Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision timing applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Low-Light-Shift Cesium Fountain without Mechanical Shutters

A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.

Enzer, Daphna↗

Micrometeorite Impact Test of Flex Solar Array Coupon

Spacecraft with solar arrays operate throughout the near earth environment and are increasingly planned for outer planet missions. An often overlooked test condition for solar arrays that is applicable to these missions is micrometeorite impacts and possibly electrostatic discharge (ESD) events resulting from these impacts. The Marshall Space Flight Center (MSFC) is partnering with Space Systems/Loral, LLC (SSL) to examine the results of simulated micrometeorite impacts on the electrical performance of an advanced, lightweight flexible solar array design. The test is performed at NASA MSFC's Microlight Gas Gun Facility. The SSL-provided coupons consist of three strings, each string with two solar cells in series. Five impacts will be induced at various locations on a powered test coupon under different string voltage (0 volts - 150 volts) and string current (1.1 amperes - 1.65 amperes) conditions. The maximum specified test voltage and current represent margins of 1.5 times for both voltage and current. The test parameters are chosen to demonstrate new array design robustness to any ESD event caused by plasma plumes resulting from a simulated micrometeorite impact. A second unpowered coupon will undergo two impacts: one impact on the front side and one impact on the back side. Following the impact testing, the second coupon will be exposed to a thermal cycle test to determine possible damage propagation and further electrical degradation due to thermally-induced stress. The setup, checkout, and results from the impact testing are discussed. The challenges for impact testing include precise coupon alignment to control impact location; pressure management during the impact process; and measurement of the true transient electrical response during impact on the powered coupon. Results from pre- and post-test visual and electrical functional testing are also discussed.

Wright, K. H.↗

Algorithms for Autonomous GPS Orbit Determination and Formation Flying: Investigation of Initialization Approaches and Orbit Determination for HEO

This report summarizes the efforts to date in processing GPS measurements in High Earth Orbit (HEO) applications by the Colorado Center for Astrodynamics Research (CCAR). Two specific projects were conducted; initialization of the orbit propagation software, GEODE, using nominal orbital elements for the IMEX orbit, and processing of actual and simulated GPS data from the AMSAT satellite using a Doppler-only batch filter. CCAR has investigated a number of approaches for initialization of the GEODE orbit estimator with little a priori information. This document describes a batch solution approach that uses pseudorange or Doppler measurements collected over an orbital arc to compute an epoch state estimate. The algorithm is based on limited orbital element knowledge from which a coarse estimate of satellite position and velocity can be determined and used to initialize GEODE. This algorithm assumes knowledge of nominal orbital elements, (a, e, i, omega, omega) and uses a search on time of perigee passage (tau(sub p)) to estimate the host satellite position within the orbit and the approximate receiver clock bias. Results of the method are shown for a simulation including large orbital uncertainties and measurement errors. In addition, CCAR has attempted to process GPS data from the AMSAT satellite to obtain an initial estimation of the orbit. Limited GPS data have been received to date, with few satellites tracked and no computed point solutions. Unknown variables in the received data have made computations of a precise orbit using the recovered pseudorange difficult. This document describes the Doppler-only batch approach used to compute the AMSAT orbit. Both actual flight data from AMSAT, and simulated data generated using the Satellite Tool Kit and Goddard Space Flight Center's Flight Simulator, were processed. Results for each case and conclusion are presented.

Axelrad, Penina↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Fully Self-Contained Vision-Aided Navigation and Landing of a Micro Air Vehicle Independent from External Sensor Inputs

Direct-lift micro air vehicles have important applications in reconnaissance. In order to conduct persistent surveillance in urban environments, it is essential that these systems can perform autonomous landing maneuvers on elevated surfaces that provide high vantage points without the help of any external sensor and with a fully contained on-board software solution. In this paper, we present a micro air vehicle that uses vision feedback from a single down looking camera to navigate autonomously and detect an elevated landing platform as a surrogate for a roof top. Our method requires no special preparation (labels or markers) of the landing location. Rather, leveraging the planar character of urban structure, the landing platform detection system uses a planar homography decomposition to detect landing targets and produce approach waypoints for autonomous landing. The vehicle control algorithm uses a Kalman filter based approach for pose estimation to fuse visual SLAM (PTAM) position estimates with IMU data to correct for high latency SLAM inputs and to increase the position estimate update rate in order to improve control stability. Scale recovery is achieved using inputs from a sonar altimeter. In experimental runs, we demonstrate a real-time implementation running on-board a micro aerial vehicle that is fully self-contained and independent from any external sensor information. With this method, the vehicle is able to search autonomously for a landing location and perform precision landing maneuvers on the detected targets.

autonomous landing↗

Microbial Vessel for Impedance Spectroscopy and Electrochemistry (Mvise): an Extensible, Interoperable Data Acquisition Platform for Liquid Culture Studies in Space Biology Research

The White House Office of Science and Technology Policy (OSTP) has declared 2023 to be the Year of Open Science following an initiative to democratize scientific knowledge. Simultaneously, new sensor technologies have broadened the experimental space available to bioastronautics research. With these open-science goals and technological advances in mind, we have designed and constructed a data acquisition platform for high-precision, real-time monitoring of liquid culture systems. The vessel rig is fitted with six Atlas Scientific probes (micro pH, electrical conductivity, dissolved oxygen, oxidation-reduction potential, liquid temperature, air CO2) and a custom optical density probe similar to the one on BioSentinel’s BioSensor payload. A custom dielectric spectroscopy probe is also planned. The structure of the vessel is resin 3-D printed on a hobbyist-level machine, reducing the production cost and iteration time by over 60% each while increasing extensibility. Data acquisition and storage is controlled with a standalone C state machine-based program running on a Raspberry Pi 3 Model B. When not running headless, an additional program automatically generates and updates plots for live data visualization. Validation of the rig as a data collection system was performed with a yeast liquid culture experiment. While the vessel rig is currently used for standalone experiments, it can also be used as the base perception unit in a self-driving laboratory (SDL). SDLs are high-throughput data collection systems that employ automation and artificial intelligence to conduct and manage routine experiments. Here, we envision an SDL driven by several vessel rigs in which an automated script compares key results, informing the design of future experiments. A vessel rig SDL would streamline many operations, including 1) strain selection for the Lunar Explorer Instrument for space biology Applications (LEIA) investigation and 2) the study of bioregenerative life support systems (BLSS). Ultimately, the datasets that can now be acquired will provide crucial information for accelerating bioastronautics application development in the era of commercial space.

Stephen Lantin↗

Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices

Spaceflight system electronic devices must survive a wide range of radiation environments with various particle types including energetic protons, electrons, gamma rays, x-rays, and heavy ions. High-energy charged particles such as heavy ions can pass straight through a semiconductor material and interact with a charge-sensitive region, generating a significant amount of charge (electron-hole pairs) along their tracks. These excess charges can damage the device, and the response can range from temporary perturbations to permanent changes in the state or performance. These phenomena are called single event effects (SEE). Before application in flight systems, electronic parts need to be qualified and tested for performance and radiation sensitivity. Typically, their susceptibility to SEE is tested by exposure to an ion beam from a particle accelerator. At such facilities, the device under test (DUT) is irradiated with large beams so there is no fine resolution to investigate particular regions of sensitivity on the parts. While it is the most reliable approach for radiation qualification, these evaluations are time consuming and costly. There is always a need for new cost-efficient strategies to complement accelerator testing: pulsed lasers provide such a solution. Pulsed laser light can be utilized to simulate heavy ion effects with the advantage of being able to localize the sensitive region of an integrated circuit. Generally, a focused laser beam of approximately picosecond pulse duration is used to generate carrier density in the semiconductor device. During irradiation, the laser pulse is absorbed by the electronic medium with a wavelength selected accordingly by the user, and the laser energy can ionize and simulate SEE as would occur in space. With a tightly focused near infrared (NIR) laser beam, the beam waist of about a micrometer can be achieved, and additional scanning techniques are able to yield submicron resolution. This feature allows mapping of all of the sensitive regions of the studied device with fine resolution, unlike heavy ion experiments. The problematic regions can be precisely identified, and it provides a considerable amount of information about the circuit. In addition, the system allows flexibility for testing the device in different configurations in situ.

Aveline, David C.↗

Report of the Panel on Guidance, Navigation, and Control

Guidance, navigation, and control (GNC) systems have historically been vital to improving operational capability of aircraft. The development of autopilots and electronic navigation systems has greatly aided the crew in flying precise routes in all weather conditions while at the same time reducing pilot workload. Advances in high-integrity onboard computing and electronics technology have resulted in a significant increase in the capability of these subsystems to perform more reliably, efficiently, and safely. Onboard computing and control system capability has provided new design approaches for the aircraft designer. By using automatic control systems to stabilize the aircraft, the designer can relax certain conventional aerodynamic stability requirements and achieve aircraft performance benefits. Thus, modern fighter aircraft are designed with low levels, or in fact, negative levels of longitudinal static stability to boost maneuvering capability and cruise performance, relying on the use of full-time, full-authority automatic stability augmentation systems to stabilize the aircraft. During the next 20 years, GNC systems will become a driving force in aircraft design. Instead of making separately designed major aircraft systems work together, the designer will exploit the interaction and integration of aerodynamic, structural, and propulsion system controls to provide a better aircraft. The benefits of such integrated designs have been demonstrated already. Integrated digital control of the engine inlet and autopilot systems on a NASA YF-12 research aircraft resulted in a range increase of 7 percent. A civil transport derivative using extensions on each wing and an active control system to minimize the requirement for structural modifications achieved significant cruise performance improvements. These are first-generation applications of advanced GNC systems. More significant benefits are achievable by the year 2000. Complete integration of aerodynamic, propulsion and structural controls, and mission avionics will provide dramatically better aircraft performance, new capability (low observability, supermaneuverability) and/or improved mission effectiveness. This requires a concurrent, multidisciplinary design approach early in the design stage. The role of advanced GNC systems in future aircraft is not an option.

Fraser, Donald C.↗

Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets

A proposed optoelectronic instrument would identify targets rapidly, without need to radiate an interrogating signal, apply identifying marks to the targets, or equip the targets with transponders. The instrument was conceived as an identification, friend or foe (IFF) system in a battlefield setting, where it would be part of a targeting system for weapons, by providing rapid identification for aimed weapons to help in deciding whether and when to trigger them. The instrument could also be adapted to law-enforcement and industrial applications in which it is necessary to rapidly identify objects in view. The instrument would comprise mainly an optical correlator and a neural processor (see figure). The inherent parallel-processing speed and capability of the optical correlator would be exploited to obtain rapid identification of a set of probable targets within a scene of interest and to define regions within the scene for the neural processor to analyze. The neural processor would then concentrate on each region selected by the optical correlator in an effort to identify the target. Depending on whether or not a target was recognized by comparison of its image data with data in an internal database on which the neural processor was trained, the processor would generate an identifying signal (typically, friend or foe ). The time taken for this identification process would be less than the time needed by a human or robotic gunner to acquire a view of, and aim at, a target. An optical correlator that has been under development for several years and that has been demonstrated to be capable of tracking a cruise missile might be considered a prototype of the optical correlator in the proposed IFF instrument. This optical correlator features a 512-by-512-pixel input image frame and operates at an input frame rate of 60 Hz. It includes a spatial light modulator (SLM) for video-to-optical image conversion, a pair of precise lenses to effect Fourier transforms, a filter SLM for digital-to-optical correlation-filter data conversion, and a charge-coupled device (CCD) for detection of correlation peaks. In operation, the input scene grabbed by a video sensor is streamed into the input SLM. Precomputed correlation-filter data files representative of known targets are then downloaded and sequenced into the filter SLM at a rate of 1,000 Hz. When there occurs a match between the input target data and one of the known-target data files, the CCD detects a correlation peak at the location of the target. Distortion- invariant correlation filters from a bank of such filters are then sequenced through the optical correlator for each input frame. The net result is the rapid preliminary recognition of one or a few targets.

Moynihan, Philip↗

Global Monitoring of Terrestrial Chlorophyll Fluorescence from Moderate-Spectral-Resolution Near-Infrared Satellite Measurements: Methodology, Simulations, and Application to GOME-2

Globally mapped terrestrial chlorophyll fluorescence retrievals are of high interest because they can provide information on the functional status of vegetation including light-use efficiency and global primary productivity that can be used for global carbon cycle modeling and agricultural applications. Previous satellite retrievals of fluorescence have relied solely upon the filling-in of solar Fraunhofer lines that are not significantly affected by atmospheric absorption. Although these measurements provide near-global coverage on a monthly basis, they suffer from relatively low precision and sparse spatial sampling. Here, we describe a new methodology to retrieve global far-red fluorescence information; we use hyperspectral data with a simplified radiative transfer model to disentangle the spectral signatures of three basic components: atmospheric absorption, surface reflectance, and fluorescence radiance. An empirically based principal component analysis approach is employed, primarily using cloudy data over ocean, to model and solve for the atmospheric absorption. Through detailed simulations, we demonstrate the feasibility of the approach and show that moderate-spectral-resolution measurements with a relatively high signal-to-noise ratio can be used to retrieve far-red fluorescence information with good precision and accuracy. The method is then applied to data from the Global Ozone Monitoring Instrument 2 (GOME-2). The GOME-2 fluorescence retrievals display similar spatial structure as compared with those from a simpler technique applied to the Greenhouse gases Observing SATellite (GOSAT). GOME-2 enables global mapping of far-red fluorescence with higher precision over smaller spatial and temporal scales than is possible with GOSAT. Near-global coverage is provided within a few days. We are able to show clearly for the first time physically plausible variations in fluorescence over the course of a single month at a spatial resolution of 0.5 0.5. We also show some significant differences between fluorescence and coincident normalized difference vegetation indices (NDVI) retrievals.

Fluorescence↗

Global Monitoring of Terrestrial Chlorophyll Fluorescence from Moderate-spectral-resolution Near-infrared Satellite Measurements: Methodology, Simulations, and Application to GOME-2

Globally mapped terrestrial chlorophyll fluorescence retrievals are of high interest because they can provide information on the functional status of vegetation including light-use efficiency and global primary productivity that can be used for global carbon cycle modeling and agricultural applications. Previous satellite retrievals of fluorescence have relied solely upon the filling-in of solar Fraunhofer lines that are not significantly affected by atmospheric absorption. Although these measurements provide near-global coverage on a monthly basis, they suffer from relatively low precision and sparse spatial sampling. Here, we describe a new methodology to retrieve global far-red fluorescence information; we use hyperspectral data with a simplified radiative transfer model to disentangle the spectral signatures of three basic components: atmospheric absorption, surface reflectance, and fluorescence radiance. An empirically based principal component analysis approach is employed, primarily using cloudy data over ocean, to model and solve for the atmospheric absorption. Through detailed simulations, we demonstrate the feasibility of the approach and show that moderate-spectral-resolution measurements with a relatively high signal-to-noise ratio can be used to retrieve far-red fluorescence information with good precision and accuracy. The method is then applied to data from the Global Ozone Monitoring Instrument 2 (GOME-2). The GOME-2 fluorescence retrievals display similar spatial structure as compared with those from a simpler technique applied to the Greenhouse gases Observing SATellite (GOSAT). GOME-2 enables global mapping of far-red fluorescence with higher precision over smaller spatial and temporal scales than is possible with GOSAT. Near-global coverage is provided within a few days. We are able to show clearly for the first time physically plausible variations in fluorescence over the course of a single month at a spatial resolution of 0.5 deg × 0.5 deg. We also show some significant differences between fluorescence and coincident normalized difference vegetation indices (NDVI) retrievals.

remote sensing↗

Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition

Multirate (decimation/interpolation) filters are among the essential signal processing components in spaceborne instruments where Finite Impulse Response (FIR) filters are often used to minimize nonlinear group delay and finite-precision effects. Cascaded (multi-stage) designs of Multi-Rate FIR (MRFIR) filters are further used for large rate change ratio, in order to lower the required throughput while simultaneously achieving comparable or better performance than single-stage designs. Traditional representation and implementation of MRFIR employ polyphase decomposition of the original filter structure, whose main purpose is to compute only the needed output at the lowest possible sampling rate. In this paper, an alternative representation and implementation technique, called TD-MRFIR (Thread Decomposition MRFIR), is presented. The basic idea is to decompose MRFIR into output computational threads, in contrast to a structural decomposition of the original filter as done in the polyphase decomposition. Each thread represents an instance of the finite convolution required to produce a single output of the MRFIR. The filter is thus viewed as a finite collection of concurrent threads. The technical details of TD-MRFIR will be explained, first showing its applicability to the implementation of downsampling, upsampling, and resampling FIR filters, and then describing a general strategy to optimally allocate the number of filter taps. A particular FPGA design of multi-stage TD-MRFIR for the L-band radar of NASA's SMAP (Soil Moisture Active Passive) instrument is demonstrated; and its implementation results in several targeted FPGA devices are summarized in terms of the functional (bit width, fixed-point error) and performance (time closure, resource usage, and power estimation) parameters.

DSP↗

Precise mean sea level measurements using the Global Positioning System

This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and temporal resolution higher than that available from altimeter data.

Kelecy, Thomas M.↗

Growth from Solutions: Kink dynamics, Stoichiometry, Face Kinetics and stability in turbulent flow

1. Kink dynamics. The first segment of a polygomized dislocation spiral step measured by AFM demonstrates up to 60% scattering in the critical length l*- the length when the segment starts to propagate. On orthorhombic lysozyme, this length is shorter than that the observed interkink distance. Step energy from the critical segment length based on the Gibbs-Thomson law (GTL), l* = 20(omega)alpha/(Delta)mu is several times larger than the energy from 2D nucleation rate. Here o is tine building block specific voiume, a is the step riser specific free energy, Delta(mu) is the crystallization driving force. These new data support our earlier assumption that the classical Frenkel, Burton -Cabrera-Frank concept of the abundant kink supply by fluctuations is not applicable for strongly polygonized steps. Step rate measurements on brushite confirms that statement. This is the1D nucleation of kinks that control step propagation. The GTL is valid only if l* <Dk/vk, the diffusion path of a kink that has diffusivity Dk and average growth velocity vk. This is equivalent to supersaturations sigma less than approx. alpha/2l*, where alpha is the building block size. For lysozyme, sigma much less than (1%). Conventionally used interstep distance generated by screw dislocation, 19(omega)alpha/Delta(mu) should be replaced by the very different real one, approx.4l*. 2. Stoichiometry. Kink, and thus step and face rates of a non-Kossel complex molecular monocomponent or any binary, AB, lattice was found theoretically to be proportional to 1/(zeta(sup 1/2) + zeta(sup - 1/2)), where zeta = [B]/[A] is the stoichiometry ratio in solution. The velocities reach maxima at zeta = 1. AFM studies of step rates on CaOxalate monohydrate (kidney stones) from aqueous solution was found to obey the law mentioned above. Generalization for more complex lattice will be discussed. 3. Turbulence. In agreement with theory, high precision in-situ laser interferometry of the (101) KDP crystal face shows step bunching if solution flows parallel to the step flow. The bunch height increases with the distance the bunch travels, i.e. with the face size. However, when the flow rate, u, increases, at u greater than approx. 1 m / s , the average step bunch height decreases as 1/u. The pheonomenon is attributed to the turbulent rather than laminar viscous boundary layer where diffusivity Dt = 0.5u(sub tau),y, i.e. increases linearly with the distance y from the solid face. Friction velocity, u(sub tau) approx. u(sup 7/8). Dramatically larger rate of the mass/heat transport within the turbulent, as compared to the laminar, viscous layer will be discussed.

Chernov, A. A.↗

Monolithic Flexure Pre-Stressed Ultrasonic Horns

High-power ultrasonic actuators are generally assembled with a horn, backing, stress bolt, piezoelectric rings, and electrodes. The manufacturing process is complex, expensive, difficult, and time-consuming. The internal stress bolt needs to be insulated and presents a potential internal discharge point, which can decrease actuator life. Also, the introduction of a center hole for the bolt causes many failures, reducing the throughput of the manufactured actuators. A new design has been developed for producing ultrasonic horn actuators. This design consists of using flexures rather than stress bolts, allowing one to apply pre-load to the piezoelectric material. It also allows one to manufacture them from a single material/plate, rapid prototype them, or make an array in a plate or 3D structure. The actuator is easily assembled, and application of pre-stress greater than 25 MPa was demonstrated. The horn consists of external flexures that eliminate the need for the conventional stress bolt internal to the piezoelectric, and reduces the related complexity. The stress bolts are required in existing horns to provide prestress on piezoelectric stacks when driven at high power levels. In addition, the manufacturing process benefits from the amenability to produce horn structures with internal cavities. The removal of the pre-stress bolt removes a potential internal electric discharge point in the actuator. In addition, it significantly reduces the chances of mechanical failure in the piezoelectric stacks that result from the hole surface in conventional piezoelectric actuators. The novel features of this disclosure are: 1. A design that can be manufactured from a single piece of metal using EDM, precision machining, or rapid prototyping. 2. Increased electromechanical coupling of the horn actuator. 3. Higher energy density. 4. A monolithic structure of a horn that consists of an external flexure or flexures that can be used to pre-stress a solid piezoelectric structure rather than a bolt, which requires a through hole in the piezoelectric material. 5. A flexure system with low stiffness that accommodates mechanical creep with minor reduction in pre-stress.

Sherrit, Stewart↗

Advancing Metasurfaces Towards New Frontiers: Nonvolatile Reconfigurable Optics

The applications of adaptive optics extend across multiple sectors, encompassing areas such as LiDAR, biological and chemical sensing, and free-space communications. In this study, we report on the design, fabrication, testing, and modeling of electrically reconfigurable metasurfaces using a low-loss high contrast phase change material, Ge2Sb2Se4Te integrated with an IR-transparent silicon microheater. Through this work, we introduce a reliable architecture for switching PCM-based metasurfaces within an integrated circuit configuration which is compatible with standard foundry fabrication processes. We demonstrate the capability of controlling the transmission of electromagnetic waves through the precise stimulation of PCM-based pixels, each spanning a few hundred microns, over numerous cycles. By leveraging PCM-based pixels, we unlock the potential to create metasurfaces encompassing a diverse range of functionalities such as dielectric filters, metalens, or beam steering devices, which is governed by the design of the meta-atoms. Further, we perform an in-depth investigation into the failure mechanism utilizing techniques such as Fourier transform IR spectroscopy (FTIR), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and thermal modeling. According to our results, due to a sharp temperature rise at the PCM/heater interface, we observe severe delamination of the PCM from the heater. More uniform PCM deposition, better adhesion at the PCM/heater interface, and a more uniform temperature distribution in the device could potentially mitigate the failure and lead to a longer life-time. By addressing these challenges, we aim to unlock the full potential of PCM-based devices and advance the field of adaptive optics.

Phase change material↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The soil column diameter was tested at three levels using pipes with inner diameters measuring 5.08, 10.16, and 15.24 centimeters (2, 4, and 6 inches). Soil was filled in each pipe to form 15, 30, and 45 centimeter (6, 12, and 18 inch) tall soil columns. Each diameter/height configuration was also tested at three levels of soil compaction, compared by calculating the bulk density of the soil with mass and volume measurements. GRC-1a simulant was used, with approximate low/medium/high bulk densities of 1.6, 1.75, and 1.9 g/cc achieved with a combination of vibration and tamping. The order of tests for a given column diameter was randomized and repeated three times. With the top of the soil open to atmosphere at room temperature, compressed air was injected through a small diffuser at the column base with several small downward-facing holes. The number and size of these holes was scaled such that a constant total inlet orifice area to column cross sectional area ratio was maintained for each column diameter. Inlet air pressure was slowly increased via a precision regulator to preserve quasi-static equilibrium in the soil column to minimize the impact of dynamics. Air pressure was increased all the way through the static and bubbling regimes until slugging or turbulent behavior was observed in the soil to ensure that the entire static regime had been captured during data collection. A three-factor, three-level analysis of variance (ANOVA) statistical analysis was performed on the resulting data to determine the extent to which each physical parameter impacted the soil column seal performance. It was concluded that there is statistically significant evidence that column height, and the interaction between column height and diameter impact soil seal performance. In all other cases there was insufficient data to identify a statistically significant causal relationship. Additionally, plots were generated comparing experimental data to the predictive formula developed by Ogino et al. for fluidized beds in 1993. Because this model was developed for industrial spouted fluidized beds, the accuracy of its output prior to fluidization in the static seal ‘edge case’ is unknown, especially considering in this application the working gas was diffused across the column base rather than being injected through a spout. Further, the fidelity of the model had not yet been tested with lunar soil simulants. Plotting the Ogino et al. model alongside test data allows for a more intuitive sense of the impact of test parameters on soil seal performance, as well as providing a quick means to further tune this predictive model for more accurate use with static seals across granular lunar soil simulants. The model provided by Ogino et al. was further tuned using test data to determine the degree to which a spouted bed model could be applied to a slightly modified set of testing conditions: lunar soil simulants and a more diffuse, homogeneous application of pneumatic pressure. A Matlab script was created to test different values for the leading coefficient and exponents in Ogino’s formula. The script swept preset ranges, then iterated with higher resolutions across narrower ranges to converge on the optimal value for each parameter. The resulting adjusted model was compared to the original, as well as test data with noticeable improvements across the entire test domain.

Jack Stewart↗