Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Techniques for Improving Filters in Power Grid Contingency Analysis

In large-scale power transmission systems, predicting faults and preemptively taking corrective action to avoid them is essential to preventing rolling blackouts. The computational study of the constantly-shifting state of the power grid and its weaknesses is called contingency analysis. Multiple-contingency planning in the electrical grid is one example of a complex monitoring system where a full computational solution is operationally infeasible. We present a general framework for building and evaluating resource-aware models of filtering techniques for this type of monitoring.

Adolf, Robert D.↗

Distinguishing Single and Linked Ruptures in the Laboratory and Nature

Earthquakes can grow either monotonically from a single, stressed patch or through linking multiple stressed regions. The distinction has implications for magnitude predictability with single ruptures requiring knowledge of the local stress state, while linked ruptures require knowing the global stress and energy distribution. Here, we use a laboratory fault that allows direct observation of slip to determine which fault conditions promote linked ruptures, and how to observationally evaluate their likelihood. Higher concentrations of normal stress due to increased normal force, applied stress asperities, or larger heterogeneity between the samples, all lead to significant increases in linked rupture likelihood. The mean radiated energy enhancement factor (REEF) of large events is an excellent proxy for linked event likelihood, and a combination of REEF and duration can identify the rupture style of some but not all events. The results imply that globally observed variations of REEF can be interpreted as variations in stress concentration.

earthquakes↗

Evaluation of Smart Grid Technologies Employed for System Reliability Improvement: Pacific Northwest Smart Grid Demonstration Experience

The Pacific Northwest Smart Grid Demonstration (PNWSGD) was a smart grid technology performance evaluation project that included multiple U.S. states and cooperation from multiple electric utilities in the northwest region. One of the local objectives for the project was to achieve improved distribution system reliability. Toward this end, some PNWSGD utilities automated their distribution systems, including the application of fault detection, isolation, and restoration and advanced metering infrastructure. In light of this investment, a major challenge was to establish a correlation between implementation of these smart grid technologies and actual improvements of distribution system reliability. This paper proposes using Welch’s t-test to objectively determine and quantify whether distribution system reliability is improving over time. The proposed methodology is generic, and it can be implemented by any utility after calculation of the standard reliability indices. The effectiveness of the proposed hypothesis testing approach is demonstrated through comprehensive practical results. It is believed that wider adoption of the proposed approach can help utilities to evaluate a realistic long-term performance of smart grid technologies.

Agalgaonkar, Yashodhan P. (ORCID:0000000290061848)↗

Online monitoring of rod control systems in combustion engineering pressurized water reactors - 195

Current designs of Pressurized Water Reactors (PWRs) are equipped with control and shutdown rods that are inserted and withdrawn from the reactor core to control reactivity. In Combustion Engineering (CE) plants, these rods are moved using the Control Element Drive Mechanism (CEDM) and controlled by the CEDM Control System (CEDMCS). In the event of system failure, troubleshooting activities can have a substantial impact on plant resources. Furthermore, CEDM component failures have occurred without warning, which has led to increased costs for the plants. These issues, combined with the inherently complex design of the CEDMCS, create a need for an online diagnostics system that can improve system health monitoring, increase diagnostic capabilities, and decrease troubleshooting time. This paper describes an advanced analysis and diagnostics system that monitors the CEDMCS during plant operation and provides critical information to onsite personnel to help detect and prevent problems before they impact normal plant operation. This system uses existing CEDMCS test points to acquire data and needs no modifications to the CEDMCS for implementation. The online monitoring capabilities automatically collect data during normal operation and diagnose failure events, reduce troubleshooting time and provide plant personnel with valuable information which is not currently available. Additionally, the system has built-in features used to streamline routine surveillance testing, collect stationary and movement data on multiple rods simultaneously, automate analysis, and generate reports. This system was developed with input from industry CEDMCS engineers at existing commercial facilities and has been deployed in multiple operating nuclear plants. The system has demonstrated itself to be a valuable tool for CEDMCS health monitoring, not only in reducing required man-power for routine system testing, but also in detected impending coil faults and allowing plant engineers to mitigate system component failures to prevent impending plant shut downs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Understanding Vibration Spectra of Planetary Gear Systems for Fault Detection

An understanding of the vibration spectra is very useful for any gear fault detection scheme based upon vibration measurements. The vibration measured from planetary gears is complicated. Sternfeld noted the presence of sidebands about the gear mesh harmonics spaced at the planet passage frequency in spectra measured near the ring gear of a CH-47 helicopter. McFadden proposes a simple model of the vibration transmission that predicts high spectral amplitudes at multiples of the planet passage frequency, for planetary gears with evenly spaced planets. This model correctly predicts no strong signal at the meshing frequency when the number of teeth on the ring gear is not an integer multiple of the number of planets. This paper will describe a model for planetary gear vibration spectra developed from the ideas started in reference. This model predicts vibration to occur only at frequencies that are multiples of the planet repetition passage frequency and clustered around gear mesh harmonics. Vibration measurements will be shown from tri-axial accelerometers mounted on three different planetary gear systems and compared with the model. The model correctly predicts the frequencies with large components around the first several gear mesh harmonics in measurements for systems with uniformly and nonuniformly spaced planet gears. Measurements do not confirm some of the more detailed features predicted by the model. Discrepancies of the ideal model to the measurements are believed due to simplifications in the model and will be discussed. Fault detection will be discussed applying the understanding will be discussed.

Mosher, Marianne↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Autoencoder-Based Sensor Drift Detection and Mitigation for Resilient Charging Systems

This work presents an autoencoder-based approach for sensor signal reconstruction and drift detection for charging systems. The proposed strategy is implemented within a Simulink-based system framework and evaluated under multiple operating conditions. An autoencoder with 8 neurons in the bottleneck layer is adopted, achieving accurate reconstruction across 10 variables and strong agreement with the physical sensor readings under normal conditions. In the case of a sensor fault, the autoencoder reconstruction remains closer to the expected true value compared to the corrupted measurement. Furthermore, feeding the autoencoder-reconstructed signal value back into the control framework in place of the faulty sensor signal leads to improved power monitoring. These results highlight the potential of autoencoder-based virtual sensing to extend the concept of resiliency to all components of the charging system, including sensors.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Advanced Geomechanical Model to Predict the Impact of CO2-Induced Microstructural Alterations on the Cohesive-Frictional Behavior of Mt. Simon Sandstone

We investigated the influence of CO2-induced geochemical reactions on the cohesive-frictional properties of host rock within the context of CO2 storage in a saline aquifer and focused on the Mt. Simon sandstone. The research objective was to model geo-mechanical changes due to host rock exposure to CO2-saturated brine while accounting for heterogeneity, double-scale porosity, and granular structure. We formulated a three-level multi-scale model for host rocks. We conducted scanning electron microscopy analyses to probe the microstructure and grid nanoindentation to measure the mechanical response. We derived new nonlinear strength upscaling solutions to correlate the effective strength characteristics and the macroscopic yield surface to the micro-structure at the nano-, micro-, and meso-scales. Specifically, our theoretical model links CO2-induced microstructural alterations to a reduction in the size of the yield surface, and a drop in the value of the friction coefficient. In turn, regarding the Illinois Basin Decatur Project, the CO2-induced drop in friction coefficient is linked to an increase in the risk of fault slip and a higher probability of induced microseismicity during and after the end of CO2 underground injection operations. The theoretical model presented is essential for the geo-mechanical modeling of CO2 underground injection operations at multiple length-scales.

58 GEOSCIENCES↗

Effects of variation in look angle and wavelength in radar images of volcanic and aeolian terrains, or now you see it, now you don't

The effects of look angle and wavelength variation in geologically applied radar images are examined and the applications of observations of these effects for the study of other planets are discussed. Seasat, SIR-A, SIR-B, and airborne radar images and multiple look angle and multiwavelength scatterometer data are used. It is found that smaller look angle radar data can provide good discrimination among certain diverse materials which are not distinguishable at larger look angles, such as subpixel fault scarps and volcanic dykes. Discriminant analyses of scatterometer data of all geological targets observed gave best results with minimum data by using all wavelengths available and small look angles. The results provide information on the nature of radar images which could be valuable in interpreting radar images of Venus.

Blom, Ronald G.↗

The use of self checks and voting in software error detection - An empirical study

The results of an empirical study of software error detection using self checks and N-version voting are presented. Working independently, each of 24 programmers first prepared a set of self checks using just the requirements specification of an aerospace application, and then each added self checks to an existing implementation of that specification. The modified programs were executed to measure the error-detection performance of the checks and to compare this with error detection using simple voting among multiple versions. The analysis of the checks revealed that there are great differences in the ability of individual programmers to design effective checks. It was found that some checks that might have been effective failed to detect an error because they were badly placed, and there were numerous instances of checks signaling nonexistent errors. In general, specification-based checks alone were not as effective as specification-based checks combined with code-based checks. Self checks made it possible to identify faults that had not been detected previously by voting 28 versions of the program over a million randomly generated inputs. This appeared to result from the fact that the self checks could examine the internal state of the executing program, whereas voting examines only final results of computations. If internal states had to be identical in N-version voting systems, then there would be no reason to write multiple versions.

Leveson, Nancy G.↗

On-Ramp Wireless: Program Final Report

The objective of the project was to develop and demonstrate a centrally managed, wide area wireless distribution grid sensor and faulted circuit indicator system capable of monitoring underground and other hard-to-reach distribution circuits while delivering the reliability, ease of installation, security, battery life and low cost structure required to be a commercially viable product for the electric utility industry. This integrated wireless grid monitoring system enables utilities across the United States to enhance the reliability of their distribution grids, improve performance metrics (i.e., SAIFI, CAIDI, SAIDI), support dynamic load management and predictive maintenance, and enable future remote monitoring applications necessary to achieve the goals of the Smart Grid. This project scope included: conceptual design; trade studies focused on maximizing ease of installation, sensing capabilities, power budget analysis to reduce maintenance costs and time to replace; sensor product development; and field technology demonstration. The trade studies included Radio Frequency (RF) propagation. The RF Trade Study was completed for the 2.4 GHz ISM-band and not extended to 1 GHz band due to availability of suitable radio solutions and associated impacts to overall commercial value of the solution. The technology demonstrations/field trials were performed in partnership with Southern California Edison and San Diego Gas and Electric. The sensing systems included fault indicator and wireless analog sensor devices from Schweitzer Engineering Labs (SEL) and smart transformer monitoring devices from Gridsense. Both SEL and Gridsense worked with ORW during this project to During the demonstration phase, sensors were deployed in multiple locations. Resulting data was analyzed for the following: RF performance, communication systems reliability, sensor system capabilities, and system level analytics relative to the commercial value to the smart grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pajarito Fault System Paleoseismic Trenching Project: Phase 1 Report

The Pajarito fault system (PFS) is a late Quaternary, 50-km-long fault system that bounds the western margin of the Rio Grande rift and crosses the western margin of Los Alamos National Laboratory (LANL) in Los Alamos, NM. As currently interpreted, the PFS is the largest contributing seismic source to ground motion hazard at LANL (Wong et al., 2007). Thus, understanding the fault system’s paleoseismic history is important for characterizing seismic hazard at LANL. The PFS consists of several distinct fault sections, from south to north, the Pajarito fault (PF), Guaje Mountain fault (GMF), Rendija Canyon fault (RCF) and Santa Clara Canyon fault (SCCF) (Wong et al., 2007). In the 2007 seismic source model for the LANL PSHA (Wong et al., 2007), the PFS is interpreted to be a single segmented rupture source. An earthquake recurrence model for the PFS was developed for the PSHA based primarily on the results of previous paleoseismic studies performed on the PF, RCF, and GMF (no detailed paleoseismic studies have been performed on the SCCF). LANL’s 2007 updated probabilistic seismic hazard analysis heavily favored the three Holocene event paleoearthquake model, despite having no single subsurface trenching investigation yield evidence for multiple earthquakes in the Holocene. Sensitivity analyses from the most recent PSHA update (Wong et al., 2007) and subsequent review by the LANL Update Steering Committee (USC, 2013) show that the recurrence of earthquakes within the Holocene epoch (~11,700 years ago to the present) along the PFS is significant to hazard. The USC (2013) recommended additional paleoseismic information be collected on the Pajarito fault section of the PFS to test recurrence models presented by Wong et al. (2007) and Lewis et al. (2009). To address the USC (2013) recommendations, a multi-year paleoseismic investigation of the PFS was conceived consisting of several field phases to evaluate the Holocene earthquake history of the PFS. This report presents the results from the initial Phase 1 paleoseismic investigation of the Pajarito fault. Phase 1 included the excavation and interpretation of six paleoseismic trenches, two each at three separate locations on the Pajarito fault - Sites A, B, and C. Sites B and C were located on the primary trace of the Pajarito fault, and Site A was located on an antithetic trace of the Pajarito fault east of the main fault.

58 GEOSCIENCES↗

Inference of Rock Flow and Mechanical Properties from Injection-Induced Microseismic Events During Geologic CO 2 Storage

Monitoring microseismic activities during CO 2 injection into geologic formations is important for ensuring the safety of the storage operations. The resulting data provide insight into the response of the storage formation to CO 2 injection and can be used to infer the underlying rock flow and mechanical properties. In this paper, assimilation of microseismic data is performed for dynamic characterization of the storage formation by using a stochastic simulation model to forecast the microseismic response of a geologic formation during CO 2 injection. Two modeling approaches are adopted to predict the space-time distribution of the injection-induced microseismicity. The first model is based on pore pressure relaxation assumption, while the second model uses coupled flow and geomechanics simulation to establish the complex physical relation between the storage formation properties and the corresponding microseismic responses during CO 2 injection. The stochastic predictive models in each case are used in ensemble data assimilation frameworks to estimate rock properties from the observed microseismic data. Two data assimilation methods are considered: (i) a new ensemble-based stochastic point process filter (EnPPF) that can directly integrate discrete microseismic events, and (ii) a variant of ensemble smoother, known as the ensemble smoother with multiple data assimilation (ES-MDA), which requires continuous representation of microseismic events for assimilation. The two methods are successfully applied to a geologically realistic model of the Farnsworth Field in Texas, with complex geologic flow units and interacting fault systems.

42 ENGINEERING↗

Spacelab Life Sciences-1 electrical diagnostic expert system

The Spacelab Life Sciences-1 (SLS-1) Electrical Diagnostic (SLED) expert system is a continuous, real time knowledge-based system to monitor and diagnose electrical system problems in the Spacelab. After fault isolation, the SLED system provides corrective procedures and advice to the ground-based console operator. The SLED system updates its knowledge about the status of Spacelab every 3 seconds. The system supports multiprocessing of malfunctions and allows multiple failures to be handled simultaneously. Information which is readily available via a mouse click includes: general information about the system and each component, the electrical schematics, the recovery procedures of each malfunction, and an explanation of the diagnosis.

Kao, C. Y.↗

Spacelab Life Sciences-1 electrical diagnostics expert system

The Spacelab Life Sciences-1 (SLS-1) Electrical Diagnostic (SLED) expert system is a continuous real time knowledge-based system to monitor and diagnose electrical system problems in the Spacelab. After fault isolation, the SLED system provides corrective procedures and advice to the ground-based console operator. The SLED system updates its knowledge about the status of Spacelab every 3 seconds. The system supports multiprocessing of malfunctions and allows multiple failures to be handled simultaneously. Information which is readily available via a mouse click includes: general information about the system and each component, the electrical schematics, the recovery procedures of each malfunction, and an explanation of the diagnosis.

Kao, Cheng Y.↗

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health↗

Benefits and Challenges of Model-based Software Engineering: Lessons Learned based on Qualitative and Quantitative Findings

Even though Model-based Software Engineering (MBSwE) techniques and Autogenerated Code (AGC) have been increasingly used to produce complex software systems, there is only anecdotal knowledge about the state-of-thepractice. Furthermore, there is a lack of empirical studies that explore the potential quality improvements due to the use of these techniques. This paper presents in-depth qualitative findings about development and Software Assurance (SWA) practices and detailed quantitative analysis of software bug reports of a NASA mission that used MBSwE and AGC. The mission’s flight software is a combination of handwritten code and AGC developed by two different approaches: one based on state chart models (AGC-M) and another on specification dictionaries (AGC-D). The empirical analysis of fault proneness is based on 380 closed bug reports created by software developers. Our main findings include: (1) MBSwE and AGC provide some benefits, but also impose challenges. (2) SWA done only at a model level is not sufficient. AGC code should also be tested and the models and AGC should always be kept in-sync. AGC must not be changed manually. (3) Fixes made to address an individual bug report were spread both across multiple modules and across multiple files. On average, for each bug report 1.4 modules, that is, 3.4 files were fixed. (4) Most bug reports led to changes in more than one type of file. The majority of changes to auto-generated source code files were made in conjunction to changes in either file with state chart models or XML files derived from dictionaries. (5) For newly developed files, AGC-M and handwritten code were of similar quality, while AGC-D files were the least fault prone.

Goseva-Popstojanova, Katerina↗