Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Charting Hydropower's Role in the Next-Generation Grid

To build a 100% clean energy power sector, the United States is adding more energy storage and variable renewable energy sources, like solar power and wind energy, to the grid. Hydropower and pumped storage hydropower (PSH) can help with both. These technologies already play a key role in providing flexible, low-carbon electricity to the U.S. power grid, and this role will become even more valuable as that grid evolves. That's why researchers at the National Renewable Energy Laboratory (NREL) are analyzing how the U.S. electricity sector could invest in hydropower and PSH using new data and modeling capabilities.

HYDRO ENERGY↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

Digital data provenance for the power grid based on a Keyless Infrastructure Security Solution

In this work a data provenance system for grid-oriented applications is presented. The proposed Keyless Infrastructure Security Solution (KISS) provides mechanisms to store and maintain digital data fingerprints that can later be used to validate and assert data provenance using a time-based, hash tree mechanism. The developed solution has been designed to satisfy the stringent requirements of the modern power grid including execution time and storage necessities. Its applicability has been tested using a lab-scale, proof-of-concept deployment that secures an energy management system against the attack sequence observed on the 2016 Ukrainian power grid cyberattack. The results demonstrate a strong potential for enabling data provenance in a wide array of applications, including speed-sensitive applications such as those found in control room environments.

Sebastian Cardenas, David J.↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Nova Analysis: Holistically Valuing the Contributions of Residential Efficiency, Solar and Storage

Policies to address climate change and grid modernization, in combination with cost reductions and technological advancements in energy efficiency (EE) and distributed energy resources (DER), are driving rapid deployment of building electrification and energy efficiency retrofits, rooftop solar photovoltaics (PV), smart thermostats, smart water heaters, and battery energy storage. In residential buildings, there are multiple stakeholders (occupant, utility, aggregator, society at large) that are each focused on different value streams. This project uses a suite of metrics intended to all of these value streams to try to holistically analyze the benefits that come from solar, storage, and energy efficiency. To demonstrate the value of these metrics, a semi annual study was performed simulating hundreds of homes across the U.S. under several different upgrade scenarios.

14 SOLAR ENERGY↗

Commercialization of Pumped Storage Hydropower Technologies

Argonne National Laboratory and the National Laboratory of the Rockies were tasked by the U.S. Department of Energy’s Water Power Technology Office (WPTO) to conduct the Commercialization of Pumped Storage Hydropower Technologies study to investigate commercialization challenges faced by developers of pumped storage hydropower (PSH) projects and technologies by going beyond literature review to gather direct industry insights, lessons learned and best practices from interviews and webinars with industry specialists to create this report for PSH stakeholders and the general public. Researchers explored key challenges faced by PSH developers and innovators seeking to commercialize new technologies to improve PSH design, siting, construction, and operations. Along with highlighting challenges, the study sought to identify the best practices in developing and deploying new PSH projects and innovations. This report is designed to present insights, lessons learned, and best practices relevant to those with an interest in highlighting, informing, or advancing these PSH commercialization efforts. Along with highlighting challenges and best practices, the study sought to identify avenues by which DOE and national laboratories can help support and streamline PSH commercialization and project development processes.

13 HYDRO ENERGY↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗