Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification

Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee with intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a fixed iodine concentration of 5 mg/ml and reconstructions maximizing overall accuracy across the range of insert diameters, the minimum diameter classified with accuracy >80% was ∼15 mm for FBP and PLQ and ∼10 mm for PLTV, improving to ∼7 mm for FBP and PLQ and ∼3 mm for PLTV at 15.6 mGy. The results indicate similar performance for FBP and PLQ and showed improved classification accuracy with edge-preserving PLTV. A slight preference for increased smoothing of the HE data was found. DE CBCT discrimination of iodine and bone in the knee was demonstrated with FBP and PLTV at 6.2 mGy total dose. Conclusions: For iodine concentrations >5 mg/ml and detail size ∼20 mm, material classification accuracy of >90% was achieved in DE CBCT with both FBP and PL at total doses <10 mGy. Optimal performance was attained by selection of reconstruction parameters based on the differences in noise between HE and LE data, typically favoring stronger smoothing of the HE data, and by using penalties matched to the imaging task (e.g., edge-preserving PLTV in areas of uniform enhancement)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robust measurement of microbial reduction of graphene oxide nanoparticles using image analysis

ABSTRACT Shewanella oneidensis ( S. oneidensis ) has the capacity to reduce electron acceptors within a medium and is thus used frequently in microbial fuel generation, pollutant breakdown, and nanoparticle fabrication. Microbial fuel setups, however, often require costly or labor-intensive components, thus making optimization of their performance onerous. For rapid optimization of setup conditions, a model reduction assay can be employed to allow simultaneous, large-scale experiments at lower cost and effort. Since S. oneidensis uses different extracellular electron transfer pathways depending on the electron acceptor, it is essential to use a reduction assay that mirrors the pathways employed in the microbial fuel system. For microbial fuel setups that use nanoparticles to stimulate electron transfer, reduction of graphene oxide provides a more accurate model than other commonly used assays as it is a bulk material that forms flocculates in solutions with a large ionic component. However, graphene oxide flocculates can interfere with traditional absorbance-based measurement techniques. This study introduces a novel image analysis method for quantifying graphene oxide reduction, showing improved performance and statistical accuracy over traditional methods. A comparative analysis shows that the image analysis method produces smaller errors between replicates and reveals more statistically significant differences between samples than traditional plate reader measurements under conditions causing graphene oxide flocculation. Image analysis can also detect reduction activity at earlier time points due to its use of larger solution volumes, enhancing color detection. These improvements in accuracy make image analysis a promising method for optimizing microbial fuel cells that use nanoparticles or bulk substrates. IMPORTANCE Shewanella oneidensis ( S. oneidensis ) is widely used in reduction processes such as microbial fuel generation due to its capacity to reduce electron acceptors. Often, these setups are labor-intensive to operate and require days to produce results, so use of a model assay would reduce the time and expenses needed for optimization. Our research developed a novel digital analysis method for analysis of graphene oxide flocculates that may be utilized as a model assay for reduction platforms featuring nanoparticles. Use of this model reduction assay will enable rapid optimization and drive improvements in the microbial fuel generation sector.

Bennett, Danielle T. (ORCID:0009000188748827)↗

How to Estimate Attitude from Vector Observations

The most robust estimators minimizing Wahba's loss function are Davenport's q method and the Singular Value Decomposition (SVD) method. The q method is faster than the SVD method with three or more measurements. The other algorithms are less robust since they solve the characteristic polynomial equation to find the maximum eigenvalue of Davenport's K matrix. They are only preferable when speed or processor power is an important consideration. Of these, Fast Optimal Attitude Matrix (FOAM) is the most robust and faster than the q method. Robustness is only an issue for measurements with widely differing accuracies, so the fastest algorithms, Quaternion ESTimator (QUEST), EStimator of the Optimal Quaternion (ESOQ), and ESOQ2, are well suited to star sensor applications.

Markley, F. Landis↗

Double-pulse and single-pulse laser-induced breakdown spectroscopy for distinguishing between gaseous and particulate phase analytes

We explore the use of a combination of double-pulse and single-pulse laser-induced breakdown spectroscopy (LIBS) methodologies as a means of differentiating between solid-phase and gaseous-phase analytes (namely, carbon) in an aerosol stream. A range of spectral data was recorded for double-pulse and single-pulse configurations, including both ns and fs prepulse widths, while varying the gas-phase mass percentage of the carbon from about 10% to 90% for various fixed carbon concentrations. The carbon emission response, as measured by the peak-to-continuum ratio, was greater for the double-pulse configuration as compared with the single-pulse response and was also enhanced as the percentage of solid-phase carbon was increased. Using a combination of the double-pulse and single-pulse emission signals, a monotonically increasing response function was found to correlate with the percentage of gas-phase analyte. However, individual data points at the measured gas-phase percentages reveal considerable scatter from the predicted trend. Furthermore, the double-pulse to single-pulse ratio was only pronounced with the ns-ns configuration as compared with the fs-ns scheme. Overall, the LIBS methodology has been demonstrated as a potential means to discriminate between gas-phase and particulate-phase fractions of the same elemental species in an aerosol, although future optimization of the temporal parameters should be explored to improve the precision and accuracy of this approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy

Background: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). Methods: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. Results: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC–SC–RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC–RC. Conclusions: Our results suggest that studies reconstructed by OS-EM with AC–SC–RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-layer Potfit: An accurate potential representation for efficient high-dimensional quantum dynamics

The multi-layer multi-configuration time-dependent Hartree method (ML-MCTDH) is a highly efficient scheme for studying the dynamics of high-dimensional quantum systems. Its use is greatly facilitated if the Hamiltonian of the system possesses a particular structure through which the multi-dimensional matrix elements can be computed efficiently. In the field of quantum molecular dynamics, the effective interaction between the atoms is often described by potential energy surfaces (PES), and it is necessary to fit such PES into the desired structure. For high-dimensional systems, the current approaches for this fitting process either lead to fits that are too large to be practical, or their accuracy is difficult to predict and control. This article introduces multi-layer Potfit (MLPF), a novel fitting scheme that results in a PES representation in the hierarchical tensor (HT) format. The scheme is based on the hierarchical singular value decomposition, which can yield a near-optimal fit and give strict bounds for the obtained accuracy. Here, a recursive scheme for using the HT-format PES within ML-MCTDH is derived, and theoretical estimates as well as a computational example show that the use of MLPF can reduce the numerical effort for ML-MCTDH by orders of magnitude, compared to the traditionally used POTFIT representation of the PES. Moreover, it is shown that MLPF is especially beneficial for high-accuracy PES representations, and it turns out that MLPF leads to computational savings already for comparatively small systems with just four modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selecting registration schemes in case of interstitial lung disease follow-up in CT

Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985–2.156 mm and 1.966–2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. Conclusions: Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.

60 APPLIED LIFE SCIENCES↗

Mathematical methods for optimal polynomial recovery of high-dimensional systems from noisy data

The goal of our Early Career Research Project (ECRP) is to establish a modern mathematical foundation that will enable next-generation computational methods for polynomial approximation of high-dimensional systems, having a certain set of constraints, from a limited amount of noisy data. Such a foundation is critical to realizing the future potential of the DOE user facilities, and will ultimately empower scientists to address a fundamental question, namely, “how many realizations of a nonlinear manifold are required to recover the entire high-dimensional solution map, with optimal approximation guarantees and minimal computational cost?” The central theme of this effort aims to conquer this challenge by pioneering the development of extraordinarily innovative theoretical analysis and transformational non-intrusive computational methodologies. Such approaches will enable the reconstruction of the entire high-dimensional solution map, with accuracy comparable to the best approximation, while utilizing an optimal number of samples. During this reporting period we have made significant progress on four thrusts.

97 MATHEMATICS AND COMPUTING↗

Metabolite discovery through global annotation of untargeted metabolomics data

Liquid chromatography–high-resolution mass spectrometry (LC-MS)-based metabolomics aims to identify and quantify all metabolites, but most LC-MS peaks remain unidentified. Here we present a global network optimization approach, NetID, to annotate untargeted LC-MS metabolomics data. The approach aims to generate, for all experimentally observed ion peaks, annotations that match the measured masses, retention times and (when available) tandem mass spectrometry fragmentation patterns. Peaks are connected based on mass differences reflecting adduction, fragmentation, isotopes, or feasible biochemical transformations. Global optimization generates a single network linking most observed ion peaks, enhances peak assignment accuracy, and produces chemically informative peak–peak relationships, including for peaks lacking tandem mass spectrometry spectra. Applying this approach to yeast and mouse data, we identified five previously unrecognized metabolites (thiamine derivatives and N-glucosyl-taurine). Isotope tracer studies indicate active flux through these metabolites. Furthermore, NetID applies existing metabolomic knowledge and global optimization to substantially improve annotation coverage and accuracy in untargeted metabolomics datasets, facilitating metabolite discovery.

59 BASIC BIOLOGICAL SCIENCES↗

TULIP: An RNA-seq-based Primary Tumor Type Prediction Tool Using Convolutional Neural Networks

Background: With cancer as one of the leading causes of death worldwide, accurate primary tumor type prediction is critical in identifying genetic factors that can inhibit or slow tumor progression. There have been efforts to categorize primary tumor types with gene expression data using machine learning, and more recently with deep learning, in the last several years. Methods In this paper, we developed four 1-dimensional (1D) Convolutional Neural Network (CNN) models to classify RNA-seq count data as one of 17 highly represented primary tumor types or 32 primary tumor types regardless of imbalanced representation. Additionally, we adapted the models to take as input either all Ensembl genes (60,483) or protein coding genes only (19,758). Unlike previous work, we avoided selection bias by not filtering genes based on expression values. RNA-seq count data expressed as FPKM-UQ of 9,025 and 10,940 samples from The Cancer Genome Atlas (TCGA) were downloaded from the Genomic Data Commons (GDC) corresponding to 17 and 32 primary tumor types respectively for training and validating the models. Results: All 4 1D-CNN models had an overall accuracy of 94.7% to 97.6% on the test dataset. Further evaluation indicates that the models with protein coding genes only as features performed with better accuracy compared to the models with all Ensembl genes for both 17 and 32 primary tumor types. For all models, the accuracy by primary tumor type was above 80% for most primary tumor types. Conclusions: We packaged all 4 models as a Python-based deep learning classification tool called TULIP (TUmor CLassIfication Predictor) for performing quality control on primary tumor samples and characterizing cancer samples of unknown tumor type. Further optimization of the models is needed to improve the accuracy of certain primary tumor types.

Jones, Sara↗

Modeling Stationary Lithium-Ion Batteries for Optimization and Predictive Control

Accurately modeling stationary battery storage behavior is crucial to understand and predict its limitations in demand-side management scenarios. In this paper, a lithium-ion battery model was derived to estimate lifetime and state-of-charge for building-integrated use cases. The proposed battery model aims to balance speed and accuracy when modeling battery behavior for real-time predictive control and optimization. In order to achieve these goals, a mixed modeling approach was taken, which incorporates regression fits to experimental data and an equivalent circuit to model battery behavior. A comparison of the proposed battery model output to actual data from the manufacturer validates the modeling approach taken in the paper. Additionally, a dynamic test case demonstrates the effects of using regression models to represent internal resistance and capacity fading.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Toward Verification of the γ-Reθt Transition Model in OVERFLOW and FUN3D

The results of an ongoing assessment of the transition modeling capability in NASA's OVERFLOW and FUN3D programs are presented, with a focus on the Langtry-Menter γ-Reθt transition model in combination with the shear-stress transport (SST) turbulence model. While the effect of numerics and boundary conditions on the accuracy and iterative convergence of RANS solutions for fully turbulent flows has been well documented, especially in the context of canonical flow configurations, the same cannot be said for transport-equation-based transition models coupled with RANS-based turbulence models. Given the criticality of transition modeling for new aircraft design and optimization, there has been a renewed focus on the accuracy of such transition models and their inconsistent implementation across different flow solvers as seen from the AIAA and NATO-AVT workshops. In this work, we aim to establish the verification of such models via these two well established CFD codes with different numerics. The goal is to produce high-quality data, such as grids, solutions, and other auxiliary data, that may be utilized for code verification by others in the CFD community. As a first step, the work reported here is focused on the Langtry-Menter transition model as applied to two simple 2D configurations, namely the flat plate, and the NLF-0416, respectively. The paper also highlights how the boundary conditions and baseline turbulence model can affect the solutions from the SST-based Langtry-Menter transition model. A preliminary evaluation of the automatic mesh adaption capabilities of these solvers and potential benefits for flow configurations involving a mix of laminar, transitional, and fully turbulent flows is also reported.

CFD Modeling↗

Efficient derivative computation for unsteady fatigue-constrained nonlinear aero-structural wind turbine blade optimization

Gradient-based optimization offers significant efficiency advantages for wind turbine blade design, but its application has often been limited by the cost and accuracy of finite-difference derivative calculations, especially when fatigue constraints are considered. In this work, we systematically compare and evaluate four differentiation techniques, namely algorithmic differentiation, implicit differentiation, sparsity exploitation, and parallelization, to determine their effectiveness in computing accurate gradients through time-domain aero-structural simulations. By integrating these techniques with unsteady nonlinear aerodynamic and structural models, we develop software designed for accurate gradient computation. We show that combining these techniques addresses memory and runtime challenges associated with long simulations required by design load cases. Specifically, the most effective combination reduces derivative computation wall time by over an order of magnitude compared to finite differencing while maintaining superior accuracy. We demonstrate this approach in a proof-of-concept aero-structural optimization of a wind turbine blade that improves the cost of energy by 12.78 %. This comparative study establishes a viable approach for fatigue-aware blade design that balances computational efficiency with modeling accuracy.

17 WIND ENERGY↗

An a priori evaluation of a principal component and artificial neural network based combustion model in diesel engine conditions

A principal component analysis (PCA) and artificial neural network (ANN) based chemistry tabulation approach is presented. ANNs are used to map the thermochemical state onto a low-dimensional manifold consisting of five control variables that have been identified using PCA. Three canonical configurations are considered to train the PCA-ANN model: a series of homogeneous reactors, a nonpremixed flamelet, and a two-dimensional lifted flame. The performance of the model in predicting the thermochemical manifold of a spatially-developing turbulent jet flame in diesel engine thermochemical conditions is a priori evaluated using direct numerical simulation (DNS) data. The PCA-ANN approach is compared with a conventional tabulation approach (tabulation using ad hoc defined control variables and linear interpolation). The PCA-ANN model provides higher accuracy and requires several orders of magnitude less memory. Here, these observations indicate that the PCA-ANN model is superior for chemistry tabulation, especially for modelling complex chemistries that present multiple combustion modes as observed in diesel combustion. The performance of the PCA-ANN model is then compared to the optimal estimator, i.e. the conditional mean from the DNS. The results indicate that the PCA-ANN model gives high prediction accuracy, comparable to the optimal estimator, especially for major species and the thermophysical properties. Higher errors are observed for the minor species and reaction rate predictions when compared to the optimal estimator. It is shown that the prediction of minor species and reaction rates can be improved by using training data that exhibits a variation of parameters as observed in the turbulent flame. The output of the ANN is analysed to assess mass conservation. It is observed that the ANN incurs a mean absolute error of 0.05% in mass conservation. Furthermore, it is demonstrated that this error can be reduced by modifying the cost function of the ANN to penalise for deviation from mass conservation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convolutional Neural Networks for Hydrometeor Classification using Dual Polarization Doppler Radars

Traditional fuzzy logic hydrometeor classification algorithm is a common way to classify precipitation type from dual polarization doppler radar. We propose a deep learning-based method to estimate hydrometeors efficiently using observed radar variables such as horizontal reflectivity (Z H ), differential reflectivity (Z DR ), correlation coefficient (ρ HV ) and specific differential phase (K DP ) from National Weather Service NEXRAD collected at Vance AFB facility at the first elevation angle from January 1st, 2015 to July 31th, 2019. We stack matrices of values from these four polarimetric variables as one 3D array. Samples are preprocessed and divided into training, validation and test set with four target hydrometeor categories (Ice Crystals (IC), Dry Snow (DS), Light and/or Moderate Rain (RA) and Big Drops (rain) (BD)). We developed and optimized five Convolutional Neural Networks (CNNs) architectures and achieved an accuracy of 87.23% and 93.736% respectively using modified ResNet with two different input data selection strategies for hydrometeor classification. Training data selection strategies were important to ensure use of available samples in training for robust performance evaluated by applying the models to novel time period beyond what was use to train the model. Seasonal variation in atmospheric conditions lead to seasonal patterns of liquid vs solid forms of precipitation, that poses challenge for classifier and offer insights into domain specific approaches required for problem of hydrometeor identification. Computationally efficient and scalable approach for classification of hydrometeors offer opportunties to effectively use the large volumes of rich time series of radar observations that are becoming increasingly available.

Lu, Yuping↗

Screened Range-Separated Hybrid Functional with Polarizable Continuum Model Overcomes Challenges in Describing Triplet Excitations in the Condensed Phase Using TDDFT

Long range-corrected (LRC) or range-separated hybrid (RSH) functionals where the long-range (LR) limit of electronic interactions is set to the exact exchange have been shown to correct the tendency of traditional density functional theory (DFT) to underestimate the frontier orbital gap. Consequently, the use of such functionals in calculating electronic excited states using linear response based time-dependent DFT (TDDFT) has been successful in correcting the tendency for underestimating the energies of charge transfer states by DFT-based calculations. More recently formulations of functionals that attenuate the LR limit to address condensed-phase effects to polarize the electronic density have been reported. In particular screened RSH (SRSH) combined with polarizable continuum model (PCM) was benchmarked successfully in reproducing the fundamental gap and charge transfer state energies of molecular systems in the condensed phase. Here we use SRSH-PCM to address triplet excited states, and show its success in obtaining correspondence of the low-lying triplet states to the singlet–triplet gap in a similar way that the fundamental orbital gap corresponds to electron removal and addition energies. Importantly, the accuracy of the SRSH-PCM in calculating triplet excitations stands on the polarization consistent framework in addressing the scalar dielectric constant and without affecting the optimal tuning by triplet energies. Finally, the prospect of even further improving the SRSH-PCM accuracy in calculating triplet states can be achieved by optimal tuning on the basis of the spin multiplicity gap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗