Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Science and Technology Review January/February 2011

This month's issue has the following articles: (1) World's Most Intense X-Ray Laser Focuses on Livermore Science - Commentary by William H. Goldstein; (2) Groundbreaking Science with the World's Brightest X Rays - Experiments with x rays of unparalleled brightness and extremely short duration aim to reveal new information about atoms and molecules in motion; (3) From Data to Discovery - Ongoing control system enhancements at the National Ignition Facility bolster the understanding of experimental data and keep the system performing at its peak; (4) The Sun in All Its Splendor - Onboard the Solar Dynamics Observatory, Livermore-developed multilayer mirrors are enabling unprecedented full-disk, high-resolution images of the Sun; and (5) Drilling Deep into Plant Veins - A novel combination of imaging techniques is being used to understand the three-dimensional architecture of plant cell walls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray-diffraction and electrical-transport imaging of superconducting superhydride (La,Y)H 10

Understanding how microscopic structural domains govern macroscopic electronic properties is central to advancing hydride superconductors, yet such correlations remain poorly resolved under pressure. We report the synthesis and characterization of (La 0.9 Y 0.1 )H 10 superhydrides exhibiting coexisting cubic $Fm\bar{3}m$ and $P6_3/mmc$ hexagonal clathrate phases observed over the pressure range from 168 GPa down to 136 GPa. Using synchrotron-based X-ray diffraction imaging at the upgraded Advanced Photon Source, we spatially resolved μm-scale distributions of these phases, revealing structural inhomogeneity across the sample. Four-probe resistance measurements confirmed superconductivity with two distinct transitions: an onset at 244 K associated with the cubic phase and a second near 220 K linked to the hexagonal phase. Notably, resistance profiles collected from multiple current and voltage permutations showed variations in transition width and onset temperature that correlated with the spatial phase distribution. These findings demonstrate a direct connection between local structural domains and superconducting behavior.

Materials science↗

Understanding catalyst behavior during in situ heating through simultaneous secondary and transmitted electron imaging

In situ heating study via a simultaneous secondary electron (SE) and transmitted electron (TE) microscopy is extremely insightful because information from the surface (SE) and bulk (TE) can be readily obtained. The leached Au/Fe 2 O 3 catalyst has voids on the surface of Fe 2 O 3 . Upon heating to 500 °C, voids shrank and disappeared, while internal Au species diffused to the surface to form new nanoparticles. Heating in vacuum reduced Fe 2 O 3 to Fe 3 O 4 . Heating at 700 °C caused coalescence and growth of Au particles and formation of faceted Fe 3 O 4 surfaces. We achieved 1.1 nm resolution in SE imaging during in situ heating.

36 MATERIALS SCIENCE↗

Effects of Hydrogen Redistribution at High Temperatures in Yttrium Hydride Moderator Material

We report advanced materials development, manufacturing, and modeling capabilities for innovative reactor designs support nuclear security and mission-focused science through enhanced technology for safer and more efficient and secure production of nuclear energy. The high temperature moderator material yttrium hydride poses a significant enhancement in small reactor design by thermalizing (slowing down) neutrons and decreasing the required fuel mass for a system. The research presented here supports understanding hydrogen distribution in yttrium hydride through: (1) the development of neutron-based hydrogen imaging and crystallographic characterization that allows us to understand fundamental diffraction behaviors and to observe changes in hydrogen distribution as a function of temperature and (2) subsequent neutron multiplication (reactivity) effects of changes in hydrogen distribution using measurement-based cross sections in a sample microreactor design. The main conclusions from the work are that: (1) hydrogen does not redistribute significantly below temperatures of 800°C in yttrium hydride and (2) hydrogen redistribution affects the reactivity slightly but not significantly.

36 MATERIALS SCIENCE↗

The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement

Purpose of Review: Multimodality imaging is integral for diagnosis, procedural guidance, and follow-up of patients undergoing transcatheter aortic valve replacement (TAVR). In this review, we provide an overview of the role of each imaging modality and highlight technical considerations and pitfalls. We also address current controversies and new developments in the field. Recent Findings: Echocardiography remains the primary imaging modality for diagnosis of aortic stenosis and intraprocedural guidance for TAVR, but computed tomography (CT) imaging has supplanted echocardiography for annular sizing and access site evaluation. Magnetic resonance imaging (MRI) shows promise in targeted patient populations. Refined parameters and guidelines for valve sizing and paravalvular regurgitation have sought to standardize these complex assessments. Summary: Multimodality imaging remains critical to the success of TAVR, but its role has evolved over time. Understanding the applications, strengths, and limitations of each imaging modality is a crucial skill for the modern structural imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meteorological image processing applications

Meteorologists at NASA's Goddard Space Flight Center are conducting an extensive program of research in weather and climate related phenomena. This paper focuses on meteorological image processing applications directed toward gaining a detailed understanding of severe weather phenomena. In addition, the paper discusses the ground data handling and image processing systems used at the Goddard Space Flight Center to support severe weather research activities and describes three specific meteorological studies which utilized these facilities.

Bracken, P. A.↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

SHERLOC: Results of the first 350 sols of operations

On February 18th 2021, the Perseverance rover landed in Jezero crater, Mars. This site was chosen because orbiter data analysis provides evidence that the crater hosted a stream-fed lake during the Martian Noachian period. The Octavia Butler landing site is located ~1.9 km east of the remnants of a river delta. Deltaic and lacustrine sediments can preserve biosignatures, making Jezero crater a prime target for Mars sample return science. One of the seven instruments on Perseverance’s science payload is SHERLOC –Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals. SHERLOC combines fluorescence and Raman spectroscopy with microscopic imaging to analyze surface material to better understand the history of the aqueous environments recorded in the rocks of Jezero crater and to search for potential biosignatures. SHERLOC imaging obtains high spatial resolution images of geological targets to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially resolved correlation of trace organic materials. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. In the first 300 sols, SHERLOC has analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater. SHERLOC has been able to identify phosphates, amorphous/microcrystalline silicate (AMS), olivine, sulfates, and carbonates in abraded patches in the green zone campaign within Jezero Crater Máaz and Séítah formations. Within these detections we have begun to tell the story of what this crater was like when it was full of liquid water over 3 billion years ago. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. We have identified multiple unique fluorescence signatures, within each of the abraded patches. The organic signatures have either been widely distributed over an extended area, which is probably due to planetary wide dust, or have spatially resolved locations that are collocated with different mineral signatures. Note: Additional information available on attachment.

L. W. Beegle↗

In Situ Laser Synthesis of Si Nanowires in the Dynamic TEM

Nanowires (NWs) are a crucial component in today's nanoscale devices and are vital to the further development of nanotechnology. To achieve reliable growth of NWs and uniform electronic properties, the specific mechanisms that control the structural development of NWs and the correlation between NWs and their nucleation and growth processes must be examined. Because imaging is not possible in Chemical Vapor Deposition (CVD) chambers, in situ transmission electron microscope (TEM) based growth methods provide a method for characterizing NW evolution. In this paper, we describe a new method of in situ synthesis and imaging of NWs using laser-assisted growth inside a TEM. The vapor-liquid solid (VLS) growth mechanism (Figure 1), first described by Wagner and co-workers, is a widely accepted description of how many 1D nanostructures are formed. VLS and similar models have been applied to such methods as hybrid pulsed-laser ablation/chemical vapor deposition (PLA/CVD) and laser assisted NW growth at elevated temperatures, in which a pulsed laser ablates a target with gas flowing through the reaction chamber held at elevated temperature. These methods have successfully produced semiconductor and conducting oxide NWs with size control determined by the catalyst droplet diameter. The VLS description of NW growth is a widely accepted model, but the exact role of vapor species and its interaction with the catalyst particle is not fully understood. For example, NW growth has been observed to occur far below predicted eutectic temperatures, which suggests that alternative mechanisms such as solid-liquid-solid growth (SLS) may play a role. Many NW fabrication techniques preclude direct in situ characterization of the growth process. Because of this need for direct observation during growth, TEM-based NW growth methods have become increasingly popular. Though progress has been made in the study of the VLS mechanism of NW growth using in situ TEM, conventional in situ growth experiments are limited by the standard video frame rate ({approx}30 Hz). Because of this limitation, relationships between reactant incorporation and transport, catalyst-wire interface development, and wire growth texture remain somewhat unclear. Moreover, laser-assisted phenomena (PLA or PLA/CVD) cannot be studied with conventional in situ TEM, which is typically performed with environmental TEM techniques using resistive heating. A novel form of in situ TEM for the study of NW growth by laser-assisted techniques is described in this paper. Here we present an in situ method for PLA synthesis of 1D nanostructures using the dynamic transmission electron microscope (DTEM)[18,19] that will permit the details of laser-assisted NW synthesis to be elucidated. The DTEM, schematically shown in Figure 2, consists of a TEM column (JEOL 2000FX) to which a pulsed Nd:YAG laser, labeled 'hydrodrive laser' in Fig. 2, is added. This laser is incident directly on the sample and can be operated at 1064, 532 or 355nm. The direct delivery of energy initiates a phase change or reaction that is investigated in situ during the experiment. Thus, the microscope can be used to fabricate NWs while simultaneously characterizing the reaction products created by each laser pulse. A second pulsed laser (15-ns-duration frequency-quintupled Nd:YLF) added to the column (labeled 'cathode laser' in figure 2) enables operation in both a pulsed photoemission and conventional thermionic continuous-wave (CW) electron beam imaging modes.[19] The pulsed mode's nanosecond-scale imaging capability greatly exceeds the {approx}30 Hz time resolution of conventional in situ TEM and can potentially provide a detailed understanding of NW growth. Time-resolved imaging experiments aimed at capturing the intermediate states at nanosecond time scales in PLA NW growth are underway and will be addressed in a future publication. In this paper, we present results obtained using in situ imaging in conventional CW imaging mode, but taking advantage of the DTEM's in situ laser drive capability. Specifically, we will present the first results using the sample ('hydro-drive') laser at 355nm to stimulate the growth of the nanostructures, therefore revealing the DTEM as a tool for in situ imaging of nanostructure synthesis (see the experimental section for details of the NW synthesis procedure).

36 MATERIALS SCIENCE↗

MO-FG-BRD-03: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: EM Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-00: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-04: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: MR Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

The Cosmic Microwave Background: Detection and Interpretation of the First Light

A host of astrophysical observations suggest the early Universe was incredibly hot, dense, and homogeneous. A powerful and useful probe of this epoch is provided by the relic radiation, which we refer to today as the Cosmic Microwave Background (CMB). Precision maps of this light contain the earliest glimpse of the Universe after the Big Bang and signatures of the evolution of its contents. By exploiting these clues, constraints on the age, mass density, detailed composition, and geometry of the Universe can be made. A brief survey of the evolution of the radiometric and polarimetric imaging systems used in advancing our understanding of the early Universe will be reviewed. A survey of detector technologies, instrumentation techniques, and experimental challenges encountered in these efforts will be presented.

polarimetric imaging systems↗

MO-FG-BRD-01: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: Introduction and KV Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-02: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: MV Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗