel. During FY20 the team identified the requirements and worked with P3 and Masten Space Systems to develop the long lead (9 months after receipt of order) items, the 400 VDC pumps, for delivery in mid FY21. Since control of the 400 VDC pump motor is not well developed the team has established heuristics to control flows in LN2 at off nominal shaft speeds to allow deep throttling of the pump in flow test scenarios. Various test scenarios including nominal i.e. high flow high pressure, high flow low pressure, low flow high pressure, low flow low pressure, minimum throttle step change, and low inlet pressure cavitation testing were developed ahead of the anticipated hardware delivery and test. FY20 COVID Stage 3 conditions restricted access to the center and hindered lab work, so efforts focused on the system design and testing plans along with the project procurement paperwork for the hardware... now with its anticipated delivery in spring FY21. Some limited access to the center is expected by spring/summer FY21 for the continuing second year (FY21) CIF project effort meant to be focused upon system integration and initial testing.

Aaron Head↗

Tribology Induced Water Pump Bearing Failure

NASA’s In-Space Propulsion facility experienced two infant mortality water pump bearing failures during a recent refurbishment campaign, the cause or causes of which were unclear. A forensic failure study was undertaken that included site visits, collection and examination of physical evidence and a bearing and pump design review. The pumps are large (2000 hp) vertical turbine design machines that utilize metallic sleeve bearings cooled and lubricated by the pumped fluid (water). Though initial possible root cause for the failures were attributed to improper fabrication and debris contamination, detailed examination of failure surfaces combined with bearing design revealed that the failure mode was thermal seizure brought on by inadequate cooling flow. An unusual contributing factor was that the use of grease as an assembly lubricant, as opposed to a fluid like oil, appears to have exacerbated the rather than alleviated the thermal runaway by blocking water flow. Resolution of the problem was achieved through the design and installation of dedicated bearing lubrication water feed system.

bearings↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

Graham, Thomas G.↗

Wien filter with integrated vacuum pump

An integral Wien filter and vacuum pump for separating charged particles or for orienting their spin direction while maintaining optimal beamline vacuum. The vacuum pump is an ion pump including one or more cylindrical Penning cells to trap and expel electrons. The Wien filter includes orthogonal electric and magnetic fields to direct particles with the desired speed through the device while deflecting particles at undesired speeds. The Wien filter includes two electrodes, one biased positive and one biased negative, a dipole magnet, and means for reversing polarity of the electrodes to flip the spin of the charged particles. Metal plates on either side of the Penning cells embed gas that is ionized by trapped electrons in the Penning cell thus creating vacuum by turning gas into solid. The two metal plates can be configured to obtain vacuum pumping via chemical gettering and for removal of noble gases.

Poelker, Bernard Matthew↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Optically pumped gradient magnetometer

A method is provided for sensing a magnetic field in a magnetic gradiometer of the kind in which pump light and light constituting an optical carrier traverse first and second atomic vapor cells that contain host atoms and that are separated from each other by a known distance. According to such method, the host atoms are prepared in a coherent superposition of two quantum states that differ in energy by an amount that is sensitive to an ambient magnetic field. Modulation of the optical carrier in the respective cells gives rise to sidebands that interfere to generate a beat frequency indicative of the magnetic field gradient. The host atoms are prepared at least in a mode that allows measurement of ambient magnetic field components perpendicular to the axis of the pump light. In such mode, the host atoms are spin-polarized by pump light while subjected to a controlled magnetic field directed parallel to the pump beam, and then the controlled magnetic field is adiabatically extinguished.

47 OTHER INSTRUMENTATION↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗