Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Cleaning Images with Gaussian Process Regression

Many approaches to astronomical data reduction and analysis cannot tolerate missing data: corrupted pixels must first have their values imputed. This paper presents astrofix, a robust and flexible image imputation algorithm based on Gaussian process regression. Through an optimization process, astrofix chooses and applies a different interpolation kernel to each image, using a training set extracted automatically from that image. It naturally handles clusters of bad pixels and image edges and adapts to various instruments and image types. For bright pixels, the mean absolute error of astrofix is several times smaller than that of median replacement and interpolation by a Gaussian kernel. We demonstrate good performance on both imaging and spectroscopic data, including the SBIG 6303 0.4 m telescope and the FLOYDS spectrograph of Las Cumbres Observatory and the CHARIS integral-field spectrograph on the Subaru Telescope.

42 ENGINEERING↗

Discriminating Accretion States via Rotational Symmetry in Simulated Polarimetric Images of M87

In 2017 April, the Event Horizon Telescope observed the shadow of the supermassive black hole at the core of the elliptical galaxy Messier 87. While the original image was constructed from measurements of the total intensity, full polarimetric data were also collected, and linear polarimetric images are expected in the near future. We propose a modal image decomposition of the linear polarization field into basis functions with varying azimuthal dependence of the electric vector position angle. We apply this decomposition to images of ray traced general relativistic magnetohydrodynamics simulations of the Messier 87 accretion disk. Furthermore, for simulated images that are physically consistent with previous observations, the magnitude of the coefficient associated with rotational symmetry, β2, is a useful discriminator between accretion states. We find that at 20 μas resolution, $| {\beta }_{2}| $ is greater than 0.2 only for models of disks with horizon-scale magnetic pressures large enough to disrupt steady accretion. We also find that images with a more radially directed electric vector position angle correspond to models with higher black hole spin. Our analysis demonstrates the utility of the proposed decomposition as a diagnostic framework to improve constraints on theoretical models.

79 ASTRONOMY AND ASTROPHYSICS↗

The Polarized Image of a Synchrotron-emitting Ring of Gas Orbiting a Black Hole

Synchrotron radiation from hot gas near a black hole results in a polarized image. The image polarization is determined by effects including the orientation of the magnetic field in the emitting region, relativistic motion of the gas, strong gravitational lensing by the black hole, and parallel transport in the curved spacetime. We explore these effects using a simple model of an axisymmetric, equatorial accretion disk around a Schwarzschild black hole. By using an approximate expression for the null geodesics derived by Beloborodov and conservation of the Walker–Penrose constant, we provide analytic estimates for the image polarization. We test this model using currently favored general relativistic magnetohydrodynamic simulations of M87*, using ring parameters given by the simulations. For a subset of these with modest Faraday effects, we show that the ring model broadly reproduces the polarimetric image morphology. Our model also predicts the polarization evolution for compact flaring regions, such as those observed from Sgr A* with GRAVITY. With suitably chosen parameters, our simple model can reproduce the EVPA pattern and relative polarized intensity in Event Horizon Telescope images of M87*. Under the physically motivated assumption that the magnetic field trails the fluid velocity, this comparison is consistent with the clockwise rotation inferred from total intensity images.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the LSST Difference Image Analysis Pipeline Using Synthetic Source Injection Analysis

Abstract We evaluate the performance of the Legacy Survey of Space and Time Science Pipelines Difference Image Analysis (DIA) on simulated images. By adding synthetic sources to galaxies on images, we trace the recovery of injected synthetic sources to evaluate the pipeline on images from the Dark Energy Science Collaboration Data Challenge 2. The pipeline performs well, with efficiency and flux accuracy consistent with the signal-to-noise ratio of the input images. We explore different spatial degrees of freedom for the Alard–Lupton polynomial-Gaussian image subtraction kernel and analyze for trade-offs in efficiency versus artifact rate. Increasing the kernel spatial degrees of freedom reduces the artifact rate without loss of efficiency. The flux measurements with different kernel spatial degrees of freedom are consistent. We also here provide a set of DIA flags that substantially filter out artifacts from the DIA source table. We explore the morphology and possible origins of the observed remaining subtraction artifacts and suggest that given the complexity of these artifact origins, a convolution kernel with a set of flexible bases with spatial variation may be needed to yield further improvements.

Liu, S. (ORCID:0000000244612143)↗

First Sagittarius A* Event Horizon Telescope Results. III. Imaging of the Galactic Center Supermassive Black Hole

We present the first event-horizon-scale images and spatiotemporal analysis of Sgr A* taken with the Event Horizon Telescope in 2017 April at a wavelength of 1.3 mm. Imaging of Sgr A* has been conducted through surveys over a wide range of imaging assumptions using the classical CLEAN algorithm, regularized maximum likelihood methods, and a Bayesian posterior sampling method. Different prescriptions have been used to account for scattering effects by the interstellar medium toward the Galactic center. Mitigation of the rapid intraday variability that characterizes Sgr A* has been carried out through the addition of a “variability noise budget” in the observed visibilities, facilitating the reconstruction of static full-track images. Our static reconstructions of Sgr A* can be clustered into four representative morphologies that correspond to ring images with three different azimuthal brightness distributions and a small cluster that contains diverse nonring morphologies. Based on our extensive analysis of the effects of sparse (u,v)-coverage, source variability, and interstellar scattering, as well as studies of simulated visibility data, we conclude that the Event Horizon Telescope Sgr A* data show compelling evidence for an image that is dominated by a bright ring of emission with a ring diameter of ∼50 μas, consistent with the expected “shadow” of a 4 × 10$^{6}$ M $_{⊙}$ black hole in the Galactic center located at a distance of 8 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Shallow cumuli cover and its uncertainties from ground-based lidar–radar data and sky images

Cloud cover estimates of single-layer shallow cumuli obtained from narrow field-of-view (FOV) lidar–radar and wide-FOV total sky imager (TSI) data are compared over an extended period (2000–2017 summers) at the established United States Atmospheric Radiation Measurement mid-continental Southern Great Plains site. We quantify the impacts of two factors on hourly and sub-hourly cloud cover estimates: (1) instrument-dependent cloud detection and data merging criteria and (2) FOV configuration. Enhanced observations at this site combine the advantages of the ceilometer, micropulse lidar (MPL) and cloud radar in merged data products. Data collected by these three instruments are used to calculate narrow-FOV cloud fraction (CF) as a temporal fraction of cloudy returns within a given period. Sky images provided by TSI are used to calculate the wide-FOV fractional sky cover (FSC) as a fraction of cloudy pixels within a given image. To assess the impact of the first factor on CF obtained from the merged data products, we consider two additional subperiods (2000–2010 and 2011–2017 summers) that mark significant instrumentation and algorithmic advances in the cloud detection and data merging. We demonstrate that CF obtained from ceilometer data alone and FSC obtained from sky images provide the most similar and consistent cloud cover estimates; hourly bias and root-mean-square difference (RMSD) are within 0.04 and 0.12, respectively. However, CF from merged MPL–ceilometer data provides the largest estimates of the multiyear mean cloud cover, about 0.12 (35 %) and 0.08 (24 %) greater than FSC for the first and second subperiods, respectively. CF from merged ceilometer–MPL–radar data has the strongest subperiod dependence with a bias of 0.08 (24 %) compared to FSC for the first subperiod and shows no bias for the second subperiod. The strong period dependence of CF obtained from the combined ceilometer–MPL–radar data is likely results from a change in what sensors are relied on to detect clouds below 3 km. After 2011, the MPL stopped being used for cloud top height detection below 3 km, leaving the radar as the only sensor used in cloud top height retrievals. To quantify the FOV impact, a narrow-FOV FSC is derived from the TSI images. We demonstrate that FOV configuration does not modify the bias but impacts the RMSD (0.1 hourly, 0.15 sub-hourly). In particular, the FOV impact is significant for sub-hourly observations, where 41 % of narrow- and wide-FOV FSC differ by more than 0.1. A new “quick-look” tool is introduced to visualize impacts of these two factors through integration of CF and FSC data with novel TSI-based images of the spatial variability in cloud cover. The influence of cloud field organization, such cloud streets parallel to the wind direction, on narrow- and wide-FOV cloud cover estimates can be visually assessed.

54 ENVIRONMENTAL SCIENCES↗

Legacy Survey of Space and Time Data Preview 1: difference_image dataset type

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of the difference_image dataset type. These are images created by subtracting a template image from a visit image. This release contains 15,972 datasets of this type.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical array for high-quality imaging in harsh environments

Methods and apparatus are disclosed for producing high quality images in uncontrolled or impaired environments. In some examples of the disclosed technology, groups of cameras for high dynamic range (HDR), polarization diversity, and optional other diversity modes are arranged to concurrently image a common scene. For example, in a vehicle checkpoint application, HDR provides discernment of dark objects inside a vehicle, while polarization diversity aids in rejecting glare. Spectral diversity, infrared imaging, and active illumination can be applied for better imaging through a windshield. Preprocessed single-camera images are registered and fused. Faces or other features of interest can be detected in the fused image and identified in a library. Impairments can include weather, insufficient or interfering lighting, shadows, reflections, window glass, occlusions, or moving objects.

42 ENGINEERING↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Two and three-dimensional near infrared subcutaneous structure imager using realtime nonlinear video processing

A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.

Krasowski, Michael J.↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical array for high-quality imaging in harsh environments

Methods and apparatus are disclosed for producing high quality images in uncontrolled or impaired environments. In some examples of the disclosed technology, groups of cameras for high dynamic range (HDR), polarization diversity, and optional other diversity modes are arranged to concurrently image a common scene. For example, in a vehicle checkpoint application, HDR provides discernment of dark objects inside a vehicle, while polarization diversity aids in rejecting glare. Spectral diversity, infrared imaging, and active illumination can be applied for better imaging through a windshield. Preprocessed single-camera images are registered and fused. Faces or other features of interest can be detected in the fused image and identified in a library. Impairments can include weather, insufficient or interfering lighting, shadows, reflections, window glass, occlusions, or moving objects.

Baba, Justin S.↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Cancer cell membrane-coated rare earth doped nanoparticles for tumor surgery navigation in NIR-II imaging window

With the attractive characteristics of low toxicity, narrow emission spectra, long fluorescence lifetime, and no photobleaching, rare-earth doped nanoparticles (RENPs) have become promising imaging nanoplatforms in the second near-infrared window (NIR-II, 1000–1700 nm). Many studies have been devoted to different surface modification strategies of RENPs to achieve good NIR-II tumor imaging property. However, the tumor imaging efficiency of these approaches remains disappointing. Herein, two methods were pursued to modify RENPs with either polyethylene glycol (PEG) or cancer-cell-membrane to generate PEGylated-RENPs and cancer-cell-membrane camouflaged RENPs (CC-RENPs), respectively. Furthermore, this study demonstrated that cancer-cell-membrane coating of RENPs greatly improved tumor imaging performance in NIR-II window than PEG coating. Besides, CC-RENPs uptakes in liver and spleen significantly decreased. Importantly, CC-RENPs was found to be capable to aid us to pursue precise resection of the tumor. In conclusion, CC-RENPs are capable of targeting tumors and show high tumor NIR-II imaging quality. They are highly promising nanomaterials for future medical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗