Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamics testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Corrosion Testing Trade Study on Testing Methods in Molten Salts

In assessing molten salt compatibility with structural materials, static testing is often reported because it is easy to conduct. However, in order to assess mass transfer, where material dissolves in the salt in the hot section and may precipitate out of the liquid in colder regions, a flowing salt experiment in a temperature gradient is needed. While a forced convection or pumped loop produces prototypic flowing conditions, it also is a multi-million dollar investment. Among the less expensive dynamic testing options, the thermal convection loop (TCL) was favored during the 1960’s development of molten salt reactor technology. Because the workforce and core facilities are currently available to conduct TCL experiments, it is the least expensive strategy to evaluate candidate structural alloys in flowing molten salt conditions.

36 MATERIALS SCIENCE↗

Honeycomb Core Permeability Under Mechanical Loads

A method for characterizing the air permeability of sandwich core materials as a function of applied shear stress was developed. The core material for the test specimens was either Hexcel HRP-3/16-8.0 and or DuPont Korex-1/8-4.5 and was nominally one-half inch thick and six inches square. The facesheets where made of Hercules' AS4/8552 graphite/epoxy (Gr/Ep) composites and were nominally 0.059-in. thick. Cytec's Metalbond 1515-3M epoxy film adhesive was used for co-curing the facesheets to the core. The permeability of the specimens during both static (tension) and dynamic (reversed and non-reversed) shear loads were measured. The permeability was measured as the rate of air flow through the core from a circular 1-in2 area of the core exposed to an air pressure of 10.0 psig. In both the static and dynamic testing, the Korex core experienced sudden increases in core permeability corresponding to a core catastrophic failure, while the URP core experienced a gradual increase in the permeability prior to core failure. The Korex core failed at lower loads than the HRP core both in the transverse and ribbon directions.

Glass, David E.↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

A potential new test for unseen matter in the outer solar system

The recent development of trapped-ion frequency standards, which offer high stability over long time periods, provides us with a potential new method for detecting unseen matter in the outer solar system. A distribution of matter or a planetary body could produce a measurable gravitational redshift of the radio signal received from a spacecraft equipped with an ultrastable frequency standard. Trapped-ion standards have a potential frequency stability of 1 part in 10(exp 16) or better over long time periods (greater than 10(exp 6) s). We consider the potential improvements this method could yield over conventional dynamical tests for unseen matter in the outer solar system possible now or anticipated in the near future.

Krisher, Timothy P.↗

A parametric study of slow dynamic nonlinear elasticity with comparisons to models

Several phenomenological models that aspire to quantitative description of anomalous nonlinear mesoscopic elasticity are reviewed and compared with laboratory measurements. This class of nonlinearity, best known perhaps for slow dynamics and aging, is seen widely in imperfectly consolidated granular solids but is not well understood. Typical slow dynamic tests show that a modest conditioning oscillatory "pump" strain depresses material stiffness, which then recovers like the logarithm of time after conditioning ceases. Several phenomenological models based on physical arguments have been proposed that predict the material stiffness response to arbitrary pump strain histories during conditioning and recovery. Approximate closed form and numerical solutions to the models are presented that predict the quantitative influence of three key pump parameters: the pump's strain amplitude, the pump's strain rate, and the pump’s duration. Laboratory measurements on Berea sandstone, concrete and a confined single aluminum bead find that slow dynamic responses are linear in pump strain and independent of pump frequency. Measurements also show that, after pump-off, stiffness recovers over times far longer than the pump duration. These observations and others are compared to model predictions. One of the considered models, based on a picture of fast brittle damage and slow healing, successfully matches all these behaviors.

36 MATERIALS SCIENCE↗

A method for landing gear modeling and simulation with experimental validation

This document presents an approach for modeling and simulating landing gear systems. Specifically, a nonlinear model of an A-6 Intruder Main Gear is developed, simulated, and validated against static and dynamic test data. This model includes nonlinear effects such as a polytropic gas model, velocity squared damping, a geometry governed model for the discharge coefficients, stick-slip friction effects and a nonlinear tire spring and damping model. An Adams-Moulton predictor corrector was used to integrate the equations of motion until a discontinuity caused by a stick-slip friction model was reached, at which point, a Runga-Kutta routine integrated past the discontinuity and returned the problem solution back to the predictor corrector. Run times of this software are around 2 mins. per 1 sec. of simulation under dynamic circumstances. To validate the model, engineers at the Aircraft Landing Dynamics facilities at NASA Langley Research Center installed one A-6 main gear on a drop carriage and used a hydraulic shaker table to provide simulated runway inputs to the gear. Model parameters were tuned to produce excellent agreement for many cases.

Daniels, James N.↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Characterization of Low-Velocity Impact Damage in Toughened Non-Crimp Fabric Laminates

The damage response of resin-infused composites was investigated using quasi-static indentation (QSI) and instrumented drop-weight impact testing. The test specimens were composed of six layers of non-crimp fabrics where each layer contained +45°, 90°, −45°, and 0° plies. The goals of the testing were to identify damage responses that may differ from traditional thermoset materials and provide damage characterization data to evaluate current damage prediction analyses and aid improvements to current damage models. The damage was characterized using X-ray computed tomography (CT) and ultrasonic testing (UT). Incremental QSI loading was used on a single specimen to investigate damage growth in nine steps at progressively higher loads. Realtime acoustic emission data were used to determine the unloading points. Unlike typical thermoset composites, the force-displacement was smooth and showed no obvious indications of damage. The primary damage consisted of large lines of fiber fracture on the plies near the impact surface and delaminations through the thickness. Nine specimens were impacted at nominal impact energies of 25 ft-lbs, 30 ft-lbs, and 35 ft-lbs. The force histories at each energy followed nearly identical paths. Again, no obvious signs of damage were observed in any of the force histories. The general damage response in the dynamic tests was similar to the QSI-loaded specimens. However, repeat specimens impacted with a given impact energy showed variations in the damage. Some characteristics of the damage response were different than those typically observed in thermoset composites and will need to be evaluated using current analysis methods.

Composite Materials↗

Characterization of Low-Velocity Impact Damage in Toughened Non-Crimp Fabric Laminates

The damage response of resin-infused composites was investigated using quasi-static indentation (QSI) and instrumented drop-weight impact testing. The test specimens were composed of six layers of non-crimp fabrics where each layer contained +45°, 90°, −45°, and 0° plies. The goals of the testing were to identify damage responses that may differ from traditional thermoset materials and provide damage characterization data to evaluate current damage prediction analyses and aid improvements to current damage models. The damage was characterized using X-ray computed tomography (CT) and ultrasonic testing (UT). Incremental QSI loading was used on a single specimen to investigate damage growth in nine steps at progressively higher loads. Realtime acoustic emission data were used to determine the unloading points. Unlike typical thermoset composites, the force-displacement was smooth and showed no obvious indications of damage. The primary damage consisted of large lines of fiber fracture on the plies near the impact surface and delaminations through the thickness. Nine specimens were impacted at nominal impact energies of 25 ft-lbs, 30 ft-lbs, and 35 ft-lbs. The force histories at each energy followed nearly identical paths. Again, no obvious signs of damage were observed in any of the force histories. The general damage response in the dynamic tests was similar to the QSI-loaded specimens. However, repeat specimens impacted with a given impact energy showed variations in the damage. Some characteristics of the damage response were different than those typically observed in thermoset composites and will need to be evaluated using current analysis methods.

Composite Materials↗

Status report and preliminary results of the spacecraft control laboratory experiment

The Spacecraft Control Laboratory Experiment (SCOLE) was conceived to provide a physical test bed for investigation of control techniques for large flexible spacecraft. The SCOLE problem is defined as two design challenges. The first challenge is to design control laws for a mathematical model of a large antenna attached to the space shuttle by a long flexible mast. The second challenge is to design and implement a control scheme on a laboratory representation of the structure modelled in the first part. Control sensors and actuators are typical of those which the control designer would have to deal with on an actual spacecraft. The primary control processing computer is representative of the capacity and speed which may be expected in actual flight computers. A brief description is given of the laboratory apparatus along with some preliminary results of structural dynamics tests and actuator effectiveness tests.

Williams, Jeffrey P.↗

Psyche Hardware Abstraction Simulation Environment (PHASE): Development of High-Fidelity Downlink Model for Flight Software Performance Testing

NASA’s Katherine Johnson Independent Verification and Validation (IV&V) Independent Test Capability (ITC) Team develops high fidelity software-only simulations (or “digital-twins”) of NASA’s most critical missions that are then used for software verification and validation (V&V). One such digital-twin simulator nearing maturity is the Psyche Hardware Abstraction Simulation Environment (PHASE). PHASE utilizes an instruction set simulator along with ITC-developed avionics models. PHASE includes a newly-developed model of the telecom hardware with a high-fidelity downlink interface, capable of supporting reconfigurable downlink data rates and transmission modes. The different downlink transmission modes allow more processing to be ceded from software onto the telecom hardware. Thus, we are able to monitor the performance of the downlink software module in the time-partitioned OS and perform more realistic dynamic testing based on software’s resource utilization. This presentation will cover PHASE, avionics modeling, the downlink model, and its usage for flight software performance testing.

modeling↗

Extraction-Separation Performance and Dynamic Modeling of Orion Test Vehicles with Adams Simulation: 3rd Edition

NASA's Orion Capsule Parachute Assembly System (CPAS) Project is now in the qualification phase of testing, and the Adams simulation has continued to evolve to model the complex dynamics experienced during the test article extraction and separation phases of flight. The ability to initiate tests near the upper altitude limit of the Orion parachute deployment envelope requires extractions from the aircraft at 35,000 ft-MSL. Engineering development phase testing of the Parachute Test Vehicle (PTV) carried by the Carriage Platform Separation System (CPSS) at altitude resulted in test support equipment hardware failures due to increased energy caused by higher true airspeeds. As a result, hardware modifications became a necessity requiring ground static testing of the textile components to be conducted and a new ground dynamic test of the extraction system to be devised. Force-displacement curves from static tests were incorporated into the Adams simulations, allowing prediction of loads, velocities and margins encountered during both flight and ground dynamic tests. The Adams simulation was then further refined by fine tuning the damping terms to match the peak loads recorded in the ground dynamic tests. The failure observed in flight testing was successfully replicated in ground testing and true safety margins of the textile components were revealed. A multi-loop energy modulator was then incorporated into the system level Adams simulation model and the effect on improving test margins be properly evaluated leading to high confidence ground verification testing of the final design solution.

Varela, Jose G.↗

Ground Testing A 20-Meter Inflation Deployed Solar Sail

Solar sails have been proposed for a variety of future space exploration missions and provide a cost effective source of propellantless propulsion. Solar sails span very large areas to capture and reflect photons from the Sun and are propelled through space by the transfer of momentum from the photons to the solar sail. The thrust of a solar sail, though small, is continuous and acts for the life of the mission without the need for propellant. Recent advances in materials and ultra-low mass gossamer structures have enabled a host of useful space exploration missions utilizing solar sail propulsion. The team of L Garde, NASA Jet Propulsion Laboratory (JPL), Ball Aerospace, and NASA Langley Research Center, under the direction of the NASA In-Space Propulsion Office (ISP), has been developing a scalable solar sail configuration to address NASA s future space propulsion needs. The 100-m baseline solar sail concept was optimized around the one astronomical unit (AU) Geostorm mission, and features a Mylar sail membrane with a striped-net sail suspension architecture with inflation-deployed sail support beams consisting of inflatable sub-Tg (glass transition temperature) rigidizable semi-monocoque booms and a spreader system. The solar sail has vanes integrated onto the tips of the support beams to provide full 3-axis control of the solar sail. This same structural concept can be scaled to meet the requirements of a number of other NASA missions. Static and dynamic testing of a 20m scaled version of this solar sail concept have been completed in the Space Power Facility (SPF) at the NASA Glenn Plum Brook facility under vacuum and thermal conditions simulating the operation of a solar sail in space. This paper details the lessons learned from these and other similar ground based tests of gossamer structures during the three year solar sail project.

Mann, Troy↗

Damping and mode shape modification for additively manufactured walls with captured powder

Here, this paper describes the fabrication, modeling, and dynamic testing of laser powder bed fusion stainless steel walls with captured powder cores. The purpose of the study is to determine the increased structural damping, or energy dissipation, and mode shape modification caused by the inclusion of the unmelted powder core within the solid walls. It is shown experimentally that the damping increases with larger powder core width and that the damping addition is mode dependent. Damping increases over the solid wall values by factors of 2.9–225 are reported depending on the mode number and core width. It is also seen that the mode shapes are distorted relative to the solid wall results as the core width is increased and wall thickness is decreased. Comparisons with finite element models confirm this trend.

42 ENGINEERING↗

High-Fidelity Numerical Investigation on Elucidating Sodium Heat Transfer Characteristics for 37-Pin Wire-Wrapped Fuel Bundle in the PLANDTL Facility

This study involved a Reynolds-averaged Navier-Stokes- (RANS-) based computational fluid dynamics (CFD) analysis of the 37-pin wire-wrapped fuel bundle of the PNC Plant dynamics test loop (PLANDTL) facility. Previously, mainly the hydrodynamic phenomena of the wire-wrapped fuel bundle were analyzed, but the present study additionally included heat transfer analysis through conjugate heat transfer. The main purpose of the study was to benchmark the experimental data of the PLANDTL 37-pin wire-wrapped fuel bundle to investigate the heat transfer phenomena. In addition, the aim was to verify the accuracy of the RANS-based CFD analysis method using the STAR-CCM+ simulation software in comparison with the experimental data. The grid used for verification was an innovative grid system consisting of hexahedra using Fortran-based code. The development of the RANS-based CFD methodology included grid sensitivity analysis, turbulence model sensitivity analysis, and turbulent Prandtl number sensitivity analysis. Information on the temperature, mass flow rate, and area of the CFD results for each subchannel was provided for the top of the heated section and is expected to serve as a reference for future studies aiming to perform the validation and verification of a PLANDTL facility. In addition, the dependence of the peak temperature on the azimuth angle of each pin was analyzed.

97 MATHEMATICS AND COMPUTING↗

Improved Double Pulse Test for Accurate Dynamic Characterization of Medium Voltage SiC Devices

This article presents an improved double pulse test (DPT) for accurate dynamic characterization of the medium voltage (MV) silicon carbide device. The difference between low voltage (LV) and MV DPT setup grounding is first introduced, which results in different measurement considerations. Then, parasitic capacitances in the DPT and their impact on the DPT are discussed considering different grounding points and device connections. Approaches are proposed to minimize the impact of parasitic capacitances on DPT results. In addition, the impact of switching V-I timing alignment on the testing results is discussed, compared to that in the LV DPT; a V-I alignment approach is introduced for the MV DPT. A 10 kV/20 A SiC mosfet -based DPT is taken as an example of the improved DPT, and test results show that it can minimize the impact from parasitic and improve the accuracy of the device switching loss estimation.

42 ENGINEERING↗

The results of a limited study of approaches to the design, fabrication, and testing of a dynamic model of the NASA IOC space station. Executive summary

The options for the design, construction, and testing of a dynamic model of the space station were evaluated. Since the definition of the space station structure is still evolving, the Initial Operating Capacity (IOC) reference configuration was used as the general guideline. The results of the studies treat: general considerations of the need for and use of a dynamic model; factors which deal with the model design and construction; and a proposed system for supporting the dynamic model in the planned Large Spacecraft Laboratory.

Brooks, George W.↗