Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

EVOLUTION OF THE RADIO-X-RAY COUPLING THROUGHOUT AN ENTIRE OUTBURST OF AQUILA X-1

The 2009 November outburst of the neutron star X-ray binary Aquila X-1 (Aql X-1) was observed with unprecedented radio coverage and simultaneous pointed X-ray observations, tracing the radio emission around the full X-ray hysteresis loop of the outburst for the first time. We use these data to discuss the disk-jet coupling, finding the radio emission to be consistent with being triggered at state transitions, both from the hard to the soft spectral state and vice versa. Our data appear to confirm previous suggestions of radio quenching in the soft state above a threshold X-ray luminosity of {approx}10% of the Eddington luminosity. We also present the first detections of Aql X-1 with very long baseline interferometry, showing that any extended emission is relatively diffuse and consistent with steady jets rather than arising from discrete, compact knots. In all cases where multi-frequency data were available, the source radio spectrum is consistent with being flat or slightly inverted, suggesting that the internal shock mechanism that is believed to produce optically thin transient radio ejecta in black hole X-ray binaries is not active in Aql X-1.

79 ASTRONOMY AND ASTROPHYSICS↗

Parallel multiplex laser feedback interferometry

We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy absolute distance measurement using frequency comb referenced multiwavelength source

We propose a new approach to multiple-wavelength interferometry, targeted to high bandwidth absolute distance measurement, with nanometer accuracy over long distances. Two cw lasers are stabilized over a wide range of frequency intervals defined by an optical frequency comb, thus offering an unprecedented large choice of synthetic wavelengths. By applying a superheterodyne detection technique, we demonstrated experimentally an accuracy of 8 nm over 800 mm for target velocities up to 50 mm/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atom Interferometry in the Presence of an External Test Mass

The influence of an external test mass on the phase of the signal of an atom interferometer is studied theoretically. Using traditional techniques in atom optics based on the density matrix equations in the Wigner representation, we are able to extract the various contributions to the phase of the signal associated with the classical motion of the atoms, the quantum correction to this motion resulting from atomic recoil that is produced when the atoms interact with Raman field pulses and quantum corrections to the atomic motion that occur in the time between the Raman field pulses. Thus, by increasing the effective wave vector associated with the Raman field pulses using modified field parameters, we can increase the sensitivity of the signal to the point where such quantum corrections can be measured. Furthermore, the expressions that are derived can be evaluated numerically to isolate the contribution to the signal from an external test mass. The regions of validity of the exact and approximate expressions are determined.

42 ENGINEERING↗

X-ray scattering measurements of dissociation-induced metallization of dynamically compressed deuterium

Hydrogen, the simplest element in the universe, has a surprisingly complex phase diagram. Because of applications to planetary science, inertial confinement fusion and fundamental physics, its high-pressure properties have been the subject of intense study over the past two decades. While sophisticated static experiments have probed hydrogen’s structure at ever higher pressures, studies examining the higher-temperature regime using dynamic compression have mostly been limited to optical measurement techniques. Here we present spectrally resolved x-ray scattering measurements from plasmons in dynamically compressed deuterium. Combined with Compton scattering, and velocity interferometry to determine shock pressure and mass density, this allows us to extract ionization state as a function of compression. Finally, the onset of ionization occurs close in pressure to where density functional theory-molecular dynamics (DFT-MD) simulations show molecular dissociation, suggesting hydrogen transitions from a molecular and insulating fluid to a conducting state without passing through an intermediate atomic phase.

36 MATERIALS SCIENCE↗

The Disk Physical Conditions of 48 Persei Constrained by Contemporaneous Hα Spectroscopy and Interferometry

We utilize a multi-step modeling process to produce synthetic interferometric and spectroscopic observables, which are then compared to their observed counterparts. Our extensive set of interferometric observations of the Be star 48 Per, totaling 291 data points, were obtained at the Navy Precision Optical Interferometer from 2006 November 07 to 23. Our models were further constrained by comparison with contemporaneous Hα line spectroscopy obtained at the John S. Hall Telescope at the Lowell Observatory on 2006 November 1. Theoretical spectral energy distributions, SEDs, for 48 Per were confirmed by comparison with observations over a wavelength regime of 0.4–60 μm from Touhami et al. and Vieira et al. Our best-fitting combined model from Hα spectroscopy, Hα interferometry, and SED fitting has a power-law density fall off, n, of 2.3 and an initial density at the stellar surface of ρ{sub 0}=1.0×10{sup −11} g cm{sup −3} with an inclination constrained by Hα spectroscopy and interferometry of 45{sup ∘}±5{sup ∘}. The position angle for the system, measured east from north, is 114° ± 18°. Our best-fit model shows that the disk emission originates in a moderately large disk with a radius of 25 R {sub *}, which is consistent with a disk mass of approximately 5 × 10{sup 24} g or 3 × 10{sup −10} M {sub *}. Finally, we compare our results with previous studies of 48 Per by Quirrenbach et al. and find agreement, whereas our disk size does not agree with Delaa et al., based on a much smaller visibility set.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma Interactions in Laser Irradiated Semi-Cylindrical Cavities Studied with Soft X-Ray Interferometry Using a Capillary Discharge Laser

Soft x-ray interferometry was used to measure the evolution of dense converging plasmas created by laser irradiation of 500 {micro}m diameter semi-cylindrical carbon targets. Optical laser pulses with an intensity of {approx} 1 x 10{sup 12} W cm{sup -2} and 120 ps duration were used to heat the surface of the cavities. The dense plasma formed expands from the walls converging slightly off the semi-cylinder's axis, giving rise to a bright localized high density plasma region. A sequence of electron density maps were measured using a 46.9 nm wavelength tabletop capillary discharge soft x-ray laser probe and a amplitude division interferometer based on diffraction gratings. The measured density profiles are compared with simulations conducted using the multi-dimensional hydrodynamic code HYDRA. The benchmarked model was then used to simulate particle trajectories which reveal that the increase in electron density near the axis is mainly the result of the convergence of plasma that originated at the bottom of the groove during laser irradiation.

42 ENGINEERING↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Early time studies of cylindrical liner implosions at 1 MA on COBRA

Tests of the magnetized liner inertial fusion (MagLIF) concept will make use of the 27 MA Z machine at Sandia National Laboratories, Albuquerque, to implode a cylindrical metal liner to compress and heat preheated, magnetized plasma contained within it. While most pulsed power machines produce much lower currents than the Z-machine, there are issues that can still be addressed on smaller scale facilities. Recent work on the Cornell Beam Research Accelerator (COBRA) has made use of 10 mm long and 4 mm diameter metal liners having different wall thicknesses to study the initiation of plasma on the liner’s surface as well as axial magnetic field compression [P.-A. Gourdain et al., Nucl. Fusion 53, 083006 (2013)]. This report presents experimental results with non-imploding liners, investigating the impact the liner’s surface structure has on initiation and ablation. Extreme ultraviolet (XUV) imaging and optical 12 frame camera imaging were used to observe and assess emission non-uniformities as they developed. Axial and side-on interferometry was used to determine the distribution of plasma near the liner surface, including the impact of non-uniformities during the plasma initiation and ablation phases of the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monolithic Spatial Heterodyne Raman Spectrometers (mSHRS): Toward highly miniature chemical sensors for deployment on moving platforms (Final Report, Phase I)

This report covers phase 1 (year 1) of the mSHRS project. Our ultimate long-term goal is to develop highly miniature Raman analyzers, known as spatial heterodyne Raman spectrometers (SHRS), that are deployable as in-situ chemical sensors on moving platforms. During Phase I (FY19/20) funding, our team focused our efforts solely on the key innovation needed toward realizing that goal: the development of the monolithic interferometer comprising the beam splitter and gratings with the appropriate design parameters and tolerances to enable Raman interferometry. We successfully developed and characterized the performance of the first monolithic SHRS devices including a monolithic version that incorporates field-widened optics. Our solid-state design approach integrated all optical components as a single monolithic unit for maintaining precise optical alignment during sensor operation, a requirement for operating in a vibration prone environment. This project has two principle activities: (1) Design and fabricate monolithic SHRS devices (i.e. monolithic device task) and (2) characterize the mSHRS devices in terms of performance (i.e. the Monolithic SHRS characterization task).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor point defect concentration profiles measured using coherent acoustic phonon waves

Coherent acoustic phonon interferometry is used to quantitatively measure depth-dependent point defect concentrations in semiconductor systems with a depth range of the order of tens of microns. Using time-resolved pump-probe techniques, the optical response of ion-beam irradiated GaAs crystals is analyzed as a function of defect concentration ranging over four orders of magnitude. Varying the ion dose quantitatively relates changes in the optical response to local defect concentrations. Thermal annealing is shown to reduce the effect on the optical response, indicating recovery of the crystal lattice through self-interstitial-vacancy recombination.

36 MATERIALS SCIENCE↗

Assessment of the grindability of robocast silicon carbide

The demand for high-performance lightweight optics has driven interest in silicon carbide (SiC) due to its exceptional thermal stability, hardness, and strength-to-weight ratio. This study investigates the potential of robocasting, an additive manufacturing process, as a viable method for producing lightweighted SiC components for optical applications. Four samples with varied starting powder phases (α and β) and sintering conditions were fabricated and evaluated. Post-sintering surface and form were assessed using coherence scanning interferometry (CSI) and coordinate measuring machine (CMM) techniques. A three-stage grinding process was applied to each sample, with surface roughness assessed at each stage. Results demonstrate that samples with predominantly α-phase SiC and smaller particle sizes achieved superior surface finish, particularly sample D2-α-2135 °C, which displayed the lowest post-grinding Sq value of 0.178 µm. The analysis also indicated no significant print-through effect from the lightweighting structure, or print artifacts, at this stage of grinding. However, β-phase samples showed poorer grindability, increased surface roughness, and pitting. These findings suggest that phase composition and particle size are critical for achieving the desired surface quality in robocast SiC optics. Future work will incorporate additional samples and finer grinding wheels to refine surface quality further, supporting the development of SiC for high-precision optical applications.

Barrett, Taylor [ORNL]↗

Atom chip apparatus for experiments with ultracold rubidium and potassium gases

We present a dual chamber atom chip apparatus for generating ultracold {sup 87}Rb and {sup 39}K atomic gases. The apparatus produces quasi-pure Bose-Einstein condensates of 10{sup 4} {sup 87}Rb atoms in an atom chip trap that features a dimple and good optical access. We have also demonstrated production of ultracold {sup 39}K and subsequent loading into the chip trap. We describe the details of the dual chamber vacuum system, the cooling lasers, the magnetic trap, the multicoil magnetic transport system, the atom chip, and two optical dipole traps. Due in part to the use of light-induced atom desorption, the laser cooling chamber features a sufficiently good vacuum to also support optical dipole trap-based experiments. The apparatus is well suited for studies of atom-surface forces, quantum pumping and transport experiments, atom interferometry, novel chip-based traps, and studies of one-dimensional many-body systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

The bound coherent neutron scattering length of the oxygen isotopes

The technique of neutron interferometry was used to measure the bound coherent neutron scattering length bcoh of the oxygen isotopes 17O and 18O. From the measured difference in optical path between two water samples, either H2 17O or H2 18O versus H2 natO, where nat denotes the natural isotopic composition, we obtain bcoh , 17O = 5.867(4) fm and bcoh , 18O = 6.009(5) fm, based on the accurately known value of bcoh , natO = 5.805(4) fm which is equal to bcoh , 16O within the experimental uncertainty. Our results for bcoh , 17O and bcoh , 18O differ appreciably from the standard tabulated values of 5.6(5) fm and 5.84(7) fm, respectively. In particular, our measured scattering length contrast of 0.204(3) fm between 18O and natO is nearly a factor of 6 greater than the tabulated value, which renders feasible neutron diffraction experiments using 18O isotope substitution and thereby offers new possibilites for measuring the partial structure factors of oxygen-containing compounds, such as water.

Fischer, Henry E↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

42 ENGINEERING↗

Decoherence-free neutron interferometry

Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗