Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Daytime urban heat stress in North America reduced by irrigation

There is considerable uncertainty regarding the impact of irrigation on heat stress, partly stemming from the choice of heat stress index. Moreover, existing simulations are at scales that cannot appropriately resolve population centres or clouds and thus the potential for human impacts. Using multi-year convection-permitting and urban-resolving regional climate simulations, we demonstrate that irrigation alleviates summertime heat stress across more than 1,600 urban clusters in North America. This holds true for most physiologically relevant heat stress indices. The impact of irrigation varies by climate zone, with more notable irrigation signals seen for arid urban clusters that are situated near heavily irrigated fields. Through a component attribution framework, we show that irrigation-induced changes in wet-bulb temperature, often used as a moist heat stress proxy in the geosciences, exhibit an opposite sign to the corresponding changes in wet bulb globe temperature—a more complete index for assessing both indoor and outdoor heat risk—across climate zones. In contrast, the local changes in both wet-bulb and wet bulb globe temperature due to urbanization have the same sign. Here, our results demonstrate a complex relationship between irrigation and heat stress, highlighting the importance of using appropriate heat stress indices when assessing the potential for population-scale human impacts.

54 ENVIRONMENTAL SCIENCES↗

Revisiting heat treatment and surface activation of GaAs photocathodes: In situ studies using scanning tunneling microscopy and photoelectron spectroscopy

The lifetime of GaAs photocathodes in polarized electron guns is limited due to the delicate activation layer. An atomically clean and smooth GaAs surface is needed to deposit a robust activation layer, such as Cs 2 Te, with longer lifetime compared to traditional (Cs,O) activation. A previous experiment with Cs 2 Te activation on GaAs used heat cleaning temperatures around 400°C to avoid an increase in surface roughness [Bae et al., Appl. Phys. Lett. 112, 154101 (2018)]. Furthermore, high-temperature heat cleaning around 580°C, which results in a relatively contamination-free surface, could be one possible way to improve quantum efficiency. However, one should be cautious about surface roughness degradation during high-temperature heat cleaning. In this paper, we report results of surface roughness measurements on native, heat cleaned, and (Cs,O) activated GaAs photocathodes under vacuum. The results, measured by ultrahigh vacuum scanning tunneling microscopy, show that the surface roughness improves as the heat cleaning temperature is increased, by at least a factor of three for 580°C heat cleaning, compared to the native sample. Activation with (Cs,O) is shown to increase surface roughness by a factor of four compared to a 580°C heat cleaned sample. This confirms that high-temperature heat cleaning can be useful for depositing good quality robust activation layers on GaAs. Additionally, we also report chemical analysis for each step of preparation for p-doped GaAs photocathodes using X-ray photoelectron spectroscopy (XPS), angle-resolved XPS, and ultraviolet photoelectron spectroscopy. Our results indicate that the (Cs,O) activation layer forms a sandwich structure consists of Cs and oxygen. We found no formation of any specific compound such as Cs 2 O or Cs 11 O 3 .

43 PARTICLE ACCELERATORS↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Pedestal formation via different trajectories in the stability space in response to the timing scan of neutral beam heating in DIII-D

The frequency of type-I ELMs decreases as the initiation of the neutral beam injection (NBI) heating is delayed with respect to the time when plasma current (I p ) reaches flat-top in the ITER Baseline Scenario discharges in DIII-D. Henceforth, the time gap between the NBI initiation and I p flat-top will be referred to as “heating delay.” As the heating delay is modified, pedestal formation follows different trajectories in the edge current density–pedestal pressure gradient (j edge -∇p e ped ) space from the L-H transition toward the first ELM event. During the stationary phase after the first ELM, the ELM frequency (f ELM ) decreases by a factor of ~2 as the heating delay is increased. A longer pedestal recovery time in the inter-ELM period is observed for the low f ELM discharges as compared to the high f ELM discharges. Both low and high f ELM discharges show nearly identical profiles of electron density and temperature and have a similar MHD stability just before an ELM crash. However, a marked difference is observed in the magnetic spectrogram of the high and low f ELM discharges in response to the variation in the heating delay. The main difference is in the 200–400 kHz range of the magnetic spectra. A quasi-coherent mode (QCM) at 220 kHz and weaker broadband fluctuations are observed in the high f ELM discharges, while only strong broadband fluctuations are prevalent in the low f ELM discharges. ELM-synchronized analysis shows that the time evolution of these modes is different for the high and low f ELM discharges. The localization of both these modes is confirmed at the maximum gradient region of the pedestal. We hypothesize that these modes cause important pedestal transport and that the difference in the pedestal recovery of the high and low f ELM discharges is a result of the difference in transport driven by these modes, as they change with changes in the heating delay. It is demonstrated experimentally for the first time that discharges with similar pedestal parameters can carry the history of the heating delay into the stationary phase and that changes in turbulent-driven transport are a likely cause of changes in f ELM observed with variations of heating delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗

Numerical-heating effects in atmospheric pressure streamer discharges simulated with a PIC code

Artificial heating in plasma simulations is a well-known phenomenon which occurs when, among other things, the Debye length is poorly resolved by the simulation mesh. Here, in this work, the degree to which numerical-heating occurs during a simulation of a nanosecond atmospheric pressure streamer discharge is examined. The streamer is simulated using a two-dimensional finite-element, particle-in-cell code Empire, which uses direct simulation Monte Carlo for binary particle interactions. Initially, an estimate of the numerical-heating rate applied to Empire is performed using a simple plasma model. Second, a positive atmospheric pressure streamer discharge simulation is performed to study the effects of numerical heating on plasma density, electron temperature, and streamer velocity. The nominal Debye length is approximately 1 μm and the amount of numerical heating introduced in the simulation is varied by using mesh sizes ranging from 2 μm to 20 μm. A measurable numerical heating quantity is proposed that can be used to estimate the appropriate element size and quantify the numerical-heating that can be expected over the simulation time for an atmospheric pressure streamer. In conclusion while Δx/λ D violations can be an issue it is not likely to be an issue with streamer discharges that are temporally short and occur in environments where collision frequencies are high. This result validates the rationale of grid size choices for a large amount of previously published works where Δx/λ D violation was not clearly addressed. Primary finding of this work is that numerical heating is of minor concern for plasma simulations where electron–neutral collisions are numerous such that multiple collisions can occur within a single plasma period.

Nikic, Dejan [University of New Mexico, Albuquerqu↗

Contribution of the Hydroxyl Group on Interfacial Heat Conduction of Monohydric Alcohols: A Molecular Dynamics Study

Monohydric alcohols have been used as promising phase change materials (PCMs) for low-temperature latent heat storage. However, the heat storage/retrieval rates are limited due to the low thermal conductivity of such alcohols. In this work, nonequilibrium molecular dynamics (NEMD) simulations were performed to study the microscopic heat conduction in example monohydric alcohols, i.e., 1-dodecanol (C12H26O), 1-tetradecanol (C14H30O), and 1-hexadecanol (C16H34O). A simplified ideal crystal model was proposed to exploit the potential for improving the thermal conductivity of monohydric alcohols. The effect of ideal crystalline structures, especially the contribution of the hydroxyl group, on the microscopic heat conduction process was analyzed. The thermal conductivity of the ideal crystals of the various monohydric alcohols was predicted to be more than twice as compared to that of their respective solids. The major thermal resistance in the ideal crystals was found around the molecular interfaces, as a result of the excellent heat conduction performance along the linear molecular chains. The calculated vibrational density of states (VDOS) and interfacial heat transfer were then investigated. When the interfaces are surrounded by hydroxyl groups as walls, strong hydrogen bond (HB) interactions were observed. The interfacial heat transfer coefficient of the ideal crystalline structures of 1-tetradecanol was found to reach up to ~735.6 MW/m2 W. It was elucidated that the high interfacial heat transfer rate is clearly related to the stronger intermolecular interactions.

Engineering↗

Extending the Heat Index

The Heat Index is a widely used measure of apparent temperature that accounts for the effects of humidity using Steadman’s model of human thermoregulation. Steadman’s model, however, gives unphysical results when the air is too hot and humid or too cold and dry, leading to an undefined Heat Index. For example, at a relative humidity of 80%, the Heat Index is only defined for temperatures in the range of 288-304 K (59-88 degrees Fahrenheit). Here, Steadman’s thermoregulation model is extended to define the Heat Index for all combinations of temperature and humidity, allowing for an assessment of Earth’s future habitability. The extended Heat Index can be mapped onto physiological responses of an idealized human, such as heat exhaustion, heat stroke, and even heat death, providing an indication of regional health outcomes for different degrees of global warming.

54 ENVIRONMENTAL SCIENCES↗

Strong Red Noise Ocean Forcing on Atlantic Multidecadal Variability Assessed from Surface Heat Flux: Theory and Application

The role of ocean forcing on Atlantic multidecadal variability (AMV) is assessed from the (downward) heat flux–SST relation in the framework of a new stochastic climate theory forced by red noise ocean forcing. Previous studies suggested that atmospheric forcing drives SST variability from monthly to interannual time scales, with a positive heat flux–SST correlation, while heat flux induced by ocean processes can drive SST variability at decadal and longer time scales, with a negative heat flux–SST correlation. Here, first, we develop a theory to show how the sign of heat flux–SST correlation is affected by atmospheric and oceanic forcing with time scale. In particular, a red noise ocean forcing is necessary for the sign reversal of heat flux–SST correlation. Furthermore, this sign reversal can be detected equivalently in three approaches: the low-pass correlation at lag zero, the unfiltered correlation at long (heat flux) lead, and the real part of the heat flux–SST coherence. Second, we develop a new scheme in combination with the theory to assess the magnitude and time scale of the red noise ocean forcing for AMV in the GFDL SPEAR model (Seamless System for Prediction and Earth System Research) and observations. In both the model and observations, the ocean forcing on AMV is in general comparable with the atmospheric forcing, with a 90% probability greater than the atmospheric forcing in observations. In contrast to the white noise atmospheric forcing, the ocean forcing has a persistence time comparable or longer than a year, much longer than the SST persistence of ~3 months. This slow ocean forcing is associated implicitly with slow subsurface ocean dynamics.

54 ENVIRONMENTAL SCIENCES↗

EARLY HAWAIIANS AND VOLCANIC HEAT

This research serves as the first-known compilation of accounts of early Hawaiians using volcanic heat. Western explorers in the 1800s wrote about native Hawaiians near $K\bar{i}lauea$ Volcano using volcanic heat for cooking and bathing. They cooked their food wrapped in leaves underground or above a steam crack at Sulphur Banks, $K\bar{i}lauea$ Iki, and the $N\bar{a}pau$ Crater Trail. Early Hawaiians bathed in the warm waters of Waiwelawela for health. To confirm the presence of volcanic heat, this study used geothermal resource maps by the Hawai‘i Play Fairway project. According to a probability map for volcanic heat, the areas where Hawaiians used volcanic heat have a probability of volcanic heat of 0.8 to 1.0. On a map with temperatures of water wells, water wells close to where Hawaiians used volcanic heat have elevated temperatures. Historically, the areas where Hawaiians used volcanic heat experienced volcanic steam release, volcanic eruptions, and lava flows.

Geology↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

Improvements of SAM Heat Transfer Models for Molten Salt-Cooled Pebble Bed Reactors

To support the development and utilization of the SAM code for molten salt-cooled pebble bed reactor safety analyses and licensing, selected improvements were made to the one-dimensional system-level heat transfer modeling in SAM with the goal of better capturing heat transfer phenomena specific to these designs. In consideration of molten salt as a coolant, new models were introduced to capture the enhanced radiative heat transfer that must be considered at the higher working temperatures. Radiative heat transfer is handled not only between two structural surfaces, but also in combination between the surfaces and the molten salt fluid, which has a higher opacity and absorption of radiative heat as compared to water. Several examples of analytical verification of the new radiative heat transfer methods are included in this report. Additionally, convective heat transfer correlations were selected from literature and included in SAM to account for the enhanced heat transfer expected in pebble bed geometry flows. These correlations are verified and demonstrated in the present work with a reference FHR example.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technology Assessment on Low-Temperature Waste Heat Recovery in Industry

The purpose of this report is to discuss the magnitude of low-temperature waste heat available in the US manufacturing sector and to identify current and emerging low-temperature heat recovery technologies and equipment. The primary focus of the study is on the industries that produce the lowest-temperature waste heat: the chemical, primary metal, petroleum, nonmetallic mineral, fabricated metal, food, paper, and wood industries. In addition to identifying the waste streams, their characteristics, and currently available heat recovery technologies, the study also explored future research opportunities and economic barriers for recovery technology implementation. Special attention was given to applicable heat to power conversion technologies such as the organic Rankine cycle, thermoelectric conversion, and the supercritical CO 2 cycle. The study included investigations in research and new developments, including turbine and heat exchanger cost for waste heat to power systems, size, efficiency, and intermittency of waste heat streams.

30 DIRECT ENERGY CONVERSION↗

Modeling Molten Salt Spreading and Heat Transfer using MELTSPREAD – An Uncertainty Analysis

This report summarizes spreading and heat transfer results for molten salt pouring onto a flat stainless steel substrate that were calculated using MELTSPREAD to gain insight into bulk salt behavior during a molten salt spill accident. MELTSPREAD was developed at Argonne to model the one-dimensional flow and freezing behavior of molten corium and is being applied to model molten salts for the first time as part of this work. An uncertainty analysis of thermophysical properties and spill conditions was performed using MELTSPREAD to determine which properties and conditions have the greatest impact on model outcome. The model was run with and without the inclusion of decay heat. Eutectic FLiNaK was used as the salt composition because it is well-characterized and appropriate for model development. Small salt volumes were used for the initial model runs described in this report so that the model results can be compared to the results from ongoing experiments on molten salt spreading and heat transfer currently being conducted at Argonne at a benchtop scale. The spreading of a small volume of FLiNaK (50 mL) was found to be limited by the balance between the molten salt surface tension and gravity and not by freezing for the pour conditions and assumed mechanisms of heat transfer in the model. Heat transfer from the salt was highly inefficient to due to its low thermal conductivity, high heat capacity, and high heat of fusion and varying these properties had no effect on the spreading behavior. Changing the viscosity and density of the salt slightly affected the spreading behavior. Setting the salt surface tension to approximately zero to simulate the salt wetting the substrate had the greatest effect on the spreading behavior and this increased both the spreading velocity and overall spreading area. Including decay heat in the model had a significant effect on the long-term cooling behavior of the salt but had no effect on the overall spreading behavior. Future effort should involve modeling a larger volume of molten salt to represent a reactor case spill scenario because the spreading behavior of large volumes of salt may differ from the small volumes that were the focus of this document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗