Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Doppler lidar wind measurement with the edge technique

The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.

Korb, C. Laurence↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

Using Small Unmanned Aerial Systems (sUAS) and Helium Aerostats to Perform Far-Field Radiation Pattern Measurements of High-Frequency Antennas

A new methodology is described for performing near-free space far-field radiation pattern measurements of high frequency (HF) antennas utilizing small Unmanned Aerial Systems (sUAS) and helium-filled aerostat balloons for the radar antennas onboard NASA’s planned Europa Clipper mission to Jupiter’s moon Europa. Adapted from land-based measurements, this test methodology involves hoisting the antenna to be tested above the earth to minimize ground interactions while flying a sUAS with onboard measurement package to map the far field radiation pattern. Initial results producing radiation pattern maps are promising with work remaining to fully adapt fixed VHF measurements to the dynamic HF antenna test setup.

Decrossas, Emmanuel↗

Measurement of Residual Flexibility for Substructures Having Prominent Flexible Interfaces

Verification of a dynamic model of a constrained structure requires a modal survey test of the physical structure and subsequent modification of the model to obtain the best agreement possible with test data. Constrained-boundary or fixed-base testing has historically been the most common approach for verifying constrained mathematical models, since the boundary conditions of the test article are designed to match the actual constraints in service. However, there are difficulties involved with fixed-base testing, in some cases making the approach impractical. It is not possible to conduct a truly fixed-base test due to coupling between the test article and the fixture. In addition, it is often difficult to accurately simulate the actual boundary constraints, and the cost of designing and constructing the fixture may be prohibitive. For use when fixed-base testing proves impractical or undesirable, alternate free-boundary test methods have been investigated, including the residual flexibility technique. The residual flexibility approach has been treated analytically in considerable detail and has had limited frequency response measurements for the method. This concern is well-justified for a number of reasons. First, residual flexibilities are very small numbers, typically on the order of 1.0E-6 in/lb for translational diagonal terms, and orders of magnitude smaller for off-diagonal values. This poses difficulty in obtaining accurate and noise-free measurements, especially for points removed from the excitation source. A second difficulty encountered in residual measurements lies in obtaining a clean residual function in the process of subtracting synthesized modal data from a measured response function. Inaccuracies occur since modes are not subtracted exactly, but only to the accuracy of the curve fits for each mode; these errors are compounded with increasing distance from the excitation point. In this paper, the residual flexibility method is applied to a simple structure in both test and analysis. Measured and predicted residual functions are compared, and regions of poor data in the measured curves are described. It is found that for accurate residual measurements, frequency response functions having prominent stiffness lines in the acceleration/force format are needed. The lack of such stiffness lines increases measurement errors. Interface drive point frequency respose functions for shuttle orbiter payloads exhibit dominant stiffness lines, making the residual test approach a good candidate for payload modal tests when constrained tests are inappropriate. Difficulties in extracting a residual flexibility value from noisy test data are discussed. It is shown that use of a weighted second order least-squares curve fit of the measured residual function allows identification of residual flexibility that compares very well with predictions for the simple structure. This approach also provides an estimate of second order residual mass effects.

Tinker, Michael L.↗

A dual-frequency microwave technique for measuring rainwater content

This study shows that the dual-frequency (38, 25 GHz) differential attenuation (A(38-25)) coefficient can provide accurate estimates of rainwater content W potentially over a wide range of rainwater contents. While measurements along a microwave link are fairly easily implemented, radar estimates of A(38-25) can become clouded by differences between the radar reflectivity factors at the two frequencies (Z38, Z25). Root-mean-square deviations (epsilon) of the estimated W from the actual W are calculated for a wide variety of drop-size distributions and rainwater contents. The computed epsilon include the effects of standard measurement errors and differences between Z38 and Z25. Accurate estimates appear possible using a 38-25-GHz radar when W is not less than 1.5-2 g/cu m, depending upon the desired spatial resolution, and along a microwave link when W is not less than 0.5 g/cu m.

Jameson, A. R.↗

Sound-tube measurements of the relaxation frequency of moist nitrogen

At audible frequencies, the vibrational relaxation of nitrogen contributes significantly to the absorption of sound in still air. The accurate measurement of the humidity dependence of the relaxation frequency of nitrogen, as yet, has eluded careful measurement due to the difficulty in measuring small absorption at low frequencies. Recently, equipment has been constructed for measuring sound absorption in air as a function of humidity over the frequency range from 4 to 100 kHz. In the experiment described here, the temperature and humidity range of this equipment has been extended so that it can be used to study the relaxation absorption in nitrogen at temperatures from 311 K to 418 K. The results indicate that, over this temperature range, the frequency of maximum absorption in moist nitrogen, f, can be given by f/P = 260 x h, Hz/atm, where h is the percent mole fraction of water, and P is the pressure in atm. To the accuracy of the measurements reported here, f is independent of temperature over the range of temperatures at which the measurements were made.

Chang, D.↗

Minimization of Measurement Uncertainty in Optical Frequency Domain Reflectometry

Optical frequency domain reflectometry (OFDR) is a technique for interrogating optical fiber sensors to generate relative, quasi-distributed measurements. Although Optical frequency domain reflectometry (OFDR) is increasingly being adopted for aerospace, energy production, and structural monitoring applications, the quantification of uncertainty for OFDR measurements has not been developed beyond sparse empirical relationships. To address this knowledge gap, an uncertainty metric for OFDR measurements was developed. This uncertainty metric was applied to weight the edges between OFDR measurements on directed correlation graphs and analyzed to minimize the cumulative uncertainty. In conclusion, this work is the first to propose an uncertainty metric for OFDR and provides a generalized mathematical framework for optimizing OFDR hardware selection, optical fiber sensor selection, and postprocessing strategy.

42 ENGINEERING↗

Error Analysis of Wind Measurements for the University of Illinois Sodium Doppler Temperature System

Four-frequency lidar measurements of temperature and wind velocity require accurate frequency tuning to an absolute reference and long term frequency stability. We quantify frequency tuning errors for the Illinois sodium system, to measure absolute frequencies and a reference interferometer to measure relative frequencies. To determine laser tuning errors, we monitor the vapor cell and interferometer during lidar data acquisition and analyze the two signals for variations as functions of time. Both sodium cell and interferometer are the same as those used to frequency tune the laser. By quantifying the frequency variations of the laser during data acquisition, an error analysis of temperature and wind measurements can be calculated. These error bounds determine the confidence in the calculated temperatures and wind velocities.

Pfenninger, W. Matthew↗

The study of coronal plasma structures and fluctuations with Faraday rotation measurements

We report dual-frequency, polarimetric measurements of Faraday rotation of extragalactic radio sources viewed through the solar corona. The observations were made at the Very Large Array in 1990 during solar maximum. Of the nine observed, an excess rotation measure of -12.6 rad/sq m was detected for one source (0010+005), which was observed at an elongation of about 9 solar radii. This measurement is in fair agreement with an a priori model rotation measure of -8.6 rad/sq m estimated from coronal potential field models and the electron density model of Paetzold et al. (1992). Our measurement provides a value for the coronal magnetic field strength at 9 solar radii given a knowledge of the magnetic field sector structure, of 12.5 +/- 2.3 mG. Rotation measurements of 0010+005 were made approximately once per hour over an 11 hr period. During this interval, a slow change of about 1 rad/sq m/hr in rotation measure was detected. Although we are not absolutely certain that this drift is not unremoved ionospheric Faraday rotation, extensive analysis of data from the other sources suggests that this is not the case (Sakurai & Spangler 1994). The very long timescale for this variation argues against the agency of magnetohydrodynamics (MHD) waves, and we suggest occultation of 0010+005 by relatively static plasma structures in the corona. We filtered our rotation measure time series to search for variations on an hourly timescale, such as those reported by Hollweg et al. (1992), which could be attributed to coronal MHD waves. We were unable to detect such fluctuations and can report only an upper limit to the rms variation of 1.6 rad/sq m. This upper limit is of the same order, but slightly larger than the values typically reported by Hollweg et al. (1982). This upper limit to the rotation measure fluctuations limits the dimensionless wave amplitude (delta B)/B in the corona to be less than 0.7. Using the number, we estimate the MHD wave flux at the coronal base to be less than 1.6 x 10(exp 5) ergs/sq cm/s. This is less than the amount of wave energy flux required by wave-driven models of the solar wind. Finally, we discuss a number of ways in which such observations could be improved in the future.

Sakurai, Takayuki↗

Fast Extraction and Characterization of Fundamental Frequency Events from a Large PMU Dataset using Big Data Analytics

A novel method for fast extraction of fundamental frequency events (FFE) based on measurements of frequency and rate of change of frequency by Phasor Measurement Units (PMU) is introduced. The method is designed to work with exceptionally large historical PMU datasets. Statistical analysis was used to extract the features and train Random Forest and Catboost classifiers. The method is capable of fast extraction of FFE from a historical dataset containing measurements from hundreds of PMUs captured over multiple years. The reported accuracy of the best algorithm for classification expressed as Area Under the receiver operating Characteristic curve reaches 0.98, which was obtained in out-of-sample evaluations on 109 system-wide events over 2 years observed at 43 PMUs. Then Minimum Volume Enclosing Ellipsoid Algorithm was used to further analyze the events. 93.72% events were correctly characterized, where average duration of the event as seen by the PMU was 9.93 sec.

Baembitov, Rashid↗

High Frequency PIN-Diode Switches for Radiometer Applications

Internally calibrated radiometers are needed for ocean topography and other missions. Typically internal calibration is achieved with Dicke switching as one of the techniques. We have developed high frequency single-pole double-throw (SPDT) switches in the form of monolithic microwave integrated circuits (MMIC) that can be easily integrated into Dicke switched radiometers that utilize microstrip technology. In particular, the switches we developed can be used for a radiometer such as the one proposed for the Surface Water and Ocean Topography (SWOT) Satellite Mission whose three channels at 92, 130, and 166 GHz would allow for wet-tropospheric path delay correction near coastal zones and over land. This feat is not possible with the current Jason-class radiometers due to their lower frequency signal measurement and thus lower resolution. The MMIC chips were fabricated at NGST using their InP PIN diode process and measured at JPL using high frequency test equipment. Measurement and simulation results will be presented.

PIN-diode↗

Spatial and Spatial Frequency Spreads of Masking: Measurements and A Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2, 4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 z 0 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, Joshua A.↗

Spatial and Spatial Frequency Spreads Of Masking: Measurements and a Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2,4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, J. A.↗

The delta Doppler technique for LDV measurements at long distances

A technique for measuring velocity, referred to as a Delta Doppler technique, was presented. This technique determines scattering source velocities by measuring the difference in Doppler shifts of two different frequencies. By transmitting the two frequencies along the same path, a moving fringe pattern is established such that a nonmoving scatterer at the sensing volume would see an intensity variation exactly equal to the difference in the transmitted frequencies. If the particle has a velocity component along an axis which bisects the angle formed by the transmitter and receiver axes, a Doppler shift in the difference frequency can be measured and the velocity component computed. The frequency measured would correspond to the difference in Doppler frequencies that two laser Doppler velocimeters using separate frequencies (the same frequencies as used previously) would have measured, thus the term Delta Doppler.

Cliff, W. C.↗

Swept frequency technique for dispersion measurement of microstrip lines

Microstrip lines used in microwave integrated circuits are dispersive. Because a microstrip line is an open structure, the dispersion can not be derived with pure TEM, TE, or TM mode analysis. Dispersion analysis has commonly been done using a spectral domain approach, and dispersion measurement has been made with high Q microstrip ring resonators. Since the dispersion of a microstrip line is fully characterized by the frequency dependent phase velocity of the line, dispersion measurement of microstrip lines requires the measurement of the line wavelength as a function of frequency. In this paper, a swept frequency technique for dispersion measurement is described. The measurement was made using an automatic network analyzer with the microstrip line terminated in a short circuit. Experimental data for two microstrip lines on 10 and 30 mil Cuflon substrates were recorded over a frequency range of 2 to 20 GHz. Agreement with theoretical results computed by the spectral domain approach is good. Possible sources of error for the discrepancy are discussed.

Lee, R. Q.↗

Bayesian tomography of high-dimensional on-chip biphoton frequency combs with randomized measurements

Abstract Owing in large part to the advent of integrated biphoton frequency combs, recent years have witnessed increased attention to quantum information processing in the frequency domain for its inherent high dimensionality and entanglement compatible with fiber-optic networks. Quantum state tomography of such states, however, has required complex and precise engineering of active frequency mixing operations, which are difficult to scale. To address these limitations, we propose a solution that employs a pulse shaper and electro-optic phase modulator to perform random operations instead of mixing in a prescribed manner. We successfully verify the entanglement and reconstruct the full density matrix of biphoton frequency combs generated from an on-chip Si 3 N 4 microring resonator in up to an 8 × 8-dimensional two-qudit Hilbert space, the highest dimension to date for frequency bins. More generally, our employed Bayesian statistical model can be tailored to a variety of quantum systems with restricted measurement capabilities, forming an opportunistic tomographic framework that utilizes all available data in an optimal way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗