Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-D-BRD-05: Online Framework for Plan Tracking and Automatic Checks in Radiation Therapy

Purpose: To develop an online framework that tracks a patient’s plan from initial simulation to treatment and that helps automate elements of the physics plan checks usually performed in the record and verify (RV) system and treatment planning system. Methods: We have developed PlanTracker, an online plan tracking system that automatically imports new patients tasks and follows it through treatment planning, physics checks, therapy check, and chart rounds. A survey was designed to collect information about the amount of time spent by medical physicists in non-physics related tasks. We then assessed these non-physics tasks for automation. Using these surveys, we directed our PlanTracker software development towards the automation of intra-plan physics review. We then conducted a systematic evaluation of PlanTracker’s accuracy by generating test plans in the RV system software designed to mimic real plans, in order to test its efficacy in catching errors both real and theoretical. Results: PlanTracker has proven to be an effective improvement to the clinical workflow in a radiotherapy clinic. We present data indicating that roughly 1/3 of the physics plan check can be automated, and the workflow optimized, and show the functionality of PlanTracker. When the full system is in clinical use we will present data on improvement of time use in comparison to survey data prior to PlanTracker implementation. Conclusion: We have developed a framework for plan tracking and automatic checks in radiation therapy. We anticipate using PlanTracker as a basis for further development in clinical/research software. We hope that by eliminating the most simple and time consuming checks, medical physicists may be able to spend their time on plan quality and other physics tasks rather than in arithmetic and logic checks. We see this development as part of a broader initiative to advance the clinical/research informatics infrastructure surrounding the radiotherapy clinic. This research project has been financially supported by Varian Medical Systems, Palo Alto, CA, through a Varian MRA.

60 APPLIED LIFE SCIENCES↗

SU-E-J-68: Adaptive Radiotherapy of Head and Neck Cancer: Re-Planning Based On Prior Dose

Purpose: Adaptive Radiotherapy (ART) with frequent CT imaging has been used to improve dosimetric accuracy by accounting for anatomical variations, such as primary tumor shrinkage and/or body weight loss, in Head and Neck (H&N) patients. In most ART strategies, the difference between the planned and the delivered dose is estimated by generating new plans on repeated CT scans using dose-volume constraints used with the initial planning CT without considering already delivered dose. The aim of this study was to assess the dosimetric gains achieved by re-planning based on prior dose by comparing them to re-planning not based-on prior dose for H&N patients. Methods: Ten locally-advanced H&N cancer patients were selected for this study. For each patient, six weekly CT imaging were acquired during the course of radiotherapy. PTVs, parotids, cord, brainstem, and esophagus were contoured on both planning and six weekly CT images. ART with weekly re-plans were done by two strategies: 1) Generating a new optimized IMRT plan without including prior dose from previous fractions (NoPriorDose) and 2) Generating a new optimized IMRT plan based on the prior dose given from previous fractions (PriorDose). Deformable image registration was used to accumulate the dose distributions between planning and six weekly CT scans. The differences in accumulated doses for both strategies were evaluated using the DVH constraints for all structures. Results: On average, the differences in accumulated doses for PTV1, PTV2 and PTV3 for NoPriorDose and PriorDose strategies were <2%. The differences in Dmean to the cord and brainstem were within 3%. The esophagus Dmean was reduced by 2% using PriorDose. PriorDose strategy, however, reduced the left parotid D50 and Dmean by 15% and 14% respectively. Conclusion: This study demonstrated significant parotid sparing, potentially reducing xerostomia, by using ART with IMRT optimization based on prior dose for weekly re-planning of H&N cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-78: A Study of Dose Falloff Gradient in RapidArc Planning of Lung SBRT

Purpose: Rapid dose falloff beyond PTV is an important criterion for normal tissue sparing in SBRT. RTOG protocols use D2cm and R50% for plan quality evaluation. This study is aimed at analyzing the dose falloff gradient beyond the PTV extending into normal tissue structures and to ascertain the impact of PTV geometry and location on the dose falloff gradient in RapidArc planning of lung SBRT Methods: In this retrospective study, we analyzed 39 clinical RapidArc lung SBRT treatment plans that met RTOG-0915 criteria. Planning was done on Eclipse 8.9 for delivery on either Novalis NTx or TrueBeam STx equipped with HD MLCs. PTV volumes ranged between 5.3 and 113 cc (2.2 to 6 cm sphere equivalent diameter respectively) and their geographic locations were distributed in both lungs. 6X, 6X-FFF, 10X, and 10X-FFF energies were used for planning. All of these SBRT plans were planned using either 2 or 3 full or hemi arcs, with moderate couch kicks. Dose falloff gradients were obtained by generating 7 concentric 5 mm rings beyond PTV surface. Mean dose in each ring is used to evaluate percentage dose falloff gradient as a function of distance from the PTV surface. Results: The mean percentage dose falloff beyond PTV surface in all plans followed an exponential decay and the data was modeled with double exponential decay fit. Photon energy selection in the plan had a minimal impact on the mean percentage dose fall off beyond PTV surface. Conclusion: Dose falloff beyond PTV surface as a function of distance can be ascertained by the use of the double exponential decay fit coefficients in RapidArc planning of lung SBRT. This will help also in plan quality evaluation in addition to D2cm and R50% defined by RTOG.

60 APPLIED LIFE SCIENCES↗

SU-E-T-187: Collimation Methods in Spot Scanning Proton Therapy: A Treatment Plan Comparison Between a Fixed Aperture and a Dynamic Collimation System

Purpose: Low-energy treatments during spot scanning proton therapy (SSPT) suffer from poor conformity due to increased spot size. Collimation devices can reduce the lateral penumbra of a proton therapy dose distribution and improve the overall plan quality. The purpose of this work was to study the advantages of individual energy-layer collimation, which is unique to a recently proposed Dynamic Collimation System (DCS), in comparison to a standard, fixed aperture that allows only a single shape for all energy layers. Methods: Three brain patients previously planned and treated with SSPT were re-planned using an in-house treatment planning system capable of modeling collimated and un-collimated proton beamlets. The un-collimated plans, which served as a baseline for comparison, reproduced the target coverage of the clinically delivered plans. The collimator opening for the aperture based plans included a 0.6 cm expansion of the largest cross section of the target in the Beam’s Eye View, while the DCS based plans were created by optimizing the collimator position for beam spots near the periphery of the target in each energy layer. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring, averaged 9.13% and 3.48% for the DCS and aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 16.42% and 8.16% for the DCS and aperture plans, respectively. Conclusion: Collimation reduces the dose to normal tissue adjacent to the target and increases dose conformity to the target region for low-energy SSPT. The ability of the DCS to provide collimation to each energy layer yields better conformity in comparison to fixed aperture plans. This work was partially funded by IBA (Ion Beam Applications S.A.)

60 APPLIED LIFE SCIENCES↗

Technical Note: Dosimetric effects of couch position variability on treatment plan quality with an MRI-guided Co-60 radiation therapy machine

Purpose: Magnetic resonance imaging (MRI) guidance in radiation therapy brings real-time imaging and adaptive planning into the treatment vault where it can account for interfraction and intrafraction movement of soft tissue. The only commercially available MRI-guided radiation therapy device is a three-head {sup 60}Co and MRI system with an integrated treatment planning system (TPS). Couch attenuation of the beam of up to 20% is well modeled in the TPS. Variations in the patient’s day-to-day position introduce discrepancies in the actual couch attenuation as modeled in the treatment plan. For this reason, the authors’ institution avoids plans with beams that pass through or near the couch edges. This study investigates the effects of differential beam attenuation by the couch due to couch shifts in order to determine whether couch edge avoidance restrictions can be lifted. Couch shifts were simulated using a Monte Carlo treatment planning system and ion chamber measurements performed for validation. Methods: A total of 27 plans from 23 patients were investigated. Couch shifts of 1 and 2 cm were introduced in combinations of lateral and vertical directions to simulate patient position variations giving 16 shifted plans per reference plan. The 1 and 2 cm shifts were based on shifts recorded in 320 treatment fractions. Results: Following TG176 recommendations for measurement methods, couch attenuation measurements agreed with TPS modeled attenuation to within 2.1%. Planning target volume D95 changed less than 1% for 1 and 2 cm couch shifts in only the x-direction and less than 3% for all directions. Conclusions: Dosimetry of all plans tested was robust to couch shifts up to ±2 cm. In general, couch shifts resulted in clinically insignificant dosimetric deviations. It is conceivable that in certain cases with large systematic couch shifts and plans that are particularly sensitive to shifts, dosimetric changes might rise to a clinically significant level.

60 APPLIED LIFE SCIENCES↗

SU-C-202-02: A Comprehensive Evaluation of Adaptive Daily Planning for Cervical Cancer HDR Brachytherapy

Purpose: To evaluate adaptive daily planning for cervical cancer patients who underwent high-dose-rate intra-cavitary brachytherapy (HDR-ICBT). Methods: This study included 22 cervical cancer patients who underwent 5 fractions of HDR ICBT. Regions of interest (ROIs) including high-risk clinical tumor volume (HR-CTV) and organs-at-risk (OARs) were manually contoured on daily CT images. All patients were treated with adaptive daily plans, which involved ROI delineation and dose optimization at each treatment fraction. Single treatment plans were retrospectively generated by applying the first treatment fraction’s dwell times adjusted for decay and dwell positions of the applicator to subsequent treatment fractions. Various existing similarity metrics were calculated for the ROIs to quantify interfractional organ variations. A novel similarity score (JRARM) was established, which combined both volumetric overlap metrics (DSC, JSC, and RVD) and distance metrics (ASD, MSD, and RMSD). Linear regression was performed to determine a relationship between inter-fractional organ variations of various similarity metrics and D2cc variations from both plans. Wilcoxon Signed Rank Tests were used to assess adaptive daily plans and single plans by comparing EQD2 D2cc (α/β=3) for OARs. Results: For inter-fractional organ variations, the sigmoid demonstrated the greatest variations based on the JRARM and DSC similarity metrics. Comparisons between paired ROIs showed differences in JRARM scores and DSCs at each treatment fraction. RVD, MSD, and RMSD were found to be significantly correlated to D2cc variations for bladder and sigmoid. The comparison between plans found that adaptive daily planning provided lower EQD2 D2cc of OARs than single planning, specifically for the sigmoid (p=0.015). Conclusion: Substantial inter-fractional organ motion can occur during HDR-BT, which may significantly affect D2cc of OARs. Adaptive daily planning provides improved dose sparing for OARs compared to single planning.

60 APPLIED LIFE SCIENCES↗

SU-F-P-35: A Multi-Institutional Plan Quality Checking Tool Built On Oncospace: A Shared Radiation Oncology Database System

Purpose: Late toxicity from radiation to critical structures limits the possible dose in Radiation Therapy. Perfectly conformal treatment of a target is not realizable, so the clinician must accept a certain level of collateral radiation to nearby OARs. But how much? General guidelines exist for healthy tissue sparing which guide RT treatment planning, but are these guidelines good enough to create the optimal plan given the individualized patient anatomy? We propose a means to evaluate the planned dose level to an OAR using a multi-institutional data-store of previously treated patients, so a clinician might reconsider planning objectives. Methods: The tool is built on Oncospace, a federated data-store system, which consists of planning data import, web based analysis tools, and a database containing:1) DVHs: dose by percent volume delivered to each ROI for each patient previously treated and included in the database.2) Overlap Volume Histograms (OVHs): Anatomical measure defined as the percent volume of an ROI within a given distance to target structures.Clinicians know what OARs are important to spare. For any ROI, Oncospace knows for which patients’ anatomy that ROI was harder to plan in the past (the OVH is less). The planned dose should be close to the least dose of previous patients. The tool displays the dose those OARs were subjected to, and the clinician can make a determination about the planning objectives used.Multiple institutions contribute to the Oncospace Consortium, and their DVH and OVH data are combined and color coded in the output. Results: The Oncospace website provides a plan quality display tool which identifies harder to treat patients, and graphically displays the dose delivered to them for comparison with the proposed plan. Conclusion: The Oncospace Consortium manages a data-store of previously treated patients which can be used for quality checking new plans. Grant funding by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-T-100: Development and Implementation of a Treatment Planning Tracking System Into the Radiation Oncology Clinic

Purpose: With increasing numbers of cancer patients being diagnosed and the complexity of radiotherapy treatments rising it’s paramount that patient plan development continues to stay fluid within the clinic. In order to maintain a high standard of care and clinical efficiency the establishment of a tracking system for patient plan development allows healthcare providers to view real time plan progression and drive clinical workflow. In addition, it provides statistical datasets which can further identify inefficiencies within the clinic. Methods: An application was developed utilizing Microsoft’s ODBC SQL database engine to track patient plan status throughout the treatment planning process while also managing key factors pertaining to the patient’s treatment. Pertinent information is accessible to staff in many locations, including tracking monitors within dosimetry, the clinic network for both computers and handheld devices, and through email notifications. Plans are initiated with a CT and continually tracked through planning stages until final approval by staff. Patient’s status is dynamically updated by the physicians, dosimetrists, and medical physicists based on the stage of the patient’s plan. Results: Our application has been running over a six month period with all patients being processed through the system. Modifications have been made to allow for new features to be implemented along with additional tracking parameters. Based on in-house feedback, the application has been supportive in streamlining patient plans through the treatment planning process and data has been accumulating to further improve procedures within the clinic. Conclusion: Over time the clinic will continue to track data with this application. As data accumulates the clinic will be able to highlight inefficiencies within the workflow and adapt accordingly. We will add in new features to help support the treatment planning process in the future.

60 APPLIED LIFE SCIENCES↗

SU-F-T-277: Using Dose Weighted Mean Effective Depth to Improve Accuracy of Secondary MU Calculation for VMAT Plans

Purpose: In commercial secondary dose calculation system, an average effective depth is used to calculate the Monitor Units for an arc beam from the volumetric modulated arc (VMAT) plans. Typically, an arithmetic mean of the effective depths (AMED) of a VMAT arc beam is used, which may result in large MU discrepancy from that of the primary treatment planning system. This study is to demonstrate the use of a dose weighted mean effective depth (DWED) can improve accuracy of MU calculation for the secondary MU verification. Methods: In-house scripts were written in the primary treatment planning system (TPS) to first convert a VMAT arc beam to a series of static step & shoot beams (every 4 degree). The computed dose and effective depth of each static beam were then used to obtain the dose weighted mean effective depth (DWED) for the VMAT beam. The DWED was used for the secondary MU calculation for VMAT plans. Six lung SBRT VMAT plans, eight head and neck VMAT plans and ten prostate VMAT plans that had > 5% MU deviations (failed MU verification) using the AMED method were recalculated with the DWED. For comparison, same number VMAT plans that had < 5% MU deviations (passed MU verification) using AMED method were also reevaluated with the dose weighted mean effective depth method. Results: For MU verification passed plans, the mean and standard deviation of MU differences between the TPS and the secondary calculation program were 2.2%±1.5% for the AMED and 2.1%±1.7% for the DMED method. For the failed plans, the mean and standard deviation of MU differences of TPS to the secondary calculation program were 9.9%±4.7% and 4.7%±2.6, respectively. Conclusion: The dose weighted mean effective depth improved MU calculation accuracy which can be used for the pre-treatment MU verification of VMAT plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

60 APPLIED LIFE SCIENCES↗

SU-F-T-448: Use of Mixed Photon Energy Beam in Volumetric Modulated Arc Therapy (VMAT) Treatment Plan for Prostate Cancer

Purpose: To study the impact of different photon beam combination during VMAT planning and treatment delivery. Methods: Five prostate patients with no nodal involvement were chosen for the study and only prostate was considered as target (7920cGy/44fractions). In each case, three different VMAT plans were generated with two arcs (200°–160°&160°–200°). First plan used only 6MV in both arcs (6X-6X) and second utilized 6MV&15MV (6X-15X), whereas third one used 15MV&15MV (15X-15X). For consistency, all the plans were generated by the same planner using Monaco− treatment planning system (V5.1) for Elekta Synergy− linear accelerator with 1cm leaf-width. For plan comparison, target mean dose, conformity index (CI)=Planning target volume (PTV) covered by 95% of prescription dose/PTV were analyzed. Mean doses of bladder, rectum, left femur and right femur were analyzed. Integral dose (liter-Gray) to normal tissue (patient volume minus PTV), total monitor unit (MU) required to deliver a plan and gamma pass rate for each plan was analyzed. Results: The CI for PTV was 0.9937±0.0037, 0.9917±0.0033, and 0.9897±0.0048 for 6X-6X, 6X-15X and 15X-15X, respectively. Mean dose to target slightly increases with the decrease of energy. Mean doses to bladder were 3546.23±692.13cGy, 3487.43±715.53cGy and 3504.40±683.1cGy for 6X-6X, 6X-15X and 15X-15X, respectively. Mean doses to rectum were 4294.60±309.5cGy, 4277.07±279.93cGy and 4290.77±379.07cGy. Mean doses to left femur were 2737.13±545.93cGy, 2668.67±407.12cGy and 2416.77±300.73cGy and mean doses to the right femur were 2682.70±460.81cGy, 2722.58±541.92cGy and 2598.57±481.83cGy. Higher Integral doses to normal tissue observed for 6X-6X (163.06±24.6 Litre-Gray) followed by 6X-15X (154.35±24.74 Litre-Gray) and 15X-15X (145.84±26.03 Litre-Gray). Average MU required to deliver one fraction was 680.75±72.09, 634.81±95.07 and 605.06±114.65. Gamma pass rates were 99.83±0.21, 99.53±0.27 and 99.2±0.20. Conclusion: 6X-15X VMAT plan offer dosimetric advantage compared to 6X-6X in terms of lesser MU and integral dose without significant compromise in plan quality, where as in 15X-15X, neutron contamination risk is relatively higher.

60 APPLIED LIFE SCIENCES↗

SU-F-T-455: Is Contouring the Whole Breast Necessary for Two-Field 3D Breast Planning?

Purpose: To investigate the effect of contouring the whole breast on reducing the radiation dose to the heart and affected lung in tangential field-in-field 3D breast planning. We hypothesize that contouring the whole breast will simplify the plan normalization process, reduce dose to critical structures, while maintaining treatment plan quality and consistency. Methods: Twenty previously treated breast cancer patients using tangential field-in-field 3D planning technique were randomly selected. The affected breast was contoured following the RTOG breast atlas guideline. Breast PTV was created by shrinking 5 mm from the breast contour. The same plan has been pasted to the new contour and normalized to 95% of the Breast PTV receiving the prescribed isodose line. Lung V20 Gy% and Heart V25 Gy% were the primary study endpoints. Homogeneity Index (HI) and Conformity Index (CI) were calculated based on the following equations. HI= Dmax/ D95 and Nakamura’s Conformity Index= PIV/TVPIV × TV/TVPIV. Results: The average CI for previous plans was 1.68 vs. 1.66 for the new hybrid plan: both plans were conformal to the breast with similar quality. The HI for both the previous and the new hybrid plan was 1.24. Lung V 20% slightly increased from 4.27% to 4.82%. Heart V 25% for LT breast patients slightly decreased from 0.38% to 0.29%. Heart V 25% for RT breast patients was close to zero in both cases. Conclusion: With similar conformal and homogeneity indices for the plan quality, by contouring the whole breast following RTOG breast atlas guideline will simplify the planning process. The study showed that contouring the whole breast for patients with left-sided breast cancer reduced the heart V 25%, although not significantly, while maintaining the CI and HI. There was no measurable gain seen with whole breast contour for right-sided breast cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-01: A Simulation Study to Investigate Maximum Allowable Deformations of Implant Geometry Before Plan Objectives Are Violated in Prostate HDR Brachytherapy

Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan optimality than prostate volume changes.

60 APPLIED LIFE SCIENCES↗

Poster - 33: Dosimetry Comparison of Prone Breast Forward and Inverse Treatment planning considering daily setup variations

Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinF plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.

60 APPLIED LIFE SCIENCES↗

State Performance-Based Regulation Using Multiyear Rate Plans for U.S. Electric Utilities

Electric utilities today must contain costs at a time when many need to modernize aging systems and all face major changes in technologies, customer preferences and competitive pressures.Most U.S. electric utility facilities are investor-owned, subject to rate and service regulation by state public utility commissions. Regulatory systems under which these utilities operate affect their performance and ability to meet these challenges. In this business environment, multiyear rate plans have some advantages over traditional rate regulation.The report focuses on key design issues and provides case studies of the multiyear rate plan approach, applicable to both vertically integrated and restructured states. Mark Newton Lowry and Matt Makos of Pacific Energy Group Research and Jeff Deason of Berkeley Lab authored the report; Lisa Schwartz, Berkeley Lab, was project manager and technical editor.The report is aimed primarily at state utility regulators and stakeholders in the state regulatory process. The multiyear rate approach also provides ideas on how to streamline oversight of public power utilities and rural electric cooperatives for their governing boards.Two key provisions of multiyear rate plans strengthen cost containment incentives and streamline regulation: 1. Reducing frequency of rate cases, typically to every four or five years 2. Using an attrition relief mechanism to escalate rates or revenue between rate cases to address cost pressures such as inflation and growth in number of customers, independently of the utility’s own cost Better utility performance can be achieved under well-designed multiyear rate plans while achieving lower regulatory costs. Benefits can be shared between utilities and their customers. But plans can be complex and involve significant changes in the regulatory system. Designing plans that stimulate utility performance without undue risk and share benefits fairly can be challenging.This report discusses the rationale for multiyear rate plans and their usefulness under modern business conditions. It then explains critical plan design issues and challenges and presents results from numerical research that considers the extra incentive power achieved under different plan provisions. Next, the report presents several case studies of utilities that have operated under formal multiyear rate plans or, for various reasons, have stayed out of rate cases for more than a decade. These studies consider the effect of multiyear rate plans and rate case frequency on utility cost, reliability and other performance dimensions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Plan for the Disposal of Existing and Future TRU Wastes - 18616

Now that the Waste Isolation Pilot Plant (WIPP) has re-opened, after being down for three years due to an accident the DOE National TRU Program has re-developed a plan for the disposal of existing and future TRU wastes. The National TRU Waste Management Plan (NTWMP) is an integrated plan to address the needs of DOE sites across the DOE Weapons Complex that create and store TRU waste, and is centered on the capability of WIPP to receive and dispose of TRU waste. The WIPP capability is planned as a weekly shipping rate and is defined by emplacement and receipt rate capabilities since WIPP is not permitted for long-term storage. And, shipping rates may be constrained by new WIPP Waste Acceptance Criteria (WAC) and future plans for repository configurations and disposal package capabilities over the next 30 years. Since WIPP is the only disposal system available to the DOE for TRU waste disposal, DOE has a newly projected life-cycle need for WIPP to remain open and available up to 2050. It is projected that the need for WIPP will continue up to the year 2050 for the disposition of the remaining legacy TRU inventories and for the disposal of TRU waste continuing to be generated at DOE's National Laboratories. In addition, there are several other potential new waste streams in which WIPP is being considered an alternative solution for their disposition. The NTWMP has been updated to reflect the short-term and long-term plans for TRU waste disposal at WIPP. The short-term plan is used by DOE for budget projection and integration purposes to facilitate and inform budget planning, both in DOE's Environmental Management (EM) and National Nuclear Security Administration (NNSA) organizations. Most legacy TRU waste (generated in the past and stored at DOE sites today) is owned and managed by EM. And, EM submits integrated budget requests for DOE sites, including the integration of resources for TRU waste management. NNSA and DOE's Office of Science (OS) funds TRU waste management as part of their mission funding and NNSA should eventually be the primary user of the WIPP resources as EM's legacy TRU waste is cleaned-up. Prior to the unexpected shutdown of WIPP in 2014, there was a small back-log of waste certified for WIPP disposal and shipments of TRU waste to WIPP were 'just-in-time' as waste was certified. After three years of WIPP being down, DOE sites have built significant back-logs of TRU waste to be certified for WIPP. That back-log built up to over 25,000 containers of TRU waste during that three-year period (Table 1). The backlog included both Contact-Handled (CH) TRU waste and Remote-Handled (RH) TRU waste, and even though WIPP re-opened in April of 2017, it is only open for TRU waste containers that can be stacked on disposal room floors. Plans for changing RH waste disposal packages and methods are in-the-works, but are not yet mature enough for significant planning. In addition, the WIPP underground facilities are now partially contaminated with radioactive particulate, which significantly reduces the WIPP operational efficiencies as compared to 2014. With a large back-log of waste ready for WIPP disposal and limited throughput for WIPP disposal rates, the focus of the NTWMP is to prioritize the selection of TRU wastes from the various sites based on WIPP waste emplacement rates and shipping rates to WIPP. Some TRU waste sites have a significant need to be top priority for shipments to WIPP, and that must be balanced with the need for all TRU waste sites to have some shipments to deplete their back-log of TRU wastes. Storage and management of TRU waste is very costly for DOE and many of those resources could be used to optimize the overall disposition of TRU waste and save DOE significant funding. In addition, the plan will show the possible transition of TRU Waste Management from primarily being an EM function to being an NNSA function in the coming years. As legacy TRU waste inventories are removed, and as NNSA mission-related TRU waste inventories are produced, DOE will be faced with deciding where the primary responsibility for TRU waste management should reside. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating equity in transportation scenario planning: A systematic review

To address the growing uncertainties in the future transportation industry, planners and engineers have identified and implemented scenario planning, a multi-step and strategic approach, in long-range transportation planning. A comprehensive examination of how equity is envisioned, planned, and analyzed during this process remains absent, despite several key guidelines of scenario planning exercises. This paper conducts a systematic literature review focusing on how equity has been considered and evaluated in scenario planning. The resources include academic papers, agency reports, and materials from the recent scenario planning conference, the 2nd Conference on Scenario Planning in Transportation hosted by the Transportation Research Board. This paper examines equity in scenario planning in three important ways: 1) the ways equity has been integrated across steps; 2) how equity analysis has evolved; and 3) when it is necessary to consider equity. This work adds value to the existing body of knowledge by presenting the policy implications based on the review of the current scenario planning research and practices. Early policy recommendations include the need for more vertical equity evaluations, the construction of robustness and justice indicators, and the adoption of a flexible mindset of planning for rather than being fixated on a single scenario.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗