Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The Impact on Space Radiation Requirements and Effects on ASIMS

The evolution of highly miniaturized electronic and mechanical systems will be accompanied by new problems and issues regarding the radiation response of these systems in the space environment. In this paper we discuss some of the more prominent radiation problems brought about by miniaturization. For example, autonomous micro-spacecraft will require large amounts of high density memory, most likely in the form of stacked, multichip modules of DRAM's, that must tolerate the radiation environment. However, advanced DRAM's (16 to 256 Mbit) are quite susceptible to radiation, particularly single event effects, and even exhibit new radiation phenomena that were not a problem for older, less dense memory chips. Another important trend in micro-spacecraft electronics is toward the use of low-voltage microelectronic systems that consume less power. However, the reduction in operating voltage also caries with it an increased susceptibility to radiation. In the case of application specific integrated microcircuits (ASIM's), advanced devices of this type, such as high density field programmable gate arrays (FPGA's) exhibit new single event effects (SEE), such as single particle reprogramming of anti-fuse links. New advanced bipolar circuits have been shown recently to degrade more rapidly in the low dose rate space environment than in the typical laboratory total dose radiation test used to qualify such devices. Thus total dose testing of these parts is no longer an appropriately conservative measure to be used for hardness assurance. We also note that the functionality of micromechanical Si-based devices may be altered due to the radiation-induced deposition of charge in the oxide passivation layers.

Barnes, C.↗

Toward a Dynamically Reconfigurable Computing and Communication System for Small Spacecraft

Future science missions will require the use of multiple spacecraft with multiple sensor nodes autonomously responding and adapting to a dynamically changing space environment. The acquisition of random scientific events will require rapidly changing network topologies, distributed processing power, and a dynamic resource management strategy. Optimum utilization and configuration of spacecraft communications and navigation resources will be critical in meeting the demand of these stringent mission requirements. There are two important trends to follow with respect to NASA's (National Aeronautics and Space Administration) future scientific missions: the use of multiple satellite systems and the development of an integrated space communications network. Reconfigurable computing and communication systems may enable versatile adaptation of a spacecraft system's resources by dynamic allocation of the processor hardware to perform new operations or to maintain functionality due to malfunctions or hardware faults. Advancements in FPGA (Field Programmable Gate Array) technology make it possible to incorporate major communication and network functionalities in FPGA chips and provide the basis for a dynamically reconfigurable communication system. Advantages of higher computation speeds and accuracy are envisioned with tremendous hardware flexibility to ensure maximum survivability of future science mission spacecraft. This paper discusses the requirements, enabling technologies, and challenges associated with dynamically reconfigurable space communications systems.

Kifle, Muli↗

Severe Space Weather Events--Understanding Societal and Economic Impacts: A Workshop Report - Extended Summary

The effects of space weather on modern technological systems are well documented in both the technical literature and popular accounts. Most often cited perhaps is the collapse within 90 seconds of northeastern Canada's Hydro-Quebec power grid during the great geomagnetic storm of March 1989, which left millions of people without electricity for up to 9 hours. This event exemplifies the dramatic impact that severe space weather can have on a technology upon which modern society critically depends. Nearly two decades have passed since the March 1989 event. During that time, awareness of the risks of severe space weather has increased among the affected industries, mitigation strategies have been developed, new sources of data have become available, new models of the space environment have been created, and a national space weather infrastructure has evolved to provide data, alerts, and forecasts to an increasing number of users. Now, 20 years later and approaching a new interval of increased solar activity, how well equipped are we to manage the effects of space weather? Have recent technological developments made our critical technologies more or less vulnerable? How well do we understand the broader societal and economic impacts of severe space weather events? Are our institutions prepared to cope with the effects of a 'space weather Katrina,' a rare, but according to the historical record, not inconceivable eventuality? On May 22 and 23, 2008, a one-and-a-half-day workshop held in Washington, D.C., under the auspices of the National Research Council's (NRC's) Space Studies Board brought together representatives of industry, the federal government, and the social science community to explore these and related questions. The key themes, ideas, and insights that emerged during the presentations and discussions are summarized in 'Severe Space Weather Events--Understanding Societal and Economic Impacts: A Workshop Report' (The National Academies Press, Washington, D.C., 2008), which was prepared by the Committee on the Societal and Economic Impacts of Severe Space Weather Events: A Workshop. The present document is an expanded summary of that report.

Source record↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid: Preprint

Power System is a complex system, with an objective to provide power to the customers. The objective is driven by a complex consideration of the secure, economic and resilient operation of the system. With the growing occurrence of extreme events emphasis has been shifted towards making the grid more resilient. However, an economic operation is still a priority for the utilities as well as its customers. Many utilities especially small isolated micro-grids do not emphasize much on an economic and resilient operation, but more on reliability. In this research we focus on striking a balance between economic and resilientoperation, ensuring reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-extreme-event restoration using linear topological constraints and DER scheduling to enhance distribution system resilience

In this paper, a post-extreme-event restoration (PEER) algorithm is proposed to improve distribution system resilience. Linear topological constraints are proposed to ensure radial topology after N-k contingencies, possibly in multiple islands. The approach is made comprehensive by considering dispatchable distributed energy resources (DERs), non-dispatchable DERs, and demand responses, as well as on-load tap changers (OLTCs) and shunt capacitors. The goal is to minimize the accumulative expense caused by load reduction payment or penalty, as well as DER operation cost. As a result, the overall system will survive longer with higher resilience during an extreme event. To verify the effectiveness of the PEER algorithm, we proposed a resilience evaluation algorithm using Monte Carlo simulation (MCS) with reduced scenarios. This is based on a probabilistic model for generating random scenarios which consider the uncertainty of line faults and solar irradiance. Combined with the proposed PEER algorithm, this reduced-scenario MCS can evaluate the expected energy not served (EENS) which is an essential index for distribution system resilience. Case studies of the IEEE 33-bus and 123-bus test systems validate the proposed algorithm in reducing EENS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA Planning for Orion Multi-Purpose Crew Vehicle Ground Operations

The NASA Orion Ground Processing Team was originally formed by the Kennedy Space Center (KSC) Constellation (Cx) Project Office's Orion Division to define, refine and mature pre-launch and post-landing ground operations for the Orion human spacecraft. The multidisciplined KSC Orion team consisted of KSC civil servant, SAIC, Productivity Apex, Inc. and Boeing-CAPPS engineers, project managers and safety engineers, as well as engineers from Constellation's Orion Project and Lockheed Martin Orion Prime contractor. The team evaluated the Orion design configurations as the spacecraft concept matured between Systems Design Review (SDR), Systems Requirement Review (SRR) and Preliminary Design Review (PDR). The team functionally decomposed prelaunch and post-landing steps at three levels' of detail, or tiers, beginning with functional flow block diagrams (FFBDs). The third tier FFBDs were used to build logic networks and nominal timelines. Orion ground support equipment (GSE) was identified and mapped to each step. This information was subsequently used in developing lower level operations steps in a Ground Operations Planning Document PDR product. Subject matter experts for each spacecraft and GSE subsystem were used to define 5th - 95th percentile processing times for each FFBD step, using the Delphi Method. Discrete event simulations used this information and the logic network to provide processing timeline confidence intervals for launch rate assessments. The team also used the capabilities of the KSC Visualization Lab, the FFBDs and knowledge of the spacecraft, GSE and facilities to build visualizations of Orion pre-launch and postlanding processing at KSC. Visualizations were a powerful tool for communicating planned operations within the KSC community (i.e., Ground Systems design team), and externally to the Orion Project, Lockheed Martin spacecraft designers and other Constellation Program stakeholders during the SRR to PDR timeframe. Other operations planning tools included Kaizen/Lean events, mockups and human factors analysis. The majority of products developed by this team are applicable as KSC prepares 21st Century Ground Systems for the Orion Multi-Purpose Crew Vehicle and Space Launch System.

Letchworth, Gary↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Bulk Grid Frequency Support Using Electrolyzers

Increasing renewable penetration in the bulk power systems has resulted in declining inertial response of the generation during system disturbances. This results in larger frequency deviations and oscillations during such events. This paper proposes a strategy for controlled dispatch of electrolyzers as loads to improve the system’s frequency response. A droop based controller with constraints based on electrolyzer operating limits has been developed to regulate its load. Consecutively, a localized frequency based control strategy has been developed to support the bulk system during disturbances. The impact of the electrolyzer support has been demonstrated using the 23-bus SAVNW system, and the 240-bus WECC system for baseline, 25% and 50% renewable penetration. The impact of changing droop settings and the available controllable electrolyzer capacities on the system’s frequency response has also been presented. Overall, the dispatchable electrolyzers helps improve (reduce) both the maximum frequency deviation and the settling times during common disturbances like loss of load/generation, and line faults. Systems with lower inertia were seen to benefit more from the controlled electrolyzer dispatch.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Demystifying Cyberattacks: Potential for Securing Energy Systems With Explainable AI : Preprint

Modernization of energy systems has led to in- creased interactions among multiple critical infrastructures and diverse stakeholders making the challenge of operational decision making more complex and at times beyond cognitive capabilities of human operators. The state-of-the-art machine learning and deep learning approaches show promise of supporting users with complex decision-making challenges, such as those occurring in our rapidly transforming cyber-physical energy systems. However, successful adoption of data-driven decision support technology for critical infrastructure will be dependent on the ability of these technologies to be trustworthy and contextually interpretable. In this paper, we investigate the feasibility of implementing XAI for interpretable detection of cyberattacks in the energy system. Leveraging a proof-of-concept simulation use case of detection of a data falsification attack on a photovoltaic system using XGBoost algorithm, we demonstrate how Local Interpretable Model-Agnostic Explanations (LIME), a flavor XAI approach, can help provide contextual and actionable interpretation of cyberattack detection.

artificial intelligence↗

Losing Control of Your Linear Network? Try Resilience Theory

Resilience of cyber-physical networks to unexpected failures is a critical need widely recognized across domains. For instance, power grids, telecommunication networks, transportation infrastructures, and water treatment systems have all been subject to disruptive malfunctions and catastrophic cyberattacks. Following such adverse events, we investigate scenarios where a node of a linear network suffers a loss of control authority over some of its actuators. These actuators are not following the controller's commands and are instead producing undesirable outputs. The repercussions of such a loss of control can propagate and destabilize the whole network despite the malfunction occurring at a single node. To assess system vulnerability, we establish resilience conditions for networks with a subsystem enduring a loss of control authority over some of its actuators. Furthermore, we quantify the destabilizing impact on the overall network when such a malfunction perturbs a nonresilient subsystem. We illustrate our resilience conditions on two academic examples, on an islanded microgrid and on the linearized IEEE 39-bus system.

97 MATHEMATICS AND COMPUTING↗

2021 NIRT Mini Drill (After Action Report)

During the summer and fall of 2021, several functional area drills were held that focused on exercising Consequence Management’s (CM) ability to extract and use data from RadResponder for the purpose of answering intermediate-phase questions presented as technical inject requests for information (RFI) in Sandia National Laboratories (SNL) Consequence Management Operational System (COSMOS) software. The scenario chosen was that of Northern Lights 2016 (NL16) which was a large-scale nuclear power plant (NPP) release exercise in the state of Minnesota. The NL16 data was extracted from the Radiological Assessment and Monitoring System (RAMS) event where it was created and was reformatted for implanting to a new RadResponder event. Next, the beta-version of a laboratory sample data simulator was used to generate more sample data that was injected to the event. Five “mini-drills” were devised with each prompt defined by a data-based need. For each drill, a team of assessment and NARAC scientists worked the problem using the drill prompt and the available data in RadResponder. The teams held a kickoff meeting, had several days to work the problem, and then reported their results as well as observations in a hotwash. Several areas for improvement in both the software and process were identified during the course of these drills. This report will document the process of addressing each RFI and the discovered gaps in both software capability and methodology so that they can be considered for future development and investment by the CM and NIRT programs.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interaction of the ABL with stratocumulus and cumulus cloud layers, appendix N

The role of the atmospheric boundary layer (ABL) over the oceans which in the general circulation of the atmosphere is to supply moisture to cumulus and stratus clouds is outlined. In extreme weather events, such as powerful storms and intense droughts, the primary role of the ABL is to supply or deny moisture to the weather system. Even for routine weather regimes, cloudiness and precipitation are key elements of any forecast. The premier problem for ABL parameterization is to formulate the physical coupling between the ABL turbulence and the clouds.

Randall, D. A.↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

The Nature of Standing Plasma Waves Following Fast Breakdown in Thunderstorms

Narrow bipolar events (NBEs) are produced by large-scale systems of streamer corona discharges that occur inside thunderstorms and radiate intensely at very-high frequencies. Here we examine 14 high-power NBEs recorded in Florida which are followed by a lasting oscillatory signal. We isolate the dominant frequencies of the oscillations using empirical mode decomposition methods, and cross-reference this information with the radiator size inferred from broadband interferometry. We conclude that the oscillations are evidence of a standing electromagnetic wave in the plasma cavity created by the preceding streamer system, that is, the cavity's fundamental mode with wavelength equal to twice the radiator length. Contrasting the dispersive and attenuation properties of these waves across several different events allows us to conclude that the cavity is filled with ions resulting in an average conductivity of 0.01–0.1 mS/m, which are left behind after the streamers decay via electron attachment to oxygen molecules.

58 GEOSCIENCES↗

New data-driven approach to bridging power system protection gaps with deep learning

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this paper, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A combined convolutional neural network and long short-term memory (CNN-LSTM) network is implemented to achieve data translation invariance and capture the temporal correlation of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN-LSTM--based method avoids the complicated, manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on two kinds of protection gaps: high-impedance faults and transformer inter-turn faults. Lastly, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

42 ENGINEERING↗

Smoke from 2020 United States wildfires responsible for substantial solar energy forecast errors

Abstract The 2020 wildfire season (May through December) in the United States was exceptionally active, with the National Interagency Fire Center reporting over 10 million acres ( > 40 000 km 2 ) burned. During the September 2020 wildfire events, large concentrations of smoke particulates were emitted into the atmosphere. As a result, smoke was responsible for ∼10%–30% reduction in solar power production during peak hours as recorded by the California Independent System Operator (CAISO) sites. In this study, we focus on a 9 d period in September when wildfire smoke had a profound impact on solar energy production. During the smoke episodes, hour-ahead forecasts utilized by CAISO did not include the effects of smoke and therefore overestimated the expected power production by ∼10%–50%. Here we use multiple observational networks and a numerical weather prediction (NWP) model to show that the wildfire events of 2020 had a significantly detrimental influence on solar energy production due to high aerosol loading. We find that including the contribution of biomass burning particles greatly improves the day-ahead solar energy bias forecast of both global horizontal irradiance and direct normal irradiance by nearly ∼50%. Our results suggest that a more comprehensive treatment of aerosols, including biomass burning aerosols, in NWP models may be an important consideration for energy grid balancing, in addition to solar resource assessment, as solar power reliance increases.

14 SOLAR ENERGY↗