Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

OPTIMAL LINEAR IMAGE COMBINATION

A simple, yet general, formalism for the optimized linear combination of astrophysical images is constructed and demonstrated. The formalism allows the user to combine multiple undersampled images to provide oversampled output at high precision. The proposed method is general and may be used for any configuration of input pixels and point spread function; it also provides the noise covariance in the output image along with a powerful metric for describing undesired distortion to the image convolution kernel. The method explicitly provides knowledge and control of the inevitable compromise between noise and fidelity in the output image. We present a first prototype implementation of the method, outlining the steps taken to generate an efficient algorithm. This implementation is then put to practical use in reconstructing fully sampled output images using simulated, undersampled input exposures that are designed to mimic the proposed Wide-field InfraRed Survey Telescope (WFIRST). We examine results using randomly rotated and dithered input images, while also assessing better-known 'ideal' dither patterns: comparing results, we illustrate the use of the method as a survey design tool. Finally, we use the method to test the robustness of linear image combination when subjected to practical realities such as missing input pixels and focal plane plate scale variations.

79 ASTRONOMY AND ASTROPHYSICS↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

SU-E-T-292: Dosimetric Advantage of Prone Breast Radiotherapy for Korean Left-Sided Breast Cancer Patients

Purpose: To evaluate the dosimetric benefit of prone breast radiotherapy for Korean left-sided early-stage breast cancer patients who have relatively small breast Methods: From April to June, 2014, 10 left-sided breast cancer patients received the whole breast irradiation in prone position after partial mastectomy with sentinel lymph node biopsy or axillary lymph node dissection. All patients were pTmi-2N0-1mi. Each patient underwent two computed tomoradiography (CT) simulations in supine and prone positions. The whole breast, ipsilateral lung, heart, and left anterior descending coronary artery (LAD) were contoured on each simulation CT images, and then tangential-fields treatment plan in each position was designed for the whole breast irradiation with the total dose of 50 Gy in 2 Gy fractions. Dose-volume histograms of two setups were compared for target coverage and radiation dose to normal organs with Wilcoxon signed rank tests. Results: The median age of patients was 47 years (range, 37 to 53). The median chest size was 82.5 cm (range, 75 to 90) and bra cup size was A in 4, B in 4, and C in 2 patients. The radiation dose to the whole breast was similar when comparing mean dose (Dmean) and dose covering 95% of the breast volume, but maximum dose (Dmax) of breast was higher in supine (median 52.3 vs. 52.7 Gy, p=0.013). Prone position reduced significantly the radiation dose in ipsilateral lung, heart, and LAD by median 5.7, 1.1, and 6.9 Gy of Dmean (p=0.005, 0.007, and 0.005) and 28.2, 18.8, and 35.0 Gy of Dmax (p=0.005, 0.005, and 0.007), respectively. Conclusion: Prone breast radiotherapy could be beneficial for Korean breast cancer patients since it substantially spared normal organs while achieving adequate coverage of the breast tissue. Further prospective study is required to validate the potential benefit of prone breast radiotherapy.

60 APPLIED LIFE SCIENCES↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Toward in vivo lung's tissue incompressibility characterization for tumor motion modeling in radiation therapy

Purpose: A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Estimating lung tissue incompressibility parameter variations resulting from air content variation throughout respiration is critical for computer assisted tumor motion tracking. Continuous tumor motion is a major challenge in lung cancer radiotherapy, especially with external beam radiotherapy. If not accounted for, this motion may lead to areas of radiation overdosage for normal tissue. Given the unavailability of imaging modality that can be used effectively for real-time lung tumor tracking, computer assisted approach based on tissue deformation estimation can be a good alternative. This approach involves lung biomechanical model where its fidelity depends on input tissue properties. This investigation shows that considering variable tissue incompressibility parameter is very important for predicting tumor motion accurately, hence improving the lung radiotherapy outcome. Methods: First, an in silico lung phantom study was conducted to demonstrate the importance of employing variable Poisson's ratio for tumor motion predication. After it was established that modeling this variability is critical for accurate tumor motion prediction, an optimization based technique was developed to estimate lung tissue Poisson's ratio as a function of respiration cycle time. In this technique, the Poisson's ratio and lung pressure value were varied systematically until optimal values were obtained, leading to maximum similarity between acquired and simulated 4D CT lung images. This technique was applied in an ex vivo porcine lung study where simulated images were constructed using the end exhale CT image and deformation fields obtained from the lung's FE modeling of each respiration time increment. To model the tissue, linear elastic and Marlow hyperelastic material models in conjunction with variable Poisson's ratio were used. Results: The phantom study showed that the tumor motion trajectory and its final locations obtained from simulations with and without considering tissue incompressibility variation were very different. For example, tumor displacements in the z direction were -11.23 and -38.10 mm obtained with the Marlow hyperelastic material model in conjunction with constant and variable Poisson's ratio, respectively. By comparing the acquired 4D-CT image sequence of the porcine lung with their image sequence counterparts obtained from the hyperelastic model with constant and variable Poisson's ratio, it was shown that using variable tissue incompressibility reduced errors significantly in tumor motion prediction. Conclusions: This investigation demonstrates the importance of incompressibility variation estimation and utilization for accurate tumor tracking in computer assisted lung external beam radiation therapy. An optimization framework was developed to estimate a Poisson's ratio function in terms of respiration cycle time using experimental image data of the lung. Utilizing this function along with respiratory system FE modeling may lead to more effective tumor targeting, hence potentially improving the outcome of lung external beam radiation therapy techniques. This is particularly true for stereotactic body radiation therapy where only one or a few fraction treatments are applied, precluding the possibility of averaging out dosimetric deviations introduced by the respiratory motion.

60 APPLIED LIFE SCIENCES↗

Iterative Reconstruction of Coded Source Neutron Radiographs

Use of a coded source facilitates high-resolution neutron imaging through magnifications but requires that the radiographic data be deconvolved. A comparison of direct deconvolution with two different iterative algorithms has been performed. One iterative algorithm is based on a maximum likelihood estimation (MLE)-like framework and the second is based on a geometric model of the neutron beam within a least squares formulation of the inverse imaging problem. Simulated data for both uniform and Gaussian shaped source distributions was used for testing to understand the impact of non-uniformities present in neutron beam distributions on the reconstructed images. Results indicate that the model based reconstruction method will match resolution and improve on contrast over convolution methods in the presence of non-uniform sources. Additionally, the model based iterative algorithm provides direct calculation of quantitative transmission values while the convolution based methods must be normalized base on known values.

Santos-Villalobos, Hector J↗

Advanced Imaging Optics Utilizing Wavefront Coding

Image processing offers a potential to simplify an optical system by shifting some of the imaging burden from lenses to the more cost effective electronics. Wavefront coding using a cubic phase plate combined with image processing can extend the system's depth of focus, reducing many of the focus-related aberrations as well as material related chromatic aberrations. However, the optimal design process and physical limitations of wavefront coding systems with respect to first-order optical parameters and noise are not well documented. We examined image quality of simulated and experimental wavefront coded images before and after reconstruction in the presence of noise. Challenges in the implementation of cubic phase in an optical system are discussed. In particular, we found that limitations must be placed on system noise, aperture, field of view and bandwidth to develop a robust wavefront coded system.

97 MATHEMATICS AND COMPUTING↗

Intrinsic Defect-Induced Local Semiconducting-to-Metallic Regions Within Monolayer 1T-TiS2 Displayed by First-Principles Calculations and Scanning Tunneling Microscopy

Using density functional theory (DFT) and scanning tunneling microscopy (STM), the intrinsic point defects, formation energy, and electronic structure of 1T-TiS2 were investigated. Defect systems include single-atom vacancies, interstitial and adatom additions, and direct atomic substitution. Using a collective approach for analyzing realistic systems for point defect investigation, we provide a more straightforward comparison to the experimental measurements, reproducing more realistic environmental conditions related to thin film growth. STM images are compared to computationally simulated electron density images to identify specific geometries that result from favorable point defects. DFT suggests that titanium interstitials are the most energetically favorable intrinsic defect, and sulfur vacancies are more likely to form than titanium vacancies within this realistic analysis, which is in agreement with STM data. A pristine, stoichiometric monolayer system is calculated to have a direct band gap of 0.422 eV, which varies based on local point defects. Local semiconducting-to-metallic electronic transitions are predicted to occur based on the presence of Ti interstitials.

Keeney, P. J.↗

SU-E-J-201: Investigation of MRI Guided Proton Therapy

Purpose: Image-guided radiation therapy has been employed for cancer treatment to improve the tumor localization accuracy. Radiation therapy with proton beams requires more on this accuracy because the proton beam has larger uncertainty and dramatic dose variation along the beam direction. Among all the image modalities, magnetic-resonance image (MRI) is the best for soft tissue delineation and real time motion monitoring. In this work, we investigated the behavior of the proton beam in magnetic field with Monte Carlo simulations. Methods: A proton Monte Carlo platform, TOPAS, was used for this investigation. Dose calculations were performed with this platform in a 30cmx30cmx30cm water phantom for both pencil and broad proton beams with different energies (120, 150 and 180MeV) in different magnetic fields (0.5T, 1T and 3T). The isodose distributions, dose profiles in lateral and beam direction were evaluated. The shifts of the Bragg peak in different magnetic fields for different proton energies were compared and the magnetic field effects on the characters of the dose distribution were analyzed. Results: Significant effects of magnetic field have been observed on the proton beam dose distributions, especially for magnetic field of 1T and up. The effects are more significant for higher energy proton beam because higher energy protons travel longer distance in the magnetic field. The Bragg peak shift in the lateral direction is about 38mm for 180MeV and 11mm for 120MeV proton beams in 3T magnetic field. The peak positions are retracted back for 6mm and 2mm, respectively. The effect on the beam penumbra and dose falloff at the distal edge of the Bragg peak is negligible. Conclusion: Though significant magnetic effects on dose distribution have been observed for proton beams, MRI guided proton therapy is feasible because the magnetic effects on dose is predictable and can be considered in patient dose calculation.

60 APPLIED LIFE SCIENCES↗

Dark Energy Camera for Blanco

In order to make accurate measurements of dark energy, a system is needed to monitor the focus and alignment of the Dark Energy Camera (DECam) to be located on the Blanco 4m Telescope for the upcoming Dark Energy Survey. One new approach under development is to fit out-of-focus star images to a point spread function from which information about the focus and tilt of the camera can be obtained. As a first test of a new algorithm using this idea, simulated star images produced from a model of DECam in the optics software Zemax were fitted. Then, real images from the Mosaic II imager currently installed on the Blanco telescope were used to investigate the algorithm's capabilities. A number of problems with the algorithm were found, and more work is needed to understand its limitations and improve its capabilities so it can reliably predict camera alignment and focus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of contour images using optics of spiral beams

An approach is outlined to the recognition of contour images using computer technology based on coherent optics principles. A mathematical description of the recognition process algorithm and the results of numerical modelling are presented. The developed approach to the recognition of contour images using optics of spiral beams is described and justified. (image recognition)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstructing the exit wave of 2D materials in high-resolution transmission electron microscopy using machine learning

Reconstruction of the exit wave function is an important route to interpreting high-resolution transmission electron microscopy (HRTEM) images. Here we demonstrate that convolutional neural networks can be used to reconstruct the exit wave from a short focal series of HRTEM images, with a fidelity comparable to conventional exit wave reconstruction. We use a fully convolutional neural network based on the U-Net architecture, and demonstrate that we can train it on simulated exit waves and simulated HRTEM images of graphene-supported molybdenum disulphide (an industrial desulfurization catalyst). We then apply the trained network to analyse experimentally obtained images from similar samples, and obtain exit waves that clearly show the atomically resolved structure of both the MoS 2 nanoparticles and the graphene support. We also show that it is possible to successfully train the neural networks to reconstruct exit waves for 3400 different two-dimensional materials taken from the Computational 2D Materials Database of known and proposed two-dimensional materials.

2D materials↗

Quantitative magnetic imaging at the nanometer scale by ballistic electron magnetic microscopy

We demonstrate quantitative ballistic electron magnetic microscopy (BEMM) imaging of simple model Fe(001) nanostructures. We use in situ nanostencil shadow mask resistless patterning combined with molecular beam epitaxy deposition to prepare under ultra-high vacuum conditions nanostructured epitaxial Fe/Au/Fe/GaAs(001) spin-valves. In this epitaxial system, the magnetization of the bottom Fe/GaAs(001) electrode is parallel to the [110] direction, defining accurately the analysis direction for the BEMM experiments. The large hot-electron magnetoresistance of the Fe/Au/Fe/GaAs(001) epitaxial spin-valve allows us to image various stable magnetic configurations on the as-grown Fe(001) microstructures with a high sensitivity, even for small misalignments of both magnetic electrodes. The angular dependence of the hot-electron magnetocurrent is used to convert magnetization maps calculated by micromagnetic simulations into simulated BEMM images. The calculated BEMM images and magnetization rotation profiles show quantitative agreement with experiments and allow us to investigate the magnetic phase diagram of these model Fe(001) microstructures. Finally, magnetic domain reversals are observed under high current density pulses. This opens the way for further BEMM investigations of current-induced magnetization dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of coronal loop diagnostics using realistic three-dimensional hydrodynamic models

Many different techniques have been used to characterize the plasma in the solar corona: density-sensitive spectral line ratios are used to infer the density, the evolution of coronal structures in different passbands is used to infer the temperature evolution, and the simultaneous intensities measured in multiple passbands are used to determine the emission measure distributions. All these analysis techniques assume that the intensity of the structures can be isolated through background subtraction. In this paper, we use simulated observations from a three-dimensional hydrodynamic simulation of a coronal active region to verify these diagnostics. The density and temperature from the simulation are used to generate images in several passbands and spectral lines. We identify loop structures in the simulated images and calculate the background. We then determine the density, temperature, and emission measure distribution as a function of time from the observations and compare these with the true temperature and density of the loop. We find that the overall characteristics of the temperature, density, and emission measure are recovered by the analysis methods, but the details are not. For instance, the emission measure curves calculated from the simulated observations are much broader than the true emission measure distribution, though the average temperature evolution is similar. These differences are due, in part, to a limitation of the analysis methods, but also to inadequate background subtraction.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗