Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Crew Quarters (CQ) and Electromagnetic Interference (EMI) Measurement Facility Combined Impedance Study

This report documents an investigation into observed failures associated with conducted susceptibility testing of Crew Quarters (CQ) hardware in the Johnson Space Center (JSC) Electromagnetic Interference (EMI) Measurement Facility, and the work accomplished to identify the source of the observed behavior. Investigation led to the conclusion that the hardware power input impedance was interacting with the facility power impedance leading to instability at the observed frequencies of susceptibility. Testing performed in other facilities did not show this same behavior, pointing back to the EMI Measurement Facility power as the potential root cause. A LISN emulating the Station power bus impedance was inserted into the power circuit, and the susceptibility was eliminated from the measurements.

Scully, Robert C.↗

The Role of NASA Engineering & Safety Center (NESC) in Advancing NASA’s Astrophysics Missions (Past, Present, and Future)

The NASA Engineering & Safety Center (NESC) was established in 2003 (after the Columbia accident) to provide an independent technical resource for the resolution of challenging technical problems (through the use of studies, analysis, tests, etc.) for NASA programs and projects. Since its inception, NESC has completed nearly 1000 technical assessments for NASA’s Human Exploration and Operation Mission Directorate (HEOMD), Science Mission Directorate (SMD), Space Technology Mission Directorate (STMD), and Aeronautics Research Mission Directorate (ARMD). Of the SMD related assessments, several were for the resolution of technical problems, analysis, or studies related to NASA’s astrophysics missions in various phases of the project from design to operation. Some of the recent examples of NESC technical support for NASA astrophysics missions have been for: Hubble Space Telescope (HST), Chandra X-ray Observatory (CXO), Fermi Gamma-ray Space Telescope, Kepler Space Telescope, Transiting Exoplanet Survey Satellite (TESS), James Webb Space Telescope (JWST), and Laser Interferometer Space Antenna (LISA). In this paper, we outline some of the technical challenges faced by these astrophysics missions and describe how NESC contributed to their resolution. The case studies cover a wide range of disciplines involving space telescopes, detectors, lasers, and attitude control systems. These efforts include innovative solutions for extending the life of the missions, technical resolution of challenging problems, strategies for risk mitigation, and failure investigations combined with lessons learned reports to advance discipline knowledge, enhance NASA capabilities, and avoid future problems.

NASA↗

Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronic Medical Record Integration for Streamlined DXA Reporting

Dual-energy X-ray absorptiometry (DXA) is the most frequently performed examination to assess bone mineral density in clinical practice. Aside from images and graphical displays, many numerical values are part of DXA reports. These values are typically manually entered into the formal report through the electronic medical record or PACS workstation. The process takes time and is prone to errors. Exporting the DXA numerical data via HL7 engine to the electronic medical record was proposed to improve reporting efficiency and accuracy. The output from the DXA unit computer was reconfigured to export the report content via the HL7 interface engine into the electronic medical record. Radiology interpretive reporting was subsequently done directly in the electronic medical record. In the evaluation of errors, 100 preliminary DXA reports before the change and 100 after the change were examined. These reports were analyzed for errors that included decimal change, number transposition, negative number issue, other incorrect number error, and failure to include prior exam for comparison. In addition, report turnaround times were evaluated before and after the changes were made. Reporting time evaluations included 1-year volume prior to change (3915 reports) and 1 month post-change (206 reports). Of 100 DEXA exams before the change, 15 final reports contained 25 numerical errors. After the change, no numerical errors in the reports were identified. Exam end to final report time decreased from 2159 to 625 min on average. Automating data transmittal from the DXA modality for report generation improves accuracy and turnaround time. This approach did not require any third party software, and healthcare information security concerns were negated since we are using our standard workstations. Secondary to the affordability and applicability to the large percentage of the population using electronic medical record systems, this type of automated workflow is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of the probabilistic failure analysis methodology and other probabilistic approaches for application in aerospace structural design

Probabilistic structural analyses and design methods are steadily gaining acceptance within the aerospace industry. The safety factor approach to design has long been the industry standard, and it is believed by many to be overly conservative and thus, costly. A probabilistic approach to design may offer substantial cost savings. This report summarizes several probabilistic approaches: the probabilistic failure analysis (PFA) methodology developed by Jet Propulsion Laboratory, fast probability integration (FPI) methods, the NESSUS finite element code, and response surface methods. Example problems are provided to help identify the advantages and disadvantages of each method.

Townsend, J.↗

Failure Mechanism of Fast-Charged Lithium Metal Batteries in Liquid Electrolyte

In recent years, lithium anode has re-attracted broad interest because of the necessity of employing lithium metal in the next-generation battery technologies such as lithium sulfur (Li-S) and lithium oxygen (Li-O2) batteries. Fast capacity degradation and safety issue associated with rechargeable lithium metal batteries have been reported, although the fundamental understanding on the failure mechanism of lithium metal at high charge rate is still under debate due to the complicated interfacial chemistry between lithium metal and electrolyte. Herein, we demonstrate that, at high current density, the quick growth of porous solid electrolyte interphase towards bulk lithium, instead of towards the separator, dramatically builds up the cell impedance that directly leads to the cell failure. Understanding the lithium metal failure mechanism is very critical to gauge the various approaches used to address the stability and safety issues associated with lithium metal anode. Otherwise, all cells will fail quickly at high rates before the observation of any positive effects that might be brought from adopting the new strategies to protect lithium.

Environmental Molecular Sciences Laboratory↗

Performance degradation due to anodic failure mechanisms in lithium-ion batteries

Here, we report a mechano-chemical model for anodic degradation during fast-charging of nickel-manganese-cobalt (NMC)/graphite (C) cell due to SEI growth, lithium plating/stripping, dead lithium storage, and film fracture of composite SEI and plated lithium film. Degradation of the battery is analyzed for a range of charging rates from 1 to 6 C-rates, and the influence of plating mechanisms – lithium plating and dead lithium deposition and recovery during stripping – on the film resistance of the anode are accounted for in the model. Dynamic evolution of the interfacial properties is modeled using rule-of-mixture approach. Model predictions of plating associated stress fields are used to compute critical energy release rate for film cracking. The results indicate an increased tendency of fracture for thinner SEI film with lithium plating at higher charging rates. The process of reforming the cracked film absorbs a significant portion of the electrode current thereby reducing the cell capacity and plating efficiency. The mechano-chemical model provides an extensive analytical framework for understanding the synergistic coupling of anodic degradation mechanisms, prognosticating conditions of SEI failure, and evaluating the capacity fade and efficiency of lithium-ion battery.

25 ENERGY STORAGE↗

Hubble Space Telescope maintenance and refurbishment planning analysis

This paper presents an updated analytical approach toward the identification of Hubble Space Telescope system failures and downstates, maintenance requirements, and overall support to maintenance mission planning. Different sparing options of Orbital Replacement Units are evaluated, and the optimum spares complement that satisfies the expected servicing requirements is identified. Specific Space Telescope Reliability and maintenance Simulation Computer Program (SPATEL) updates and refinements are reported, and input data updates relevant to failure rates, downstate ground rules, and maintenance policy are addressed. A summary of the latest SPATEL outputs is provided along with maintenance analysis results.

Pizzano, F.↗

Review of Dissimilar Metal Welding for the NGNP Helical-Coil Steam Generator

The U.S. Department of Energy (DOE) is currently funding research and development of a new high temperature gas cooled reactor (HTGR) that is capable of providing high temperature process heat for industry. The steam generator of the HTGR will consist of an evaporator economizer section in the lower portion and a finishing superheater section in the upper portion. Alloy 800H is expected to be used for the superheater section, and 2.25Cr 1Mo steel is expected to be used for the evaporator economizer section. Dissimilar metal welds (DMW) will be needed to join these two materials. It is well known that failure of DMWs can occur well below the expected creep life of either base metal and well below the design life of the plant. The failure time depends on a wide range of factors related to service conditions, welding parameters, and alloys involved in the DMW. The overall objective of this report is to review factors associated with premature failure of DMWs operating at elevated temperatures and identify methods for extending the life of the 2.25Cr 1Mo steel to alloy 800H welds required in the new HTGR. Information is provided on a variety of topics pertinent to DMW failures, including microstructural evolution, failure mechanisms, creep rupture properties, aging behavior, remaining life estimation techniques, effect of environment on creep rupture properties, best practices, and research in progress to improve DMW performance. The microstructure of DMWs in the as welded condition consists of a sharp chemical concentration gradient across the fusion line that separates the ferritic and austenitic alloys. Upon cooling from the weld thermal cycle, a band of martensite forms within this concentration gradient due to high hardenability and the relatively rapid cooling rates associated with welding. Upon aging, during post weld heat treatment (PWHT), and/or during high temperature service, C diffuses down the chemical potential gradient from the ferritic 2.25Cr 1Mo steel toward the austenitic alloy. This can lead to formation of a soft C denuded zone near the interface on the ferritic steel, and nucleation and growth of carbides on the austenitic side that are associated with very high hardness. These large differences in microstructure and hardness occur over very short distances across the fusion line (~ 50 100 ?m). A band of carbides also forms along the fusion line in the ferritic side of the joint. The difference in hardness across the fusion line increases with increasing aging time due to nucleation and growth of the interfacial carbides. Premature failure of DMWs is generally attributed to several primary factors, including: the sharp change in microstructure and mechanical properties across the fusion line, the large difference in coefficient of thermal expansion (CTE) between the ferritic and austenitic alloys, formation of interfacial carbides that lead to creep cavity formation, and preferential oxidation of the ferritic steel near the fusion line. In general, the large gradient in mechanical properties and CTE serve to significantly concentrate the stress along the fusion where a creep susceptible microstructure has evolved during aging. Presence of an oxide notch can concentrate the stress even further. Details of the failure mechanism and the relative importance of each factor varies.

2.25Cr-1Mo↗

Salvage Stereotactic Body Radiotherapy (SBRT) Following In-Field Failure of Initial SBRT for Spinal Metastases

Purpose: We report our experience in salvaging spinal metastases initially irradiated with stereotactic body radiation therapy (SBRT), who subsequently progressed with imaging-confirmed local tumor progression, and were re-irradiated with a salvage second SBRT course to the same level. Methods and Materials: From a prospective database, 56 metastatic spinal segments in 40 patients were identified as having been irradiated with a salvage second SBRT course to the same level. In addition, 24 of 56 (42.9%) segments had initially been irradiated with conventional external beam radiation therapy before the first course of SBRT. Local control (LC) was defined as no progression on magnetic resonance imaging at the treated segment, and calculated according to the competing risk model. Overall survival (OS) was evaluated for each patient treated by use of the Kaplan-Meier method. Results: The median salvage second SBRT total dose and number of fractions was 30 Gy in 4 fractions (range, 20-35 Gy in 2-5 fractions), and for the first course of SBRT was 24 Gy in 2 fractions (range, 20-35 Gy in 1-5 fractions). The median follow-up time after salvage second SBRT was 6.8 months (range, 0.9-39 months), the median OS was 10.0 months, and the 1-year OS rate was 48%. A longer time interval between the first and second SBRT courses predicted for better OS (P=.02). The crude LC was 77% (43/56), the 1-year LC rate was 81%, and the median time to local failure was 3.0 months (range, 2.7-16.7 months). Of the 13 local failures, 85% (11/13) and 46% (6/13) showed progression within the epidural space and paraspinal soft tissues, respectively. Absence of baseline paraspinal disease predicted for better LC (P<.01). No radiation-induced vertebral compression fractures or cases of myelopathy were observed. Conclusion: A second course of spine SBRT, most often with 30 Gy in 4 fractions, for spinal metastases that failed initial SBRT is a feasible and efficacious salvage treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An attempt to calibrate and validate a simple ductile failure model against axial-torsion experiments on Al 6061-T651

This report details a work in progress. We have attempted to calibrate and validate a Von Mises plasticity model with the Johnson-Cook failure criterion ( Johnson & Cook , 1985 ) against a set of experiments on various specimens of Al 6061-T651. As will be shown, the effort was not successful, despite considerable attention to detail. When the model was com- pared against axial-torsion experiments on tubes, it over predicted failure by 3 x in tension, and never predicted failure in torsion, even when the tube was twisted by 4 x further than the experiment. While this result is unfortunate, it is not surprising. Ductile failure is not well understood. In future work, we will explore whether more sophisticated material mod- els of plasticity and failure will improve the predictions. Selecting the appropriate advanced material model and interpreting the results of said model are not trivial exercises, so it is worthwhile to fully investigate the behavior of a simple plasticity model before moving on to an anisotropic yield surface or a similarly complicated model.

42 ENGINEERING↗

Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion was also explored as a failure mechanism. Corroded and failed yoke samples had hydrogen concentrations of 20-60 ppm. However, the hydrogen content reduced to 4-11 ppm (similar to baseline as-received yoke samples) when the corrosion products were polished off. The hydrogen content in the scraped off corrosion product powders was >7000 ppm. These results indicate that hydrogen is primarily present in the corrosion products and not in the underlying steel. Rockwell hardness values on the corroded yoke and D-rings were R{sub c} {approx} 41-46. It was recommended to the beam clamp manufacturer that the beam clamp components be annealed to reduce the hardness values so that they are less susceptible to brittle failure. Upon annealing, hardness values of the beam clamp components reduced to R{sub c} {approx} 25. Several strategies were recommended and put in place to mitigate failure of the beam clamp components: (a) maintain hardness levels of both yokes and D-rings at R{sub c} < 35, (b) coat the yoke and D-rings with a dual coating of nickel (with 10% phosphorus) to delay corrosion and aluminum to prevent galvanic corrosion since it is more anodic to zinc, and (c) optimize coating thicknesses for nickel and aluminum while maintaining the physical integrity of the coatings. Evaluation of the Al- and Ni-coated yoke and D-ring specimens indicated they appear to have met the recommendations. Average hardness values of the dual-coated yokes were R{sub c} {approx} 25-35. Hardness values of dual-coated D-ring were R{sub c} {approx} 32. Measured average coating thicknesses for the aluminum and nickel coatings for yoke samples were 22 {micro}m (0.9 mils) and 80 {micro}m (3 mils), respectively. The D-rings also showed similar coating thicknesses. Microscopic examination showed that the aluminum coating was well bonded to the underlying nickel coating. Some observed damage was believed to be an artifact of the cutting-and-polishing steps during sample preparation for microscopy.

08 HYDROGEN↗

Long-term Outcomes and Quality of Life of 186 Patients With Primary Parotid Carcinoma Treated With Surgery and Radiotherapy at the Daniel den Hoed Cancer Center

Purpose: To assess the outcomes, toxicity, and quality of life (QOL) of patients with primary parotid carcinoma treated with surgery and postoperative radiotherapy at the Daniel den Hoed Cancer Center. Methods and Materials: Between 1995 and 2010, 186 patients with parotid carcinoma were treated with parotidectomy with or without neck dissection, followed by radiotherapy. Elective nodal irradiation (ENI) was applied to high-risk, node-negative disease. End points were locoregional control (LRC), disease-free survival (DFS), cause-specific survival (CSS), and overall survival (OS), late toxicity, and QOL. Results: After a median follow-up of 58 months (range, 4-172 months), the 5-year Kaplan-Meier estimates for LRC, DFS, CSS, and OS were 89%, 83%, 80%, and 68%, respectively. Forty-five events were reported: 24 distant metastases (DM) and 21 locoregional failures (LRF). Event-free survival rates by histological types were 89%, 78%, 76%, 74%, and 70% for acinic cell, mucoepidermoid, adenoid cystic, adenocarcinoma, and squamous cell carcinoma, respectively. More LRF were reported in patients with squamous cell and high-grade mucoepidermoid carcinoma (21% and 19%, respectively) than in patients with other histological types (p = 0.04) and more DM in patients with adenoid cystic and adenocarcinoma (20% and 19%, respectively) than in patients with other types (p = 0.03). None of the high-risk node-negative patients who received ENI developed regional failure. On multivariate analysis, T stage, N stage, grade, and presence of perineural invasion and facial paralysis correlated significantly with DFS. The 5-year cumulative incidence of grade {>=}2 late toxicity was 8%. QOL scores deteriorate during and shortly after treatment but returned in almost all scales to baseline scores within 6 months. Conclusions: Of the entire group, surgery and postoperative radiotherapy resulted in excellent outcomes with minimal side effects and preservation of good QOL scores. However, in view of the pattern of failures observed in this study, the role of adjuvant systemic or targeted therapy in patients at high risk of DM should be investigated in prospective trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chandra High Resolution Camera (HRC)

This monthly report discusses management and general status, mission support and operations, and science activities. A technical memorandum entitled "Failure Analysis of HRC Flight Relay" is included with the report.

Murray, Stephen↗