Top-Down Control Design Strategy for Electric Power Grid EMP (E3) Protection
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Prior efforts have shown that deep reinforcement learning (DRL) may provide a new method for controlling networked power systems. Though successful, prior approaches have not yet demonstrated their behavior on systems of realistic scale. This effort examined multiple theoretical and technical approaches to allow a DRL model to operate over a system of 2,000 buses or more. We find that allowing the DRL models to run training episodes in parallel provides near limitless efficiency gains, allowing us to train successful agents to behave on our Kuramoto transmission model of up to 4,000 buses. We further show that we can expand our PowerWorld DRL implementation to systems of up to 25 buses but struggle to go beyond this limit due to PowerWorld’s inability to run multiple instances at once. Finally, we examine a multi-agent approach and find that it performs as well if not better than our existing centralized approach.
Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.
Validate and model impacts of electric vehicle (EV) home charging on service transformers; analyze diverse grid locations and configurations to determine 'risk factors'; finalize/deliver new design tools and typical EV load curves; improve/issue new construction standards for transformers, secondaries, and services. To ensure residential charging equity, smart charge management strategies will be studied and analyzed with the goal of creating affordable demand charges for customers.
With the increasing connectedness and interdependence of systems that are stochastic in nature, the issue of how to manage and coordinate them for safe operation has evidently become more important. In many networked system architectures, the system-wide output must be delicately managed, often within a prescribed set of bounds. In this paper, a novel control framework is proposed where the bounds on the outputs are translated into independent bounds on the controllable inputs of each subsystem. The main benefit of this framework is that respecting the individual control bounds suffices to guarantee that the system-wide outputs will remain within safe boundaries. Because the systems are assumed to be stochastic, the bounds on the output are introduced as probabilistic chance constraints. The benefits of this framework are demonstrated by applying it to the control of distributed energy resources in a distribution network where the main goal is to keep the voltage magnitudes within their prescribed bounds. The control bounds are evaluated using real data on an IEEE test system.
Mechanical ventilation (MV), although life-saving, is associated with chronic respiratory morbidity in both preterm and term born infants. New ventilation modes have been developed with the aim of minimising lung injury. These include invasive and non-invasive respiratory support strategies, techniques for less invasive surfactant administration (LISA) and closed-loop automated oxygen control (CLAC) systems. Increasingly, newborn infants with signs of respiratory distress are stabilised on continuous positive airway pressure (CPAP) and receive LISA. Early CPAP when compared to mechanical ventilation reduced the incidence of BPD and respiratory morbidity at 18 to 22 months corrected age. Nasal intermittent positive pressure ventilation reduced treatment failure rates compared to CPAP, but not bronchopulmonary dysplasia (BPD). LISA compared with intubation and surfactant delivery reduced BPD, but there is no evidence from randomised trials regarding long-term respiratory and neurodevelopmental outcomes. Synchronisation of positive pressure inflations with the infant's respiratory efforts used with volume targeting should be applied for infants requiring intubation as this strategy reduces BPD. A large RCT with long term follow up data demonstrated that prophylactic high frequency oscillatory ventilation (HFOV) improved respiratory and functional outcomes at school age, but those effects were not maintained after puberty. CLAC systems appear promising, but their effect on long term clinical outcomes has not yet been explored in randomised trials. Further studies are required to determine the role of newer ventilation modes such as neurally adjusted ventilator assist (NAVA). All such respiratory support strategies should be tested in randomised controlled trials powered to assess long-term outcomes.
Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and
This paper proposes a computationally efficient mixed integer linear programming (MILP) model for the coordinated optimization of solid-state power substations (SSPSs) in a feeder considering the full unbalanced three-phase structure of the distribution grid and its characteristics. The proposed model determines the optimal real and reactive power of each SSPS at the point of common coupling (PCC) that minimizes the operating cost and maximizes the system performance, e.g., voltage regulation and phase balancing. To improve the computational efficiency, an inscribed octagon is introduced to approximate the quadratic capacity constraints of components. Numerical simulation results show the effectiveness of the proposed model and significant improvements in voltage profiles and power imbalance between phases.
General Attributes of Modular Prismatic and Pebble Bed HTGRs Common features and physics Neutronics Thermal-Fluidics Plant Systems and Power Conversion Instrumentation and Control Normal Operation and Power Maneuvers
For distributed generation installations, the transient response of the power generation system is critical to meet power quality (voltage and frequency) requirements. Transient models for gas turbine and supercritical carbon dioxide (sCO2) power cycle were integrated for an exhaust heat recovery bottoming cycle system for a distributed generation application. The transient model for the SGT-750 Siemens gas turbine was a ‘black-box’ functional mockup interface (FMI) model developed by Siemens Industrial Turbomachinery in $Finsp\mathring{a}ng$, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8 °C.
With the increasing connectedness and interdependence of systems that are stochastic in nature, the issue of how to manage and coordinate them for safe operation has evidently become more important. In many networked system architectures, the system-wide output has to be delicately managed; often within a prescribed set of bounds. In this paper, a novel control framework is proposed where the bounds on the outputs are translated into independent bounds on the controllable inputs of each subsystem. The main benefit of this framework is that respecting the individual control bounds suffices to guarantee that the system-wide outputs will remain within safe boundaries. Since the systems are assumed to be stochastic, the bounds on the output are introduced as probabilistic chance constraints. The benefits of this framework are demonstrated by applying it to the control of distributed energy resources in a distribution networks where main goal is to keep the voltage magnitudes with their prescribed bounds. The control bounds are evaluated using real data on an IEEE test system.
In recent years, the design and development of wave energy converters (WECs) has been explored with intense interest, with highly varying design concepts emerging globally across both research enterprises and industry. The design space for WECs is vast - many concepts ranging in functionality, control systems, power development systems, materials, and scale have been ideated and prototyped, but WEC technology has yet to converge. One critical element of the technology trajectory that governs the speed of adoption is the performance of a WEC concept. In analogous but more-established industries (such as aerospace, and environmentally sustainable electronics design), performance assessment is a quantitative method, based on historical data, that is used as an iterative tool to improve the design of these systems early on in the design process. Though more nascent than these approaches, in wave energy R&D, WEC performance has been assessed using the Technology Performance Level (TPL) assessment, which provides designers with a quantitative score, situating a grid-scale WEC concept on a scale from 1-9 (1 being the lowest performance, and 9 being the highest, trending with the oft-used Technology Readiness Level, or TRL). The TPL assessment is designed to be used during design iteration, when a WEC concept is fully ideated, to enable designers to consider potential means of improving the downstream performance of the concept. One concern that may be slowing the adoption of TPL among WEC developers is the inherent uncertainty in the assessment, and how uncertainty in the individual questions asked as part of the assessment may contribute to perceived inaccuracies in the final score. In this work, we explore the uncertainty present in the assessment and quantify this uncertainty using both traditional mathematical operations and a Monte Carlo simulation. Results imply areas of improvement of the TPL assessment, where reducing uncertainty will be most helpful to end users, enabling both TPL practitioners and users to understand with more accuracy those design elements that can be improved to impact device performance most substantively.
The increasing popularity of Electric Vehicles (EVs) in the distribution grid along with technological advancement in EV electronics such as vehicle to grid (V2G) technique has enabled them to participate in grid ancillary services. To achieve this, the EVs need to establish a contract with third-party aggregators and connect to a charging unit, either residential or commercial. At any time they are connected, the EVs can decide to take part in the ancillary services program offered to them by the aggregators. If agreed, the aggregators will use the EVs as a power source capable of charging/discharging power according to the input signal, and in return, they will be compensated. This inter-temporal nature of charging/discharging is also transforming the traditional optimal power flow (OPF) problem into a dynamic OPF problem. This chapter aims at developing a multi-layer time-dependent optimization algorithm to utilize EV potential and provide ancillary services while maximizing its utilization function. Specifically, in the upper layer, an autonomous distributed ADMM algorithm is developed to optimize the cost for charging/discharging EVs while using them to regulate the voltage at each bus in the distribution grid. The distributed ADMM algorithm is also expanded to the lower layer where the individual EVs active and reactive power is controlled for voltage regulation while maintaining the desired state of the charge of the vehicle at the end of the charging period. Here, the effectiveness and performance improvement of the proposed multi-layer algorithm is illustrated through analytical analysis and simulation results.
The increasing popularity of Electric Vehicles (EVs) in the distribution grid along with technological advancement in EV electronics such as vehicle to grid (V2G) technique has enabled them to participate in grid ancillary services. To achieve this, the EVs need to establish a contract with third-party aggregators and connect to a charging unit, either residential or commercial. At any time they are connected, the EVs can decide to take part in the ancillary services program offered to them by the aggregators. If agreed, the aggregators will use the EVs as a power source capable of charging/discharging power according to the input signal, and in return, they will be compensated. This inter-temporal nature of charging/discharging is also transforming the traditional optimal power flow (OPF) problem into a dynamic OPF problem. This chapter aims at developing a multi-layer time-dependent optimization algorithm to utilize EV potential and provide ancillary services while maximizing its utilization function. Specifically, in the upper layer, an autonomous distributed ADMM algorithm is developed to optimize the cost for charging/discharging EVs while using them to regulate the voltage at each bus in the distribution grid. The distributed ADMM algorithm is also expanded to the lower layer where the individual EVs active and reactive power is controlled for voltage regulation while maintaining the desired state of the charge of the vehicle at the end of the charging period. The effectiveness and performance improvement of the proposed multi-layer algorithm is illustrated through analytical analysis and simulation results.
The Big Adaptive Rotor (BAR) Project looks at potential innovative pathways for future land-based wind turbine technology. BAR is led by the National Renewable Energy Laboratory and is sponsored by the Wind Energy Technology Office of the US Department of Energy. This talk will describe innovations and challenges faced by the teams working on BAR. The innovations include numerical models predicting the stability and performance of highly flexible blades, downwind rotors to maximize wind farm power, and controlled bending of 100-meter-long blades during rail transport. The challenges of developing predictive numerical models and formulating successful value propositions supporting new technologies such as distributed aero control devices will also be discussed.
This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.
Battery energy storage systems (BESS), inverters, and associated digital equipment are integral pieces of interdependent energy delivery systems. When considering the supply chain security of such systems, there is often a misplaced focus on the origin of energy generation and storage materials like battery cells, overlooking the more significant cyber risks that stem from digital power electronics control systems. Part of this misplaced focus is due to the relative costs of these components, with more attention given to expensive raw materials rather than the impactful digital elements themselves. The Idaho National Laboratory (INL) is addressing this gap in supply chain security through a systems-of-systems approach that considers the impact various components in digital energy systems can have should misoperation occur. Therefore, INL assigns a cyber criticality score based on quantitative analysis, which enables informed prioritization of mitigations and allows operators to reduce risk in light of the prevalence of a BESS and associated systems foreign supply chain.
The linear accelerator (LINAC) quadrupole magnets are powered by 42 silicon-controlled rectifier (SCR) based power supplies at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory. These 35V, 525A power supplies are bulky, inefficient and require both air and water cooling. The reliability of the SNS facility is impacted due to water leaks internal to power supplies and current readback issues associated with their unique control system interface, resulting in multiple downtime events. Hence, an alternate solution is necessary for the continued reliable operation of the SNS. To mitigate the above-mentioned problems, this paper proposes the use of off-the-shelf Switch Mode Power Supplies (SMPS) rated for 20V, 500A with serial control interface. These SMPS are air-cooled, more efficient and more compact owing to their switching speeds of approximately 160 kHz. The performance enhancements of the SMPS in comparison with the existing SCR power supply are discussed in detail in this paper. The features of the SMPS, along with experimental results for both power supplies, like efficiency, power losses and stability, are presented. Ongoing work is also discussed.