Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tensile and flexural strength of non-graphitic superhybrid composites: Predictions and comparisons

Equations are presented and described which can be used to predict bounds on the tensile and flexural strengths of nongraphitic superhybrid (NGSH) composites. These equations are derived by taking into account the measured stress-strain behavior, the lamination residual stresses and the sequence of events leading to fracture. The required input for using these equations includes constituents, properties (elastic and strength), NGSH elastic properties, cure temperature, and ply stress influence coefficients. Results predicted by these equations are in reasonably good agreement with measured data for strength and for the apparent knees in the nonlinear stress-strain curve. The lower bound values are conservative compared to measured data. These equations are relatively simple and are suitable for use in the preliminary design and initial sizing of structural components made from NGSH composites.

Chamis, C. C.↗

Tensile and flexural strength of nongraphitic superhybrid composites - Predictions and comparisons

Equations are presented and described which can be used to predict bounds on the tensile and flexural strengths of nongraphitic superhybrid (NGSH) composites. These equations are derived by taking into account the measured stress-strain behavior, the lamination residual stresses and the sequence of events leading to fracture. The required input for using these equations includes constituent composites, elastic and strength properties, NGSH elastic properties, cure temperature, and ply stress influence coefficients. Results predicted by these equations are in reasonably good agreement with measured data for strength and for the apparent 'knees' in the nonlinear stress-strain curve. The lower bound values are conservative compared to measured data. These equations are relatively simple and should be suitable for use in the preliminary design and initial sizing of structural components made from NGSH composites.

Chamis, C. C.↗

Optical-property coefficient estimation of bulky medium in experiments with a succinctly analytical calculation

Diffuse optical imaging enables to reconstruct distribution of optical properties, absorption and scattering coefficients, in tissue for breast cancer detection based on diffusion equation with the help of the initial guess obtained from measured data. To estimate the initial guess of the optical-property coefficients, an analytical solution of diffusion equation can be used and compared with the measured data. The analytical solution for a homogeneous infinite medium can be obtained in the frequency domain, expressing that the photon intensity and the phase lag relative to the distance between source and detector in a linear relationship. In this study, a succinct calculation using the trigonometric relation is proposed to estimate the optical-property coefficients. A tank-type and a cylinder Lipovenoes phantoms with two concentrations of 1.25% and 2.5% are employed and measured for verification. It is found that the method proposed here shows better results and results in estimation errors of 0–14.81% for μ{sub a} and 20–42% for μ{sub s}′.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alloy Shrinkage factors for the investment casting of 17-4PH stainless steel parts

In this study, the alloy shrinkage factors were obtained for the investment casting of 17-4PH stainless steel parts. For the investment casting process, unfilled wax and fused silica with a zircon prime coat were used for patterns and shell molds, respectively. Dimensions of the die tooling, wax pattern, and casting were measured using a Coordinate Measurement Machine. For all the properties, the experimental data available in the literature did not cover the entire temperature range necessary for process simulation. A comparison between the predicted material property data measured property data is made. It was found that most material properties were accurately predicted over the most of the temperature range of the process. Several assumptions were made in order to obtain a complete set of mechanical property data at high temperatures. Thermal expansion measurements for the 17-4PH alloy were conducted at heating and cooling. As a function of temperature, the thermal expansion for both the alloy and shell mold materials showed different evolution at heating and cooling. Thus, one generic simulation were performed with thermal expansion obtained at heating and another one with thermal expansion obtained at cooling. The alloy dimensions were obtained from numerical simulation results of solidification, heat transfer, and deformation phenomena. As compared with experimental results, the numerical simulation results for the shrinkage factors were slightly over-predicted.

36 MATERIALS SCIENCE↗

A hybrid technique for spacecraft attitude interpolation with arbitrary attitude data gaps

An algorithm for obtaining sufficiently accurate estimates of a system parameter Y, given a data record of the parameter in which at arbitrary times no direct observations of Y exist, and describing the variance of these estimates, is proposed. The method provides estimates at all requested times, and the variance of the estimates is maintained as close to the variance of directly measured data as the quality of input information will allow. Three classes of information are used: (1) the measured data record of Y and the statistical extension of this record into time intervals of no direct measurement, obtained by a modification of standard autocorrelation techniques; (2) an a priori indicator of the behavior of Y; and (3) one or more indirect indicators of Y based on observation of other system parameters. The application of the algorithm to the SEASAT-A attitude determination under conditions of sensor field-of-view limitations and sun occultations is presented.

Treder, A. J.↗

Boundary-layer stability analysis of flight-measured transition data

Correlation of in-flight boundary-layer transition experiments with linear boundary-layer stability theory contributes both to the validation of the numerical methods as well as the analysis of the measured transition process. Transition results obtained in a recent flight experiment, in which the extent of laminar flow and the transition process on the wing of a business-jet fitted with an instrumented glove section were determined, are analyzed. The experiment was conducted at freestream Mach numbers from 0.55 to 0.82, chord Reynolds numbers from 10 to 20 x 10 to the 6th, and leading-edge sweep angles 17 deg to 20 deg. The growth of both Tollmien-Schlichting and crossflow instabilities are predicted using the e exp n method for several flight conditions and the calculated n-factors at transition onset are correlated. Comparison of the measured dominant boundary-layer disturbance frequencies and the predicted unstable frequencies shows fair agreement for several of the flight conditions studied.

Obara, Clifford J.↗

A simple, analytical, axisymmetric microburst model for downdraft estimation

A simple analytical microburst model was developed for use in estimating vertical winds from horizontal wind measurements. It is an axisymmetric, steady state model that uses shaping functions to satisfy the mass continuity equation and simulate boundary layer effects. The model is defined through four model variables: the radius and altitude of the maximum horizontal wind, a shaping function variable, and a scale factor. The model closely agrees with a high fidelity analytical model and measured data, particularily in the radial direction and at lower altitudes. At higher altitudes, the model tends to overestimate the wind magnitude relative to the measured data.

Vicroy, Dan D.↗

Characterization and Design of Digital Pointing Subsystem for Optical Communication Demonstrator

The Optical Communications Demonstrator (OCD) is a laboratory-based lasercom demonstration terminal designed to validate several key technologies, including beacon acquisition, high bandwidth tracking, precision bearn pointing, and point-ahead compensation functions. It has been under active development over the past few years. The instrument uses a CCD array detector for both spatial acquisition and high-bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field-of-view acquisition and permits effective platform jitter compensation and point-ahead control using only one steering mirror. This paper describes the detailed design and characterization of the digital control loop system which includes the Fast Steering Mirror (FSM), the CCD image tracker, and the associated electronics. The objective is to improve the overall system performance using laboratory measured data. The. design of the digital control loop is based on a linear time invariant open loop model. The closed loop performance is predicted using the theoretical model. With the digital filter programmed into the OCD control software, data is collected to verify the predictions. This paper presents the results of the, system modeling and performance analysis. It has been shown that measurement data closely matches theoretical predictions. An important part of the laser communication experiment is the ability of FSM to track the laser beacon within the. required tolerances. The pointing must be maintained to an accuracy that is much smaller than the transmit signal beamwidth. For an earth orbit distance, the system must be able to track the receiving station to within a few microradians. The failure. to do so will result in a severely degraded system performance.

Racho, C.↗

Mars Aerobraking Spacecraft State Estimation by Processing Inertial Measurement Unit Data

Aerobraking is an efficient technique for orbit adjustment of planetary spacecraft, such as Magellan (Venus), Mars Global Surveyor, and Mars Odyssey. Determination of the vehicle state during the aerobraking phase has conventionally been performed using only radiometric tracking data prior to and following the atmospheric drag pass. This approach is sufficiently accurate and timely to meet current mission operational requirements; however, it is expensive in terms of ground support and leads to delayed results because ofthe need for post-drag pass data. This research presents a new approach to estimation of the vehicle state during the atmospheric pass that sequentially incorporates observations from an Inertial Measurement Unit (IMU) and models of the vehicle and environment. The approach, called Inertial Measurements for Aerobraking Navigation (IMAN), is shown to perform at a level comparable to the conventional methods in terms of navigation accuracy and superior to them in terms of availability of the results immediately after completion ofthe pass. Furthermore, the research shows that IMAN can be used to reliably predict subsequent periapsis times and locations over all aerobraking regimes. IMAN also yields accurate peak dynamic pressure and heating rates, critical for a successful corridor control strategy, comparable to navigation team reconstructed values. This research also provides the first instance of the utilization of the Unscented Kalman Filter for the purpose of estimating an actual spacecraft trajectory arc about another planet.

Unscented Kalman Filter↗

An Advanced ISOCS In Situ Gamma Spectrometry Services Tool to Reduce Uncertainties in Waste Characterization Projects - 16311

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function. It avoids the need for radioisotope standards which can be costly and prohibitively difficult to produce. Uncertainties in the sample - detector geometry lead to uncertainties in the calibrations. Canberra's ISOCS Uncertainty Estimator (IUE) tool offers an automated means of accommodating known model geometry uncertainties, with calculation of robust defensible calibration uncertainties. However these uncertainties may be large leading to potential over-estimation of under-estimation of activity. This can be equated directly to waste disposal costs if one is using ISOCS for waste sentencing to classify wastes as (for example) Transuranic Waste (TRU) or Low Level Waste (LLW). An Advanced ISOCS in-situ Gamma Spectrometry (AIGS) services tool has been developed to reduce the uncertainties. This system is based on generating and comparing geometry models that yield Figures of Merit (FoM) indicative of improved consistency between modelled data and available diverse measurement data. This paper describes the development and features of AIGS, focusing on recent testing with radioisotope sources in a 200 litre drum filled with a simulated waste matrix. The results demonstrate a significant advantage for Am-241 where uncertainties can otherwise amount to a factor of 2 or more. We show how our specialist teams can develop procedures for deployment of standard ISOCS hardware, adapting measurement geometries and procedures through careful planning, to provide data that can be used to greatly reduce the uncertainties in the measured activities. Lastly, we comment on the range of potential applications for this new technique and the wider benefits for the decommissioning industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Practical Framework for Sharing and Rendering Real-World Bidirectional Scattering Distribution Functions

The utilization of real-world materials has been hindered by a lack of standards for sharing and interpreting measured data. This paper presents an XML representation and an Open Source C library to support bidirectional scattering distribution functions (BSDFs) in data-driven lighting simulation and rendering applications.The library provides for the efficient representation, query, and Monte Carlo sampling of arbitrary BSDFs in amodel-free framework. Currently, we support two BSDF data representations: one using a fixed subdivision of thehemisphere, and one with adaptive density. The fixed type has advantages for certain matrix operations, while theadaptive type can more accurately represent highly peaked data. We discuss advanced methods for data-drivenBSDF rendering for both types, including the proxy of detailed geometry to enhance appearance and accuracy.We also present an advanced interpolation method to reduce measured data into these standard representations.We end with our plan for future extensions and sharing of BSDF data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PIV Uncertainty Methodologies for CFD Code Validation at the MIR Facility

Currently, computational fluid dynamics (CFD) is widely used in the nuclear thermal hydraulics field for design and safety analyses. To validate CFD codes, high quality multi dimensional flow field data are essential. The Matched Index of Refraction (MIR) Flow Facility at Idaho National Laboratory has a unique capability to contribute to the development of validated CFD codes through the use of Particle Image Velocimetry (PIV). The significance of the MIR facility is that it permits non intrusive velocity measurement techniques, such as PIV, through complex models without requiring probes and other instrumentation that disturb the flow. At the heart of any PIV calculation is the cross-correlation, which is used to estimate the displacement of particles in some small part of the image over the time span between two images. This image displacement is indicated by the location of the largest peak. In the MIR facility, uncertainty quantification is a challenging task due to the use of optical measurement techniques. Currently, this study is developing a reliable method to analyze uncertainty and sensitivity of the measured data and develop a computer code to automatically analyze the uncertainty/sensitivity of the measured data. The main objective of this study is to develop a well established uncertainty quantification method for the MIR Flow Facility, which consists of many complicated uncertainty factors. In this study, the uncertainty sources are resolved in depth by categorizing them into uncertainties from the MIR flow loop and PIV system (including particle motion, image distortion, and data processing). Then, each uncertainty source is mathematically modeled or adequately defined. Finally, this study will provide a method and procedure to quantify the experimental uncertainty in the MIR Flow Facility with sample test results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of actuator arrays for aircraft interior noise control

A numerical procedure for grouping actuators in order to reduce the number of degrees of freedom in an active noise control system is evaluated using experimental data. Piezoceramic actuators for reducing aircraft interior noise are arranged into groups using a nonlinear optimization routine and clustering algorithm. An actuator group is created when two or more actuators are driven with the same control input. This procedure is suitable for active control applications where actuators are already mounted on a structure. The feasibility of this technique is demonstrated using measured data from the aft cabin of a Douglas DC-9 fuselage. The measured data include transfer functions between 34 piezoceramic actuators and 29 interior microphones and microphone responses due to the primary noise produced by external speakers. Control inputs for the grouped actuators were calculated so that a cost function, defined as a quadratic pressure term and a penalty term, was a minimum. The measured transfer functions and microphone responses are checked by comparing calculated noise reductions with measured noise reductions for four frequencies. The grouping procedure is then used to determine actuator groups that improve overall interior noise reductions by 5.3 to 15 dB, compared to the baseline experimental configuration.

Cabell, R. H.↗

Measurement and Data Distribution for Microgravity Accelerations on the International Space Station

Two accelerometer systems will be available on the International Space Station to support microgravity payloads with information about the quasi-steady and vibratory acceleration environment of the research facilities. The Microgravity Acceleration Measurement System will record contributions to the quasi-steady microgravity environment, including the influences of aerodynamic drag, vehicle rotation, and venting effects. The Space Acceleration Measurement System-II will measure vibratory disturbances on-board due to vehicle, crew, and equipment disturbances. Due to the dynamic nature of the microgravity environment and its potential to influence sensitive experiments, NASA's Principal Investigator Microgravity Services project has initiated a plan through which the data from these instruments will be distributed to researchers in a timely and meaningful fashion. Beyond the obvious benefit of correlation between accelerations and the scientific phenomena being studied, such information is also useful for hardware developers who can gain qualitative and quantitative feedback about their facility acceleration output to station.

McPherson, Kevin↗

Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from a 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K{sub trans}) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K{sub trans} but with large uncertainty (111.6 ± 150.5) %. Conclusions: Parametric voxel-based analysis of 4D DCE CT data resulted in greater accuracy and reliability in measuring changes in perfusion CT-based kinetic metrics, which have the potential to be used as biomarkers in patients with metastatic brain cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Possibilistic measurement and set statistics

Set-based statistics are necessary to generate possibility distributions from measured data. Methods by which physical measurements can generate statistical data on real intervals are considered, including the following: trials from multiple heterogeneous measurement devices rather than a single instrument at multiple times; classes of consistent intervals constructed from statistical data around a common point focus or interval core; and consonant intervals constructed from statistical data.

Joslyn, Cliff↗

SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm{sup 3}) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

60 APPLIED LIFE SCIENCES↗