Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Lifting primordial non-Gaussianity above the noise

Primordial non-Gaussianity (PNG) in Large Scale Structures is obfuscated by the many additional sources of non-linearity. Within the Effective Field Theory approach to Standard Perturbation Theory, we show that matter non-linearities in the bispectrum can be modeled sufficiently well to strengthen current bounds with near future surveys, such as Euclid. We find that the EFT corrections are crucial to this improvement in sensitivity. Yet, our understanding of non-linearities is still insufficient to reach important theoretical benchmarks for equilateral PNG, while, for local PNG, our forecast is more optimistic. We consistently account for the theoretical error intrinsic to the perturbative approach and discuss the details of its implementation in Fisher forecasts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Procrustean entanglement concentration in quantum-classical networking

The success of a future quantum internet will rest in part on the ability of quantum and classical signals to coexist in the same optical fiber infrastructure, a challenging endeavor given the orders of magnitude differences in flux of single-photon-level quantum fields and bright classical traffic. Here, we theoretically describe and experimentally implement Procrustean entanglement concentration for polarization-entangled states contaminated with classical light, showing significant mitigation of crosstalk noise in dense wavelength-division multiplexing. Our approach leverages a pair of polarization-dependent loss emulators to attenuate highly polarized crosstalk that results from imperfect isolation of conventional signals copropagating on shared fiber links. We demonstrate our technique both on the tabletop and over a deployed quantum local area network, finding a substantial improvement of two-qubit entangled state fidelity from approximately 75% to over 92%. This local filtering technique could be used as a preliminary step to reduce asymmetric errors, potentially improving the overall efficiency when combined with more complex error-mitigation techniques in future quantum repeater networks.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-34: Setup Accuracy in Spine SBRT Using CBCT 6D Image Guidance in Comparison with 6D ExacTrac

Purpose Volumetric information of the spine captured on CBCT can potentially improve the accuracy in spine SBRT setup that has been commonly performed through 2D radiographs. This work evaluates the setup accuracy in spine SBRT using 6D CBCT image guidance that recently became available on Varian systems. Methods ExacTrac radiographs have been commonly used for Spine SBRT setup. The setup process involves first positioning patients with lasers followed by localization imaging, registration, and repositioning. Verification images are then taken providing the residual errors (ExacTracRE) before beam on. CBCT verification is also acquired in our institute. The availability of both ExacTrac and CBCT verifications allows a comparison study. 41 verification CBCT of 16 patients were retrospectively registered with the planning CT enabling 6D corrections, giving CBCT residual errors (CBCTRE) which were compared with ExacTracRE. Results The RMS discrepancies between CBCTRE and ExacTracRE are 1.70mm, 1.66mm, 1.56mm in vertical, longitudinal and lateral directions and 0.27°, 0.49°, 0.35° in yaw, roll and pitch respectively. The corresponding mean discrepancies (and standard deviation) are 0.62mm (1.60mm), 0.00mm (1.68mm), −0.80mm (1.36mm) and 0.05° (0.58°), 0.11° (0.48°), −0.16° (0.32°). Of the 41 CBCT, 17 had high-Z surgical implants. No significant difference in ExacTrac-to-CBCT discrepancy was observed between patients with and without the implants. Conclusion Multiple factors can contribute to the discrepancies between CBCT and ExacTrac: 1) the imaging iso-centers of the two systems, while calibrated to coincide, can be different; 2) the ROI used for registration can be different especially if ribs were included in ExacTrac images; 3) small patient motion can occur between the two verification image acquisitions; 4) the algorithms can be different between CBCT (volumetric) and ExacTrac (radiographic) registrations.

60 APPLIED LIFE SCIENCES↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

Local models for scatter estimation and descattering in polyenergetic X-ray tomography

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial applications. X-ray scatter, if not accounted for during reconstruction, creates a loss of contrast in CT reconstructions and introduces severe artifacts including cupping, shading, and streaks. Even when these qualitative artifacts are not apparent, scatter can pose a major obstacle in obtaining quantitatively accurate reconstructions. Our approach to estimating scatter is, first, to generate a training set of 2D radiographs with and without scatter using particle transport simulation software. To estimate scatter for a new radiograph, we adaptively fit a scatter model to a small subset of the training data containing the radiographs most similar to it. We compared local and global (fit on full data sets) versions of several X-ray scatter models, including two from the recent literature, as well as a recent deep learning-based scatter model, in the context of descattering and quantitative density reconstruction of simulated, spherically symmetrical, single-material objects comprising shells of various densities. Our results show that, when applied locally, even simple models provide state-of-the-art descattering, reducing the error in density reconstruction due to scatter by more than half.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of the Imperfection in Crab Crossing Scheme for Electron-Ion Collider

Crab crossing scheme is the essential scheme that accommodates large crossing angle without loss of luminosity in the design of Electron-Ion collider (EIC). The ideal optics and phase advances of the crab cavity pair are set to create a local crabbing bump in the interaction region (IR). However, there are always small errors in the actual lattice of IR. In this article, we will present the simulation and analytical studies on the imperfections in the crab crossing scheme in the EIC design. The tolerance of the imperfection and the possible remedies can be concluded from these studies.

Hao, Y.↗

Balancing aggregation and smoothing errors in inverse models

Inverse models use observations of a system (observation vector) to quantify the variables driving that system (state vector) by statistical optimization. When the observation vector is large, such as with satellite data, selecting a suitable dimension for the state vector is a challenge. A state vector that is too large cannot be effectively constrained by the observations, leading to smoothing error. However, reducing the dimension of the state vector leads to aggregation error as prior relationships between state vector elements are imposed rather than optimized. Here we present a method for quantifying aggregation and smoothing errors as a function of state vector dimension, so that a suitable dimension can be selected by minimizing the combined error. Reducing the state vector within the aggregation error constraints can have the added advantage of enabling analytical solution to the inverse problem with full error characterization. We compare three methods for reducing the dimension of the state vector from its native resolution: (1) merging adjacent elements (grid coarsening), (2) clustering with principal component analysis (PCA), and (3) applying a Gaussian mixture model (GMM) with Gaussian pdfs as state vector elements on which the native-resolution state vector elements are projected using radial basis functions (RBFs). The GMM method leads to somewhat lower aggregation error than the other methods, but more importantly it retains resolution of major local features in the state vector while smoothing weak and broad features.

Turner, A. J.↗

Time Lapse of World’s Largest 3-D Printed Object

Researchers at the MDF have 3D-printed a large-scale trim tool for a Boeing 777X, the world’s largest twin-engine jet airliner. The additively manufactured tool was printed on the Big Area Additive Manufacturing, or BAAM machine over a 30-hour period. The team used a thermoplastic pellet comprised of 80% ABS plastic and 20% carbon fiber from local material supplier. The tool has proven to decrease time, labor, cost and errors associated with traditional manufacturing techniques and increased energy savings in preliminary testing and will undergo further, long term testing.

36 MATERIALS SCIENCE↗

Infrared Time Lapse of World’s Largest 3D-Printed Object

Researchers at Oak Ridge National Laboratory have 3D-printed a large-scale trim tool for a Boeing 777X, the world’s largest twin-engine jet airliner. The additively manufactured tool was printed on the Big Area Additive Manufacturing, or BAAM machine over a 30-hour period. The team used a thermoplastic pellet comprised of 80% ABS plastic and 20% carbon fiber from local material supplier. The tool has proven to decrease time, labor, cost and errors associated with traditional manufacturing techniques and increased energy savings in preliminary testing and will undergo further, long term testing.

36 MATERIALS SCIENCE↗

A method for reducing the largest relative errors in Monte Carlo iterated-fission-source calculations

In Monte Carlo iterated-fission-source calculations relative uncertainties on local tallies tend to be larger in lower-power regions and smaller in higher-power regions. Reducing the largest uncertainties to an acceptable level simply by running a larger number of neutron histories is often prohibitively expensive. The uniform fission site method has been developed to yield a more spatially-uniform distribution of relative uncertainties. This is accomplished by biasing the density of fission neutron source sites while not biasing the solution. The method is integrated into the source iteration process, and does not require any auxiliary forward or adjoint calculations. For a given amount of computational effort, the use of the method results in a reduction of the largest uncertainties relative to the standard algorithm. Two variants of the method have been implemented and tested. Both have been shown to be effective. (authors)

97 MATHEMATICS AND COMPUTING↗

Efficient implicit LES method for the simulation of turbulent cavitating flows

We present a numerical method for efficient large-eddy simulation of compressible liquid flows with cavitation based on an implicit subgrid-scale model. Phase change and subgrid-scale interface structures are modeled by a homogeneous mixture model that assumes local thermodynamic equilibrium. Unlike previous approaches, emphasis is placed on operating on a small stencil (at most four cells). The truncation error of the discretization is designed to function as a physically consistent subgrid-scale model for turbulence. We formulate a sensor functional that detects shock waves or pseudo-phase boundaries within the homogeneous mixture model for localizing numerical dissipation. In smooth regions of the flow field, a formally non-dissipative central discretization scheme is used in combination with a regularization term to model the effect of unresolved subgrid scales. The new method is validated by computing standard single- and two-phase test-cases. Comparison of results for a turbulent cavitating mixing layer obtained with the new method demonstrates its suitability for the target applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction to: Imaging Light–Induced Migration of Dislocations in Halide Perovskites with 3D Nanoscale Strain Mapping

Owing to an error in properly normalizing the reconstruction phase data into atomic displacements, the strain values that we used to calculate the root mean squared local strain, ε rms , and to calculate the fraction of the crystals more strain than 1%, f, quoted in the original paper, are roughly one order of magnitude too large. This error was only discovered recently whilst performing further analysis.

36 MATERIALS SCIENCE↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

Numerical Homogenization on Approach for Stokesian Suspensions

In this technical report we investigate efficient methods for numerical simulation of active suspensions. The prototypical system is a suspension of swimming bacteria in a Newtonian fluid. Rheological and other macroscopic properties of such suspensions can differ dramatically from the same properties of the suspending fluid alone or of suspensions of similar but inactive particles. Elongated bacteria, such as E. coli or B. subtilis, swim along their principal axis, propelling themselves with the help of flagella, attached at the anterior of the organism and pushing it forward in the manner of a propeller. They interact hydrodynamically with the surrounding fluid and, because of their asymmetrical shape, have the propensity to align with the local flow. This, along with the dipolar nature of bacteria (the two forces a bacterium exerts on a fluid - one due to self-propulsion and the other opposing drag - have equal magnitude and point in opposite directions), causes nearby bacteria to tend to align, resulting in a intermittent local ordering on the mesoscopic scale, which is between the microscopic scale of an individual bacterium and the macroscopic scale of the suspension (e.g., its container). The local ordering is sometimes called a collective mode or collective swimming. Thanks to self-propulsion, collective modes inject momentum into the fluid in a coherent way. This enhances the local strain rate without changing the macroscopic stress applied at the boundary of the container. The macroscopic effective viscosity of the suspension is defined roughly as the ratio of the applied stress to the bulk strain rate. If local alignment and therefore local strain-rate enhancement, are significant, the effective viscosity can be appreciably lower than that of the corresponding passive suspension or even of the surrounding fluid alone. Indeed, a sevenfold decrease in the effective viscosity was observed in experiments with B. subtilis. More generally, local collective swimming resulting from bacterial alignment can significantly alter other macroscopic properties of the suspension, such as the oxygen diffusivity and mixing rates. In order to understand the unique macroscopic properties of active suspensions the connection between microscopic swimming and alignment dynamics and the mesoscopic pattern formation must be clarified. This is difficult to do analytically in the fully general setting of moderately dense suspensions, because of the large number of bacteria involved (approx. 10 10 cm -3 in experiments) and the complex, time-dependent geometry of the system. Many reduced analytical models of bacterial have been proposed, but all of them require validation. While comparison with experiment is the ultimate test of a model's fidelity, it is difficult to conduct experiments matched to these models assumptions. Numerical simulation of the microscopic dynamics is an acceptable substitute, but it runs into the problem of having to discretize the fluid domain with a fine-grained boundary (the bacteria) and update the discretization as the domain evolves (bacteria move). This leads to a prohibitively high number of degrees of freedom and prohibitively high setup costs per timestep of simulation. In this technical report we propose numerical methods designed to alleviate these two difficulties. We indicate how to (1) construct an optimal discretization in terms of the number of degrees of freedom per digit of accuracy and (2) optimally update the discretization as the simulation evolves. The technical tool here is the derivation of rigorous error bounds on the error in the numerical solution when using our proposed discretization at the initial time as well as after a given elapsed simulation time. These error bounds should guide the construction of practical discretization schemes and update strategies. Our initial construction is carried out by using a theoretically convenient, but practically prohibitive spectral basis, which is a Galerkin basis of functions with global support. At the end of this report we propose localization techniques while maintaining acceptable error bounds. No numerical experiments were conducted as part of this study, but we envision that we may undertake such studies and further development of the method, jointly or individually.

60 APPLIED LIFE SCIENCES↗

Local gravitational redshifts can bias cosmological measurements

Measurements of cosmological parameters via the distance-redshift relation usually rely on models that assume a homogenous universe. It is commonly presumed that the large-scale structure evident in our Universe has a negligible impact on the measurement if distances probed in observations are sufficiently large (compared to the scale of inhomogeneities) and are averaged over different directions on the sky. This presumption does not hold when considering the effect of the gravitational redshift caused by our local gravitational potential, which alters light coming from all distances and directions in the same way. Despite its small magnitude, this local gravitational redshift gives rise to noticeable effects in cosmological inference using SN Ia data. Assuming conservative prior knowledge of the local potential given by sampling a range of gravitational potentials at locations of Milky-Way-like galaxies identified in cosmological simulations, we show that ignoring the gravitational redshift effect in a standard data analysis leads to an additional systematic error of ∼1% in the determination of density parameters and the dark energy equation of state. We conclude that our local gravitational field affects our cosmological inference at a level that is important in future observations aiming to achieve percent-level accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiple-copy state discrimination: Thinking globally, acting locally

We theoretically investigate schemes to discriminate between two nonorthogonal quantum states given multiple copies. We consider a number of state discrimination schemes as applied to nonorthogonal, mixed states of a qubit. In particular, we examine the difference that local and global optimization of local measurements makes to the probability of obtaining an erroneous result, in the regime of finite numbers of copies N, and in the asymptotic limit as N{yields}{infinity}. Five schemes are considered: optimal collective measurements over all copies, locally optimal local measurements in a fixed single-qubit measurement basis, globally optimal fixed local measurements, locally optimal adaptive local measurements, and globally optimal adaptive local measurements. Here an adaptive measurement is one in which the measurement basis can depend on prior measurement results. For each of these measurement schemes we determine the probability of error (for finite N) and the scaling of this error in the asymptotic limit. In the asymptotic limit, it is known analytically (and we verify numerically) that adaptive schemes have no advantage over the optimal fixed local scheme. Here we show moreover that, in this limit, the most naive scheme (locally optimal fixed local measurements) is as good as any noncollective scheme except for states with less than 2% mixture. For finite N, however, the most sophisticated local scheme (globally optimal adaptive local measurements) is better than any other noncollective scheme for any degree of mixture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining Magnetic Field Directions and Omni-directional Fluxes of Particles from STPSat-6 ZPS Plasma Measurements

This report summarizes our recent data derivation efforts on STPSat-6 ZPS plasma measurements, presenting final outcomes. We begin by outlining the methodology developed to determine local magnetic field directions from measured directional intensities of ~20 keV ions, leveraging symmetry in particles’ pitch-angle distributions, and the determined field directions over a storm period are shown with errors analyzed through comparison with NOAA GOES measurements. Next, we further assess the validity of the method and quantify its overall high performance while acknowledging certain caveats. Finally, given local magnetic field directions and ZPS data, we explain how omni-directional fluxes of particles can be derived from ZPS measurements with limited directional coverage, and estimate the related errors under several theoretical scenarios. The methods developed in this study can be applied for processing and augmenting ZPS data for the next, and the insights gained here can also inform instrument design in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗