Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Development of an Ultra-wide band Receiver for the North America Array

The North America Array (NAA), also known as the next-generation Very Large Array (ngVLA), is a concept for a radio astronomical interferometric array operating in the frequency range 1.2 GHz to 116 GHz and designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage while reducing operational costs compared to the current Jansky Very Large Array (JVLA). At JPL, we are designing a single receiver package designed to operate across the 8 to 48 GHz frequency range, in contrast to the current JVLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs. We are developing a prototype integrated feed-receiver package with a system noise temperature that meets the requirements of the ngVLA/NAA primary science programs, with a design that meets the requirement of low long-term operational costs. The receiver package being developed at JPL consists of a feed horn, low-noise amplifier (LNA), and down-converters to analog intermediate frequencies. We report on the status of this receiver package development.

Lazio, Joseph↗

Micromechanical Broadband Infrared Sensors based on Piezoelectric Bending Resonators

There is a high demand for high-performance and low-cost uncooled infrared (IR) detectors. In order to meet this need we are investigating the use of MEMS piezoelectric resonator technology using aluminum nitride (AlN) thin films. Recent research has shown that piezoelectric resonators have the potential to be used as a core element for highly sensitive, low-noise, and low-power uncooled IR detectors. A novel design of an AlN IR sensor based on piezoelectric bending resonator is described and analyzed in this paper. The detector is constructed by using thermally mismatched materials which stress the resonator and shift the resonance frequency. The IR thermal input is sensed by monitoring the frequency shift induced by the in-plan thermal stress. These designs have the potential for very high sensitivity and are compatible with commercially viable CMOS fabrication technology.

Rais-Zadeh, Mina↗

Deep Space Relay Terminals for Mars Superior Conjunction

The Sun periodically blocks direct communication between the Earth and Mars, creating a need for a relay when missions have a critical need for communication during these times. We examined several approaches based on optical or radio-frequency relays placed in deep space between the Earth and Mars, exploring multiple possible placements of relays, including periodic orbits in the Sun-Earth and Sun-Mars rotating frames, and eccentric, sun-centered orbits. L4 and L5 long-period orbits in the sun-Mars system provide suitable communications geometry continuously for very long durations. In such an orbit, a deep space relay terminal with two 50 cm optical telescopes and two 75 cm Ka-band dish antennas, along with associated receivers and transmitters, would be capable of supporting Mars superior conjunctions with an optical data rate of 28 to 44 Mbps for return links, and 30-36 Mbps in the forward direction. The relay should use efficient, low-noise optical detectors, such as appropriately cooled Avalanche Photo Diode or Superconducting Nanowire Single Photon Detectors, to achieve these data rates. The single relay discussed in this study might have additional value beyond communications, providing a synergistic platform for solar observation, solar wind observation, gravitational studies, the search for near-earth asteroids, or a navigational beacon.

Lau, Chi-Wung↗

WFIRST Coronagraph Detector Trap Modeling Results and Improvements

The WFIRST coronagraph is being designed to detect and characterize mature exoplanets through the starlight reflected from their surfaces and atmospheres. The light incident on the detector from these distant exoplanets is estimated to be on the order of a few photons per pixel per hour. To measure such small signals, the project has baselined the CCD201 detector made by e2v, a low-noise and high-efficiency electron-multiplying charge-coupled device (EMCCD), and has instituted a rigorous test and modeling program to characterize the device prior to flight. An important consideration is detector performance degradation over the proposed mission lifetime due to radiation exposure in space. To quantify this estimated loss in performance, the project has built a detector trap model that takes into account detailed trap interactions at the sub-pixel level, including stochastic trap capture and release, and the deferment of charge into subsequent pixels during parallel and serial clocking of the pseudo-two-phase CCD201 device. This paper describes recent detector trap model improvements and modeling results.

Holland, Andrew↗

The Canadian Galactic Emission Mapper (CGEM) A Cosmic Microwave Foreground Experiment

The Canadian Galactic Emission Mapper (CGEM) is a 4-meter single-dish radio telescope located at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, Canada. CGEM is designed to map polarized Galactic synchrotron emission across the entire northern sky at 8-10 GHz with 1 MHz frequency resolution and ∼ 0.5 degree angular resolution. Its goal is to obtain high-fidelity, low-noise maps of polarized Galactic synchrotron radiation, at frequencies where synchrotron dominates, in order to provide a reliable template for CMB B−mode foreground cleaning. We will show on sky performance of CGEM’s single-pixel azimuthally-symmetric telescope, its coherent, dual-polarized radiometer, and show maps made from commissioning data from the first few months of operation.

Cosmic microwave background↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

SPT-3G D1: Compton-$y$ maps using data from the SPT-3G and Planck surveys

We present thermal Sunyaev-Zel'dovich (tSZ) Compton-$y$ parameter maps constructed from two years (2019-2020) of observations with the South Pole Telescope (SPT) third-generation camera, SPT-3G, combined with data from the Planck satellite. Using a linear combination (LC) pipeline, we obtain a suite of reconstructions that explore different trade-offs between statistical sensitivity and suppression of astrophysical contaminants, including minimum-variance, CMB-deprojected, and CIB-deprojected $y$-maps. We validate these maps through different statistical techniques such as auto- and cross-power spectra with large-scale structure tracers as well as stacking on cluster locations. These tests are used to understand the balance between noise and astrophysical foreground residuals (such as the CIB) in combination with the recovery of the tSZ signal for different maps. For example, results from stacking at the location of clusters confirm the robustness of the recovered tSZ signal over the $\sim 1500\: {\rm deg}^2$ SPT-3G survey field used in this analysis. The high-resolution and low-noise maps produced here provide an important cosmological tool for future studies, including measurements of the Compton-$y$ map power spectrum, cross-correlations with other tracers of the large-scale structure, detailed modeling of cluster pressure profiles, and study of the thermodynamic state of the baryons in the Universe.

Maniyar, A. S. [Harvard-Smithsonian Ctr. Astrophys↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Alcock-Paczynski Blinding Scheme for the Ly-$α$ Forest Analysis

We present and validate a blinding method for the Lyman-$α$ (Ly$α$) forest analysis based on a modification of the Alcock-Paczynski test. In order to hide the background expansion history, the method employs a geometrical shift of each quasar (QSO) forest in wavelength space, once the quasar continuum has been fitted and the fluctuation field is extracted. The redshift positions for the QSO sample are also changed in a consistent manner. We show that the method remains effective when applied to real data, where contamination from metals and Lyman-$β$ is intrinsically mixed with the Lyman-$α$ forest. This limitation is primarily visible in the 1D correlation function, where other blinding strategies can mitigate the effect. To assess its effectiveness, the prescription is tested against a series of datasets of increasing complexity: from idealized low-noise mocks, to realistic DESI year one synthetic datasets, and finally to data from DESI first data release (DR1), using both the auto (Ly$α\times$Ly$α$) and cross (Ly$α\times$ QSO) correlations. We find that the method robustly shifts the BAO peak position from the 3D correlation functions to the expected value for cosmology changes of around 5% in the matter content, without altering the shape of the posteriors in the model parameters. In conclusion, this catalog-level blinding strategy is a viable method for cosmological inference with the Lyman-$α$ forest, particularly if a cross-analysis with other tracers using the same blinding strategy is pursued.

Perez-Sanchez, G. [Guanajuato U.] (ORCID:000900096↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Cryogenic MMIC Low Noise Amplifiers

Monolithic (MMIC) and discrete transistor (MIC) low noise amplifiers are compared on the basis of performance, cost, and reliability. The need for cryogenic LNA's for future large microwave arrays for radio astronomy is briefly discussed and data is presented on a prototype LNA for the 1 to 10 GZH range along with a very wideband LNA for the 1 to 60 GHz range.

MMIC Low-noise amplifier↗

Recent progress in opto-electronic oscillator

The optoelectronic oscillator (OEO) is a unique device based on photonics techniques to generate highly spectrally pure microwave signals [1]. The development of the OEO was motivated by the need for high performance oscillators in the frequency range larger than 10 GHz, where conventional electronic oscillators have a number of limitations. These limitations typically stem from the product of fQ, where f is the oscillator frequency and Q is the quality factor of the resonator in the oscillator. In conventional resonators, whether electromagnetic or piezoelectric, this product is usually a constant. Thus, as the oscillator frequency is pushed higher, the quality factor degrades, resulting in degradation of the phase noise of the oscillator. An approach to mitigate the problem is to start with a very high quality signal in the 5 to 100 MHz range generated by a quartz oscillator and multiply the frequency to achieve the desired microwave signal. Here again, frequency multiplication also results in an increase of the phase noise by a factor of 2010gN, where N is the multiplication factor.

opto-electronic oscillators↗

W-band Heterodyne Receiver Module with 27 K Noise Temperature

We present noise temperature and gain measurements of a W-band heterodyne module populated with MMIC LNAs designed and fabricated using 35nm InP HEMT process. The module has a WR-10 waveguide input. GPPO connectors are used for the LO input and the I and and Q IF outputs. The module is tested at both ambient (300 K) and cryogenic (25 K) temperatures. At 25 K physical temperature, the module has a noise temperature in the range of 27-45 K over the frequency band of 75-111 GHz. The module gain varies between 15 dB and 27 dB. The band-averaged module noise temperature of 350 K and 33 K were measured over 80-110 GHz for the physical temperature of 300 K and 25 K, respectively. The resulting cooling factor is 10.6.

heterodyne module↗