Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imager”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

3D Characterization and Time-Lapse Imaging of the Desiccation Treatability Test at the Hanford BC-Cribs and Trenches Site using High Performance Computing applied to Electrical Resistivity Imaging - 12271

Contaminated vadose zone materials are a potential source of long-term groundwater contamination at many sites across the Department of Energy (DOE) complex. Deep vadose zone contamination presents a particularly challenging remedial problem due to the difficultly of locating contaminants and the expense of access and ex situ treatment. In situ remediation techniques, whereby remedial amendments must be delivered to contaminated soils, have been identified as a potential alternative. However, amendment delivery is typically uncertain and post delivery remedial performance is often not well understood due to limited information available from sparsely spaced boreholes. Recent advancements in electrical resistivity tomography (ERT) are being used to address these challenges at the Hanford site by providing remote, three-dimensional images of contaminant distribution and four-dimensional (three spatial dimensions plus the time dimension) images of in-situ vadose zone remediation processes. These capabilities were recently demonstrated with a large scale surface characterization effort and during a smaller scale desiccation treatability test at the Hanford BC-Cribs area. The results of these efforts demonstrate the utility of leveraging high-performance computing resources to process ERT data for 3D reconnaissance mapping of subsurface contaminants and for detailed 3D monitoring of vadose zone remediation efforts. Two examples of ERT imaging at a former waste disposal facility have been demonstrated at different scales; a large scale reconnaissance survey spanning many hundreds of meters and a detailed monitoring application spanning a few tens of meters. Although ERT is applicable at many scales, resolution is generally governed by proximity to electrodes. For instance, the BCCT reconnaissance survey demonstrated herein lost resolution with depth (i.e. away from surface electrodes), and was unable to detect a high conductivity anomaly at approximately 75 m below ground surface in the cribs area; the deep anomalies were detected during highly focused borehole sampling. Conversely, the desiccation site characterization and monitoring demonstrated high resolution at a small scale, but only because of close proximity to survey electrodes. Although proximity to electrodes is not the only factor governing ERT resolution, it is often the primary factor for determining how an ERT system should be effectively deployed for a given application. Regardless of resolution limitations, the utility of ERT for remotely detecting wastes and monitoring subsurface processes is evident. ERT imaging is not a final detection or monitoring solution alone, but provides a necessary capability to remotely detect subsurface conditions and understand subsurface processes. Such a capability can significantly increase the efficacy and reduce the cost of remediation by guiding sampling efforts and informing remedial system design and operation. However, given the computational demands of 3D ERT characterization and monitoring inversions, the full imaging capability enabled by contemporary ERT survey systems can generally only be realized with high performance computing resources, both hardware and software. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Imaging systems and related methods including radar imaging with moving arrays or moving targets

Imaging systems, including radio frequency, microwave and millimeter-wave arrangements, and related methods are described. According to one aspect, an imaging system includes an antenna array, a position capture system configured to generate position information indicative of locations of one of the antenna array and the target at the first and second moments in time, and wherein the one of the antenna array and the target move between the first and second moments in time, a transceiver configured to control the antenna array to emit electromagnetic energy towards the target and to generate an output that is indicative of the received electromagnetic energy, a data acquisition system configured to generate radar data, processing circuitry configured to process the position information and the radar data to generate image data regarding the target, and an interface configured to use the image data to generate visual images regarding the target.

Sheen, David M.↗

SimLBR: Learning to Detect Fake Images by Learning to Detect Real Images

The rapid advancement of generative models has made the detection of AI-generated images a critical challenge for both research and society. Recent works have shown that most state-of-the-art fake image detection methods overfit to their training data and catastrophically fail when evaluated on curated hard test sets with strong distribution shifts. In this work, we argue that it is more principled to learn a tight decision boundary around the real image distribution and treat the fake category as a sink class. To this end, we propose SimLBR, a simple and efficient framework for fake image detection with Latent Blending Regularization (LBR). Our method significantly improves cross-generator generalization, achieving up to +24.85% accuracy and +69.62% recall on the challenging Chameleon benchmark. SimLBR is also highly efficient, training orders of magnitude faster than existing approaches. Furthermore, we emphasize the need for reliability-oriented evaluation in fake image detection, introducing risk-adjusted metrics and worst-case estimates to better assess model robustness. All the code and models are availabe at: https://github.com/mvrl/SimLBR

Dhakal, Aayush [Washington University, St. Louis]↗

Edge-based correlation image registration for multispectral imaging

Registration information for images of a common target obtained from a plurality of different spectral bands can be obtained by combining edge detection and phase correlation. The images are edge-filtered, and pairs of the edge-filtered images are then phase correlated to produce phase correlation images. The registration information can be determined based on these phase correlation images.

97 MATHEMATICS AND COMPUTING↗

Dynamic shear localization of a titanium alloy under high-rate tension characterized by x-ray digital image correlation

Highlights: • First systematic error analyses for XDIC • First XDIC study of Ti-6Al-4V under dynamic tension • Deformation mode transition induces dynamic ductility decrease. • Dynamic shear localization due to rate-dependent microvoid coalescence process. - Abstract: Dynamic and quasi-static tension experiments are conducted on Ti-6Al-4V alloys, with in situ, synchrotron-based, high-speed, x-ray phase contrast imaging implemented to characterize the dynamic deformation and fracture process of Ti alloys at the Advanced Photon Source. X-ray digital imaging correlation (XDIC) is applied for strain field mapping. The size distribution of x-ray speckles are quantified via a morphological analysis, with a mean of ∼20 μm. Systematic error analyses of displacement and strain field measurements are firstly conducted for XDIC, and demonstrate that the displacement and strain errors can be controlled below 0.01 pixel and 0.1%, respectively. Mesoscale strain characteristics measured via XDIC are consistent with and reveal mechanisms for the bulk-scale stress–strain responses. Under dynamic tension, a sharp transition to strain softening occurs when the bulk strain exceeds about 0.04, which leads to a lower dynamic fracture strain (0.08) than the quasi-static one (0.1). The corresponding strain filed mapping demonstrates that shear deformation localizations grow and coalesce rapidly into a narrow shear deformation band under dynamic loading, while tensile deformation and necking progresses gradually under quasi-static loading. Scanning electron microscopy shows that void nucleation occurs mainly at the interface of α and β phases for both quasi-static and dynamic tension. However, microvoids coalesce preferentially along colony boundaries or the boundary α phase under quasi-static tension, but along the maximum shear stress direction (across colonies) under dynamic tension. Fractography of recovered samples also shows consistent features.

36 MATERIALS SCIENCE↗

Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis

Electrocatalysis is at the heart of a broad range of physicochemical applications that play an important role in the present and future of a sustainable economy. Among the myriad of different electrocatalysts used in this field, nanomaterials are of ubiquitous importance. An increased surface area/volume ratio compared to bulk makes nanoscale catalysts the preferred choice to perform electrocatalytic reactions. Bragg coherent diffraction imaging (BCDI) was introduced in 2006 and since has been applied to obtain 3D images of crystalline nanomaterials. BCDI provides information about the displacement field, which is directly related to strain. Lattice strain in the catalysts impacts their electronic configuration and, consequently, their binding energy with reaction intermediates. Even though there have been significant improvements since its birth, the fact that the experiments can only be performed at synchrotron facilities and its relatively low resolution to date (~10 nm spatial resolution) have prevented the popularization of this technique. Herein, we will briefly describe the fundamentals of the technique, including the electrocatalysis relevant information that we can extract from it. Subsequently, we review some of the computational experiments that complement the BCDI data for enhanced information extraction and improved understanding of the underlying nanoscale electrocatalytic processes. We next highlight success stories of BCDI applied to different electrochemical systems and in heterogeneous catalysis to show how the technique can contribute to future studies in electrocatalysis. Finally, we outline current challenges in spatiotemporal resolution limits of BCDI and provide our perspectives on recent developments in synchrotron facilities as well as the role of machine learning and artificial intelligence in addressing them.

bragg coherent diffraction imaging↗

Heuristic optimization in penumbral image for high resolution reconstructed image

Penumbral imaging is a technique which uses the fact that spatial information can be recovered from the shadow or penumbra that an unknown source casts through a simple large circular aperture. The size of the penumbral image on the detector can be mathematically determined as its aperture size, object size, and magnification. Conventional reconstruction methods are very sensitive to noise. On the other hand, the heuristic reconstruction method is very tolerant of noise. However, the aperture size influences the accuracy and resolution of the reconstructed image. In this article, we propose the optimization of the aperture size for the neutron penumbral imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray refraction-contrast computed tomography images using dark-field imaging optics

If an x-ray beam containing internal information derived from sample soft tissue is incident upon a Laue-case analyzer, the beam will subsequently split into a forwardly diffracted beam and a separate diffracted beam. Using these beams acquired simultaneously, a refraction-contrast computed tomography (CT) imaging system for biomedical use with lower radiation dose can be easily realized, and has a high depicting capability on the soft tissues compared with conventional x-ray CT based on absorption contrast principles. In this paper, we propose an imaging system using dark-field imaging for CT measurement based on a tandem system of Bragg- and Laue-case crystals with two two-dimensional detectors, along with a data-processing method to extract information on refraction from the measured entangled intensities by use of rocking curve fitting with polynomial functions. Reconstructed images of soft tissues are presented and described.

07 ISOTOPE AND RADIATION SOURCES↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

Comparison of Photoluminescence Imaging on Starting Multi-Crystalline Silicon Wafers to Finished Cell Performance: Preprint

Photoluminescence (PL) imaging techniques can be applied to multicrystalline silicon wafers throughout the manufacturing process. Both band-to-band PL and defect-band emissions, which are longer-wavelength emissions from sub-bandgap transitions, are used to characterize wafer quality and defect content on starting multicrystalline silicon wafers and neighboring wafers processed at each stepthrough completion of finished cells. Both PL imaging techniques spatially highlight defect regions that represent dislocations and defect clusters. The relative intensities of these imaged defect regions change with processing. Band-to-band PL on wafers in the later steps of processing shows good correlation to cell quality and performance. The defect band images show regions that changerelative intensity through processing, and better correlation to cell efficiency and reverse-bias breakdown is more evident at the starting wafer stage as opposed to later process steps. We show that thermal processing in the 200 degrees - 400 degrees C range causes impurities to diffuse to different defect regions, changing their relative defect band emissions.

14 SOLAR ENERGY↗

Automated data processing architecture for the Gemini Planet Imager Exoplanet Survey

The Gemini Planet Imager Exoplanet Survey (GPIES) is a multiyear direct imaging survey of 600 stars to discover and characterize young Jovian exoplanets and their environments. We have developed an automated data architecture to process and index all data related to the survey uniformly. An automated and flexible data processing framework, which we term the Data Cruncher, combines multiple data reduction pipelines (DRPs) together to process all spectroscopic, polarimetric, and calibration data taken with GPIES. With no human intervention, fully reduced and calibrated data products are available less than an hour after the data are taken to expedite follow up on potential objects of interest. The Data Cruncher can run on a supercomputer to reprocess all GPIES data in a single day as improvements are made to our DRPs. A backend MySQL database indexes all files, which are synced to the cloud, and a front-end web server allows for easy browsing of all files associated with GPIES. To help observers, quicklook displays show reduced data as they are processed in real time, and chatbots on Slack post observing information as well as reduced data products. Together, the GPIES automated data processing architecture reduces our workload, provides real-time data reduction, optimizes our observing strategy, and maintains a homogeneously reduced dataset to study planet occurrence and instrument performance.

79 ASTRONOMY AND ASTROPHYSICS↗

Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy

Imaging plays a vital role in radiation therapy and with recent advances in technology considerable emphasis has been placed on cone-beam CT (CBCT). Attaching a kV x-ray source and a flat panel detector directly to the linear accelerator gantry has enabled progress in target localization techniques, which can include daily CBCT setup scans for some treatments. However, with an increasing number of CT scans there is also an increasing concern for patient exposure. An intensity-weighted region-of-interest (IWROI) technique, which has the potential to greatly reduce CBCT dose, in conjunction with the chord-based backprojection-filtration (BPF) reconstruction algorithm, has been developed and its feasibility in clinical use is demonstrated in this article. A nonuniform filter is placed in the x-ray beam to create regions of two different beam intensities. In this manner, regions outside the target area can be given a reduced dose but still visualized with a lower contrast to noise ratio. Image artifacts due to transverse data truncation, which would have occurred in conventional reconstruction algorithms, are avoided and image noise levels of the low- and high-intensity regions are well controlled by use of the chord-based BPF reconstruction algorithm. The proposed IWROI technique can play an important role in image-guided radiation therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Ultra Low Power Imaging Systems Using CMOS Image Sensor Technology

The need for miniaturization in advanced science sensor systems has led to the development of a new image sensor technology, the active pixel image sensor (APS). The development of CMOS APS technology allows the integration of timing and control electronics, imaging detector arrays, signal chains and analog-to-digital conversion on a single integrated circuit. The impact on the imaging system is to reduce power by approximately 1000x over existing systems - from tens of watts to tens of milliwatts.

imaging↗

Image-Guided Localization Accuracy of Stereoscopic Planar and Volumetric Imaging Methods for Stereotactic Radiation Surgery and Stereotactic Body Radiation Therapy: A Phantom Study

Purpose: To evaluate the positioning accuracies of two image-guided localization systems, ExacTrac and On-Board Imager (OBI), in a stereotactic treatment unit. Methods and Materials: An anthropomorphic pelvis phantom with eight internal metal markers (BBs) was used. The center of one BB was set as plan isocenter. The phantom was set up on a treatment table with various initial setup errors. Then, the errors were corrected using each of the investigated systems. The residual errors were measured with respect to the radiation isocenter using orthogonal portal images with field size 3 x 3 cm{sup 2}. The angular localization discrepancies of the two systems and the correction accuracy of the robotic couch were also studied. A pair of pre- and post-cone beam computed tomography (CBCT) images was acquired for each angular correction. Then, the correction errors were estimated by using the internal BBs through fiducial marker-based registrations. Results: The isocenter localization errors ({mu} {+-}{sigma}) in the left/right, posterior/anterior, and superior/inferior directions were, respectively, -0.2 {+-} 0.2 mm, -0.8 {+-} 0.2 mm, and -0.8 {+-} 0.4 mm for ExacTrac, and 0.5 {+-} 0.7 mm, 0.6 {+-} 0.5 mm, and 0.0 {+-} 0.5 mm for OBI CBCT. The registration angular discrepancy was 0.1 {+-} 0.2{sup o} between the two systems, and the maximum angle correction error of the robotic couch was 0.2{sup o} about all axes. Conclusion: Both the ExacTrac and the OBI CBCT systems showed approximately 1 mm isocenter localization accuracies. The angular discrepancy of two systems was minimal, and the robotic couch angle correction was accurate. These positioning uncertainties should be taken as a lower bound because the results were based on a rigid dosimetry phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Dual particle imaging: Applications in security and environmental imaging

Radiation imaging detectors have been applied in a variety of fields for detection, localization and characterization of radioactive sources. In this work, we describe a handheld detection system (H2DPI) that can simultaneously image neutrons and gamma rays, and reconstruct the energy spectra of the incident particles. This system was applied to the detection and characterization of a plutonium metal source in experiments performed at the National Criticality Experiments Research Center, where the 4.5 kg plutonium source was placed approximately 60 cm from the H2DPI. Neutron and gamma-ray images were measured that show good agreement with the known location of the source. Furthermore, the H2DPI was also used to measure the neutron spectrum, which shows the expected shape of a Watt fission spectrum, and the gamma-ray energy spectrum, which shows the energies common to plutonium metal. Finally, we describe the application of the H2DPI in augmented reality, whereby real-time neutron and gamma-ray imaging data can be streamed to the Microsoft HoloLens to allow the user to visualize the source locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗