Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Individual Differences in the Temporal Profile of Cardiovascular Responses to Head Down Tilt and Orthostatic Stress with and Without Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. Hypo-volemia is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore loss fluid volume by giving crew salt tablets and water prior to re-entry. Eight men and eight women will be tested during two, 6-hour exposures to 6o HDT: 1) fluid loading, 2) no fluid loading. Before and immediately after each HDT, subjects will perform a stand test to assess their orthostatic tolerance. Physiological measures (e.g., ECG, blood pressure, peripheral blood volume) will be continuously monitored while echocardiography measures are recorded at 30-minute intervals during HDT and stand tests. Preliminary results (N=4) clearly show individual differences in responses to this countermeasure and the time course of physiological changes induced by HDT.

Cowings, Patricia↗

Comparative Study of Vibration Condition Indicators for Detecting Cracks in Spur Gears

This paper reports the results of an empirical study on the tooth breakage failure mode in spur gears. Of four dominant gear failure modes (breakage, wear, pitting, and scoring), tooth breakage is the most precipitous and often leads to catastrophic failures. The cracks were initiated using a fatigue tester and a custom-designed single-tooth bending fixture to simulate over-load conditions, instead of traditional notching using wire electrical discharge machining (EDM). The cracks were then propagated on a dynamometer. The ground truth of damage level during crack propagation was monitored with crack-propagation sensors. Ten crack propagations have been performed to compare the existing condition indicators (CIs) with respect to their: ability to detect a crack, ability to assess the damage, and sensitivity to sensor placement. Of more than thirty computed CIs, this paper compares five commonly used: raw RMS, FM0, NA4, raw kurtosis, and NP4. The performance of combined CIs was also investigated, using linear, logistic, and boosted regression trees based feature fusion.

Nanadic, Nenad↗

Task Load Management in Earth Independent Medical Operations

BACKGROUND: Medical care in spaceflight carries a high task load and can easily overwhelm a small crew. Present day operations in low Earth orbit (LEO) offload most medical tasks to ground teams in mission control. This team includes dozens of flight surgeons, specialists, and engineers and supports the on-orbit crew in monitoring environmental systems, tracking medications, guiding procedures, providing expert advice, and many other tasks. However, the physical limitations of the speed of light and technical limitations of bandwidth, channel capacity, and signal processing mean that missions beyond LEO cannot rely on this level of telemedical support. The further we travel from Earth the more these tasks will fall on the shoulders of the crew and the greater the risk of task saturation to the wellbeing of the crew and the success of the mission. Exploration class space crews will need progressively more robust systems for managing task load as they progress further out in space. OVERVIEW: Medical task management systems will need to assist with two broad categories of tasks; cognitively intensive tasks and procedure execution tasks. In both cases the goal is for the systems to operate in the background with minimal human-in-the-loop intervention. To accomplish this such systems will need to be designed with careful consideration for human factors and human systems integration to maximize efficiency, minimize alarm fatigue, and avoid inadvertently increasing task loads. Finally, the key domains of space medicine tasking can be used to map present day and near future technologies to the areas where they are best suited to support and identify gaps which can be targeted for research and development. DISCUSSION: Task load is a major challenge for Earth Independent Medical Operations to overcome. It will require careful coordination between experts in a variety of fields paying attention to human factors and human systems integration as well as technical and medical expertise. If done well medical task management systems can handle many of the tasks currently run by humans in mission control and enable human crews to maintain terrestrial standards of care in the extraterrestrial environment.

Dana Levin↗

James Webb Space Telescope Integrated Science Instrument Module Thermal Vacuum Thermal Balance Test Campaign at NASA's Goddard Space Flight Center

The James Webb Space Telescope is a large infrared telescope with a 6.5-meter primary mirror, designed as a successor to the Hubble Space Telescope when launched in 2018. Three of the four science instruments contained within the Integrated Science Instrument Module (ISIM) are passively cooled to their operational temperature range of 36K to 40K with radiators, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. Thermal-vacuum testing of the flight science instruments at the ISIM element level has taken place in three separate highly challenging and extremely complex thermal tests within a gaseous helium-cooled shroud inside Goddard Space Flight Centers Space Environment Simulator. Special data acquisition software was developed for these tests to monitor over 1700 flight and test sensor measurements, track over 50 gradients, component rates, and temperature limits in real time against defined constraints and limitations, and guide the complex transition from ambient to final cryogenic temperatures and back. This extremely flexible system has proven highly successful in safeguarding the nearly $2B science payload during the 3.5-month-long thermal tests. Heat flow measurement instrumentation, or Q-meters, were also specially developed for these tests. These devices provide thermal boundaries o the flight hardware while measuring instrument heat loads up to 600 mW with an estimated uncertainty of 2 mW in test, enabling accurate thermal model correlation, hardware design validation, and workmanship verification. The high accuracy heat load measurements provided first evidence of a potentially serious hardware design issue that was subsequently corrected. This paper provides an overview of the ISIM-level thermal-vacuum tests and thermal objectives; explains the thermal test configuration and thermal balances; describes special measurement instrumentation and monitoring and control software; presents key test thermal results; lists problems encountered during testing and lessons learned.

JWST ISIM Thermal↗

A Fast Monte Carlo Method for Model-Based Prognostics Based on Stochastic Calculus

This work proposes a fast Monte Carlo method to solve differential equations utilized in model-based prognostics. The methodology is derived from the theory of stochastic calculus, and the goal of such a method is to speed up the estimation of the probability density functions describing the independent variable evolution over time. In the prognostic scenarios presented in this paper, the stochastic differential equations describe variables directly or indirectly related to the degradation of a monitored system. The method allows the estimation of the probability density functions by solving the deterministic equation and approximating the stochastic integrals using samples of the model noise. By so doing, the prognostic problem is solved without the Monte Carlo simulation based on Euler's forward method, which is typically the most time consuming task of the prediction stage. Three different prognostic scenarios are presented as proof of concept: (i) life prediction of electrolytic capacitors, (ii) remaining time to discharge of Lithium-ion batteries, and (iii) prognostic of cracked structures under fatigue loading. The paper shows how the method produces probability density functions that are statistically indistinguishable from the distributions estimated with Euler's forward Monte Carlo simulation. However, the proposed solution is orders of magnitude faster when computing the time-to-failure distribution of the monitored system. The approach may enable complex real-time prognostics and health management solutions with limited computing power.

Corbetta, M.↗

A Fast Monte Carlo Method for Model-Based Prognostics Based on Stochastic Calculus

This work proposes a fast Monte Carlo method to solve differential equations utilized in model-based prognostics. The methodology is derived from the theory of stochastic calculus, and the goal of such a method is to speed up the estimation of the probability density functions describing the independent variable evolution over time. In the prognostic scenarios presented in this paper, the stochastic differential equations describe variables directly or indirectly related to the degradation of a monitored system. The method allows the estimation of the probability density functions by solving the deterministic equation and approximating the stochastic integrals using samples of the model noise. By so doing, the prognostic problem is solved without the Monte Carlo simulation based on Euler's forward method, which is typically the most time consuming task of the prediction stage. Three different prognostic scenarios are presented as proof of concept: (i) life prediction of electrolytic capacitors, (ii) remaining time to discharge of Lithium-ion batteries, and (iii) prognostic of cracked structures under fatigue loading. The paper shows how the method produces probability density functions that are statistically indistinguishable from the distributions estimated with Euler's forward Monte Carlo simulation. However, the proposed solution is orders of magnitude faster when computing the time-to-failure distribution of the monitored system. The approach may enable complex real-time prognostics and health management solutions with limited computing power.

stochastic calculus↗

Message Mode Operations for Spacecraft: A Proposal for Operating Spacecraft During Cruise and Mitigating the Network Loading Crunch

The NASA Deep Space Network (DSN) is a world-class spacecraft tracking facility with stations located in Spain, Australia and USA, servicing Deep Space Missions of many space agencies. The current system of scheduling spacecraft during cruise for multiple 8 hour tracking sessions per week currently leads to an overcommitted DSN. Studies indicate that future projected mission demands upon the Network will only make the loading problem worse. Therefore, a more efficient scheduling of DSN resources is necessary in order to support the additional network loading envisioned in the next few years: The number of missions is projected to increase from 25 in 1998 to 34 by 2001. In fact given the challenge of the NASA administrator, Dan Goldin, of launching 12 spacecraft per year, the DSN would be tracking approximately 90 spacecraft by 2010. Currently a large amount of antenna time and network resources are subscribed by a project in order to have their mission supported during the cruise phase. The recently completed Mars Pathfinder mission was tracked 3 times a week (8 hours/day) during the majority of its cruise to Mars. This paper proposes an innovative approach called Message Mode Operations (MMO) for mitigating the Network loading problem while continuing to meet the tracking, reporting, time management, and scheduling requirements of these missions during Cruise while occupying very short tracking times. MMO satisfies these requirements by providing the following services: Spacecraft Health and Welfare Monitoring Service Command Delivery Service Adaptive Spacecraft Scheduling Service Orbit Determination Service Time Calibration Service Utilizing more efficient engineering telemetry summarization and filtering techniques on-board the spacecraft and collapsing the navigation requirements for Doppler and Range into shorter tracks, we believe spacecraft can be adequately serviced using short 10 to 30 minute tracking sessions. This claim assumes that certain changes would have to he made in the way the Network traditionally services missions in Cruise. Furthermore, limiting spacecraft to short sessions will free up larger blocks of time in the tracking schedule to help accommodate future tracking demands soon to be placed upon the Network. This paper describes the key characteristics and benefits of MMO, the operational scenarios for its use, the required changes to the ground system in order to make this approach feasible and the results of two simulations: 1) to determine the effects of MMO on projected mission loading on the DSN and, 2) to determine the effect MMO has on spacecraft orbit determination.

Greenberg, Ed↗

Resistor monitors transfer of liquid helium

Large resistance change of a carbon resistor at the liquid helium temperature distinguishes between the transfer of liquid helium and gaseous helium into a closed Dewar. The resistor should be physically as small as possible to reduce the heat load to the helium.

Hesketh, W. D.↗

Cyclic debonding of unidirectional composite bonded to aluminum sheet for constant-amplitude loading

Cyclic debonding rates were measured during constant-amplitude loading of specimens made of graphite/epoxy bonded to aluminum and S-glass/epoxy bonded to aluminum. Both room-temperature and elevated-temperature curing adhesives were used. Debonding was monitored with a photoelastic coating technique. The debonding rates were compared with three expressions for strain-energy release rate calculated in terms of the maximum stress, stress range, or a combination of the two. The debonding rates were influenced by both adherent thickness and the cyclic stress ratio. For a given value of maximum stress, lower stress ratios and thicker specimens produced faster debonding. Microscopic examination of the debonded surfaces showed different failure mechanisms both for identical adherends bonded with different adhesive and, indeed, even for different adherends bonded with identical adhesives. The expressions for strain-energy release rate correlated the data for different specimen thicknesses and stress ratios quite well for each material system, but the form of the best correlating expression varied among material systems. Empirical correlating expressions applicable to one material system may not be appropriate for another system.

Roderick, G. L.↗

Characterization of Mode I and mixed-mode delamination growth in T300/5208 graphite/epoxy

The roles played by Mode I and Mode II strain-energy release rates (G-I and G-II, respectively) in inducing delamination growth under static and fatigue loading were investigated, using T300/5208 graphite/epoxy specimens. Double cantilever beam (DCB) specimens and cracked lap shear (CLS) specimens were used for pure Mode I and mixed-mode tests, respectively. Fatigue-induced delamination growth was characterized by constant-amplitude fatigue tests at a minimum to maximum cyclic load ratio of 0.05 and a frequency of 10 Hz. During the tests, the maximum and minimum strain-energy release rates (Gmax, Gmin) and the delamination growth rate (da/dN) were monitored. Static tests on mixed-mode CLS specimens measured the total strain-energy release rate, which was broken into G-I and G-II components using finite-element analysis. A power-law relationship between da/dN and G-Imax, and da/dN and Gmax were obtained from fatigue test results on DCB and CLS specimens, respectively. The power law for a pure Mode II delamination was derived from CLS results by subtracting the contribution due to G-I.

Ramkumar, R. L.↗

Thermoelastic Stress Analysis: An NDE Tool for the Residual Stress Assessment of Metallic Alloys

During manufacturing, certain propulsion components that will be used in a cyclic fatigue environment are fabricated to contain compressive residual stresses on their surfaces because these stresses inhibit the nucleation of cracks. Overloads and elevated temperature excursions cause the induced residual stresses to dissipate while the component is still in service, lowering its resistance to crack initiation. Research at the NASA Glenn Research Center at Lewis Field has focused on employing the Thermoelastic Stress Analysis technique (TSA, also recognized as SPATE: Stress Pattern Analysis by Thermal Emission) as a tool for monitoring the residual stress state of propulsion components. TSA is based on the fact that materials experience small temperature changes when they are compressed or expanded. When a structure is cyclically loaded (i.e., cyclically compressed and expanded), the resulting surface-temperature profile correlates to the stress state of the structure s surface. The surface-temperature variations resulting from a cyclic load are measured with an infrared camera. Traditionally, the temperature amplitude of a TSA signal has been theoretically defined to be linearly dependent on the cyclic stress amplitude. As a result, the temperature amplitude resulting from an applied cyclic stress was assumed to be independent of the cyclic mean stress.

Gyekenyesi, Andrew L.↗

Advanced Neutron Spectrometer

Energetic neutron measurements remain a challenge for space science investigations and radiation monitoring for human exploration beyond LEO. We are investigating a new composite scintillator design that uses Li6 glass scintillator embedded in a PVT block. A comparison between Li6 and Boron 10 loaded scintillators are being studied to assess the advantages and shortcomings of these two techniques. We present the details of the new Li6 design and results from the comparison of the B10 and Li6 techniques during exposures in a mixed radiation field produced by high energy protons interacting in a target material.

Christl, Mark↗

Designing an Exploration Atmosphere Prebreathe Protocol

Extravehicular activities (EVAs) at remote locations must maximize limited resources such as oxygen (O2) and also minimize the risk of decompression sickness (DCS). A proposed remote denitrogenation (prebreathe) protocol requires astronauts to live in a mildly hypoxic atmosphere at 8.2 psia while periodically performing EVAs at 4.3 psia. Empirical data are required to confirm that the protocol meets the current accept requirements: less than or equal to 15% incidence of Type I DCS, less than or equal to 20% incidence of Grade IV venous gas emboli (VGE), both at 95% statistical confidence, with no Type II DCS symptom during the validation trial. METHODS: A repeated measures statistical design is proposed in which groups of 6 subjects with physical characteristics similar to active-duty astronauts would first become equilibrated to an 8.2 psia atmosphere in a hypobaric chamber containing 34% O2 and 66% N2, over 48 h, and then perform 4 simulated EVAs at 4.3 psia over the next 9 days. In the equilibration phase, subjects undergo a 3-h 100% O2 mask prebreathe prior to and during a 5-min ascent to 8.2 psia to prevent significant tissue N2 supersaturation on reaching 8.2 psia. Masks would be removed once 34% O2 is established at 8.2 psia, and subjects would then equilibrate to this atmosphere for 48 h. The hypoxia is equivalent to breathing air at 1,220 meters (4,000 ft) altitude, just as was experienced in the shuttle 10.2 psia - 26.5% O2 staged denitrogenation protocol and the current ISS campout denitrogenation protocol. For simulated EVAs, each subject dons a mask and breathes 85% O2 and 15% N2 during a 3-min depressurization to 6.0 psia, holds for 15 min, and then completes a 3-min depressurization to 4.3 psia. The simulated EVA period starts when 6.0 psia is reached and continues for a total of 240 min (222 min at 4.3 psia). During this time, subjects will follow a prescribed repetitive activity against loads in the upper and lower body with mean metabolic rate approaching 1500 BTU/hr [378 kcal/hr (O2 consumption about 1.3 l(sub STPD)/min)] in ambulatory subjects. Noninvasive Doppler ultrasound bubble monitoring for VGE in the pulmonary artery will be performed on subjects by 2 Doppler Technicians at about 15 min intervals while at 4.3 psia. At the end of this period, a 15-min repressurization returns all subjects back to 8.2 psia and the cycle is repeated 3 additional times with a day of rest between simulated EVAs. RESULTS: With an assumed 1.5% probability of DCS [P(DCS)] and accounting for within-subject correlation, running the proposed study with 20 subjects has a 95% probability of meeting the accept criterion for DCS. But if the true probability of DCS is 3.0%, then 30 subjects would be needed to achieve about the same probability to meet our accept criterion. These results assume a standard deviation of 1.4 for the between-subjects random component of P(DCS) on a logit scale, which was estimated from a previous study.

Conkin, Johnny↗

The Diurnal Variation of Dust and Water Ice Aerosol Optical Depth at Jezero Crater Observed By MEDA/TIRS Over A Full Martian Year

The Thermal InfraRed Sensor (TIRS) on the Perseverance rover has provided nearly two full Mars years of systematic monitoring of the total aerosol optical depth above Jezero Crater. These observations span a wide range of timescales, capturing seasonal patterns, diurnal variations, and minute-to-minute fluctuations in aerosol loading. By combining TIRS retrievals with orbital observations, the relative contributions of dust and water ice aerosols can be estimated, revealing their different seasonal and diurnal behaviors. The TIRS record shows distinct periods of dust storm activity, including strong regional storms during the perihelion season as well as short lived but intense dust events outside the typical dust storm season. Water ice clouds exhibit pronounced seasonal and diurnal variability, with peak activity occurring during the aphelion season but with a presence throughout the year. The diurnal variation of clouds differs significantly between the aphelion and perihelion seasons, with clouds persisting throughout the night during the aphelion season, while largely absent outside of specific periods after sunrise and sunset during the perihelion season. These results provide new insights into the complex behavior of aerosols at Jezero Crater and their connections to atmospheric dynamics and the Martian dust and water cycles.

Michael D Smith↗

Trustworthy Machine Learning for Damage Identification in Composites

A challenging opportunity in structural health monitoring of composite materials is using machine learning (ML) methods to classify acoustic emissions (AE) according to the damage mechanism that emitted the signal. Although a wide variety of ML frameworks have been developed, there is a distinct lack of ground truth datasets which has precluded any direct assessment of their accuracy. Here, we present a novel ground truth dataset gathered on simplified unidirectional SiC/SiC composite structures. Herein, AE is collected from minicomposites which are loaded to targeted percentages of the ultimate tensile stress. These minicomposites are then volumetrically imaged with XCT and individual damage events, along with the mechanism, are correlated to AE. We explore the signal features that allow for mechanism discrimination, along with the feasibility of both unsupervised and supervised frameworks for use in the online monitoring of composite structures.

Machine learning, acoustic emission, ceramic matri↗

Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses

Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project. Published by Elsevier Ltd on behalf of COSPAR.

NASA Center KSC↗

Tug and payload-to-Orbiter interface requirements

This paper presents results of a study to identify, evaluate, and develop Tug plus payload-to-Orbiter accommodation requirements. Interface areas include structural, mechanical, fluids, environmental, avionics, and safety. Each interface area was investigated to determine the best physical and operational method of accomplishing the required functions with an overriding goal of establishing sample and flexible interface requirements suitable for Tug, Tug payloads, and other cargo. The recommended system for supporting the Tug and its payload from the Orbiter employs a cylindrical load-carrying structure called a deployment adapter that has a rotational capability for Tug deployment. The design and operation of the deployment adapter and other peripheral interface equipment such as crew compartment monitor and control panels and cargo bay fluid and electrical interface panels are discussed.

Bock, E. H.↗

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗