WE-G-209-04: MRI

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID

Purpose: The purpose of this study was to validate the use of a cascaded linear system model for MV cone-beam CT (CBCT) using a multi-layer (MLI) electronic portal imaging device (EPID) and provide experimental insight into image formation. A validated 3D model provides insight into salient factors affecting reconstructed image quality, allowing potential for optimizing detector design for CBCT applications. Methods: A cascaded linear system model was developed to investigate the potential improvement in reconstructed image quality for MV CBCT using an MLI EPID. Inputs to the three-dimensional (3D) model include projection space MTF and NPS. Experimental validation was performed on a prototype MLI detector installed on the portal imaging arm of a Varian TrueBeam radiotherapy system. CBCT scans of up to 898 projections over 360 degrees were acquired at exposures of 16 and 64 MU. Image volumes were reconstructed using a Feldkamp-type (FDK) filtered backprojection (FBP) algorithm. Flat field images and scans of a Catphan model 604 phantom were acquired. The effect of 2×2 and 4×4 detector binning was also examined. Results: Using projection flat fields as an input, examination of the modeled and measured NPS in the axial plane exhibits good agreement. Binning projection images was shown to improve axial slice SDNR by a factor of approximately 1.4. This improvement is largely driven by a decrease in image noise of roughly 20%. However, this effect is accompanied by a subsequent loss in image resolution. Conclusion: The measured axial NPS shows good agreement with the theoretical calculation using a linear system model. Binning of projection images improves SNR of large objects on the Catphan phantom by decreasing noise. Specific imaging tasks will dictate the implementation image binning to two-dimensional projection images. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on-table motion information.

60 APPLIED LIFE SCIENCES↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Image transfer in photorefractive GaAs

Image transfer from one beam to the other using counterpropagation beam coupling in GaAs was demonstrated. Good image quality was achieved. The results also reveal that local birefringence due to the residual stress/strain field in the crystal can degrade the image quality.

Cheng, Li-Jen↗

Context dependent anti-aliasing image reconstruction

Image Reconstruction has been mostly confined to context free linear processes; the traditional continuum interpretation of digital array data uses a linear interpolator with or without an enhancement filter. Here, anti-aliasing context dependent interpretation techniques are investigated for image reconstruction. Pattern classification is applied to each neighborhood to assign it a context class; a different interpolation/filter is applied to neighborhoods of differing context. It is shown how the context dependent interpolation is computed through ensemble average statistics using high resolution training imagery from which the lower resolution image array data is obtained (simulation). A quadratic least squares (LS) context-free image quality model is described from which the context dependent interpolation coefficients are derived. It is shown how ensembles of high-resolution images can be used to capture the a priori special character of different context classes. As a consequence, a priori information such as the translational invariance of edges along the edge direction, edge discontinuity, and the character of corners is captured and can be used to interpret image array data with greater spatial resolution than would be expected by the Nyquist limit. A Gibb-like artifact associated with this super-resolution is discussed. More realistic context dependent image quality models are needed and a suggestion is made for using a quality model which now is finding application in data compression.

Beaudet, Paul R.↗

Localization of deformable tumors from short-arc projections using Bayesian estimation

Purpose: The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs. Methods: Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy{sup Registered-Sign} XVI system. Furthermore, a clinical prostate CBCT scan of a Varian{sup Registered-Sign} On-Board Imager{sup Registered-Sign} system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views). Results: The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10 Degree-Sign while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40 Degree-Sign . Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously. Conclusions: In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Passive Night Vision Sensor Comparison for Unmanned Ground Vehicle Stereo Vision Navigation

One goal of the "Demo III" unmanned ground vehicle program is to enable autonomous nighttime navigation at speeds of up to 10 m.p.h. To perform obstacle detection at night with stereo vision will require night vision cameras that produce adequate image quality for the driving speeds, vehicle dynamics, obstacle sizes, and scene conditions that will be encountered. This paper analyzes the suitability of four classes of night vision cameras (3-5 micrometer cooled FLIR, 8-12 micrometer cooled FLIR, 8-12 micrometer uncooled FLIR, and image intensifiers) for night stereo vision, using criteria based on stereo matching quality, image signal to noise ratio, motion blur and synchronization capability. We find that only cooled FLIRs will enable stereo vision performance that meets the goals of the Demo III program for nighttime autonomous mobility.

Owens, Ken↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Bandwidth compression of synthetic aperture radar imagery by quantization of raw radar data

A study is made of the effects of quantization of the radar returns transmitted from aircraft or spacecraft employing a synthetic aperture radar system. The study is based on the output images obtained after one-bit, two-bit, and eight-bit quantizations and comparing the results to ground truth. In this way the degradation resulting from data or bandwidth reduction is determined. Quantization is evaluated in terms of crater scene, number of looks, and transmission error rate. It is found that two-bit quantization of raw radar data from homogeneous scenes processed to 32 looks yields nearly all the details of the original. One-bit quantization of raw radar data from homogeneous scenes processed to 32 looks yields a good visual representation of the scene but some fine detail is lost and the absolute reflectivity level is not reliable. Image quality is observed to improve with more looks and video and intermediate frequency quantization are not distinguishable even for one-bit quantizations. Image quality is not influenced by bit error rates less than about 2 to the -7th power.

Lipes, R. G.↗

Faraday anomalous dispersion optical filters

The effect of Faraday anomalous dispersion optical filters on infrared and blue transitions of some alkali atoms is calculated. A composite system is designed to further increase the background noise rejection. The measured results of the solar background rejection and image quality through the filter are presented. The results show that the filter may provide high transmission and high background noise rejection with excellent image quality.

Shay, T. M.↗

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗

MO-FG-204-08: Optimization-Based Image Reconstruction From Unevenly Distributed Sparse Projection Views

Purpose: Optimization-based reconstruction has been proposed and investigated for reconstructing CT images from sparse views, as such the radiation dose can be substantially reduced while maintaining acceptable image quality. The investigation has so far focused on reconstruction from evenly distributed sparse views. Recognizing the clinical situations wherein only unevenly sparse views are available, e.g., image guided radiation therapy, CT perfusion and multi-cycle cardiovascular imaging, we investigate the performance of optimization-based image reconstruction from unevenly sparse projection views in this work. Methods: The investigation is carried out using the FORBILD and an anthropomorphic head phantoms. In the study, 82 views, which are evenly sorted out from a full (360°) axial CT scan consisting of 984 views, form sub-scan I. Another 82 views are sorted out in a similar manner to form sub-scan II. As such, a CT scan with sparse (164) views at 1:6 ratio are formed. By shifting the two sub-scans relatively in view angulation, a CT scan with unevenly distributed sparse (164) views at 1:6 ratio are formed. An optimization-based method is implemented to reconstruct images from the unevenly distributed views. By taking the FBP reconstruction from the full scan (984 views) as the reference, the root mean square (RMS) between the reference and the optimization-based reconstruction is used to evaluate the performance quantitatively. Results: In visual inspection, the optimization-based method outperforms the FBP substantially in the reconstruction from unevenly distributed, which are quantitatively verified by the RMS gauged globally and in ROIs in both the FORBILD and anthropomorphic head phantoms. The RMS increases with increasing severity in the uneven angular distribution, especially in the case of anthropomorphic head phantom. Conclusion: The optimization-based image reconstruction can save radiation dose up to 12-fold while providing acceptable image quality for advanced clinical applications wherein only unevenly distributed sparse views are available. Research Grants: W81XWH-12-1-0138 (DoD), Sinovision Technologies.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models

Purpose: To develop a unique method to incorporate the dynamics of contrast-medium propagation into the anthropomorphic phantom, to generate a five-dimensional (5D) patient model for multimodality imaging studies. Methods: A compartmental model of blood circulation network within the body was embodied into an extended cardiac-torso (4D-XCAT) patient model. To do so, a computational physiologic model of the human cardiovascular system was developed which includes a series of compartments representing heart, vessels, and organs. Patient-specific cardiac output and blood volume were used as inputs influenced by the weight, height, age, and gender of the patient's model. For a given injection protocol and given XCAT model, the contrast-medium transmission within the body was described by a series of mass balance differential equations, the solutions to which provided the contrast enhancement-time curves for each organ; thereby defining the tissue materials including the contrastmedium within the XCAT model. A library of time-dependent organ materials was then defined. Each organ in each voxelized 4D-XCAT phantom was assigned to a corresponding time-varying material to create the 5D-XCAT phantom in which the fifth dimension is blood/contrast-medium within the temporal domain. Results: The model effectively predicts the time-varying concentration behavior of various contrast-medium administration in each organ for different patient models as function of patient size (weight/height) and different injection protocol factors (injection rate and pattern, iodine concentration or volume). The contrast enhanced XCAT patient models was developed based on the concentration of iodine as a function of time after injection. Conclusion: Majority of medical imaging systems take advantage of contrast-medium administration in terms of better image quality, the effect of which was ignored in previous optimization studies. The study enables a comprehensive optimization of contrast administration both in terms of image quality and radiation dose, and can be used in different modalities such as CT, MRI, and ultrasound.

60 APPLIED LIFE SCIENCES↗

Influence of alignment and surface defects on the performance of X-ray telescopes

The effects of misalignment and surface deformations on the image quality of a grazing incidence telescope with six nested subsystems are investigated. The axial rms-spot size serves as a measure for the image quality. The surface deformations are simulated by ellipsoidal and sinusoidal deviations from the ideal surface. Misalignments are tilts, decenters, and despaces of the individual elements. The effects of each type of defect are analyzed in a single two-element system. The full nested system is then analyzed in the presence of all possible defects on all 12 elements, whereby the magnitude of the defects is randomized within a given upper limit.

Korsch, D.↗

SNPP VIIRS Spectral Bands Co-Registration and Spatial Response Characterization

The Visible Infrared Imager Radiometer Suite (VIIRS) instrument onboard the Suomi National Polar‐orbiting Partnership (SNPP) satellite was launched on 28 October 2011. The VIIRS has 5 imagery spectral bands (I-bands), 16 moderate resolution spectral bands (M-bands) and a panchromatic day/night band (DNB). Performance of the VIIRS spatial response and band-to-band co-registration (BBR) was measured through intensive pre-launch tests. These measurements were made in the non-aggregated zones near the start (or end) of scan for the I-bands and M-bands and for a limited number of aggregation modes for the DNB in order to test requirement compliance. This paper presents results based on a recently re-processed pre-launch test data. Sensor (detector) spatial impulse responses in the scan direction are parameterized in terms of ground dynamic field of view (GDFOV), horizontal spatial resolution (HSR), modulation transfer function (MTF), ensquared energy (EE) and integrated out-of-pixel (IOOP) spatial response. Results are presented for the non-aggregation, 2-sample and 3-sample aggregation zones for the I-bands and M-bands, and for a limited number of aggregation modes for the DNB. On-orbit GDFOVs measured for the 5 I-bands in the scan direction using a straight bridge are also presented. Band-to-band co-registration (BBR) is quantified using the prelaunch measured band-to-band offsets. These offsets may be expressed as fractions of horizontal sampling intervals (HSIs), detector spatial response parameters GDFOV or HSR. BBR bases on HSIs in the non-aggregation, 2-sample and 3-sample aggregation zones are presented. BBR matrices based on scan direction GDFOV and HSR are compared to the BBR matrix based on HSI in the non-aggregation zone. We demonstrate that BBR based on GDFOV is a better representation of footprint overlap and so this definition should be used in BBR requirement specifications. We propose that HSR not be used as the primary image quality indicator, since we show that it is neither an adequate representation of the size of sensor spatial response nor an adequate measure of imaging quality.

Suomi NPP VIIRS↗

The detective quantum efficiency of photon-counting x-ray detectors using cascaded-systems analyses

Purpose: Single-photon counting (SPC) x-ray imaging has the potential to improve image quality and enable new advanced energy-dependent methods. The purpose of this study is to extend cascaded-systems analyses (CSA) to the description of image quality and the detective quantum efficiency (DQE) of SPC systems. Methods: Point-process theory is used to develop a method of propagating the mean signal and Wiener noise-power spectrum through a thresholding stage (required to identify x-ray interaction events). The new transfer relationships are used to describe the zero-frequency DQE of a hypothetical SPC detector including the effects of stochastic conversion of incident photons to secondary quanta, secondary quantum sinks, additive noise, and threshold level. Theoretical results are compared with Monte Carlo calculations assuming the same detector model. Results: Under certain conditions, the CSA approach can be applied to SPC systems with the additional requirement of propagating the probability density function describing the total number of image-forming quanta through each stage of a cascaded model. Theoretical results including DQE show excellent agreement with Monte Carlo calculations under all conditions considered. Conclusions: Application of the CSA method shows that false counts due to additive electronic noise results in both a nonlinear image signal and increased image noise. There is a window of allowable threshold values to achieve a high DQE that depends on conversion gain, secondary quantum sinks, and additive noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An accelerated threshold-based back-projection algorithm for Compton camera image reconstruction

Purpose: Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors present a fast and simple method by which to generate an initial back-projected image from acquired CCI data, suitable for use in a filtered back-projection algorithm or as a starting point for iterative reconstruction algorithms, and compare its performance to the current state of the art. Methods: Each detector event in a CCI system describes a conical surface that includes the true point of origin of the detected photon. Numerical image reconstruction algorithms require, as a first step, the back-projection of each of these conical surfaces into an image space. The algorithm presented here first generates a solution matrix for each slice of the image space by solving the intersection of the conical surface with the image plane. Each element of the solution matrix is proportional to the distance of the corresponding voxel from the true intersection curve. A threshold function was developed to extract those pixels sufficiently close to the true intersection to generate a binary intersection curve. This process is repeated for each image plane for each CCI detector event, resulting in a three-dimensional back-projection image. The performance of this algorithm was tested against a marching algorithm known for speed and accuracy. Results: The threshold-based algorithm was found to be approximately four times faster than the current state of the art with minimal deficit to image quality, arising from the fact that a generically applicable threshold function cannot provide perfect results in all situations. The algorithm fails to extract a complete intersection curve in image slices near the detector surface for detector event cones having axes nearly parallel to the image plane. This effect decreases the sum of the image, thereby also affecting the mean, standard deviation, and SNR of the image. All back-projected events associated with a simulated point source intersected the voxel containing the source and the FWHM of the back-projected image was similar to that obtained from the marching method. Conclusions: The slight deficit to image quality observed with the threshold-based back-projection algorithm described here is outweighed by the 75% reduction in computation time. The implementation of this method requires the development of an optimum threshold function, which determines the overall accuracy of the method. This makes the algorithm well-suited to applications involving the reconstruction of many large images, where the time invested in threshold development is offset by the decreased image reconstruction time. Implemented in a parallel-computing environment, the threshold-based algorithm has the potential to provide real-time dose verification for radiation therapy.

60 APPLIED LIFE SCIENCES↗