Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Reliability Improvement by Fault-Tolerant Operation of NPC Inverter for Motor Driving

The high-reliability operation of three-level inverters is crucial to prevent equipment damage, process downtime, and economic losses. This article investigates a three-level neutral-point-clamped inverter under all possible combinations of open-circuit and short-circuit faults and proposes a new postfault operation method without adding extra hardware. This method provides comprehensive solution for operations after single and multiple-device failures, increasing the inverter reliability by 24%. This article classified postfault modulations and uncovered previously unknown fault scenarios that can be addressed using the proposed control method. A new postfault modulation based on space vector modulation with virtual vectors is proposed. The feasibility of the proposed control method is verified by simulation and an experiment for one fault scenario in a three-level neutral-point-clamped inverter with a 3.73 kW motor load. Furthermore, this article contributes to improving the reliability of three-level inverters.

42 ENGINEERING↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Material Plasma Exposure eXperiment (MPEX) High Heat Flux Bellows for Component Alignment in High Microwave Environment

The Material Plasma Exposure eXperiment (MPEX) device is a linear plasma device developed to perform plasma material interaction experiments under the conditions prototypic of a fusion reactor divertor. MPEX has multiple systems that must be precisely aligned to the plasma axis, including an electron cyclotron heating system that emits up to 400 kW of microwave power into the vacuum vessel. Five distinct systems require precise alignment on the MPEX device, thus requiring four bellows, all of which are adjacent to the plasma at a relatively high heat flux of approximately 47 kW/m2 and microwave power regions. The MPEX high heat flux bellows (HHFB) is designed to deliver 6 degrees of freedom positioning. The HHFB includes titanium–zirconium–molybdenum (TZM) inserts that are brazed into a Glidcop AL-15 body using a high-temperature braze alloy, thus blocking direct line of sight to an edge-welded bellows from the plasma and microwave screen to block microwaves from the bellows. Further, a custom ConFlat knife edge is machined into the Glidcop AL-15, so the vacuum flanges do not need a braze or weld joint on the vacuum interface. Fingerstock or copper mesh is used to restrict microwave power from entering the interstitial space between the water-cooled Glidcop AL-15 body and edge-welded bellows. Glidcop AL-15 was selected as the material of choice for the water-cooled body because it can maintain mechanical integrity at elevated temperatures, and it also allows for a high-temperature braze. TZM was selected for its machinability and compatibility with vacuum and plasma requirements. A test article is also being considered for a similarly shaped component, the MPEX limiter, that will demonstrate the integrity of the braze joint under high thermal load. Results from this testing will be extrapolated to deduce the lifetime and integrity of the HHFB design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Materials for Radio Frequency Antenna Plasma Facing Components

Here, the interaction of radio frequency (RF) sheaths with fusion reactor relevant materials (e.g., tungsten and titanium diboride) is being studied on the RF Plasma Interaction Experiment (RF PIE). The RF PIE consists of an electron cyclotron resonance (ECR) plasma source (2.45 GHz, 5 kW) with a biased and heated RF electrode that is used to simulate antenna surfaces in contact with the edge plasma. Helium plasmas (density of ~1e18/m 3 , electron temperature of 4–5 eV) are being used to explore sheath formation on material surfaces with biases up to 500 V. The erosion of a tungsten surface is being studied spectroscopically using a mirror-linked 1 m Czerny-Turner UV imaging spectrometer with a spectral resolution of 0.012 nm for measuring plasma emission in and near the sheath. Tungsten line emission intensity is higher for RF versus dc biasing for similar plasma conditions and average ion energy. RF biasing causes a broadening of the ion energy distribution function (IEDF) due to the RF sheath, as determined from the hPIC2 code, and results in enhanced sputtering. Calculations of the expected sputtering yield for dc and RF biasing are consistent with experimental observations of changes in the 400.9 nm tungsten line emission intensity as a function of ion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Virtual Critical Coupling in High-Power Resonant Systems

Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting per- formance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). Furthermore, the results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Estimating Fast Charging Infrastructure Requirements to Fully Electrify Ride-Hailing Fleets Across the United States

Ride-hailing electrification is made challenging by a variety of factors, including limited driver access to overnight charging and a nascent network of public direct-current fast charging (DCFC). This article projects the DCFC infrastructure needed to electrify ride-hailing across 384 cities in the United States. Research leveraging a novel infrastructure projection tool, Electric Vehicle Infrastructure Tool for On-Demand Mobility Services model (EVI-OnDemand), estimates that 25,400 DCFC ports capable of charging vehicles at a mean power of 150 kW are required to electrify 1.45 million ride-hailing vehicles in the baseline scenario. Results show that ride-hailing vehicles require 17.5 DCFC ports per 1000 vehicles, three times that of personal electric vehicles (EVs). Infrastructure demand is also shown to vary across cities; 63% more DCFC ports are needed to support 1000 battery EVs in Chicago versus Miami. The analysis also includes sensitivity studies that explore variation in charging demand across input assumptions, finding that charging power, vehicle class, overnight charging access rates, and port utilization influence the network size needed. Projections vary from 18,600 to 41,300 DCFC ports across sensitivity scenarios, indicating that ride-hailing electrification will require significant expansion of access to fast charging even in the most optimistic scenarios, and investments into supporting assets can reduce the scale of the public charging expansion needed.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity Analysis of a Polyphase Wireless Power Transfer System under Off-Nominal Conditions

Misaligned and/or variable coil airgaps cause coupling coefficient variation in wireless power transfer (WPT) systems, resulting in a decrease in the system’s transmitted power and efficiency. This paper presents sensitivity analyses of a three-phase, Y-Y connected, series-tuned WPT system in the frequency domain in terms of several different electric vehicle wireless charging off-nominal conditions (misalignments in Δ x and Δ y directions, change of airgap Δ z , and the roll Δψ, pitch Δθ, and yaw ΔΦ angles) as specified in Society of Automotive Engineers (SAE) J2954 Standard. Coil inductance matrices were obtained by measuring the self- and mutual inductances of the primary and secondary coil phase windings at variable airgap classes (from 5 cm to 30 cm) for five different charging positions as identified in SAE J2954. These 6 × 6 inductance matrices were used in sensitivity and Plexim/PLECS simulation analyses. The sensitivity of the WPT system was analyzed analytically using the input impedance and phase angle, voltage gain, current gain, quality factor, and coupling coefficient parameters of the series-tuned WPT system. The results were confirmed experimentally on a 50 kW WPT system.

42 ENGINEERING↗

Fourier Analysis and Loss Modeling for Inductive Wireless Electric Vehicle Charging with Reduced Stray Field

With the growth of electric vehicle (EV) popularity, different charging options to increase user convenience and reduce charging times are being considered and researched. Among these, inductive wireless power transfer (WPT) systems for EVs are being designed to meet specifications such as stray field, power level, efficiency, misalignment tolerance, and ground clearance, which are all heavily influenced by the coil geometry. The proposed Fourier Analysis Method (FAM) is an analytical method to directly design coil geometries to meet stray field and power level requirements through an optimization of Fourier basis function coefficients. The outputs of the optimization are complex, planar coil geometries that meet the power level and stray field constraints with minimized loss factors. Contours of these potentials determine the coil conductor paths and loss models predict the system efficiency and performance over misalignment. The Fourier representation of the geometry is used to conveniently calculate the coupling over misalignment, external proximity effect loss, and ferrite loss. A 6.6 kW prototype WPT system with low stray field and high efficiency is built from the optimization results to validate the models and showcase the usefulness of the FAM design approach.

33 ADVANCED PROPULSION SYSTEMS↗

Atmospheric plasma spraying to fabricate metal‐supported solid oxide fuel cells with open‐channel porous metal support

Abstract Metal‐supported solid oxide fuel cells (MS‐SOFCs) have been fabricated by applying phase‐inversion tape‐casting and atmospheric plasma spraying (APS). The effect of the binder amount of the phase‐inversion slurries on the microstructure development of the 430L stainless steel metal support was investigated. The pore structures, the viscosity of the slurry, porosity and permeability of the as‐prepared metal supports are significantly influenced by the amount of the binder. NiO–scandia‐stabilized zirconia (ScSZ) anode, ScSZ electrolyte and La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3−δ (LSCF) cathode layers were consecutively deposited on the metal support with an ideal microstructure by APS process. The effect of plasma power of the APS on the microstructure of the electrolyte and cathode was investigated. A dense electrolyte layer and a porous cathode layer were successfully obtained at 40 and 6 kW of the APS plasma power, respectively. MS‐SOFCs, with a cell configuration of 430L/Ni‐ScSZ/ScSZ/LSCF, achieved a maximum cell power density of 1079 mW cm −2 at 700°C using humidified H 2 as fuel and ambient air as oxidant. The corresponding ohmic resistance and total resistance of MS‐SOFCs was 0.14 and 0.32 Ω cm 2 , respectively. This work demonstrates the feasibility of fabricating high‐performance MS‐SOFCs with economical and scalable techniques.

36 MATERIALS SCIENCE↗

Optimization of a Cyclone Using Multiphase Flow Computational Fluid Dynamics

The U.S. Department of Energy National Energy Technology Laboratory's (NETL) 50 kW th chemical looping reactor (CLR) has an underperforming cyclone, which was designed using empirical correlations. To improve the performance of this cyclone using computational fluid dynamics (CFD)-based modeling simulations, four critical design parameters including the vortex tube radius and length, barrel radius, and the inlet width and height were optimized. Here, NETL's open source multiphase flow with interphase exchange (MFiX) CFD code has been used to model a series of cyclones by systematically varying the geometric design parameters. To perform the optimization process, the surrogate modeling and sensitivity analysis followed by the optimization capability in nodeworks was used. The basic methodology for the process is to employ a statistical design of experiments (DOE) method to generate sampling simulations that fill the design space. Corresponding CFD models are then created, executed, and postprocessed. A response surface is created to characterize the relationship between input parameters and the quantities of interest (QoI). Finally, the CFD-surrogate is used by an optimization method to find the optimal design condition based on the objective and constraints prescribed. The resulting optimal cyclone has a larger diameter and longer vortex tube, a larger diameter barrel, and a taller and narrower solids inlet. The improved design has a predicted pressure drop 11 times lower than the original design while reducing the mass loss by a factor of 2.3.

42 ENGINEERING↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Using Machine Learning Tools to Predict Compressor Stall

Clean energy has become an increasingly important consideration in today’s power systems. As the push for clean energy continues, many coal-fired power plants are being decommissioned in favor of renewable power sources such as wind and solar. However, the intermittent nature of renewables means that dynamic load following traditional power systems is crucial to grid stability. With high flexibility and fast response at a wide range of operating conditions, gas turbine systems are poised to become the main load following component in the power grid. Yet, rapid changes in load can lead to fluid flow instabilities in gas turbine power systems. These instabilities often lead to compressor surge and stall, which are some of the most critical problems facing the safe and efficient operation of compressors in turbomachinery today. Although the topic of compressor surge and stall has been extensively researched, no methods for early prediction have been proven effective. This study explores the utilization of machine learning tools to predict compressor stall. The long short-term memory (LSTM) model, a form of recurrent neural network (RNN), was trained using real compressor stall datasets from a 100 kW recuperated gas turbine power system designed for hybrid configuration. Two variations of the LSTM model, classification and regression, were tested to determine optimal performance. The regression scheme was determined to be the most accurate approach, and a tool for predicting compressor stall was developed using this configuration. Overall, results show that the tool is capable of predicting stalls 5–20 ms before they occur. With a high-speed controller capable of 5 ms time-steps, mitigating action could be taken to prevent compressor stall before it occurs.

42 ENGINEERING↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Performance of Hybrid Renewable Energy Power System for a Residential Building

Using fossil fuels as the primary way to generate electricity causes a significant effect on the environment. In 2019, more than 64% of the electricity in the United States of America was generated using fossil-fuel resources, while renewable energy (RE) resources contributed to only 17% of the U.S. electricity generation for the same year. Additionally, due to the complex terrain distribution of many states in the U.S., a massive opportunity of utilizing RE resources in rural and remote areas can reduce the cost of electrical grid installation for such areas. In this study, a typical residential building with an average energy utilization of 30.25 kWh/day with a demand peak of 5.34 kW was considered a case study in each state to optimize a hybrid RE system and find the best alternative electrical grid system. This study presents the best configuration between solar and wind energy with different types of energy storage. It was discovered the photovoltaic (PV) solar panels—diesel generators with battery best services in all states. The daily radiation and diesel prices substantially affect the levelized cost of energy (COE) values in each state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

A Simplified Numerical Approach to Characterize the Thermal Response of a Moving Bed Solar Reactor

Abstract Concentrated solar thermochemical storage in the form of a zero-emission fuel is a promising option to produce long-duration energy storage. Solar fuel is produced using a cavity reactor that captures concentrated solar radiation from a solar field of heliostats. In this paper, heat transfer model of a tubular plug-flow reactor designed and manufactured for a solar fuel production is presented. Experimental data collected from a fixed bed tubular reactor testing are used for model comparison. The system consists of an externally heated tube with counter-current flowing gas and moving solid particles as the heated media. The proposed model simulates the dynamic behavior of temperature profiles of the tube wall, gas, and particles under various gas flowrates and residence times. The heat transfer between gas–wall, solid particle–wall, and gas–solid particle is numerically studied. The model results are compared with the results of experiments done using a 4 kW furnace with a 150 mm heating zone surrounding a horizontal alumina tube (reactor) with 50.8 mm outer diameter and thickness of 3.175 mm. Solid fixed particles of magnesium manganese oxide (MgMn2O4) with the size of 1 mm are packed within the length of 250 mm at the center of the tube length. Simulation results are assessed with respect to fixed bed experimental data for four different gas flowrates, namely, 5, 10, 15, and 20 standard liters per minute of air, and furnace temperatures in the range of 200–1200 °C. The simulation results showed good agreement with maximum steady state error that is less than 6% of those obtained from the experiments for all runs. The proposed model can be implemented as a low-order physical model for the control of temperature inside plug-flow reactors for thermochemical energy storage applications.

Engineering↗

FOULING MITIGATION FOR LASER IGNITERS IN NATURAL GAS ENGINES

Due to several recent developments in lasers and optics, laser igniters can now be designed to be (i) compact so as to have the same footprint as a standard spark plug, (ii) have low power draw, usually less than 50 Watts, and (iii) have vibration and temperature resistance at levels typical of reciprocating engines. Primary advantages of these laser igniters remain (i) extension of lean or dilution limits for ignition of combustible mixtures, and (ii) improved ignition at higher pressures. Recently, tests performed in a 350 kW six-cylinder stationary natural gas reciprocating engine retrofitted with these igniters showed an extension of the operational envelope to yield efficiency improvements of the order of 2.6% points while being compliant with the mandated emission regulations. Even though laser igniters offer promise, fouling of the final optical element that introduces the laser into the combustion chamber is of concern. After performing a thorough literature search, a test plan was devised to evaluate various fouling mitigation strategies. The final approach that was used is a combination of three strategies and helped sustain an optical transmissivity exceeding 98% even after 1500 h of continuous engine operation at 2400 rpm. Based on the observed trend in transmissivity, it now appears that laser igniters can last up to 6000 h of continuous engine operation in a stationary engine running at 1800 rpm.

spark ignited engines, laser ignition, natural gas↗