Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lung function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Four-Dimensional Lung Treatment Planning in Layer-Stacking Carbon Ion Beam Treatment: Comparison of Layer-Stacking and Conventional Ungated/Gated Irradiation

Purpose: We compared four-dimensional (4D) layer-stacking and conventional carbon ion beam distribution in the treatment of lung cancer between ungated and gated respiratory strategies using 4DCT data sets. Methods and Materials: Twenty lung patients underwent 4DCT imaging under free-breathing conditions. Using planning target volumes (PTVs) at respective respiratory phases, two types of compensating bolus were designed, a full single respiratory cycle for the ungated strategy and an approximately 30% duty cycle for the exhalation-gated strategy. Beams were delivered to the PTVs for the ungated and gated strategies, PTV(ungated) and PTV(gated), respectively, which were calculated by combining the respective PTV(Tn)s by layer-stacking and conventional irradiation. Carbon ion beam dose distribution was calculated as a function of respiratory phase by applying a compensating bolus to 4DCT. Accumulated dose distributions were calculated by applying deformable registration. Results: With the ungated strategy, accumulated dose distributions were satisfactorily provided to the PTV, with D95 values for layer-stacking and conventional irradiation of 94.0% and 96.2%, respectively. V20 for the lung and Dmax for the spinal cord were lower with layer-stacking than with conventional irradiation, whereas Dmax for the skin (14.1 GyE) was significantly lower (21.9 GyE). In addition, dose conformation to the GTV/PTV with layer-stacking irradiation was better with the gated than with the ungated strategy. Conclusions: Gated layer-stacking irradiation allows the delivery of a carbon ion beam to a moving target without significant degradation of dose conformity or the development of hot spots.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPOP promotes FADD degradation and inhibits NF-κB activity in non-small cell lung cancer

Highlights: • FADD protein level predicts poor prognosis of NSCLC patients. • SPOP binds to FADD and mediates its degradation. • SPOP inhibits NF-κB activity and its target genes expression. FAS-associated protein with death domain (FADD) is the pivotal adaptor protein, which transmits apoptotic signals mediated by the death receptors. Here we report that high FADD protein level predicts poor prognosis of non-small cell lung cancer (NSCLC) patients and its protein level is mainly regulated by the 26S proteasome. We also found that ubiquitin ligase SPOP (speckle-type POZ protein) binds to FADD and mediates its degradation, which can be blocked by MG132 treatment. Notably, SPOP inhibits NF-κB (nuclear factor kappa-light-chain-enhancer of activated B cells) activity and its target genes expression via FADD. These results reveal the function of SPOP-FADDNFκB axis in NSCLC cells, which is associated with prognosis of NSCLC patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface

Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: The water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.

61 RADIATION PROTECTION AND DOSIMETRY↗

Current understandings and perspectives on non-cancer health effects of benzene: A global concern

Objective: Benzene, as a volatile organic compound, is known as one of the main air pollutants in the environment. The aim of this review is to summarize all available evidences on non-cancerous health effects of benzene providing an overview of possible association of exposure to benzene with human chronic diseases, specially, in those regions of the world where benzene concentration is being poorly monitored. Methodology: A bibliographic search of scientific databases including PubMed, Google Scholar, and Scirus was conducted with key words of “benzene toxic health effects”, “environmental volatile organic compounds”, “diabetes mellitus and environmental pollutants”, “breast cancer and environmental pollution”, “prevalence of lung cancer”, and “diabetes prevalence”. More than 300 peer reviewed papers were examined. Experimental and epidemiologic studies reporting health effects of benzene and volatile organic compounds were included in the study. Results: Epidemiologic and experimental studies suggest that benzene exposure can lead to numerous non-cancerous health effects associated with functional aberration of vital systems in the body like reproductive, immune, nervous, endocrine, cardiovascular, and respiratory. Conclusion: Chronic diseases have become a health burden of global dimension with special emphasis in regions with poor monitoring over contents of benzene in petrochemicals. Benzene is a well known carcinogen of blood and its components, but the concern of benzene exposure is more than carcinogenicity of blood components and should be evaluated in both epidemiologic and experimental studies. Aspect of interactions and mechanism of toxicity in relation to human general health problems especially endocrine disturbances with particular reference to diabetes, breast and lung cancers should be followed up. - Highlights: • Benzene is a volatile organic compound and established blood carcinogen. • Exposure to benzene needs to be evaluated in related chronic diseases. • Cigarette smoke is the main source for indoor benzene exposure. • Health outcomes associated with air pollutants are poorly characterized due to lack of comprehensive monitoring system.

60 APPLIED LIFE SCIENCES↗

A novel role mediated by adenoviral E1A in suppressing cancer through modulating decorin

Oncolytic adenovirus is an emerging alternative to current therapeutics. The adenoviral E1A, the first protein expressed upon oncolytic adenoviral infection, has been identified as an antitumor agent, but the mechanisms of its tumor inhibition ability are unclear enough. Decorin is ubiquitous in the extracellular matrix (ECM), which regulates multiple functions through interaction with ECM. Here, we intended to explore the effects of adenoviral E1A on the tumor extracellular matrix during gene therapy. We demonstrated that reduced decorin expression was found in patients with lung cancer. The adenoviral E1A or a mutant adenoviral E1A with Rb-binding ability absent (E1A 30–60aa, 120–127aa deletion) could increase the expression of decorin and down-regulate VEGF, two members of tumor ECM, involved in both vasculogenesis and angiogenesis. E1A/mE1A-mediated suppressing the migration and invasion ability of tumor cells was depended on decorin. E1A interacted with decorin directly and induced the proteasomal degradation of VEGF. In addition, E1A or mE1A can inhibit tumor growth in a subcutaneous lung cancer xenograft model. It suggested that decorin might be a crucial mediator among ECM components for adenoviral E1A-mediated antitumor activities. These studies on adenovirus E1A provide a new mechanism for the emerging therapies of tumor gene therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human alpha beta hydrolase domain containing protein 11 and its yeast homolog are lipid hydrolases

Mammalian alpha/beta hydrolase domain (ABHD) family of proteins have emerged as key regulators of lipid metabolism and are found to be associated with human diseases. Human α/β-hydrolase domain containing protein 11 (ABHD11) has recently been predicted as a potential biomarker for human lung adenocarcinoma. In silico analyses of the ABHD11 protein sequence revealed the presence of a conserved lipase motif GXSXG. However, the role of ABHD11 in lipid metabolism is not known. To understand the biological function of ABHD11, we heterologously expressed the human ABHD11 in budding yeast, Saccharomyces cerevisiae. In vivo [{sup 14}C]acetate labeling of cellular lipids in yeast cells overexpressing ABHD11 showed a decrease in triacylglycerol content. Overexpression of ABHD11 also alters the molecular species of triacylglycerol in yeast. Similar activity was observed in its yeast homolog, Ygr031w. The role of the conserved lipase motif in the hydrolase activity was proven by the mutation of all conserved amino acid residues of GXSXG motif. Collectively, our results demonstrate that human ABHD11 and its yeast homolog YGR031W have a pivotal role in the lipid metabolism. - Highlights: • Overexpression of ABHD11 protein and its yeast homolog Ygr031w cause a reduction in triacylglycerol levels in yeast. • The reduction in triacylglycerol is due to the presence of lipase motif GXSXG. • Overexpression of ABHD11 and Ygr031w alters the molecular species of triacylglycerol.

60 APPLIED LIFE SCIENCES↗

Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate {sup 125}I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for {approx}4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Influencing Pulmonary Toxicity in Children Undergoing Allogeneic Hematopoietic Stem Cell Transplantation in the Setting of Total Body Irradiation-Based Myeloablative Conditioning

Purpose: This study evaluated factors associated with increased risk of pulmonary toxicity (PT) from any cause in pediatric patients after myeloablative conditioning, using total body irradiation (TBI), followed by allogeneic hematopoietic stem cell transplantation (HSCT). Methods and Materials: The records of 129 consecutive pediatric patients (range: 1-21 years of age) who underwent TBI-based myeloablative conditioning for hematologic malignancies at our institution between January 2003 and May 2014 were reviewed. Although total TBI doses ranged from 10.5 to 14 Gy, lung doses were limited to 10 Gy with partial transmission blocks. TBI dose rates ranged from 5.6 cGy/min to 20.9 cGy/min. PT was classified using clinical symptoms, radiographic evidence, and ventilatory defects on pulmonary function tests. Noninfectious (idiopathic) pneumonia syndrome (IPS) was characterized by patients exhibiting PT while demonstrating no signs of infection throughout the follow-up period. Results: PT from any cause developed in 70.5% of patients and was significantly associated with increased transplantation-related mortality (TRM) (P=.03) and decreased overall survival (OS) (P=.02). IPS developed in 23.3% of patients but was not associated with increased TRM (P=.6) or decreased OS (P=.5). Acute graft-versus-host disease (GVHD) significantly affected PT (P=.001) but did not significantly influence the development of IPS (P=.4). Infection was a leading cause of PT (75.8%). TBI dose rate significantly affected development of overall PT (P=.02) and was the sole factor to significantly influence the incidence of IPS (P=.002). TBI total dose, dose per fraction, disease type, transplantation chemotherapy, age of patient, sex, and donor type did not significantly impact overall PT or IPS. Conclusions: A high incidence of PT was noted in this large series of homogeneously treated pediatric patients undergoing TBI for allogeneic HSCT. TBI dose rates affected overall PT and strongly influenced IPS. TBI dose rate is a contributing factor influencing pulmonary toxicity and rates less than 15 cGy/min should be considered to decrease the risk of IPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ Preservation With Concurrent Chemoradiation for Advanced Laryngeal Cancer: Are We Succeeding?

Purpose: To determine the rates of organ preservation and function in patients with advanced laryngeal and hypopharyngeal carcinomas treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Between April 1999 and September 2005, 82 patients with advanced laryngeal (67%) and hypopharyngeal carcinomas (33%) underwent conventional radiotherapy and concurrent platinum-based chemotherapy with curative intent. Sixty-two patients were male (75.6%). The median age was 59 years. Eighteen patients (22%) were in Stage III and 64 (78%) were in Stage IV. The median radiation dose was 70 Gy. The median potential follow-up was 3.9 years. Results: Overall survival and disease-free survival were respectively 63% and 73% at 3 years. Complete response rate from CRT was 75%. Nineteen patients (23%) experienced significant long-term toxicity after CRT: 6 (7.3%) required a percutaneous endoscopic gastrostomy, 5 (6%) had persistent Grade 2 or 3 dysphagia, 2 (2.4%) had pharyngoesophageal stenosis requiring multiple dilations, 2 (2.4%) had chronic lung aspiration, and 7 (8.5%) required a permanent tracheostomy. Four patients (4.9%) underwent laryngectomy without pathologic evidence of disease. At last follow-up, 5 (6%) patients were still dependent on a gastrostomy. Overall, 42 patients (52%) were alive, in complete response, with a functional larynx and no other major complications. Conclusions: In our institution, CRT for advanced hypopharyngeal and laryngeal carcinoma has provided good overall survival and locoregional control in the majority of patients, but a significant proportion did not benefit from this approach because of either locoregional failure or late complications. Better organ preservation approaches are necessary to improve locoregional control and to reduce long-term toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of temporal dose modulation: Comparison of theory and experiment

Purpose: To compare theoretical predictions and experimental measurements of cell survival after exposure to two different temporally modulated radiation dose patterns that deliver the same dose in the same overall time. Methods: The authors derived an analytic expression for the dose protraction factor G in the Lea-Catcheside formalism for cell survival for 'triangle' and 'V' temporal modulation of dose. These temporal dose patterns were used in experimental clonogenic studies of a melanoma cell line (MM576) and a nonsmall-cell lung cancer line (NCI-H460) that have different alpha, beta, and repair parameters. The overall treatment time and total dose were kept constant. Results: The analytic expressions for G for the two temporal modulations are presented as a function of a single variable, the product of the exposure time, and the repair constant, enabling G to be evaluated for any exposure time and for any cell line. G for the triangle delivery pattern is always the larger. For the MM576 cell line, following a large dose of 6 Gy, a larger survival fraction was found for the V delivery pattern. No difference in survival was observed for lower doses or for the NCI-H460 cell line at any dose. These results are predicted by our theory, using published values of alpha, beta, and repair time within the limits of experimental uncertainty. Conclusions: The study provides evidence to confirm that cell lines having large beta values exhibit a response that is sensitive to the pattern of dose delivery when the delivery time is comparable with the repair time. It is recommended that the dose delivery pattern be considered in hypofractionated treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-J-135: Tumor Displacement-Based Binning for Respiratory-Gated Time-Independent 5DCT Treatment Planning

Purpose: A published 5DCT breathing motion model enables image reconstruction at any user-selected breathing phase, defined by the model as a specific amplitude (v) and rate (f). Generation of reconstructed phase-specific CT scans will be required for time-independent radiation dose distribution simulations. This work answers the question: how many amplitude and rate bins are required to describe the tumor motion with a specific spatial resolution? Methods: 19 lung-cancer patients with 21 tumors were scanned using a free-breathing 5DCT protocol, employing an abdominally positioned pneumatic-bellows breathing surrogate and yielding voxel-specific motion model parameters α and β corresponding to motion as a function of amplitude and rate, respectively. Tumor GTVs were contoured on the first (reference) of 25 successive free-breathing fast helical CT image sets. The tumor displacements were binned into widths of 1mm to 5mm in 1mm steps and the total required number of bins recorded. The simulation evaluated the number of bins needed to encompass 100% of the breathing-amplitude and between the 5th and 95th percentile amplitudes to exclude breathing outliers. Results: The mean respiration-induced tumor motion was 9.90mm ± 7.86mm with a maximum of 25mm. The number of bins required was a strong function of the spatial resolution and varied widely between patients. For example, for 2mm bins, between 1–13 amplitude bins and 1–9 rate bins were required to encompass 100% of the breathing amplitude, while 1–6 amplitude bins and 1–3 rate bins were required to encompass 90% of the breathing amplitude. Conclusion: The strong relationship between number of bins and spatial resolution as well as the large variation between patients implies that time-independent radiation dose distribution simulations should be conducted using patient-specific data and that the breathing conditions will have to be carefully considered. This work will lead to the assessment of the dosimetric impact of binning resolution. This study is supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

Beam geometry selection using sequential beam addition

Purpose: The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. Methods: The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. Results: In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. Conclusions: For situations in which beam geometry has a significant effect on the objective function, SBA can identify arrangements equivalent to equiangular geometries but using fewer beams. Furthermore, SBA provides the value of the objective function as the number of beams is increased, allowing the planner to select the minimal beam number that achieves the clinical goals. The method is simple to implement and could readily be incorporated into an existing optimization system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining multiple models to generate consensus: Application to radiation-induced pneumonitis prediction

The fusion of predictions from disparate models has been used in several fields to obtain a more realistic and robust estimate of the ''ground truth'' by allowing the models to reinforce each other when consensus exists, or, conversely, negate each other when there is no consensus. Fusion has been shown to be most effective when the models have some complementary strengths arising from different approaches. In this work, we fuse the results from four common but methodologically different nonlinear multivariate models (Decision Trees, Neural Networks, Support Vector Machines, Self-Organizing Maps) that were trained to predict radiation-induced pneumonitis risk on a database of 219 lung cancer patients treated with radiotherapy (34 with Grade 2+ postradiotherapy pneumonitis). Each model independently incorporated a small number of features from the available set of dose and nondose patient variables to predict pneumonitis; no two models had all features in common. Fusion was achieved by simple averaging of the predictions for each patient from all four models. Since a model's prediction for a patient can be dependent on the patient training set used to build the model, the average of several different predictions from each model was used in the fusion (predictions were made by repeatedly testing each patient with a model built from different cross-validation training sets that excluded the patient being tested). The area under the receiver operating characteristics curve for the fused cross-validated results was 0.79, with lower variance than the individual component models. From the fusion, five features were extracted as the consensus among all four models in predicting radiation pneumonitis. Arranged in order of importance, the features are (1) chemotherapy; (2) equivalent uniform dose (EUD) for exponent a=1.2 to 3; (3) EUD for a=0.5 to 1.2, lung volume receiving >20-30 Gy; (4) female sex; and (5) squamous cell histology. To facilitate ease of interpretation and prospective use, the fused outcome results for the patients were fitted to a logistic probability function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exercise suppresses tumor growth through epinephrine- and IL-6-dependent mobilization and redistribution of NK cells

Regular exercise reduces the risk of cancer and disease recurrence. Yet the mechanisms behind this protection remain to be elucidated. In this study, tumor-bearing mice randomized to voluntary wheel running showed significant exercise related reduction in tumor incidence and growth across several tumor models including transplantable tumors (Lewis lung and B16 melanoma), chemically (diethylnitrosamine (DEN) induced liver cancer, and a model of spontaneous melanoma (Tg(Grm1)EPv transgenic mice). Microarray analysis revealed exercise-induced up-regulation of pathways associated with immune function, prompting further investigations. NK cell infiltration was significantly increased in tumors from exercising mice, and depletion of NK cells by anti-asialo-GM1 administration increased tumor growth and blunted the exercise-dependent tumor suppression. Mechanistic analyses showed that NK cells were engaged through an epinephrine-dependent mobilization, and blockade of this response by ß-adrenergic blockade blunted the exercise-dependent tumor inhibition. Moreover, exercise-induced IL-6 facilitated redistribution of NK cells to peripheral tissues and induced a shift towards more cytotoxic (CD11b-, CD27+) NK cells at the tumor site. Together these results link exercise, epinephrine and IL-6 to NK cell mobilization and activation, and ultimately to improved control of tumor growth.

60 APPLIED LIFE SCIENCES↗

Alpha5 nicotinic acetylcholine receptor mediates nicotine-induced HIF-1α and VEGF expression in non-small cell lung cancer

By binding to nicotinic acetylcholine receptors (nAChRs), nicotine induces the proliferation and apoptosis of non-small cell lung cancer (NSCLC). Previous studies have indicated that α5-nAChR is highly associated with lung cancer risk and nicotine dependence. However, the mechanisms through which α5-nAChRs may influence lung carcinogenesis are far from clear. In the present study, we investigated the roles of α5-nAChR in the nicotine-induced expression of hypoxia-inducible factor-1α (HIF-1α) and vascular endothelial growth factor (VEGF). Immunohistochemistry was used to detect the expression of α5-nAChR and HIF-1α in 60 specimens of lung cancer and para-carcinoma tissue. The correlations between the expression levels of α5-nAChR and HIF-1α and other clinicopathological data were analyzed. In a cell line that highly expressed α5-nAChR, the loss of α5-nAChR function by siRNA was used to study whether α5-nAChR is involved in the nicotine-induced expression of HIF-1α and VEGF through the activation of the ERK1/2 and PI3K/Akt signaling pathways. Cell growth was detected using the cell counting kit-8 (CCK-8). α5-nAChR (78.3%) and HIF-1α (88.3%) were both overexpressed in NSCLC, and their expression levels were found to be correlated with each other (P < 0.05). In the A549 cell line, α5-nAChR and HIF-1α were found to be expressed under normal conditions, and their expression levels were significantly increased in response to nicotine treatment. The silencing of α5-nAChR significantly inhibited the nicotine-induced cell proliferation compared with the control group and attenuated the nicotine-induced upregulation of HIF-1α and VEGF, and these effects required the cooperation of the ERK1/2 and PI3K/Akt signaling pathways. These results show that the α5-nAChR/HIF-1α/VEGF axis is involved in nicotine-induced tumor cell proliferation, which suggests that α5-nAChR may serve as a potential anticancer target in nicotine-associated lung cancer. - Highlights: • α5-nAChR and HIF-1α over-expressed in NSCLC and correlated with each other. • Nicotine induces cell proliferation and over-expressions of α5-nAChR, HIF-1α and VEGF in NSCLC. • Silence of α5-nAChR inhibited nicotine-induced A549 cell proliferation. • α5-nAChR involved in nicotine-induced HIF-1α and VEGF expression. • Down-regulation of α5-nAChR decreased the phosphorylation level of ERK1/2 and Akt.

60 APPLIED LIFE SCIENCES↗

Design Optimization of Vena Cava Filters: An application to dual filtration devices

Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped model thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.

42 ENGINEERING↗

CSN5/Jab1 facilitates non-small cell lung cancer cell growth through stabilizing survivin

Highlights: • High CSN5 expression is positively correlated with tumor progression and poor survival in NSCLC patients. • Knockdown of CSN5 can suppress NSCLC cells growth by inducing cell cycle arrest and apoptosis promotion. • CSN5 directly interacts with survivin and inhibits its ubiquitination and stabilizes survivin. • The tumor-suppressive effects of CSN5 knockdown in NSCLC cells was partially reversed by upregulation of survivin. CSN5/JAB1 is a critical subunit of the COP9 signalosome (CSN) and is essentially involved in diverse types of cancer, but little is known about the role of CSN5 in non-small cell lung cancer (NSCLC). In the current study, we found that CSN5 expression was higher in NSCLC tissues compared to the corresponding non-tumor tissues. High CSN5 expression level is closely correlated with tumor progression and poor survival in NSCLC patients. We also found that knockdown of CSN5 remarkably suppressed cell growth by inducing cell cycle arrest and apoptosis promotion in NSCLC cells. Mechanistic investigations revealed that CSN5 directly bound survivin and decreased its ubiquitination to enhance the protein stability of survivin. Additionally, our results confirmed that the tumor-promoting effects of CSN5 in NSCLC cells is at least partly through stabilization of survivin. Overall, our data suggested that CSN5 functions as an oncogenic gene in NSCLC, which could be a potential diagnostic and therapeutic target for NSCLC.

60 APPLIED LIFE SCIENCES↗