At least 559 records · Page 31

Highly-scalable GPU-accelerated compressible reacting flow solver for modeling high-speed flows

Emerging supercomputing systems utilize a combination of central processing units (CPUs) and graphics processing units (GPUs) in an effort to reach exascale capabilities while minimizing the energy footprint of operating such systems. Such heterogeneous machines introduce new challenges for fluids solvers because the hardware architecture and operation of a GPU are fundamentally different from conventional CPUs. In this work, a general approach for efficient implementation of finite-volume based reacting flow solvers on such heterogeneous systems is presented. Three main challenges, namely, data access pattern, thread divergence, and thread safety, are addressed. Since compressible reacting flows require special methods to deal with chemical reactions, hyperbolic and nonlinear convection terms, and the presence of turbulence, specific algorithms that ensure GPU-based efficiency are developed. The approach is demonstrated on the widely available OpenFOAM open source software by modifying core algorithms for GPU accessibility. The scalability of the resulting solver, is demonstrated using practical test cases, including flow through a scramjet engine and the dynamics of a rotating detonation engine. Here, the solver provides near-ideal scaleup on a large number of GPUs (>3000), and extremely efficient use of the GPUs, with throughput nearly a constant even when processing a large number of control volumes.

42 ENGINEERING↗

Effect of flow topology on the calculation of two-phase frictional multipliers in uniformly heated flow of R-134a in a rectangular duct

The two-phase frictional multipliers for SUVA R-134a flowing in a rectangular duct (with D{sub H} = 4.8 mm) have been measured for three nominal system pressures (0.88, 1.34 and 2.34 MPa) and four nominal mass fluxes (510, 1020 and 1740, 2040 kg/m{sup 2}/s) under uniform heat flux conditions. The data is compared with adiabatic data previously taken at similar flow conditions, as well as with several classical multiplier correlations. The comparisons reveal a strong effect of pressure and mass flux on the flow topology and, by extension, a large effect on the calculation of acceleration and frictional pressure drop components. For this fluid and this geometry, entrainment and fluid separation is enhanced at higher pressures and mass flux such that most of the liquid exists in the test section edges and as dispersed droplets in the core. For these cases, the classical simplified approach to calculate acceleration pressure drop fails to adequately predict the acceleration component and leads to erroneous calculations of frictional pressure drop from the measured total pressure drop. Best estimates of the true acceleration component are given, based on void profiles measured with a gamma densitometer system, comparisons to the adiabatic data, and recasting the data in terms of the total pressure drop multiplier as a function of the Martinelli parameter, X{sub tt}. (author)

42 ENGINEERING↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Comparative analysis for various redox flow batteries chemistries using a cost performance model

A robust performance-based cost model is developed for all-vanadium, iron-vanadium and iron chromium redox flow batteries. Systems aspects such as shunt current losses, pumping losses and thermal management are accounted for. The objective function, set to minimize system cost, allows determination of stack design and operating parameters such as current density, flow rate and depth of discharge (DOD). Component costs obtained from vendors are used to calculate system costs for various time frames. A 2 kW stack data was used to estimate unit energy costs and compared with model estimates for the same size electrodes. The tool has been shared with the redox flow battery community to both validate their stack data and guide future direction.

electrolyte↗

“Wine-Dark Sea” in an Organic Flow Battery: Storing Negative Charge in 2,1,3-Benzothiadiazole Radicals Leads to Improved Cyclability

Redox-active organic materials (ROMs) have shown great promise for redox flow battery applications but generally encounter limited cycling efficiency and stability at relevant redox material concentrations in nonaqueous systems. Here we report a new heterocyclic organic anolyte molecule, 2,1,3-benzothiadiazole, that has high solubility, a low redox potential, and fast electrochemical kinetics. Coupling it with a benchmark catholyte ROM, the nonaqueous organic flow battery demonstrated significant improvement in cyclable redox material concentrations and cell efficiencies compared to the state-of-the-art nonaqueous systems. Especially, this system produced exceeding cyclability with relatively stable efficiencies and capacities at high ROM concentrations (>0.5 M), which is ascribed to the highly delocalized charge densities in the radical anions of 2,1,3-benzothiadiazole, leading to good chemical stability. As a result, this material development represents significant progress toward promising next-generation energy storage.

25 ENERGY STORAGE↗

A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration

A novel fiber optic macro-bend based gas flowmeter for low flow rates is presented. Theoretical analysis of the sensor working principle, design, and static calibration were performed. The measuring system consists of: an optical fiber, a light emitting diode (LED), a Quadrant position sensitive Detector (QD), and an analog electronic circuit for signal processing. The fiber tip undergoes a deflection in the flow, acting like a cantilever. The consequent displacement of light spot center is monitored by the QD generating four unbalanced photocurrents which are function of fiber tip position. The analog electronic circuit processes the photocurrents providing voltage signal proportional to light spot position. A circular target was placed on the fiber in order to increase the sensing surface. Sensor, tested in the measurement range up to 10 l min{sup -1}, shows a discrimination threshold of 2 l min{sup -1}, extremely low fluid dynamic resistance (0.17 Pa min l{sup -1}), and high sensitivity, also at low flow rates (i.e., 33 mV min l{sup -1} up to 4 l min{sup -1} and 98 mV min l{sup -1} from 4 l min{sup -1} up to 10 l min{sup -1}). Experimental results agree with the theoretical predictions. The high sensitivity, along with the reduced dimension and negligible pressure drop, makes the proposed transducer suitable for medical applications in neonatal ventilation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractal dimension of cohesive sediment flocs at steady state under seven shear flow conditions

The morphological properties of kaolin flocs were investigated in a Couette-flow experiment at the steady state under seven shear flow conditions (shear rates of 5.36, 9.17, 14, 24, 31, 41 and 53 s -1 ). These properties include a one-dimensional (1-D) fractal dimension (D 1 ), a two-dimensional (2-D) fractal dimension (D 2 ), a perimeter-based fractal dimension (D pf ) and an aspect ratio (AR). They were calculated based on the projected area (A), equivalent size, perimeter (P) and length (L) of the major axis of the floc determined through sample observation and an image analysis system. The parameter D 2 , which characterizes the relationship between the projected area and the length of the major axis using a power function, A ∝ L D 2 , increased from 1.73 ± 0.03, 1.72 ± 0.03, and 1.75 ± 0.04 in the low shear rate group (G = 5.36, 9.17, and 14 s -1 ) to 1.92 ± 0.03, 1.82 ± 0.02, 1.85 ± 0.02, and 1.81 ± 0.02 in the high shear rate group (24, 31, 41 and 53 s -1 ), respectively. The parameter D 1 characterizes the relationship between the perimeter and length of the major axis by the function P ∝ L D 1 and decreased from 1.52 ± 0.02, 1.48 ± 0.02, 1.55 ± 0.02, and 1.63 ± 0.02 in the low shear group (5.36, 9.17, 14 and 24 s -1 ) to 1.45 ± 0.02, 1.39 ± 0.02, and 1.39 ± 0.02 in the high shear group (31, 41 and 53 s -1 ), respectively. The results indicate that with increasing shear rates, the flocs become less elongated and that their boundary lines become tighter and more regular, caused by more breakages and possible restructurings of the flocs. The parameter D pf , which is related to the perimeter and the projected area through the function , decreased as the shear rate increased almost linearly. The parameter AR, which is the ratio of the length of the major axis and equivalent diameter, decreased from 1.56, 1.59, 1.53 and 1.51 in the low shear rate group to 1.43, 1.47 and 1.48 in the high shear rate group. These changes in D pf and AR show that the flocs become less convoluted and more symmetrical and that their boundaries become smoother and more regular in the high shear rate group than in the low shear rate group due to breakage and possible restructuring processes. To assess the effects of electrolyte and sediment concentration, 0.1 mol/L calcium chloride (CaCl 2 ) and initial sediment concentration from 7.87 × 10 -5 to 1.57 × 10 -5 were used in this preliminary study. The addition of electrolyte and increasing sediment concentration could produce more symmetrical flocs with less convoluted and simpler boundaries. In addition, some new information on the temporal variation of the median size of the flocs during the flocculation process is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Bypass Fluid Flow in an Active Magnetic Regenerative Liqueer

Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass unbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. While researchers have been aware of this phenomenon for decades, experimental performance improvements from bypass fluid flow have yet to be reported in open literature. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a function of the bypass ow fraction. Experiments are performed at a fixed temperature span that yield a 25% improvement in net cooling power, affirming the potential of bypass cooling power.

active magnetic regenerator, hydrogen, liquefacati↗

Electrochemical Conversion of CO 2 to Methyl Formate in a Flow Electrolyzer with Mixed Propylene Carbonate/Methanol Catholyte

Despite the promise of electrochemical carbon dioxide reduction as a technology for the production of clean fuels and decarbonization of the chemical industry, research has mostly focused on aqueous systems with a relatively limited set of products that have been achieved via electrosynthesis. Increasingly, CO 2 electroreduction in nonaqueous solvents is being pursued to develop new avenues for expanding the suite of products that can be made with high selectivity. CO 2 reduction in alcohols coupled with in situ esterification to produce esters is one such route that utilizes nonaqueous electrolyte. To be practical, such electrochemical syntheses need to be translated to a high-performance reactor such as a flow electrolyzer. However, many organic solvents, such as alcohols, wet and flood porous electrodes, thus impeding reactor performance. In this work, methanol was mixed with propylene carbonate as a catholyte for a gas-fed CO 2 flow electrolyzer that avoided cathode flooding. Simultaneously, a dual aqueous anolyte was used for water oxidation as a scalable and sustainable anodic half-reaction. The performance effect of methanol concentration, catholyte acidity, CO 2 flow rate, and dilute water in the catholyte were investigated. With 10 vol % methanol in 90 vol % propylene carbonate, 63% faradaic efficiency for methyl formate ester product was sustained without cathode flooding. However, improvements are still needed to lower the cell resistance and further increase the operating current density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow topologies and turbulence scales in a jet-in-cross-flow

This study presents a detailed analysis of the flow topologies and turbulence scales in the jet-in-cross-flow experiment of [Su and Mungal JFM 2004]. The analysis is performed using the Large Eddy Simulation (LES) technique with a highly resolved grid and time-step and well controlled boundary conditions. This enables quantitative agreement with the first and second moments of turbulence statistics measured in the experiment. LES is used to perform the analysis since experimental measurements of time-resolved 3D fields are still in their infancy and because sampling periods are generally limited with direct numerical simulation. A major focal point is the comprehensive characterization of the turbulence scales and their evolution. Time-resolved probes are used with long sampling periods to obtain maps of the integral scales, Taylor microscales, and turbulent kinetic energy spectra. Scalar-fluctuation scales are also quantified. In the near-field, coherent structures are clearly identified, both in physical and spectral space. Along the jet centerline, turbulence scales grow according to a classical one-third power law. However, the derived maps of turbulence scales reveal strong inhomogeneities in the flow. From the modeling perspective, these insights are useful to design optimized grids and improve numerical predictions in similar configurations.

47 OTHER INSTRUMENTATION↗

Counter-Current Flow Limitation Studies in Complex Geometries Utilizing Interface Capturing Simulations Coupled with PID Flow Rate Controller

In nuclear thermal-hydraulic studies, counter-current flow limitation (CCFL) typically refers to steam rising at a fast rate such that it prevents coolant from draining down within a confined channel. CCFL is a crucial issue in nuclear reactor safety analysis. This study investigates CCFL in debris bed channels using high-resolution interface-capturing simulations. A novel proportional-integral-derivative flow rate controller is developed to efficiently achieve the CCFL conditions. Verification studies confirm that CCFL occurs under the same conditions with or without the controller, demonstrating that PID control ensures accurate prediction. Three debris bed channel geometries were examined: a cylindrical channel, a channel with small obstacles, and a channel with large obstacles. Results show that obstacles significantly impact flow behavior, interfacial shear, wall shear, and pressure gradients required for CCFL. Furthermore, the comparison with experimental data confirmed that simulations incorporating geometric complexities align more closely with experimental CCFL conditions. A pressure gradient correlation was also developed for CCFL prediction.

Counter-current flow limitation↗

Collaborative investigation of the internal flow and near-nozzle flow of an eight-hole gasoline injector (Engine Combustion Network Spray G)

The internal details of fuel injectors have a profound impact on the emissions from gasoline direct injection engines. However, the impact of injector design features is not currently understood, due to the difficulty in observing and modeling internal injector flows. Gasoline direct injection flows involve moving geometry, flash boiling, and high levels of turbulent two-phase mixing. In order to better simulate these injectors, five different modeling approaches have been employed to study the engine combustion network Spray G injector. Here these simulation results have been compared to experimental measurements obtained, among other techniques, with X-ray diagnostics, allowing the predictions to be evaluated and critiqued. The ability of the models to predict mass flow rate through the injector is confirmed, but other features of the predictions vary in their accuracy. The prediction of plume width and fuel mass distribution varies widely, with volume-of-fluid tending to overly concentrate the fuel. All the simulations, however, seem to struggle with predicting fuel dispersion and by inference, jet velocity. This shortcoming of the predictions suggests a need to improve Eulerian modeling of dense fuel jets.

ECN↗