Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “missing data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Dark Matter Reconstruction in LBAI Experiments with Imperfect Data

Long-baseline atom interferometer (LBAI) experiments offer unprecedented sensitivity to ultralight scalar dark matter (DM) [1], however reconstruction of a putative DM signal with traditional frequency-domain analysis requires ``perfect data (i.e., regularly-sampled with no missing samples). In a real LBAI experiment, there will undoubtedly be imperfections in the data leading to downtime. This downtime can arise from operational considerations (e.g., maintenance), the operational environment (motion of people and animals [2] or elevators), and robustness of the experimental apparatus (e.g., bad atom launches). In this work, we investigate the impact of various downtime models on the overall DM sensitivity of such an experiment. We compare the sensitivity for each downtime model as determined by a ``compound FFT analysis to a baseline no-downtime case. We also show how much sensitivity can be regained by moving to a Lomb-Scargle frequency analysis, as in [2]. Furthermore, we demonstrate reconstruction of the DM wave s phase as well as its frequency. [1] D. Antypas, et al, ``New Horizons: Scalar and Vector Ultralight Dark Matter (2022). arXiv:2203.14915 [2] J. Carlton and C. McCabe, ``From RATs to riches: mitigating anthropogenic and synanthropic noise in atom interferometer searches for ultra-light dark matter (2023). arXiv:2308.101731

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics

Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed by identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.

Environmental Molecular Sciences Laboratory↗

Combination of CDF and D0 results on the mass of the top quark using up to 5.8~fb-1 of data

We summarize the top-quark mass measurements from the CDF and D0 experiments at Fermilab. We combine published Run I (1992--1996) measurements with the most precise published and preliminary Run II (2001--present) measurements using up to 5.8 fb{sup -1} of data, adding new analyses (the missing transverse energy plus jets analysis) and updating old ones. Taking uncertainty correlations into account, and adding in quadrature the statistical and systematic uncertainties, the resulting preliminary Tevatron average mass of the top quark is M{sub t} = 173.2 {+-} 0.9 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Search for pair production of first-generation leptoquarks in p pbar collisions at sqrt(s)=1.96 TeV

A search for pair production of first-generation leptoquarks (LQ) is performed with data collected by the D0 experiment in p{bar p} collisions at {radical}s = 1.96 TeV at the Fermilab Tevatron Collider. In a sample of data corresponding to {approx} 1 fb{sup -1} the search has been performed on the final states with two electrons and two jets or one electron, two jets and missing transverse energy. We find our data consistent with standard model expectations. The results are combined with those found in a previous analysis of events with two jets and missing transverse energy to obtain scalar LQ mass limits. We set 95% C.L. lower limits on a scalar LQ mass of 299 GeV, 284 GeV and 216 GeV for {beta} = 1, {beta} = 0.5 and {beta} = 0.02 respectively, where {beta} is the LQ branching ratio in the eq channel. This improves the results obtained with a lower luminosity sample from Run II of the Tevatron. Lower limits on vector LQ masses with different couplings from 357 GeV to 464 GeV for {beta} = 0.5 are also set using this analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PHYSICS OF ECLIPSING BINARIES. II. TOWARD THE INCREASED MODEL FIDELITY

The precision of photometric and spectroscopic observations has been systematically improved in the last decade, mostly thanks to space-borne photometric missions and ground-based spectrographs dedicated to finding exoplanets. The field of eclipsing binary stars strongly benefited from this development. Eclipsing binaries serve as critical tools for determining fundamental stellar properties (masses, radii, temperatures, and luminosities), yet the models are not capable of reproducing observed data well, either because of the missing physics or because of insufficient precision. This led to a predicament where radiative and dynamical effects, insofar buried in noise, started showing up routinely in the data, but were not accounted for in the models. PHOEBE (PHysics Of Eclipsing BinariEs; http://phoebe-project.org) is an open source modeling code for computing theoretical light and radial velocity curves that addresses both problems by incorporating missing physics and by increasing the computational fidelity. In particular, we discuss triangulation as a superior surface discretization algorithm, meshing of rotating single stars, light travel time effects, advanced phase computation, volume conservation in eccentric orbits, and improved computation of local intensity across the stellar surfaces that includes the photon-weighted mode, the enhanced limb darkening treatment, the better reflection treatment, and Doppler boosting. Here we present the concepts on which PHOEBE is built and proofs of concept that demonstrate the increased model fidelity.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection and Production of Methane Hydrate

This project seeks to understand regional differences in gas hydrate systems from the perspective of as an energy resource, geohazard, and long-term climate influence. Specifically, the effort will: (1) collect data and conceptual models that targets causes of gas hydrate variance, (2) construct numerical models that explain and predict regional-scale gas hydrate differences in 2-dimensions with minimal 'free parameters', (3) simulate hydrocarbon production from various gas hydrate systems to establish promising resource characteristics, (4) perturb different gas hydrate systems to assess potential impacts of hot fluids on seafloor stability and well stability, and (5) develop geophysical approaches that enable remote quantification of gas hydrate heterogeneities so that they can be characterized with minimal costly drilling. Our integrated program takes advantage of the fact that we have a close working team comprised of experts in distinct disciplines. The expected outcomes of this project are improved exploration and production technology for production of natural gas from methane hydrates and improved safety through understanding of seafloor and well bore stability in the presence of hydrates. The scope of this project was to more fully characterize, understand, and appreciate fundamental differences in the amount and distribution of gas hydrate and how this would affect the production potential of a hydrate accumulation in the marine environment. The effort combines existing information from locations in the ocean that are dominated by low permeability sediments with small amounts of high permeability sediments, one permafrost location where extensive hydrates exist in reservoir quality rocks and other locations deemed by mutual agreement of DOE and Rice to be appropriate. The initial ocean locations were Blake Ridge, Hydrate Ridge, Peru Margin and GOM. The permafrost location was Mallik. Although the ultimate goal of the project was to understand processes that control production potential of hydrates in marine settings, Mallik was included because of the extensive data collected in a producible hydrate accumulation. To date, such a location had not been studied in the oceanic environment. The project worked closely with ongoing projects (e.g. GOM JIP and offshore India) that are actively investigating potentially economic hydrate accumulations in marine settings. The overall approach was fivefold: (1) collect key data concerning hydrocarbon fluxes which is currently missing at all locations to be included in the study, (2) use this and existing data to build numerical models that can explain gas hydrate variance at all four locations, (3) simulate how natural gas could be produced from each location with different production strategies, (4) collect new sediment property data at these locations that are required for constraining fluxes, production simulations and assessing sediment stability, and (5) develop a method for remotely quantifying heterogeneities in gas hydrate and free gas distributions. While we generally restricted our efforts to the locations where key parameters can be measured or constrained, our ultimate aim was to make our efforts universally applicable to any hydrate accumulation.

03 NATURAL GAS↗

An active drop counting device using condenser microphone for superheated emulsion detector

An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Vacancies, Faults, and Superstructures in Ln 5 Mo 2 O 12 (Ln = La, Y, and Lu) Compounds with Direct Mo–Mo Bonding

Among oxide compounds with direct metal–metal bonding, the Y 5 Mo 2 O 12 (A 5 B 2 O 12 ) structural family of compounds has a particularly intriguing low-dimensional structure due to the presence of bioctahedral B 2 O 10 dimers arranged in one-dimensional edge-sharing chains along the direction of the metal–metal bonds. Furthermore, these compounds can have a local magnetic moment due to the noninteger oxidation state (+4.5) of the transition metal, in contrast to the conspicuous lack of a local moment that is commonly observed when oxide compounds with direct metal–metal bonding have integer oxidation states resulting from the lifting of orbital degeneracy typically induced by the metal–metal bonding. Although a monoclinic C2/m structure has been previously proposed for Ln 5 Mo 2 O 12 (Ln = La–Lu and Y) members of this family based on prior single crystal diffraction data, it is found that this structural model misses many important structural features. On the basis of synchrotron powder diffraction data, it is shown in this paper that the C2/m monoclinic unit cell represents a superstructure relative to a previously unrecognized orthorhombic Immm subcell and that the superstructure derives from the ordering of interchangeable Mo 2 O 10 and LaO 6 building blocks. The superstructure for this reason is typically highly faulted, as evidenced by the increased breadth of superstructure diffraction peaks associated with a coherence length of 1–2 nm in the c* direction. Finally, it is shown that oxygen vacancies can occur when Ln = La, producing an oxygen deficient stoichiometry of La 5 Mo 2 O 11.55 and an approximately 10-fold reduction in the number of unpaired electrons due to the reduction of the average Mo valence from +4.5 to +4.05, a result confirmed by magnetic susceptibility measurements. Finally, this represents the first observation of oxygen vacancies in this family of compounds and provides an important means of continuously tuning the magnetic interactions within the one-dimensional octahedral chains of this system.

36 MATERIALS SCIENCE↗

Search for top squark pair production using dilepton final states in ${\text {p}}{\text {p}}$ collision data collected at $\sqrt{s}=13\,\text {TeV} $

A search is presented for supersymmetric partners of the top quark (top squarks) in final states with two oppositely charged leptons (electrons or muons), jets identified as originating from ${\text {b}}$quarks, and missing transverse momentum. The search uses data from proton-proton collisions at $\sqrt{s}=13\,\text {TeV} $ collected with the CMS detector, corresponding to an integrated luminosity of 137$\,{\text {fb}}^{-1}$. Hypothetical signal events are efficiently separated from the dominant top quark pair production background with requirements on the significance of the missing transverse momentum and on transverse mass variables. No significant deviation is observed from the expected background. Exclusion limits are set in the context of simplified supersymmetric models with pair-produced lightest top squarks. For top squarks decaying exclusively to a top quark and a lightest neutralino, lower limits are placed at $95\%$ confidence level on the masses of the top squark and the neutralino up to 925 and 450$\,\text {GeV}$, respectively. If the decay proceeds via an intermediate chargino, the corresponding lower limits on the mass of the lightest top squark are set up to 850$\,\text {GeV}$ for neutralino masses below 420$\,\text {GeV}$. For top squarks undergoing a cascade decay through charginos and sleptons, the mass limits reach up to 1.4$\,\text {TeV}$ and 900$\,\text {GeV}$ respectively for the top squark and the lightest neutralino.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of Localization Effects on Transverse Kinematic Imbalance in the GENIE Generator

The forthcoming Deep Underground Neutrino Experiment (DUNE) requires precise modeling of neutrino--nucleus interactions to achieve its neutrino-oscillation measurement goals. GENIE, the Monte Carlo event generator used by DUNE and other Fermilab-based experiments as a central value model for neutrino-nucleus cross sections, exhibits known discrepancies in comparison to MicroBooNE cross section data, especially when considering neutrino scattering events' transverse kinematic imbalance (TKI). For quasielastic-like measurements, the data show a larger transverse missing momentum tail while maintaining a peak similar to that predicted by the baseline GENIE model. Previous attempts at a solution include variations of final-state interaction (FSI) strengths, incorrectly decreasing both the peak and tail, thus leaving the discrepancy unresolved. This work investigates whether inconsistencies between local and global treatments of intranuclear physics contribute to the observed mismodeling. In this work, GENIE FSI routines have been modified to directly utilize intranuclear particle positions, thereby introducing a newly localized momentum treatment in correlation with the nominal density in both the hA and hN intranuclear cascade models for their 2018 and 2025 variants. Meson-exchange-current (MEC) localization was also tested for the hN 2018 model. Comparisons of the intranuclear nucleons' ("scattering center") momentum and its radial dependence validate the localization implementation. However, while such consistent localization produces modest changes in the proton momentum spectrum at low-to-medium momenta, only small changes are observed in the TKI distributions. These changes are insufficient to account for the discrepancy with MicroBooNE data. Although a localized treatment improves the internal consistency of the GENIE model, the origin of the TKI discrepancy remains unresolved by such a solution.

Bulla, Braden [Ctr. Coll., Danville; Fermilab]↗

Generalized Bayesian Framework for Evaluation of Integral Benchmark Experiments

A recently published generalized Bayesian optimization framework has provided a way to retract any or all of the three common assumptions underlying the conventional Generalized Linear Least Squares (GLLS) optimization method based on the concepts introduced in reference two. These assumptions are: 1. Perfection: The model used for data evaluation and the prior probability distribution function (PDF) of generalized* data are perfect; 2. Normality: The prior and posterior PDF are normal; and 3. Linearity: The model is linear. In this work we outline how the framework in 1 could be directly adopted for improved evaluation of nuclear criticality integral benchmark experiments (IBEs) by: 1. Removing the first assumption alone by utilizing the concept of imperfections introduced in 1 to enable evaluation in the presence of discrepancies between the data and model or of missing covariance information by a GLLS method that will be seen as a generalization of the conventional GLLS method employed by the TSURFER code, and by 2. Removing the remaining two assumptions by implement- ing a Markov Chain Monte Carlo method for computation of the posterior PDF in the SAMPLER code, where TSURFER and SAMPLER are the uncertainty quantification (UQ) codes for IBEs in the SCALE code system based on the GLLS, and the stochastic method, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for supersymmetry in events with large missing transverse momentum, jets, and at least one tau lepton in 20 fb − 1 of s = 8 TeV proton-proton collision data with the ATLAS detector

CERN-LHC. A search for supersymmetry (SUSY) in events with large missing transverse momentum, jets, at least one hadronically decaying tau lepton and zero or one additional light leptons (electron/muon), has been performed using 20.3 fb^-1 of proton-proton collision data at sqrt(s)=8 TeV recorded with the ATLAS detector at the Large Hadron Collider. No excess above the Standard Model background expectation is observed in the various signal regions and 95% confidence level upper limits on the visible cross section for new phenomena are set. The results of the analysis are interpreted in several SUSY scenarios, significantly extending previous limits obtained in the same final states. In the framework of minimal gauge-mediated SUSY breaking models, values of the SUSY breaking scale Lambda below 63 TeV are excluded, independently of tan(beta). Exclusion limits are also derived for an mSUGRA/CMSSM model, in both the R-parity-conserving and R-parity-violating case. A further interpretation is presented in a framework of natural gauge mediation, in which the gluino is assumed to be the only light coloured sparticle and gluino masses below 1090 GeV are excluded.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Vector and Tensor Asymmetries at Large Missing Momentum in Quasielastic ( e → , e ' p ) Electron Scattering from Deuterium

Here, we report the measurement of the beam-vector and tensor asymmetries A e d V and A d T in quasielastic ( e → , e ' p ) electrodisintegration of the deuteron at the MIT-Bates Linear Accelerator Center up to missing momentum of 500 MeV / c . Data were collected simultaneously over a momentum transfer range 0.1 < Q 2 < 0.5 ( GeV / c ) 2 with the Bates Large Acceptance Spectrometer Toroid using an internal deuterium gas target polarized sequentially in both vector and tensor states. The data are compared with calculations. The beam-vector asymmetry A e d V is found to be directly sensitive to the D -wave component of the deuteron and has a zero crossing at a missing momentum of about 320 MeV / c , as predicted. The tensor asymmetry A d T at large missing momentum is found to be dominated by the influence of the tensor force in the neutron-proton final-state interaction. The new data offer a strong constraint on theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data and Benchmarking Program: Nuclear Data Performance Assessment for Advanced Reactors

Over the last several Evaluated Nuclear Data File (ENDF)/B releases, many updates have been introduced to the nuclear data libraries that can significantly change computational results. These changes can be particularly important for advanced reactor concepts, which are not as thoroughly investigated as those used in light water reactor (LWR) systems. Therefore, a performance assessment of the ENDF/B libraries using the SCALE 6.2.3 code package was conducted under the auspices of the U.S., Department of Energy Office of Nuclear Energy (DOE-NE). The following systems relevant to the advanced reactor community were chosen as subject for investigation in this report: sodium cooled fast reactor systems, graphite moderated high temperature gas-cooled reactors, and several molten salt reactor models. At first, the similarity of the integral performance of the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries caused by compensating errors in important differential data was demonstrated. In calculations for a shipping container of high-assay low enriched uranium, the data of individual isotopes were systematically swapped between the two ENDF/B libraries. An eigenvalue difference of up to 450 pcm was found due to the use of 235 U and 238 U from one library and 1 H and 16 O from the other library. This clearly demonstrates a cross-correlation between reaction data sets of different isotopes within a library that should be reported in the evaluations. For sodium-cooled fast reactor (SFR) fuel assemblies, significant eigenvalue (k inf ) differences (200– 450 pcm) were found between calculations using the 2011 ENDF/B-VII.1 data and 2018 ENDF/B-VIII.0 data. These differences were mainly caused by updates of 238 U and 239 Pu neutron cross sections. Results from the multigroup (MG) calculations further revealed that the group structure of the applied MG library strongly influences the MG bias due to the importance of an appropriate energy resolution of the resonances in higher energy ranges. The application of previously used MG libraries requires new verification for advanced reactor simulation in comparisons with reference continuous-energy calculations. Nuclear data uncertainty analyses of these SFR systems resulted in eigenvalue uncertainties between 1,400 and 1,800 pcm, which are three to four times higher than corresponding uncertainties in light water reactor (LWR) systems. The main contributor to this uncertainty was found to be inelastic scattering on 238 U, which shows an uncertainty of up to 50% in the fast energy range. Other important contributors are the scattering reactions of 56 Fe and 23 Na which have so far not appeared in LWR analysis. Since the largest contribution to the eigenvalue uncertainty of SFR systems is coming from scattering reactions, it is expected that uncertainties in the angular scattering distributions also have a significant impact. Those uncertainties are, however, not available for the majority of nuclides, and the capabilities to determine sensitivities to this data are currently underdeveloped. For two graphite moderated high temperature gas-cooled reactor (HTGR) benchmarks, only the ENDF/BVII. 1 calculations resulted in consistent eigenvalues (k eff ) with the corresponding experimental measurements. Eigenvalue differences of about 1,000 pcm were found between the 2006 ENDF/B-VII.0 data and the 2011 ENDF/B-VII.1 data, primarily due to an updated carbon capture cross section in the thermal energy range in the later ENDF/B release. The ENDF/B-VIII.0 eigenvalue was larger than the ENDF/B-VII.1 eigenvalue by about 300 pcm mainly due to updates in multiple 235 U neutron cross sections, with offsetting updates in the 238 U cross sections. With ENDF/B-VIII.0, graphite can be modeled as perfect crystal or with two different porosities. The choice of the graphite evaluation can have a significant influence of the eigenvalue. For a HTGR benchmark, maximum eigenvalue differences as high as 650 pcm due to different porosities were observed. More detailed studies of the impact of the porosity are necessary while considering that the graphite porosity can vary between the used materials and changes as a function of neutron fluence. xii The uncertainty of the HTGR eigenvalues due to nuclear data uncertainties was found between 500 and 600 pcm, with the top contributor being the neutron multiplicity of 235 U. A gap in the form of missing uncertainties in graphite thermal scattering data, that might have significant impact on HTGR reactors, was identified. This gap is being investigated by the DOE-NE Nuclear Data and Benchmarking Program, as documented in a separate report The fast spectrum molten salt reactor calculations revealed similar comparisons as for the SFR assemblies. The eigenvalue uncertainties were significantly influenced by inelastic scattering on 238 U, while the impact of angular scattering distributions is unknown. For the graphite and zirconium hydride moderated system, eigenvalue uncertainties of up to 700 pcm were observed, requiring in depth analyses of the cross sections and corresponding uncertainties of the included materials. In general, it was observed that the flux spectra of the various molten salt reactor systems show significant differences, even between a fresh state and a depleted state. The choice of the energy group structure of MG calculations is therefore highly relevant; the applicability of previously used MG libraries needs to be verified. Due the unavailability of pin power measurements of advanced reactor systems, pin power calculations with both ENDF/B-VII.1 and VIII.0 data were performed for a light water reactor and compared to corresponding measurements. Both calculations show good agreement with the measurements. A comparison between the ENDF/B-VII.1 and VIII.0 results revealed small differences, mostly in the range of about 0.2%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗