Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Comprehensive framework for data-driven model form discovery of the closure laws in thermal-hydraulics codes

The two-phase two-fluid model is a basis of many thermal-hydraulics codes used in design, licensing, and safety considerations of nuclear power plants. Thermal-hydraulics codes rely on the closure laws to close the system of conservation equations and describe the interactions between phases. These laws, derived from years of experimental investigations, are semi-empirical correlations that lack generality and have a limited range of applicability. Increase of computational power, availability of new experiments, and development of high-fidelity simulations has increased the number of validation data. The discrepancies between the code predictions and the validation data are a great source of knowledge. Missing physics that are not included in the model but are important for the considered phenomena can be discovered by propagating the information from the experimental results through the model. Furthermore, physics-discovered data-driven model form (P3DM) methodology integrates available integral effect tests and separate effects tests to determine the necessary corrections to the model form of the closure laws. In contrast to existing calibration techniques, the methodology modifies the functional form of the closure laws. Based on the functional form of the correction, the missing physics that were not included in the original model can be discovered. The methodology provides the alternative to the machine learning approach, in which the model is discovered in the form of the intractable black-box relation. In this work, the methodology was applied to the CTF subchannel code to improve the prediction of the two-phase flow phenomena.

42 ENGINEERING↗

AGR-5/6/7 Final Release-to-Birth Ratio Data Analysis

AGR-5/6/7 is the last of a series of Advanced Gas Reactor (AGR) experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tristructural isotropic (TRISO) low-enriched fuel for use in the high-temperature gas cooled reactor (HTGR). AGR configuration and irradiation conditions are based on prismatic HTGR technology that is distinguished primarily through the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO-coated particle fuel. The AGR tests provide valuable irradiation-performance data to support fuel process development, qualify fuel for normal operation and accident conditions, and support development and validation of fuel performance and fission-product (FP) transport models and codes. Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. Release-to-birth ratios (R/B) for fission-gas isotopes released from each capsule are calculated from release rates, measured by germanium detectors in the Fission Product Monitoring System (FPMS) installed downstream from each capsule, and birth rates calculated using numerical models of FG generation. The R/Bs are a critical measure of the ability of the fuel kernel, the particle coating layers, and the compact matrix to retain fission-gas atoms, preventing their release into the sweep-gas flow, and the impact of initially defective particles and/or particle-coating failures that occur during irradiation. For fission-gas isotopes, particle failure is defined as failure of all coating layers, allowing gaseous fission atoms to escape from a particle. During the first five cycles (162B ? 165A), R/Bs were stable in the 10-8?10-6 range, and no in-pile particle failures were observed, based on the gross gamma counts. The maximum R/B value of around 2 ? 10-6 for Kr-85m resulted from the presence of as-fabricated exposed kernels (based on the high exposed kernel fraction), the dispersed uranium, and high fuel particle temperatures in Capsule 1. Comparison of capsule-measured R/Bs from these early cycles to predictions using the previously developed AGR R/B model demonstrated FG release from the AGR-5/6/7 TRISO fuel was comparable to that of previous experiments. In addition, the Kr-85m R/B per-exposed-kernel values are comparable to R/B values obtained in AGR-3/4 irradiation experiment and four irradiation experiments performed during 1980s: (1) HRB-17/18, (2) COMEDIE-BD1, (3) HFR B1, and (4) HRB-21. In contrast, all measured R/B values are lower than predictions by the commonly used Richards and German models, which are intentionally conservative. A large number of in-pile particle failures occurred in Capsule 1 by the end of Cycle 166A. During the final four cycles (166A ? 168A), apparent damage to the Capsule 1 gas line appeared to cause FG leakage from that capsule into the other four capsules, resulting in an increase in fission gas (FG) detected in the effluent for all capsules. Isolation of the Capsule 1 gas line during the last three cycles also prevented measurement of its FG release. Thus, R/Bs in all capsules after Cycle 166A are highly uncertain because of undefined amount of leakage from Capsule 1, especially for long-lived isotopes. A few hundred in-pile particle failures were estimated for Capsule 1 before the end of Cycle 166A, but the total number of failures is unknown due to the lack of FG release data in the later cycles. Based primarily on evidence from the gross gamma counts during Cycle 168A, approximately 15 particles failed in Capsule 3 and four particles failed in Capsule 2. In-pile failures in Capsule 3 were anticipated because this capsule was designed to operate beyond the HTGR normal operating temperature range. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR model, developed in INL/EXT-14-32970, for R/B of the short-lived isotopes (Kr-89 and Xe-137) with minimal leakage from Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed optimization and control for autonomous distributed energy resource power dispatch and frequency regulation considering communication failures

Distributed energy resources (DERs) can significantly enhance grid flexibility by supplying power and secondary frequency regulation (SFR) services. Yet, their large number and dispersed nature limit the effectiveness of traditional centralized power dispatch and frequency control schemes, and expose the system to single-point communication failures. This paper presents a unified distributed optimization and control framework for DER power dispatch and SFR provision. A transmission-loss-aware distributed direct current optimal power flow is first formulated to optimize DER power dispatch and reserve scheduling. On top of this, a fully distributed control scheme for DER autonomous SFR provision is developed to allocate automatic generation control signals cost-effectively while ensuring robustness to communication link disruptions. The framework is validated on IEEE 14-bus and 39-bus transmission systems with large-scale distribution feeders using transmission-distribution dynamic co-simulation, demonstrating reliable and autonomous DER power dispatch and SFR provision under diverse operating conditions and communication contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The evolution dynamical processes of Ural blocking through the lens of local finite-amplitude wave activity budget analysis

Understanding the formation and evolution mechanisms of Ural blocking (UB) is of great importance for the prediction of UB and relevant extremes in east Asia. Using the 6-hourly ERA-Interim reanalysis data, this study quantifies the conservative and nonconservative processes in the lifecycle of UB through the lens of the hybrid Eulerian-Lagrangian local finite-amplitude wave activity (LWA) diagnostics. It is found that (i) as a wave activity source, eddy heat flux works to not only initiate the UB, but also prevent the wave activity of the blocking from dispersing downstream---the key characteristic of blocking; (ii) both the wave propagation and wave advection mechanisms are indispensable for the evolution of UB, playing a tug-of-war on the downstream development of wave activity; (iii) Throughout the lifespan of UB, diabatic heating provides the most important damping mechanism for the wave activity both upstream and downstream; and (IV) irreversible PV mixing appears to compensate the eddy PV flux during the wave breaking stage of blocking.

Blocking, wave activity, eddy-mean flow interactio↗

Numerical Simulations of High Prandtl Number Liquid Jets Impinging on a Flat Plate

In this work, 3D simulations of oil jets impinging on a flat, heated wall are presented. The numerical setup uses the Volume of Fluid (VoF) method to model the two-phase flow. A careful grid definition across the liquid film, along with the use of the Conjugate Heat Transfer (CHT) approach allowed local heat transfer to be solved with fine resolution at the wall. Variations of liquid flow rate, liquid temperature and surface temperature allow to cover a wide range of local Reynolds and Prandtl numbers (226 < Re < 2850, 77 < Pr < 161). Resulting surface-averaged heat transfer compares very well with experimental measurements conducted in a previous study. In-depth analysis of the flow has identified expected features from the literature. In particular, the impact of jet axial velocity profiles on the heat transfer distribution in the stagnation zone was clearly stated. The increase in heat transfer when warming the liquid film was also reproduced and explained by a decrease in oil viscosity and an increase in film velocity. All those effects were taken into account in correlations for stagnation and local values of Nusselt number. A grid sensitivity study was also conducted, showing that if the grid solving the thermal boundary layer in the stagnation zone can be coarsened without impacting local and surface-averaged predictions of heat transfer, a minimum resolution (2 to 3 cells) within the thermal boundary layer is however required for an accurate prediction of heat transfer.

conjugate heat transfer↗

Colloid-facilitated transport of 238 Pu, 233 U and 137 Cs through fractured chalk: Laboratory experiments, modelling, and implications for nuclear waste disposal

The influence of montmorillonite colloids on the mobility of 238 Pu, 233 U and 137 Cs through a chalk fracture was investigated to assess the transport potential for radioactive waste. Radioisotopes of each element, along with the conservative tracer tritium, were injected in the presence and absence of montmorillonite colloids into a naturally fractured chalk core. In parallel, batch experiments were conducted to obtain experimental sorption coefficients (K d , mL/g) for both montmorillonite colloids and the chalk fracture material. Breakthrough curves were modelled to determine diffusivity and sorption of each radionuclide to the chalk and the colloids under advective conditions. Uranium sorbed sparingly to chalk (log K d = 0.7 ± 0.2) in batch sorption experiments. 233 U(VI) breakthrough was controlled primarily by the matrix diffusion and sorption to chalk (15 and 25% recovery with and without colloids, respectively). Cesium, in contrast, sorbed strongly to both the montmorillonite colloids and chalk (batch log K d = 3.2 ± 0.01 and 3.9 ± 0.01, respectively). The high affinity to chalk and low colloid concentrations overwhelmed any colloidal Cs transport, resulting in very low 137 Cs breakthrough (1.1–5.5% mass recovery). Batch and fracture transport results, and the associated modelling revealed that Pu migrates both as Pu (IV) sorbed to montmorillonite colloids and as dissolved Pu(V) (7% recovery). Transport experiments revealed differences in Pu(IV) and Pu(V) transport behavior that could not be quantified in simple batch experiments but are critical to effectively predict transport behavior of redox-sensitive radionuclides. Finally, a brackish groundwater solution was injected after completion of the fracture flow experiments and resulted in remobilization and recovery of 2.2% of the total sorbed radionuclides which remained in the core from previous experiments. In general, our study demonstrates consistency in sorption behavior between batch and advective fracture transport. Finally, the results suggest that colloid-facilitated radionuclide transport will enhance radionuclide migration in fractured chalk for those radionuclides with exceedingly high affinity for colloids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Small Warm Tributary Provides Prespawning Resources for Colorado Pikeminnow in a Cold Dam-Regulated River

Abstract Riverine habitat mosaics, including tributaries, are an important reason the Green River subbasin supports the largest remaining population of federally endangered Colorado Pikeminnow Ptychocheilus lucius in the Colorado River Basin. Upstream Colorado Pikeminnow distribution is limited by Flaming Gorge Dam and few typically occurred in the reach immediately downstream of the dam, which is the reach most affected by thermal and hydrologic alterations. However, fish captures and passive integrated transponder (PIT) antenna sampling of previously tagged individuals from 2011 to 2021 revealed seasonal congregations of up to 75 Colorado Pikeminnow annually in the mouth of Vermillion Creek, a small tributary in the regulated reach. Approximately 11% (N = 93 individuals) of the entire 2017–2018 Green River basin population were encountered in Vermillion Creek over the 11-y study, an underestimate of use considering that untagged fish were not detected by antennas. Colorado Pikeminnow used Vermillion Creek primarily when Green River spring flows from Flaming Gorge Dam were high and cold in May through mid-June when the confluence was a large, deep backwater warmer than the main channel and supported forage fishes. Intra-annual encounters revealed seasonal residence times for individual Colorado Pikeminnow up to 91 d, and multiple inter-annual encounters indicated site fidelity. Frequent detections of individual Colorado Pikeminnow in a Yampa River spawning area soon after their detections in Vermillion Creek indicate this tributary may be an important resource for reproductive adults. The intensive and basin-wide PIT tagging and detection program for Colorado Pikeminnow enhanced our understanding of the importance of small habitat nodes such as Vermillion Creek in the Green River drainage network. Understanding and protecting these seasonally available riverine habitat mosaics used for prespawning conditioning may assist with recovery of Colorado Pikeminnow.

Biodiversity & Conservation↗

Valuation of Novel Waste Heat Sources and a Path Towards Adoption: Preprint

It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.

district energy↗

Autonomous online optimization of a closed-circuit reverse osmosis system

As freshwater becomes increasingly scarce, many industrial and municipal water utilities look at premise-scale water treatment and reuse to meet water demand. Closed-circuit reverse osmosis (CCRO) has been proposed as a promising process design to do so. This sequencing batch process enables operation at higher brine salinity levels by means of a recycle flow. Optimal operation requires that the maximum salinity level at the membrane surface represents an optimal trade-off between brine disposal costs and energy efficiency. This maximum salinity level may change over time as the feed water composition changes and electricity markets fluctuate. In this article, we present the results of the experimental evaluation of an automatic technique for continuous online optimization, known as extremum seeking control. This technique has a long history in the process control community but has received little traction so far in the water industry. We modify this technique to enable its use for online optimization of CCRO, specifically to account for its sequential batch operation. We challenge the optimization schemes through several experimental tests and illustrate the advantages and drawbacks of extremum-seeking control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CONVERSION OF COAL WASTES AND MUNICIPAL SOLIDS MIXTURES BY PYROLYSIS TORREFACTION AND ENTRAINED FLOW GASIFICATION

Hundreds of millions of tons of underutilized high-ash, low-energy-density bituminous and anthracite waste coal can be found in the U.S. These stockpiles contribute to water pollution from leaching that is harmful to waterways downstream of the piles. Conventional circulating fluidized combustion power plants use this coal to generate energy but emit toxic trace metals into groundwater (e.g., lead, mercury, arsenic). In addition, refuse-derived fuel (RDF) including municipal solid waste (MSW), biomass, waste plastics, and industrial waste are an enormous and untapped resource that is currently filling landfills or incinerated for low-quality energy with poor emissions. Mainstream Engineering has developed a combined pyrolysis torrefaction entrained flow gasification (PT-EFG) process that utilizes combined waste coal and RDF to create an alternative energy source, increasing energy independence and security and reducing the environmental burden from coal mines and processing facilities. Mainstream’s self-sustaining PT process converts RDF into feedstocks that can be pulverized and handled like conventional coal, enabling combined RDF-waste coal co-feeding into an EFG. The EFG operates at temperatures high enough to slag the ash completely, destroying any residual polycyclic aromatic hydrocarbons (PAHs), converting ash into nonporous vitrified slag or non-leachable ash, and generating high-hydrogen syngas for power generation or liquid fuels. During Phase II, Mainstream successfully demonstrated PT of biomass and MSW into a coal-like feedstock, which was co-gasified with waste coal in an EFG in a combined PT EFG process

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Genotype–environment associations across spatial scales reveal the importance of putative adaptive genetic variation in divergence

Abstract Identifying areas of high evolutionary potential is a judicious strategy for developing conservation priorities in the face of environmental change. For wide‐ranging species occupying heterogeneous environments, the evolutionary forces that shape distinct populations can vary spatially. Here, we investigate patterns of genomic variation and genotype–environment associations in the hermit thrush ( Catharus guttatus ), a North American songbird, at broad (across the breeding range) and narrow spatial scales (at a hybrid zone). We begin by building a genoscape or map of genetic variation across the breeding range and find five distinct genetic clusters within the species, with the greatest variation occurring in the western portion of the range. Genotype–environment association analyses indicate higher allelic turnover in the west than in the east, with measures of temperature surfacing as key predictors of putative adaptive genomic variation rangewide. Since broad patterns detected across a species' range represent the aggregate of many locally adapted populations, we investigate whether our broadscale analysis is consistent with a finer scale analysis. We find that top rangewide temperature‐associated loci vary in their clinal patterns (e.g., steep clines vs. fixed allele frequencies) across a hybrid zone in British Columbia, suggesting that the environmental predictors and the associated candidate loci identified in the rangewide analysis are of variable importance in this particular region. However, two candidate loci exhibit strong concordance with the temperature gradient in British Columbia, suggesting a potential role for temperature‐related barriers to gene flow and/or temperature‐driven ecological selection in maintaining putative local adaptation. This study demonstrates how patterns identified at the broad (macrogeographic) scale can be validated by investigating genotype–environment correlations at the local (microgeographic) scale. Furthermore, our results highlight the importance of considering the spatial distribution of putative adaptive variation when assessing population‐level sensitivity to climate change and other stressors.

59 BASIC BIOLOGICAL SCIENCES↗

Models and Strategies for Optimal Demand Side Management in the Chemical Industries

Deregulation and the increase of renewable electricity generation from wind and solar photovoltaics have transformed the U.S. electricity market. Economic and environmental benefits notwithstanding, the presence of renewables has increased variability and uncertainty on the supply side of the grid. Managing demand, rather than generation – a strategy referred to as “demand response (DR)” – is an attractive approach for mitigating this imbalance. DR efforts aim to reduce electricity usage during peak demand times, lessening stress on the grid. Industrial users are particularly attractive entities for DR participation since they present large, localized loads that can provide significant relief on grid demand and –unlike other large loads, such as buildings – are minimally dependent on human needs and preferences. In this project, we accomplished three main objectives. (1) We developed data-driven low-order DR scheduling-relevant dynamic models of chemical processes. Concurrently, we studied the formulation and solution of the associated optimal DR production scheduling problems. (a) A prototype air separation unit (ASU) model was used to generate simulated operating data for initial modeling efforts, which enabled the later use of industrial data for data-driven modeling. (b) We utilized Hammerstein-Wiener (HW) and Finite Step Response (FSR) models to represent nonlinear plant dynamics. (c) The HW models were linearized using exact linearization so they could potentially be embedded in power system models, which are formulated as mixed integer linear programs (MILPs). (d) We solved DR optimization problems under uncertainty and found that even naïve predictions of electricity price and product demand led to significant cost savings benefits. (2) Our DR scheduling optimization problem formulations are amenable to real-time solution. (a) We utilized Lagrangian Relaxation (LR) to efficiently solve the optimization problem by decoupling subproblems linked by complicating constraints. (b) We have achieved computation times for the 3-day DR scheduling problem of an ASU as low as 1.88 minutes. (3) Our representations of the DR behavior of chemical process as grid-level batteries were embedded in power system models. (a) For a small-scale grid, we found that incorporating the dynamics of the chemical plant in the optimal power flow calculations resulted in better resource management leading to up to 15% and 46% cost reduction for the grid and chemical plant operations, respectively, during periods of power line congestion. We have published several works dedicated to modeling and solving DR optimization problems from the user side. These were published in top peer-reviewed journals and are summarized in this report. The most recent work (and papers in preparation) considers DR scheduling from the grid side. Future efforts will consider networked plants (e.g., air separation units operating on a common pipeline) for DR participation, which is expected to amplify the capabilities of industrial DR participants to perform load-shifting. Our consideration of uncertainty in DR has inspired future directions in this area as well: we plan to develop multistage methods to fully account for the effects of uncertainty in DR scheduling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Physics Topology Optimization for Dual Flow Heat Exchangers

Current heat exchanger (HX) designs are subjected to strict constraints pertaining to their manufacturability through conventional lengthy and expensive processes consisting of subtractive, forming and brazing processes. Therefore, existing HXs are typically restricted to the classical and rather simple geometries, such as plate-fin or shell-tube geometries, with lower efficiency and larger size. To increase HX efficiencies, novel designs are needed. Recent advances in topology optimization (TO) and additive manufacturing (AM) offer significant flexibility in design and fabrication of complex geometries, with potentially superior thermo-mechanical performance and high-power density. On the other hand, there is no commercially available software tool that addresses the combined coupling of structural, fluid dynamics, and thermal with multiple materials (hot and cold streams, solid, and void space) in TO of HXs. The goal of this project is to develop a multi-physics multi-phase TO approach to enhance the performance of HXs. The optimized design will be additively manufactured and tested in a physical environment to quantify its performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NFD Methodology Report

The NetFlow Dynamics (NFD) model was developed for estimating the availability of a commodity supplied by a national- or regional-scale infrastructure following unexpected disruption of one or more of its components. The large scope of the disruptions of interest produce changes in availability lasting days to weeks. Consequently, the model does not resolve daily variations in system state and does not include the long-term processes that cause infrastructures to evolve as assets are added and removed according to owners ’planning decisions. NFD simulates fluid flow, including petroleum and other incompressible fluids, as well as natural gas and other compressible fluids, through pipeline networks characterized by limits on transmission capacity and storage. It was designed to enable efficient exploration of possible transmission system responses to large-scale disruptions lasting for days or longer. The model formulation reflects constraints on transmission and storage capacity imposed by the physical system assets. Those capacity limits are input parameters and are not derived from more basic system properties such as pipeline diameters and compressor power. A system’s response to a large disruption is controlled by operational decisions as well as damage to physical assets. The NFD model formulation allows users to efficiently consider alternative scenarios about the way remaining capacity might be used so that the analysis result appropriately reflects uncertainties about operator response.

24 POWER TRANSMISSION AND DISTRIBUTION↗