Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “infrastructure optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Combined Land Use of Solar Infrastructure and Agriculture for Socioeconomic and Environmental Co-Benefits in the Tropics

Solar photovoltaics (PV) are on the rise even in areas of low solar insolation. However, in developing countries with limited capital, land scarcity, or with geographically isolated agrarian communities, large solar infrastructures are often impractical. In these cases, implementation of low-density PV over existing crops may be required to integrate renewable energy services into rural communities. Here, using Indonesia as a model system, we investigated the land use, energy, greenhouse gas emissions, economic feasibility, and the environmental co-benefits associated with off-grid solar PV when combined with high value crop cultivation. The life cycle analyses indicate that small-scale dual land-use systems are economically viable in certain configurations and have the potential to provide several co-benefits including rural electrification, retrofitting diesel electricity generation, and electricity for processing agricultural products locally. A hypothetical full-density off-grid solar PV for a model village in Indonesia shows that electricity output (1907.5 GJ yr-1) is much higher than the total residential consumption (678 GJ yr-1), highlighting the opportunity to downscale the PV infrastructure by half to lower capital cost, to co-locate crops, and to support secondary income generating activities. Economic analysis shows that the 30-year net present cost of electricity from the half-density co-located PV system (12,257 million IDR) is significantly lower than that of the flat cost of diesel required to generate equivalent electricity (14,702 million IDR). Our analysis provides insights for smarter energy planning by optimizing the efficiency of land use and limiting conversion of agricultural and forested areas for energy production.

agrivoltaics↗

DISTRI: Distributed Multi-Facility HPC Simulator (DISTRI) v2.1

DISTRI is an advanced network simulator designed for multi-facility computational infrastructures with agentic behavior. It simulates HPC facilities where computational resources act as autonomous agents, making intelligent decisions about job scheduling, load balancing, and resource allocation. The simulator focuses on developing and testing decentralized algorithms that promote resilience and efficiency in multi-facility environments. Key Features: - Agentic Resource Behavior: Processors and DTNs act as autonomous agents with decision-making capabilities - Pheromone-Based Load Balancing: Decentralized load balancing inspired by ant colony optimization - Dual Topology Support: Mesh (normal operations) and Dumbell (network testing) topologies - Comprehensive TCP Simulation: Realistic TCP implementations with multiple congestion control algorithms - Failure Resilience Testing: Processor failure simulation with automatic job reassignment - Extensive Visualization: Detailed performance analysis and metrics collection - Research-Ready: Designed for algorithm development and benchmarking

Bez, Jean Luca [Lawrence Berkeley National Laborat↗

Quantum teleportation coexisting with classical communications in optical fiber

The ability for quantum and conventional networks to operate in the same optical fibers would aid the deployment of quantum network technology on a large scale. Quantum teleportation is a fundamental operation in quantum networking, but has yet to be demonstrated in fibers populated with high-power conventional optical signals. Here we report, to the best of our knowledge, the first demonstration of quantum teleportation over fibers carrying conventional telecommunications traffic. Quantum state transfer is achieved over a 30.2-km fiber carrying 400-Gbps C-band classical traffic with a Bell state measurement performed at the fiber’s midpoint. To protect quantum fidelity from spontaneous Raman scattering noise, we use optimal O-band quantum channels, narrow spectro-temporal filtering, and multi-photon coincidence detection. Fidelity is shown to be well maintained with an elevated C-band launch power of 18.7 dBm for the single-channel 400-Gbps signal, which we project could support multiple classical channels totaling many terabits/s aggregate data rates. These results show the feasibility of advanced quantum and classical network applications operating within a unified fiber infrastructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the Expansion of Ground-Motion Sensing Capability in Smart Cities via Internet Fiber-Optic Infrastructure

Monitoring ground motion in smart cities can improve the public safety by providing critical insights on natural and anthropogenic hazards, for example, earthquakes, landslides, explosions, infrastructure failures, and so forth. Although seismic activity is typically measured using dedicated point sensors (e.g., geophones and accelerometers), techniques such as distributed acoustic sensing have demonstrated the utility of using fiber-optic cable to detect seismic activity over comparable distances. In this article, we present the results of a study that quantifies the expansion in an area monitored for low-amplitude ground-motion events by augmenting existing point sensors with the internet fiber-optic cable infrastructure. Here we begin by describing our methodology, which utilizes geospatial data on point sensors and internet optical fiber deployed in metropolitan statistical areas (MSAs) in the United States. We extend these data to identify the area that can be monitored by (1) considering the observed seismic noise data in target locations, (2) applying the model from Wilson et al. (2021) to understand the potential coverage area gains using optical fiber sensing, and (3) optimizing the selection of fiber segments to maximize coverage and minimize deployment costs. We implement our methodology in ArcGIS to assess the additional area that can be monitored for low-amplitude ground-motion events (i.e., magnitude >0.5) by utilizing internet fiber-optic cables in the 100 most populous MSAs in the United States. We find that the addition of internet fiber-based sensors in MSAs would increase the area monitored on average by over an order of magnitude from 1% to 12%, if the subset of fiber cable segments that maximize coverage and minimize deployment costs is chosen even if only 20% of all fibers are used.

58 GEOSCIENCES↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy‐aware relay positioning in flying networks

Summary The ability to move and hover has made rotary‐wing unmanned aerial vehicles (UAVs) suitable platforms to act as flying communications relays (FCRs), aiming at providing on‐demand, temporary wireless connectivity when there is no network infrastructure available or a need to reinforce the capacity of existing networks. However, since UAVs rely on their on‐board batteries, which can be drained quickly, they typically need to land frequently for recharging or replacing them, limiting their endurance and the flying network availability. The problem is exacerbated when a single FCR UAV is used. The FCR UAV energy is used for two main tasks: Communications and propulsion. The literature has been focused on optimizing both the flying network performance and energy efficiency from the communications point of view, overlooking the energy spent for the UAV propulsion. Yet, the energy spent for communications is typically negligible when compared with the energy spent for the UAV propulsion. In this article, we propose energy‐aware relay positioning (EREP), an algorithm for positioning the FCR taking into account the energy spent for the UAV propulsion. Building upon the conclusion that hovering is not the most energy‐efficient state, EREP defines the trajectory and speed that minimize the energy spent by the FCR UAV on propulsion, without compromising in practice the quality of service offered by the flying network. The EREP algorithm is evaluated using simulations. The obtained results show gains up to 26% in the FCR UAV endurance for negligible throughput and delay degradation.

Rodrigues, Hugo↗

Optimal Portfolio Design of Distributed Energy Resources on Puerto Rico Distribution Feeders with Long Outages after Hurricane Maria

This work details a project to design reliable, resilient, and cost-effective networked microgrids considering grid constraints and resilience metrics focused on Puerto Rico distribution feeder locations with long outages after Hurricane Maria. The project consisted primarily of modeling and simulation tasks that accomplished the following objectives: 1. Selected 10 distribution feeder models in vulnerable areas. The sample feeders are geographically distributed across Puerto Rico and vary in length to capture the wide variety of feeders on the island. 2. Determined the optimal location and sizing of distributed energy resources (DERs) on the identified distribution feeders. The systems considered as part of the microgrid solutions were solar photovoltaic (PV), battery energy storage systems (BESS) and distributed fossil fuel generation (DFFG). 3. Estimated the cost-benefit of the proposed DER portfolios. 4. Provided a set of final recommendations that inform decision making on how to do targeted planning analysis for microgrids that can supply energy to critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-dimensional fracture continuum characterization aided by surface time-domain electromagnetics and hydrogeophysical joint inversion—proof-of-concept

Efficient and safe production of hydraulically fractured reservoirs benefits from the prediction of their geometrical attributes. Geophysical methods have the potential to provide data that are sensitive to fracture geometries, alleviating the typically sparse nature of in situ reservoir observations. Moreover, surface-based methods can be logistically and economically attractive since they avoid operational interference with the injection well infrastructure. Here, we investigate the potential of the surface-based time-domain electromagnetic (EM) method. EM methods can play an important role owing to their sensitivity to injection-induced fluid property changes. Two other advantageous factors are the EM signal-enhancing effect of vertical steel-cased wells and the fact that injected proppants can be enhanced to produce a stronger electrical conductivity contrast with the reservoir’s connate fluid. Nevertheless, an optimal fracture characterization will no doubt require the integration of EM and reservoir injection and production data. We hence carry out our investigations within a hydrogeophysical parameter estimation framework where EM data and injection flow rates are combined in a fully coupled way. Given the interdisciplinary nature of coupled hydrogeophysical inverse modeling, we dedicate one section to laying out key aspects in a didactic manner.

58 GEOSCIENCES↗

A Vehicle-to-Grid planning framework incorporating electric vehicle user equilibrium and distribution network flexibility enhancement

The rapid surge in electric vehicle (EV) adoption, coupled with advancements in charging technologies, emphasizes the critical necessity for expanding EV recharging infrastructure. Simultaneously, the Distribution Network (DN) encounters escalating challenges in meeting charging demand during peak traffic periods. Consequently, there is a mounting demand for the deployment of innovative Vehicle-to-Grid (V2G) technologies to augment the DN’s flexibility in power dispatch and alleviate travel costs for EV users. Hence, this paper proposes an EV-user-equilibrium-(UE)-constrained V2G planning framework that enhances flexibility in the DN. The framework aims to ascertain the optimal placement and capacity of EV charging stations (EVCSs) and V2G charging piles within the Transportation Network (TN). It takes into account the equilibrium condition stemming from competitive EV charging and routing behaviors alongside the optimal expansion of DN energy resources to accommodate the electricity supplied by the V2G piles. This study commences by analyzing EV drivers’ travel decisions, considering the influence of charging and V2G pile locations and sizes. Subsequently, we tackle the Traffic Assignment Problem with User Equilibrium (TAP-UE) model to characterize the steady-state traffic flow distribution of EVs. Following this, we formulate the optimization model for the Coordinated Power and Transportation Network (CPTN), which encompasses the optimal expansion of DN facilities and traffic flow regulation under UE conditions. To mitigate the computational complexity associated with the V2G planning model, we introduce a series of linearization methods to obtain a manageable Mixed-Integer Linear Programming (MILP) solution. Finally, to validate the efficacy of our proposed planning framework, we apply it to two test systems, including a real-world case study. Through these case studies, we explore the necessity and potential benefits of V2G technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic land use implications of rapidly expanding and evolving wind power deployment

Abstract The expansion of wind power poses distinct and varied geographic challenges to a sustainable energy transition. However, current knowledge of its land use impacts and synergies is limited by reliance on static characterizations that overlook the role of turbine technology and plant design in mediating interactions with the environment. Here, we investigate how wind technology development and innovation have shaped landscape interactions with social and ecological systems within the United States and contribute to evolving land area requirements. This work assesses trends in key land use facets of wind power using a holistic set of metrics to establish an evidence base that researchers, technology designers, land use managers, and policymakers can use in envisioning how future wind-intensive energy systems may be jointly optimized for clean energy, social, and environmental objectives. Since 2000, we find dynamic land occupancy patterns and regional trends that are driven by advancing technology and geographic factors. Though most historical U.S. wind deployment has been confined to the temperate grassland biome in the nation’s interior, regional expansion has implicated diverse land use and cover types. A large percentage of the typical wind plant footprint (∼96% to > 99%) is not directly impacted by permanent physical infrastructure, allowing for multiple uses in the spaces between turbines. Surprisingly, turbines are commonly close to built structures. Moreover, rangeland and cropland have supported 93.4% of deployment, highlighting potential synergies with agricultural lands. Despite broadly decreasing capacity densities, offsetting technology improvements have stabilized power densities. Land use intensity, defined as the ratio of direct land usage to lifetime power generation of wind facilities, has also trended downwards. Although continued deployment on disturbed lands, and in close proximity to existing wind facilities and other infrastructure, could minimize the extent of impacts, ambitious decarbonization trajectories may predispose particular biomes to cumulative effects and risks from regional wind power saturation. Increased land-use and sustainability feedback in technology and plant design will be critical to sustainable management of wind power.

17 WIND ENERGY↗

Port Technical Assistance Program: A Proposed Initiative to Support U.S. Ports Through Energy Innovation

This document highlights the crucial importance of the maritime sector within the United States (U.S.) economy, serving as a key node for trade and global goods transportation. U.S. ports are currently grappling with challenges posed by rising shipping demands, the health impacts of diesel fuel reliance, and the technology adoptions of global trade partners due to increasing environmental regulations. This document proposes forming a technical assistance program, led by Pacific Northwest National Laboratory (PNNL), to help U.S. ports transition to sustainable energy solutions that not only improve environmental and community outcomes, but also enhance resilience to unexpected weather events and reduce pressure on local utilities. Coordinated by PNNL, this initiative would offer a web-based platform of consolidated resources and tools for comprehensive strategic planning and cost-benefit analysis. It also seeks to establish a collaborative network between ports and national laboratories to facilitate the sharing of best practices. The document suggests that optimizing resource allocation and providing tailored support could be achieved through strategic categorization of ports within this network, with relevant attributes and examples detailed in the report. The anticipated benefits of such a program could include increased efficiency and cost savings in port operations and the advancement of scientific innovation via alternative energy research. Also, it could enhance economic growth and competitiveness in international trade by enabling ports to meet shipping demands and develop resilient critical infrastructure through informed, long-term strategies.

33 ADVANCED PROPULSION SYSTEMS↗

EVALUATING FACILITY ENERGY EFFICIENCY AND RESILIENCE OPPORTUNITIES WITH FEDS AND MCOR

Energy resilience has become increasingly important for critical building infrastructure, in response to concerns over potential disruptions to the electrical grid from threats both natural and man-made. Energy efficiency can provide a valuable resource for reducing critical loads and therefore lowering the cost of supplying alternative power. This paper highlights two tools that are well-suited for analyzing building energy efficiency and resilience opportunities and presents a case study for their combined application. The Facility Energy Decision System (FEDS) and Microgrid Component Optimization for Resilience (MCOR) tools can be used together to simulate building systems, identify energy efficiency measures, and evaluate resilience options for powering a site during an outage.

FEDS, MCOR, Energy Efficiency, Resilience, Simulat↗

Optimize the Autonomous Sensor Fish Device for Understanding Interactions of Aquatic Animals with Marine and Hydrokinetic and Hydro Systems (CRADA 476) Final Report

This project at the Pacific Northwest National Laboratory (PNNL) enhances our understanding of how aquatic life interacts with marine renewable energy (MRE) and hydropower systems through the development and testing of advanced sensor technology. The Marine Sensor Fish (MSF) and its smaller variants, the Sensor Fish Mini (SF Mini) and Flexible Sensor Fish (FSF), measure critical environmental stressors, such as shear forces, pressure changes, and strike impacts, that are essential for assessing the risks posed by energy devices, including tidal turbines, hydropower installations, and other MRE infrastructure. Rigorous field testing has shown that these tools are effective in capturing detailed data on turbulence, pressure variations, strike impacts, and other stressors near these devices, providing valuable insights into the conditions faced by aquatic species. Economically, these tools offer renewable energy developers a practical solution for streamlining environmental assessments and ensuring regulatory compliance, ultimately reducing costs associated with evaluating and mitigating ecological impacts. This research also benefits the public by promoting the growth of renewable energy sources that protect aquatic ecosystems, advancing both sustainable energy production and environmental stewardship.

13 HYDRO ENERGY↗

DC Fast Charging Infrastructure for Electrified Road Trips

To assess DC fast charging station network required for electrified road trips by 2030 in California, a new charging infrastructure simulation tool/model, EVI-Pro (Electric Vehicle Infrastructure Projection) RoadTrip, has been developed. In contrast to the existing EVI-Pro model that is primarily for short-distance travels, EVI-Pro RoadTrip is exclusively focused on road trips (long-distance travels, 100 or miles per day per vehicle). Also, the charging paradigm or strategy is different. EVI-Pro RoadTrip is built upon waypoint charging, in which vehicles are forced to stop to charge or replenish the on-board batteries, along the routes between origins and destinations. On the other hand, EVI-Pro is based on destination charging, in which charging is conducted when vehicles are parked in destinations (e.g., work, home). EVI-Pro RoadTrip takes coordinate-level origin and destination data for road trips (intra-state as well as domestic or international out-of-state) and estimates energy consumption and charging needs along the routes between origins and destinations on a minute-by-minute resolution. Based on charging demands for electrified road trips across the state, the optimal locations of charging stations are determined accounting for preferred land use types (e.g., commercial areas) and station service area (e.g., 5 or less miles). Based on station-by-station charging load profiles, the required number of plugs/connectors is estimated for each station and entire state. By comparing hosting capacity of the electric grid (circuit-level) and the charging load output from EVI-Pro RoadTrip, capacity deficit is also evaluated.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Learning model combining convolutional deep neural network with a self-attention mechanism for AC optimal power flow

Alternating current optimal power flow (OPF) analysis is critical for efficient and reliable operation of power systems. For large systems or repetitive computations, the traditional methods such as the direct and gradient methods, or non-traditional methods, such as the genetic algorithm and simulating annealing, are time-consuming and unsuitable for real-time computing. The work in this paper proposes a novel framework to obtain the optimal solution of power flow in real-time using a combination of convolutional neural networks and a self-attention mechanism. All parameters of the power networks are rearranged in an image-like shape of a multi-channel image where each channel is a two-dimensional matrix. The proposed approach is adaptive with every input size of power systems as well as frequent variations of network topologies without intervention to the framework core. The encompassment of all power system contexts in which all parameters of internal elements, generation costs, and topology information are included, contributes to the higher accuracy of inference compared to other current machine-learning-based OPF-solving methods. Besides, the proposed framework established on ubiquitous platforms is effortlessly integrated into current infrastructures of power systems, and the great efficiency along with the computation speed may serve as a critical point for practical implications, such as enabling faster decision-making during real-time operations, predicting system contingencies, and remedial actions based on an offline pre-trained model. Furthermore, this supervised learning process is applied to the dataset of four case studies of meshed power systems: the IEEE 5-bus system (IEEE-5), the IEEE 30-bus system (IEEE-30), the IEEE 39-bus system (IEEE-39), and the IEEE 57-bus system (IEEE-57) to prove the efficacy of the proposed method.

42 ENGINEERING↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗