Stationary-Frame Grid-Forming Inverter Control Architectures for Unbalanced Fault-Current Limiting
Not provided.
Granular Flow in Novel Octet Shape–Based Lattice Frame Material
Moving packed-bed heat exchangers in concentrated solar power (CSP) plants involves heat transfer between heated falling particles and supercritical carbon dioxide. The overall effective thermal conductivity of the moving packed bed and particle-side channel contact resistances are still the bottlenecks in achieving the desirable thermal transport levels. To this end, a novel moving packed bed heat exchanger consisting of an Octet lattice packed between the walls of the particle-side channel is proposed in this study. Granular flow analysis in Octet lattice moving packed bed heat exchanger (OLHX) was conducted through experiments and discrete element method (DEM)-based numerical simulations. The experimental images clearly demonstrated stagnation regions upstream of lattice fibers, void regions downstream of the fiber junctions, and wavy-type unobstructed flow on the lateral sides of the fibers. DEM simulations were successful in capturing all these critical flow phenomena. Larger flow velocities were observed on the lateral sides of the fibers in the simulations. Also, when the particles in the silo were emptied, the final images showed an accumulation of particles on the inter-fiber as well as fiber–channel wall junctions. Moreover, the fiber connections resulted in some regions devoid of particle contact on the channel endwall, which means that these regions would suffer from poor thermal exchange. Finally, the overall mass flowrate increased with increasing porosity for a fixed particle diameter.
Enhanced phagocytosis and complement-mediated killing of Mannheimia haemolytica serotype 1 following in-frame CMP-sialic acid synthetase ( neuA ) gene deletion
ABSTRACT Mannheimia haemolyticais the most significant bacterial pathogen associated with the bovine respiratory disease complex. Although sialic acid is a known virulence factor in other members of Pasteurellaceae, such asHistophilus somniandPasteurella multocida, the significance of sialic acid to the virulence ofM. haemolyticais currently unknown. Therefore, the role of sialic acid as a virulence determinant ofM. haemolyticawas investigated by constructing an in-frameneuA[CMP-N-acetylneuraminic acid (Neu5Ac/sialic) synthetase] mutant, which was shown by high-performance anion exchange chromatographic analysis (HPAEC) to be devoid of sialic acid on the lipopolysaccharide (LPS). Both theneuAmutant and wild-type parent strains exhibited similar growth rates in the growth curve assay. Real-time qPCR and ELISA evaluation showed no differences in proinflammatory cytokine expressions (IL-1β, IL-6, and IL-8) between theneuAmutant and parent strain when peripheral blood mononuclear cells were incubated with LPS. Interestingly, theneuAmutant was three to four logs more sensitive to a whole-blood bacterial killing assay than the parent strain. Similar results were also observed in plasma and serum bacterial killing assays. Flow cytometry analyses showed higher uptake ofneuAmutant by phagocytes, compared to the parent strain, in the whole-blood phagocytosis assay; however, no difference in reactive oxygen species production in neutrophils or monocytes was detected for either strain. Taken together, these results indicate that sialylation ofM. haemolyticaLPS plays a vital role in reducing complement-mediated and phagocytic killing. IMPORTANCE The Gram-negative coccobacillusMannheimia haemolyticais a natural inhabitant of the upper respiratory tract in ruminants and the most common bacterial agent involved in bovine respiratory disease complex development. Key virulence factors harbored byM. haemolyticaare leukotoxin, lipopolysaccharide, capsule, adhesins, and neuraminidase which are involved in evading innate and adaptive immune responses. In this study, we have shown that CMP-sialic acid synthetase (neuA) is necessary for the incorporation of sialic acid onto the membrane, and inactivation ofneuAresults in increased phagocytosis and complement-mediated killing ofM. haemolytica,thus demonstrating that sialylation contributes to the virulence ofM. haemolytica.
Single-frame far-field diffractive imaging with randomized illumination
Contains a transmission ptychography dataset collected from a chrome on glass Siemens star under optical illumination. The probe is generated by a randomized zone plate under illumination from a spatially filtered green laser. A single diffraction pattern was removed from the dataset and reported in a separate cxi file. In addition, a single exposure collected after manually defocusing the probe is reported. The ptychography dataset is used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.
Single-frame far-field diffractive imaging with randomized illumination
Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.
Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics
Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.
Test Shipment of the PIP-II 650 MHz Transport Frame Between FNAL to STFC-UKRI
The PIP-II Project will receive fully assembled cryomodules from CEA and STFC-UKRI as in-kind contributions. Damage to these cryomodules during transport is understood to be a significant risk to the project, so an extensive testing and validation program is in process to mitigate this risk. The centerpiece of this effort is the eventual shipment from FNAL to STFC-UKRI and back of a prototype HB650 cryomodule with cold testing before and after shipment to verify no functionality changes from shipment. Most recently, a test shipment to the UK and back using a cryomodule analog was completed using realistic logistics, handling, instrumentation, and planning. The process of executing this test shipment, lessons learned, and plan moving forward will be presented here.
Effects of Frame Constraints on Internal Module Damage During Mechanical Load Testing.
Abstract not provided.
A Systems-Theoretic Framing for an Integrated Nuclear Safety, Safeguards, & Security (3S) Approach.
Abstract not provided.
DARHT CALCULATIONS AND UPDATED PLC FRAME DESIGN
Explore the source record for details and available documents.
Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers
Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.
An Enhanced Snow-Shedding Model: the Module Frame as a Key Variable
Explore the source record for details and available documents.
Natural Excitation Within a Test Frame
Explore the source record for details and available documents.
Natural Excitation Within a Test Frame
Explore the source record for details and available documents.
Validation of High-Flux Plate-and-Frame Membrane module design for CO2 capture: a CFD Approach
Validation of a CFD model for Membrane-based carbon capture. We compare our high-fidelity 3D CFD Model to a conventional cross-flow 1D model. We show that for high-performing membranes, the 1D model is very limited and struggles to represent the separation system.
Mixed-mode Interfacial Fracture Testing using Dual Actuator Test Frame
Explore the source record for details and available documents.