Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

LANDSAT imagery of the Central Andes

The central Andes of South America extend from approximately 14 deg. S to 28 deg. S as an unbroken chain of mountains and volcanoes over 2000 km long. It is here that the Nazca plate dives under the South American plate at angles varying from 10 deg to 30 deg. Very little is known about the volcanoes comprising this classic, subduction-type plate margin. A catalogue of the volcanoes in the central Andes is being prepared by Dr. P.W. Francis and Dr. C.A. Wood at the NASA Lunar and Planetary Institute. At present, more than 800 volcanoes of Cenozoic age have been recognized in the chain, with an estimated 75-80 major, active Quarternary volcanoes. Approximately one hundred 1536 x 1536 pixel color composite Optronics positives were produced from six full LANDSAT Thermatic Mapper scenes and three partial TM scenes. These positives cover a large portion of the central Andes. The positives were produced from LANDSAT data using the VAX imaging package, LIPS. The scenes were first transferred from magnetic tape to disk. The LIPS package was then used to select volcanically interesting areas which were then electronically enhanced. Finally, the selected areas were transferred back to tape and printed on the Optronics equipment. The pictures are color composites using LANDSAT TM bands 7,4, and 2 in the red, green, and blue filters, respectively.

Komer, C. A.↗

Frequency-Tracking-Error Detector

Frequency-tracking-error detector compares average period of output signal from band-pass tracking filter with average period of signal of frequency 100 f(sub 0) that controls center frequency f(sub 0) of tracking filter. Measures difference between f(sub 0) and frequency of one of periodic components in output of bearing sensor. Bearing sensor is accelerometer, strain gauge, or deflectometer mounted on bearing housing. Detector part of system of electronic equipment used to measure vibrations in bearings in rotating machinery.

Randall, Richard L.↗

Low-temperature operation of a Buck DC/DC converter

Low-temperature (77 K) operation of a 42/28 V, 175 W, 50 kHz PWM Buck DC/DC converter designed with commercially available components is reported. Overall, the converter losses decreased at 77 K compared to room temperature operation. A full-load efficiency of 97 percent was recorded at liquid-nitrogen temperature, compared to 95.8 percent at room temperature. Power MOSFET operation improved significantly where as the output rectifier operation deteriorated at low-temperature. The performance of the output filter inductor and capacitor did not change significantly at 77 K compared to room temperature performance. It is possible to achieve high-density and high efficiency power conversion at low-temperatures due to improved electronic, electrical and thermal properties of materials.

Ray, Biswajit↗

NASA Tech Briefs, August 2012

Topics covered include: Mars Science Laboratory Drill; Ultra-Compact Motor Controller; A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator; Shape Memory Composite Hybrid Hinge; Binding Causes of Printed Wiring Assemblies with Card-Loks; Coring Sample Acquisition Tool; Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge; 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF; Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer; Discontinuous Mode Power Supply; Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI; Hardware for Accelerating N-Modular Redundant Systems for High-Reliability Computing; Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry; High-Thermal-Conductivity Fabrics; Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes; Electrospun Nanofiber Coating of Fiber Materials: A Composite Toughening Approach; Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms; Saliva Preservative for Diagnostic Purposes; Hands-Free Transcranial Color Doppler Probe; Aerosol and Surface Parameter Retrievals for a Multi-Angle, Multiband Spectrometer LogScope; TraceContract; AIRS Maps from Space Processing Software; POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation; Space Operations Learning Center; OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems; Large Eddy Simulation (LES) of Particle-Laden Temporal Mixing Layers; Projection of Stabilized Aerial Imagery Onto Digital Elevation Maps for Geo-Rectified and Jitter-Free Viewing; Iterative Transform Phase Diversity: An Image-Based Object and Wavefront Recovery; 3D Drop Size Distribution Extrapolation Algorithm Using a Single Disdrometer; Social Networking Adapted for Distributed Scientific Collaboration; General Methodology for Designing Spacecraft Trajectories; Hemispherical Field-of-View Above-Water Surface Imager for Submarines; and Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly.

Source record↗

Indoor Ground Testing of a Small UAS Sense and Avoid Airborne Doppler Radar

The National Aeronautics and Space Administration’s Unmanned Aircraft System (UAS) Traffic Management (UTM) project is researching prototype technologies needed to ensure safe integration of UAS operations into the National Airspace System (NAS). Within the UTM Concept of Operations, UAS would be equipped with on-board Sense and Avoid (SAA) technology to continually monitor for manned and unmanned aircraft in its vicinity while operating beyond visual line of sight in uncontrolled airspace. To support this effort, a candidate commercially available 24.5 GHz Doppler radar was selected and evaluated to determine if the technology could reliably support minimum requirements for SAA applications of small UAS (sUAS). Indoor ground tests were conducted inside the NASA Langley Research Center’s Experimental Test Range (ETR) from a stationary platform to evaluate the Doppler radar performance characteristics and gain operational proficiency before the radar was authorized to transmit outdoors. A high speed linear rail system was developed for the radar evaluation and was shown to be an effective method to generate Doppler radar targets of known radar cross section. The accuracy of the range and velocity reported by the radar was shown to be dependent on the Kalman filter state variance parameter settings. Antenna measurements were collected with the radar installed both on and off a sUAS to quantify the relative antenna gain, beam width and side lobe levels of the radar’s Metamaterial Electronically Scanning Array (MESA) antennas at boresight and extreme field of view pointing vectors. The relative antenna gain measured 2.6 dB lower at extreme field view angles compared to the boresight radiation pattern.

Szatkowski, George N.↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

Mini-O, simple Omega receiver hardware for user education

A problem with the Omega system is a lack of suitable low cost hardware for the small user community. A collection of do it yourself circuit modules are under development intended for use by educational institutions, small boat owners, aviation enthusiasts, and others who have some skills in fabricating their own electronic equipment. Applications of the hardware to time frequency standards measurements, signal propagation monitoring, and navigation experiments are presented. A family of Mini-O systems have been constructed varying from the simplest RF preamplifiers and narrowband filters front-ends, to sophisticated microcomputer interface adapters.

Burhans, R. W.↗

The Pioneer Venus Orbiter plasma wave investigation

The Pioneer Venus plasma wave instrument has a self-contained balanced electric dipole (effective length = 0.75 m) and a 4-channel spectrum analyzer (30% bandwidth filters with center frequencies at 100 Hz, 730 Hz, and 30 kHz). The channels are continuously active and the highest Orbiter telemetry rate (2048 bits/sec) yields 4 spectral scans/sec. The total mass of 0.55 kg includes the electronics, the antenna, and the antenna deployment mechanism. This report contains a brief description of the instrument design and a discussion of the in-flight performance.

Scarf, F. L.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Improvements to an electromagnetic position sensor for a magnetic suspension wind tunnel

The original and improved designs for the Electromagnetic Position Sensor (EPS), an electronic instrument and associated multicoil sensor for the six-inch Magnetic Suspension and Balance System (MSBS) that measures aerodynamic model position, are compared. The EPS power amplifier and oscillator, input nulling stage, reference voltage generators, bandpass filter, summation and demodulation, and final stage are described. The effects of the MSBS and of model materials on the performance are addressed.

Daniels, Taumi S.↗

Transport of Photoelectrons in the Nightside Magnetosphere

Kinetic modeling results are analyzed to examine the transport of photoelectrons through the nightside inner magnetosphere. A natural filter exists on the nightside for these particles, with Coulomb collisions eroding the distribution at low energies and low L shells, and magnetospheric convection compressing the flux tubes as they corotate towards dawn. This leads to an electron population with very distinctive features. It is shown that, for low activity levels, a band of photoelectrons forms between L=4 and 6 that extends throughout the nightside local times and into the morning sector. Modeled energy and pitch angle distributions are presented to show the development and features of this electron band, as well as their influences on the thermal plasma. Such a population should be observable in satellite spectrometer measurements.

Khazanov, G. V.↗

Time Series Analysis in the Search for Other Worlds Through Transit Photometry

The Kepler Mission launched in June 2009 to commence NASA's first mission to search for potentially habitable, Earth-size planets orbiting Sun-like stars. Kepler discovered explanets via the transit method: searching for minute (100 ppm) drops in brightness lasting 1 - 13 hours corresponding to occasions where the planet crosses the face of its host star from Kepler's point of view. The exquisite precision required to carry out the Kepler mission (20 ppm in 6.5 hours) pushed astronomical time series analysis to the limits, and motivated the development of novel algorithmic approaches. Transit signatures of rocky planets are often dwarfed by the intrinsic stellar variability, which is not white noise, and often is non-stationary, and by instrumental systematic effects, which can include transients and electronic artifacts. Surmounting this challenging regime of weak, temporally compact, periodic signals in observation noise with strong systematics and other sources of variability motivated the development of 1) an overcomplete, non-decimated, wavelet-based matched filter to jointly estimate the properties of the non-stationary, non-white observation noise process, and 2) a multi-scale, maximum a posteriori (msMAP) approach to identifying and removing instrumental systematic effects. After over nine years of observations, the Kepler spacecraft finally ran out of fuel in November 2018, ending its data collection activities. Over 2300 planets were discovered by Kepler in its primary mission, and over 355 have been discovered by K2, the repurposed mission that followed Kepler's primary mission after the loss of a second reaction wheel in May 2013. We have ported the Kepler science pipeline for the Transiting Exoplanet Survey Satellite (TESS) Mission, which began science observations in July 2019, and report initial results and performance of the modified science pipeline.The Kepler and TESS Missions are supported by NASA's Science Mission Directorate.

transit surveys↗

Combined Coherent Manipulation and Single-Shot Measurement of an Electron Spin in a Quantum Dot (Final Technical Report)

Semiconductor quantum dots (QDs) are promising candidates to act as single-photon sources and/or quantum bits in future optical quantum information applications. Their excellent optical properties such as high brightness, single-photon purity, and narrow linewidth have potential utility in many areas. One challenge is to control the energy levels of the QD without using a magnetic field. The AC Stark effect offers the opportunity to do this. We have demonstrated record-large AC Stark shifts of the energy states of a single charged QD. We showed that the shifts can be applied in a spin-selective manner by controlling the polarization of the laser producing the AC Stark effect. In order to characterize the effect, we developed a novel spectral filtering scheme to discriminate the high-power AC Stark laser from the QD fluorescence. We also developed a compact, low-cost, homemade polarimeter to help control the polarization of the AC Stark laser, which enabled the spin selectivity of the AC Stark effect. With the practical capabilities thus developed, we learned that the spin-selective AC Stark effect causes electron spin pumping, which in turn causes nuclear spin pumping via the hyperfine interaction. The nuclear spin pumping causes a mean field Zeeman interaction between the nuclear spin ensemble and the electron trapped in the QD, resulting in the so-called Overhauser shift. The magnitude of the Overhauser shift and the measured linewidth of the QD’s optical transitions enabled characterization of the mean nuclear spin polarization and fluctuations. The potentially rapid (ns-scale) control of the QD energy levels and nuclear spin polarization will enable measurements of electron and nuclear spin polarization in the absence of any real magnetic field, which is a completely unique capability. The ability to rapidly apply a spin-selective AC Stark effect in the presence of a weak real magnetic field will allow control of the polarization selection rules of the transitions, enabling all single-qubit operations on the electron spin, i.e., initialization, coherent manipulation, and quantum non-demolition measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface composition of solid-rocket exhausted aluminum oxide particles

Particulate samples of aluminum oxide were collected on Teflon filters from the exhaust plume of the Space Shuttle (STS-61A, October 30, 1985) over the altitude interval 4.6-7.6 km immediately after launch. These particles were analyzed using SEM, energy-dispersive X-ray analysis, electron spectroscopy for chemical analysis, X-ray fluorescent spectroscopy, and conventional wet-chemical techniques. The samples were 0.6-1.0 percent surface-chlorided (chlorided meaning predominantly aluminum chlorides and oxychlorides, possibly including other adsorbed forms of chloride) by weight. This level of chloriding is about one-third of the amount determined previously from laboratory-prepared alumina and surface site samples of solid-rocket-produced alumina (SRPA) after both had been exposed to moist HCl vapor at temperatures down to ambient. This level is equivalent to previous laboratory results with samples exposed to moist HCl at temperatures above the boiling point of water. It is suggested that the present lower chloriding levels, determined for samples from a 'dry' Shuttle exhaust cloud, underscore the importance of a liquid water/hydrochloric acid phase in governing the extent of surface chloriding of SRPA. The reduced chloriding is not trivial with respect to potential physical/chemical modification of the SRPA particle surfaces and their corresponding interaction with the atmosphere.

Cofer, Wesley R., III↗

Automated target recognition and tracking using an optical pattern recognition neural network

The on-going development of an automatic target recognition and tracking system at the Jet Propulsion Laboratory is presented. This system is an optical pattern recognition neural network (OPRNN) that is an integration of an innovative optical parallel processor and a feature extraction based neural net training algorithm. The parallel optical processor provides high speed and vast parallelism as well as full shift invariance. The neural network algorithm enables simultaneous discrimination of multiple noisy targets in spite of their scales, rotations, perspectives, and various deformations. This fully developed OPRNN system can be effectively utilized for the automated spacecraft recognition and tracking that will lead to success in the Automated Rendezvous and Capture (AR&C) of the unmanned Cargo Transfer Vehicle (CTV). One of the most powerful optical parallel processors for automatic target recognition is the multichannel correlator. With the inherent advantages of parallel processing capability and shift invariance, multiple objects can be simultaneously recognized and tracked using this multichannel correlator. This target tracking capability can be greatly enhanced by utilizing a powerful feature extraction based neural network training algorithm such as the neocognitron. The OPRNN, currently under investigation at JPL, is constructed with an optical multichannel correlator where holographic filters have been prepared using the neocognitron training algorithm. The computation speed of the neocognitron-type OPRNN is up to 10(exp 14) analog connections/sec that enabling the OPRNN to outperform its state-of-the-art electronics counterpart by at least two orders of magnitude.

Chao, Tien-Hsin↗

Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet Radiation Facility (SURF) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland.

Woods, Thomas N.↗

Polarized Light Microscopy

Polarized light microscopy (PLM) is a technique which employs the use of polarizing filters to obtain substantial optical property information about the material which is being observed. This information can be combined with other microscopy techniques to confirm or elucidate the identity of an unknown material, determine whether a particular contaminant is present (as with asbestos analysis), or to provide important information that can be used to refine a manufacturing or chemical process. PLM was the major microscopy technique in use for identification of materials for nearly a century since its introduction in 1834 by William Fox Talbot, as other techniques such as SEM (Scanning Electron Microscopy), FTIR (Fourier Transform Infrared spectroscopy), XPD (X-ray Powder Diffraction), and TEM (Transmission Electron Microscopy) had not yet been developed. Today, it is still the only technique approved by the Environmental Protection Agency (EPA) for asbestos analysis, and is often the technique first applied for identification of unknown materials. PLM uses different configurations in order to determine different material properties. With each configuration additional clues can be gathered, leading to a conclusion of material identity. With no polarizing filter, the microscope can be used just as a stereo optical microscope, and view qualities such as morphology, size, and number of phases. With a single polarizing filter (single polars), additional properties can be established, such as pleochroism, individual refractive indices, and dispersion staining. With two polarizing filters (crossed polars), even more can be deduced: isotropy vs. anisotropy, extinction angle, birefringence/degree of birefringence, sign of elongation, and anomalous polarization colors, among others. With the use of PLM many of these properties can be determined in a matter of seconds, even for those who are not highly trained. McCrone, a leader in the field of polarized light microscopy, often advised, If you cant determine a specific optical property of a particle after two minutes, move onto another configuration. Since optical properties can be seen so very quickly and easily under polarized light, it is only necessary to spend a maximum of two minutes on a technique to determine a particular property, though often only a few seconds are required.

Engineering↗

A Synthesis of Star Calibration Techniques for Ground-Based Narrowband Electron-Multiplying Charge-Coupled Device Imagers Used in Auroral Photometry

A technique is presented for the periodic and systematic calibration of ground-based optical imagers. It is important to have a common system of units (Rayleighs or photon flux) for cross comparison as well as self-comparison over time. With the advancement in technology, the sensitivity of these imagers has improved so that stars can be used for more precise calibration. Background subtraction, flat fielding, star mapping, and other common techniques are combined in deriving a calibration technique appropriate for a variety of ground-based imager installations. Spectral (4278, 5577, and 8446 A ) ground-based imager data with multiple fields of view (19, 47, and 180 deg) are processed and calibrated using the techniques developed. The calibration techniques applied result in intensity measurements in agreement between different imagers using identical spectral filtering, and the intensity at each wavelength observed is within the expected range of auroral measurements. The application of these star calibration techniques, which convert raw imager counts into units of photon flux, makes it possible to do quantitative photometry. The computed photon fluxes, in units of Rayleighs, can be used for the absolute photometry between instruments or as input parameters for auroral electron transport models.

Grubbs, Guy II↗