Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

WE-G-209-03: PET

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

WE-G-209-04: MRI

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

Optimization of the radio frequency power, time and cooling water temperature for pasteurization of Salmonella Typhimurium in shell eggs

Here, radio frequency (RF) power, treatment time and cooling water temperature affect inactivation of Salmonella Typhimurium in shell eggs and internal quality. Eggs were processed using 40.68 MHz RF at 30–45 W, 2.5–8 min and 30–38 °C, followed by hot water (HW) treatment at 56.7 °C for 15 min. Five conditions achieved >5 log reduction of Salmonella without observable quality change. Analyses of the longest (8 min at 30 W and 30 °C) and shortest (4.5 min at 35 W and 38 °C) treatments indicated that combined RF/HW treatments significantly (P < 0.05) preserved quality better than HW pasteurization (56.7 °C for 60 min). No significant (P ≥ 0.05) difference in egg quality was observed between the longest and shortest treatment, except that the shortest resulted in greater albumen turbidity. As the longest treatment required 78% more time and 47% more energy than the shortest, industry may wish to use the shortest RF treatment time.

59 BASIC BIOLOGICAL SCIENCES↗

New Techniques for the Next Far Ultraviolet Spectroscopic Mission

The Far Ultraviolet Spectroscopic Explorer (FUSE) has been a great success, and has addressed many critical scientific questions (Moos, et al, 2000). However, it has also highlighted the need for even more powerful instrumentation in the 900- 1200 A, regime. In particular, significantly increased effective area will permit the pursuit of additional scientific programs currently impractical or impossible with FUSE. It is unlikely that FUSE will last more than a few more years. Nor is it likely that any large scale UV-optical follow-on to HST (such as SUVO) will include the 900-1200 A, bandpass. However, FUSE remains well oversubscribed and continues to perform excellent science. Therefore, a MIDEX class mission in the next 4-6 years that could significantly improve on the FUSE capabilities would be a powerful scientific tool that would be of great utility to the astronomical community. It would open up new scientific programs if it can improve on the sensitivity of FUSE by an order of magnitude. We have identified a powerful technique for efficient, high-resolution spectroscopy in the FUV (and possibly the EUV) that may provide exactly what is needed for such a mission To achieve a factor of 10 improvement in effective area, we propose using a large (meter class), low-cost, grazing incidence metal optics. This would produced in a manner similar to the EUVE mirrors (Green, et al, 1986), using diamond turning to create the optical figure followed by uncontrolled polishing to achieve a high quality surface. This process will introduce significant figure errors that will degrade the image quality. However, if a holographic grating is employed, which has utilized the actual telescope in the recording geometry, all wavefront errors will be automatically corrected in the end-to-end spectrometer, and high quality spectroscopy will be possible with low quality (and low-cost) optics. In this way a MIDEX class FUSE can be proposed with 10 times the effective area of the current instrument.

Green, James C.↗

Influence of Processing Parameters on the Flow Path in Friction Stir Welding

Friction stir welding (FSW) is a solid phase welding process that unites thermal and mechanical aspects to produce a high quality joint. The process variables are rpm, translational weld speed, and downward plunge force. The strain-temperature history of a metal element at each point on the cross-section of the weld is determined by the individual flow path taken by the particular filament of metal flowing around the tool as influenced by the process variables. The resulting properties of the weld are determined by the strain-temperature history. Thus to control FSW properties, improved understanding of the processing parameters on the metal flow path is necessary.

Schneider, J. A.↗

HIGH ALUMINUM HLW GLASSES FOR HANFORDS WTP

The world's largest radioactive waste vitrification facility is now under construction at the United State Department of Energy's (DOE's) Hanford site. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is designed to treat nearly 53 million gallons of mixed hazardous and radioactive waste now residing in 177 underground storage tanks. This multi-decade processing campaign will be one of the most complex ever undertaken because of the wide chemical and physical variability of the waste compositions generated during the cold war era that are stored at Hanford. The DOE Office of River Protection (ORP) has initiated a program to improve the long-term operating efficiency of the WTP vitrification plants with the objective of reducing the overall cost of tank waste treatment and disposal and shortening the duration of plant operations. Due to the size, complexity and duration of the WTP mission, the lifecycle operating and waste disposal costs are substantial. As a result, gains in High Level Waste (HLW) and Low Activity Waste (LAW) waste loadings, as well as increases in glass production rate, which can reduce mission duration and glass volumes for disposal, can yield substantial overall cost savings. EnergySolutions and its long-term research partner, the Vitreous State Laboratory (VSL) of the Catholic University of America, have been involved in a multi-year ORP program directed at optimizing various aspects of the HLW and LAW vitrification flow sheets. A number of Hanford HLW streams contain high concentrations of aluminum, which is challenging with respect to both waste loading and processing rate. Therefore, a key focus area of the ORP vitrification process optimization program at EnergySolutions and VSL has been development of HLW glass compositions that can accommodate high Al{sub 2}O{sub 3} concentrations while maintaining high processing rates in the Joule Heated Ceramic Melters (JHCMs) used for waste vitrification at the WTP. This paper, reviews the achievements of this program with emphasis on the recent enhancements in Al{sub 2}O{sub 3} loadings in HLW glass and its processing characteristics. Glass formulation development included crucible-scale preparation and characterization of glass samples to assess compliance with all melt processing and product quality requirements, followed by small-scale screening tests to estimate processing rates. These results were used to down-select formulations for subsequent engineering-scale melter testing. Finally, further testing was performed on the DM1200 vitrification system installed at VSL, which is a one-third scale (1.20 m{sup 2}) pilot melter for the WTP HLW melters and which is fitted with a fully prototypical off-gas treatment system. These tests employed glass formulations with high waste loadings and Al{sub 2}O{sub 3} contents of {approx}25 wt%, which represents a near-doubling of the present WTP baseline maximum Al{sub 2}O{sub 3} loading. In addition, these formulations were processed successfully at glass production rates that exceeded the present requirements for WTP HLW vitrification by up to 88%. The higher aluminum loading in the HLW glass has an added benefit in that the aluminum leaching requirements in pretreatment are reduced, thus allowing less sodium addition in pretreatment, which in turn reduces the amount of LAW glass to be produced at the WTP. The impact of the results from this ORP program in reducing the overall cost and schedule for the Hanford waste treatment mission will be discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Melter Throughput Enhancements for High-Iron HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase glass melting rates in high waste loading glass formulations for HLW with high concentrations of iron. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and to develop new formulations with enhanced melt rate. Testing evaluated the effects of waste loading on glass properties and the maximum waste loading that can be achieved. The results from crucible-scale testing supported subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass and feed formulations on waste processing rate and product quality. The DM100 was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Midlatitude Continental Convective Clouds Experiment (MC3E) sounding network: operations, processing and analysis

The Midlatitude Continental Convective Clouds Experiment (MC3E) took place during the spring of 2011 centered in north-central Oklahoma, USA. The main goal of this field campaign was to capture the dynamical and microphysical characteristics of precipitating convective systems in the US Central Plains. A major component of the campaign was a six-site radiosonde array designed to capture the large-scale variability of the atmospheric state with the intent of deriving model forcing data sets. Over the course of the 46-day MC3E campaign, a total of 1362 radiosondes were launched from the enhanced sonde network. This manuscript provides details on the instrumentation used as part of the sounding array, the data processing activities including quality checks and humidity bias corrections and an analysis of the impacts of bias correction and algorithm assumptions on the determination of convective levels and indices. It is found that corrections for known radiosonde humidity biases and assumptions regarding the characteristics of the surface convective parcel result in significant differences in the derived values of convective levels and indices in many soundings. In addition, the impact of including the humidity corrections and quality controls on the thermodynamic profiles that are used in the derivation of a large-scale model forcing data set are investigated. The results show a significant impact on the derived large-scale vertical velocity field illustrating the importance of addressing these humidity biases.

54 ENVIRONMENTAL SCIENCES↗

Toward Robust Autotuning of Noisy Quantum dot Devices

The current autotuning approaches for quantum dot (QD) devices, while showing some success, lack an assessment of data reliability. This leads to unexpected failures when noisy or otherwise low-quality data is processed by an autonomous system. In this work, we propose a framework for robust autotuning of QD devices that combines a machine learning (ML) state classifier with a data quality control module. The data quality control module acts as a “gatekeeper” system, ensuring that only reliable data are processed by the state classifier. Lower data quality results in either device recalibration or termination. To train both ML systems, we enhance the QD simulation by incorporating synthetic noise typical of QD experiments. We confirm that the inclusion of synthetic noise in the training of the state classifier significantly improves the performance, resulting in an accuracy of 95.0(9)% when tested on experimental data. We then validate the functionality of the data quality control module by showing that the state classifier performance deteriorates with decreasing data quality, as expected. Our results establish a robust and flexible ML framework for autonomous tuning of noisy QD devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Di-CNN: Domain-Knowledge-Informed Convolutional Neural Network for Manufacturing Quality Prediction

In manufacturing, convolutional neural networks (CNNs) are widely used on image sensor data for data-driven process monitoring and quality prediction. However, as purely data-driven models, CNNs do not integrate physical measures or practical considerations into the model structure or training procedure. Consequently, CNNs’ prediction accuracy can be limited, and model outputs may be hard to interpret practically. This study aims to leverage manufacturing domain knowledge to improve the accuracy and interpretability of CNNs in quality prediction. A novel CNN model, named Di-CNN, was developed that learns from both design-stage information (such as working condition and operational mode) and real-time sensor data, and adaptively weighs these data sources during model training. It exploits domain knowledge to guide model training, thus improving prediction accuracy and model interpretability. A case study on resistance spot welding, a popular lightweight metal-joining process for automotive manufacturing, compared the performance of (1) a Di-CNN with adaptive weights (the proposed model), (2) a Di-CNN without adaptive weights, and (3) a conventional CNN. The quality prediction results were measured with the mean squared error (MSE) over sixfold cross-validation. Model (1) achieved a mean MSE of 6.8866 and a median MSE of 6.1916, Model (2) achieved 13.6171 and 13.1343, and Model (3) achieved 27.2935 and 25.6117, demonstrating the superior performance of the proposed model.

47 OTHER INSTRUMENTATION↗

Variation and Control of Process Behavior

The purpose of this work was to highlight the importance of controlling process variability for successful quality assurance (QA). We describe the method of statistical process control for characterizing and controlling a process. Traditionally, QA has been performed by comparing some important measurement (e.g., linear accelerator output) against a corresponding specification. Although useful in determining the fitness of a particular measurement, this approach does not provide information about the underlying process behavior over time. A modern view of QA is to consider the time-ordered behavior of a process. Every process displays characteristic behaviors that are independent of the specifications imposed on it. The goal of modern QA is, not only to ensure that a process is on-target, but that it is also operating with minimal variation. This is accomplished by way of a data-driven approach using process behavior charts. The development of process behavior charts, historically known as control charts, and process behavior (action) limits are described. The effect these concepts have on quality management is also discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Out of the Autoclave Fabrication of LaRC[TradeMark] PETI-9 Polyimide Laminates

The NASA Langley Research Center developed polyimide system, LaRC PETI-9, has successfully been processed into composites by high temperature vacuum assisted resin transfer molding (HT-VARTM). To extend the application of this high use temperature material to other out-of-autoclave (OOA) processing techniques, the fabrication of PETI- 9 laminates was evaluated using only a vacuum bag and oven cure. A LaRC PETI-9 polyimide solution in NMP was prepared and successfully utilized to fabricate unidirectional IM7 carbon fiber prepreg that was subsequently processed into composites with a vacuum bag and oven cure OOA process. Composite panels of good quality were successfully fabricated and mechanically tested. Processing characteristics, composite panel quality and mechanical properties are presented in this work. The resultant properties are compared to previously developed LaRC material systems processed by both autoclave and OOA techniques including the well characterized, autoclave processed LaRC PETI-5.

Cano, Robert J.↗

High Quality Doping of GaN Through Transmutation Processing

This project led to several outstanding achievements: - Computational modeling of nuclear reactions, including estimates of the production ratio and doping concentration using TALYS 1.96 based on nuclear reactions in GaN induced by gamma-ray and protons. For photonuclear transmutation doping, simulations proved that Zn/Ge ratio with 40 MeV is higher than the other energies. - Proton transmutation doping was shown to be a potential nuclear source to fabricate p-type gallium-based semiconductor materials, examined during new irradiations with Oak Ridge National Laboratory and Brookhaven National Laboratory (in 200 MeV H - –Linac). - Patent disclosure to the University of Missouri-Columbia about healing effects in GaN by radiations. - Zn-doped p-type GaN through photonuclear transmutation doping process. - The PIs made an oral presentation on the p-type characteristics of Zn-doped GaN at the Materials Research Society Fall meeting in Boston. - The last irradiation process was in progress in collaboration with Argonne National Laboratory.

36 MATERIALS SCIENCE↗

ENDF-6 Formats Manual Data Formats and Procedures for the Evaluated Nuclear Data File ENDF/B-VI and ENDF/B-VII

In December 2006, the Cross Section Evaluation Working Group (CSEWG) of the United States released the new ENDF/B-VII.0 library. This represented considerable achievement as it was the 1st major release since 1990 when ENDF/B-VI has been made publicly available. The two libraries have been released in the same format, ENDF-6, which has been originally developed for the ENDF/B-VI library. In the early stage of work on the VII-th generation of the library CSEWG made important decision to use the same formats. This decision was adopted even though it was argued that it would be timely to modernize the formats and several interesting ideas were proposed. After careful deliberation CSEWG concluded that actual implementation would require considerable resources needed to modify processing codes and to guarantee high quality of the files processed by these codes. In view of this the idea of format modernization has been postponed and ENDF-6 format was adopted for the new ENDF/B-VII library. In several other areas related to ENDF we made our best to move beyond established tradition and achieve maximum modernization. Thus, the 'Big Paper' on ENDF/B-VII.0 has been published, also in December 2006, as the Special Issue of Nuclear Data Sheets 107 (1996) 2931-3060. The new web retrieval and plotting system for ENDF-6 formatted data, Sigma, was developed by the NNDC and released in 2007. Extensive paper has been published on the advanced tool for nuclear reaction data evaluation, EMPIRE, in 2007. This effort was complemented with release of updated set of ENDF checking codes in 2009. As the final item on this list, major revision of ENDF-6 Formats Manual was made. This work started in 2006 and came to fruition in 2009 as documented in the present report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quality Control Algorithms and Proposed Integration Process for Wind Profilers Used by Launch Vehicle Systems

Impact of winds to space launch vehicle include Design, Certification Day-of-launch (DOL) steering commands (1)Develop "knockdowns" of load indicators (2) Temporal uncertainty of flight winds. Currently use databases from weather balloons. Includes discrete profiles and profile pair datasets. Issues are : (1)Larger vehicles operate near design limits during ascent 150 discrete profiles per month 110-217 seasonal 2.0 and 3.5-hour pairs Balloon rise time (one hour) and drift (up to 100 n mi) Advantages of the Alternative approach using Doppler Radar Wind Profiler (DRWP) are: (1) Obtain larger sample size (2) Provide flexibility for assessing trajectory changes due to winds (3) Better representation of flight winds.

Decker, Ryan↗

SU-F-T-251: The Quality Assurance for the Heavy Patient Load Department in the Developing Country: The Primary Experience of An Entire Workflow QA Process Management in Radiotherapy

Purpose: To implement an entire workflow quality assurance (QA) process in the radiotherapy department and to reduce the error rates of radiotherapy based on the entire workflow management in the developing country. Methods: The entire workflow QA process management starts from patient registration to the end of last treatment including all steps through the entire radiotherapy process. Error rate of chartcheck is used to evaluate the the entire workflow QA process. Two to three qualified senior medical physicists checked the documents before the first treatment fraction of every patient. Random check of the treatment history during treatment was also performed. A total of around 6000 patients treatment data before and after implementing the entire workflow QA process were compared from May, 2014 to December, 2015. Results: A systemic checklist was established. It mainly includes patient’s registration, treatment plan QA, information exporting to OIS(Oncology Information System), documents of treatment QAand QA of the treatment history. The error rate derived from the chart check decreases from 1.7% to 0.9% after our the entire workflow QA process. All checked errors before the first treatment fraction were corrected as soon as oncologist re-confirmed them and reinforce staff training was accordingly followed to prevent those errors. Conclusion: The entire workflow QA process improved the safety, quality of radiotherapy in our department and we consider that our QA experience can be applicable for the heavily-loaded radiotherapy departments in developing country.

60 APPLIED LIFE SCIENCES↗