Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Assisted migration in a warmer and drier climate: less climate buffering capacity, less facilitation and more fires at temperate latitudes?

Assisted tree migration has been proposed as a conceptual solution to mitigate lags in biotic responses to anthropogenic climate change. The rationale behind this concept is that tree species currently growing under warmer and drier climates will be more resistant and resilient to the new climatic conditions than tree species naturally growing in currently wetter and colder climates. However, we hypothesize that, by being more stress‐tolerant to warmer and drier conditions, translocated species should exhibit different functional attributes, which could induce important ecological and societal costs and overcome the desired benefits of maintaining wood production and other ecosystem services. We used principal component analysis (PCA) to analyze variation in seven traits of 106 tree and tall shrub species from contrasting latitudinal distributions in western North America and Europe to predict the potential functional changes of forest ecosystems due to the translocation of tree species from low to high latitudes. We show that species from both continents differed primarily by their position on the leaf economy spectrum (LES) and their size traits. Even though, in Europe, differences in LES were significantly correlated to species southern latitudinal positions, in both continents differences in size traits were significantly correlated to latitude. These results suggest that assisted migration by translocating more conservative species of shorter stature in currently cooler climates should decrease the buffering capacity of forest canopies, decrease facilitation for understory species, and increase wildfire risks, whose effects have the potential to accelerate climate warming through negative atmospheric feedback processes. As an alternative solution to assisted migration that may accelerate rather than mitigate climate change, we recommend that foresters gradually diversify the vertical structure and layering of the existing forest canopy to maintain a sustainable water cycle and energy balance between the soil, the tree and the atmosphere without increasing the wildfire risk.

Environmental Sciences & Ecology↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bike and Scoot to Transit

In this project, we developed a micromobility first-mile service for customers to access public transit. We launched this service as a pilot in the Seattle area that incentivized transit customers to bike or scoot to transit. The objective was to learn how to integrate different micromobility services and provide a unified reward program. Our pilot was called “Bike and Scoot to Transit” and ran from November 2022 to September 2023. More than a dozen locations were selected near transit hubs and light rail/train stations as preferred parking locations. Trips ending at those locations were partially funded. The pilot supported 19,226 qualified trips and distributed $73,000 in total benefits for the participants of the pilot. This dataset was collected from our pilot, which includes the following: - Monthly data: Monthly trip and funding summaries. - Data summary: Data broken down based on the micromobility service provider and equipment. - Trip data: List of all trips recorded during the pilot. - Pricing models: Fees charged by micromobility service providers. ![bike to transit](bike-transit.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

One hundred priority questions for advancing seagrass conservation in Europe

Societal Impact Statement Seagrass ecosystems are of fundamental importance to our planet and wellbeing. Seagrasses are marine flowering plants, which engineer ecosystems that provide a multitude of ecosystem services, for example, blue foods and carbon sequestration. Seagrass ecosystems have largely been degraded across much of their global range. There is now increasing interest in the conservation and restoration of these systems, particularly in the context of the climate emergency and the biodiversity crisis. The collation of 100 questions from experts across Europe could, if answered, improve our ability to conserve and restore these systems by facilitating a fundamental shift in the success of such work. Summary Seagrass meadows provide numerous ecosystem services including biodiversity, coastal protection, and carbon sequestration. In Europe, seagrasses can be found in shallow sheltered waters along coastlines, in estuaries & lagoons, and around islands, but their distribution has declined. Factors such as poor water quality, coastal modification, mechanical damage, overfishing, land‐sea interactions, climate change and disease have reduced the coverage of Europe’s seagrasses necessitating their recovery. Research, monitoring and conservation efforts on seagrass ecosystems in Europe are mostly uncoordinated and biased towards certain species and regions, resulting in inadequate delivery of critical information for their management. Here, we aim to identify the 100 priority questions, that if addressed would strongly advance seagrass monitoring, research and conservation in Europe. Using a Delphi method, researchers, practitioners, and policymakers with seagrass experience from across Europe and with diverse seagrass expertise participated in the process that involved the formulation of research questions, a voting process and an online workshop to identify the final list of the 100 questions. The final list of questions covers areas across nine themes: Biodiversity & Ecology; Ecosystem services; Blue carbon; Fishery support; Drivers, Threats, Resilience & Response; Monitoring & Assessment; Conservation & Restoration; Governance, Policy & Management; and Communication. Answering these questions will fill current knowledge gaps and place European seagrass onto a positive trajectory of recovery.

Nordlund, Lina Mtwana↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

Thermomechanical Stress and Creep-Fatigue Analysis of a High-Temperature Prototype Receiver for Heating Particles

This work presents a three-dimensional (3D) thermomechanical model of a prototype-scale enclosed light trapping solar receiver for heating particles. Results of the thermoelastic model are used to estimate receiver lifetime under maximum flux conditions. A computational fluid dynamics (CFD) model is first developed to predict the temperature fields in a multi-panel assembly under steady operating conditions. Solar flux distributions on the receiver are obtained from the software package SolTrace and applied to the 3D thermal model. The subsequent particle heating is captured through a simplified 1D energy balance. Panel reradiation is considered through a surface-to-surface radiation model and natural convection loss to the surrounding air is captured in a representative fluid domain surrounding the receiver. The resulting temperature fields from the CFD analysis are used as inputs for a thermoelastic mechanical model with representative boundary conditions. With the resultant temperature and stress fields, a creep-fatigue damage and lifetime analysis is performed using the linear damage accumulation (LDA) theory. The Manson-Coffin formula and Larson Miller correlation are used to calculate the fatigue and creep, respectively. A maximum damage (corresponding to a 30-year service life) is defined for design assessment. The model was first developed and verified in detail by comparing with published results in the literature (temperature and stress profiles and distributions, and creep/fatigue damage fractions) for tubular solar receivers with supercritical carbon dioxide as the working fluid. It was then implemented to model a planar-cavity receiver with various design parameters. Specifically, three different design geometries are considered, and the results show that a maximum temperature of approximately 1200 K could be reached for each design with the given incident solar flux, with the main difference being the distribution of these temperatures. Preliminary resulting stresses for the small-scale prototype without design optimization vary from 20 MPa to 250 MPa for each design, with the maximum stresses occurring on the front face and concave geometry on the side of the panel. In future work, the developed methodology shown here will be applied to analyze a full-scale (50-150 MWth) receiver.

concentrated solar power↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aggregated Distributed Energy Resources in 2024: The Fundamentals

This report builds upon existing literature and leading examples of ADER pricing and programs in practice to equip commissioners and staff at Public Utilities Commissions (PUCs) and State Energy Offices with the fundamentals of ADER grid services, valuation options, and approaches to compensation. Examples, active debates, and opportunities for further reading are highlighted throughout the document for readers to explore. This report does not seek to outline a specific objective for ADERs in the electricity system nor does it recommend any specific policies for ADERs—it seeks to provide helpful information to inform policymakers’ own ADER strategies and priorities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission-Distribution Dynamic Co-Simulation of Electric Vehicles Providing Grid Frequency Response: Preprint

This paper investigates the impacts of electric vehicles (EVs) on power system frequency regulation based on an open-source transmission-and-distribution (T&D) dynamic co-simulation framework. The development of a EV dynamic model based on appropriate WECC dynamic model is introduced first, then the T&D dynamic co-simulation platform is described. The advantage of the overall platform is that DERs such as distributed photovoltaic (DPV) and EV are modeled explicitly in both transmission and distribution simulators for frequency dynamics and voltage, respectively. In the case studies, EVs frequency responses (i.e., primary and/or secondary) are simulated after the system is exposed to N-1 contingency such as a generation trip. Various EV frequency regulation participation strategies are investigated as well to study their impacts on system frequency response. The studies shows that EVs have potential capability to provide effective frequency regulation services.

electric vehicle↗

Infrastructure inequality is a characteristic of urbanization

Urbanization can challenge sustainable development if it produces unequal outcomes. Infrastructure is an important urbanization dimension, providing services to support diverse urban activities. However, it can lock in unequal outcomes due to its durable nature. This paper studies inequalities in infrastructure distributions to derive insights into the structure and characteristics of unequal outcomes associated with urbanization. We analyzed infrastructure inequalities in two emerging economies in the Global South: India and South Africa. We developed and applied an inequality measure to understand the structure of inequality in infrastructure provisioning (based on census data) and infrastructure availability (based on satellite nighttime lights [NTLs] data). Consistent with differences in economic inequality, results show greater inequalities in South Africa than in India and greater urban inequalities than rural inequalities. Nevertheless, inequalities in urban infrastructure provisioning and infrastructure availability increase from finer to coarser spatial scales. NTL-based inequality measurements additionally show that inequalities are more concentrated at coarse spatial scales in India than in South Africa. Finally, results show that urban inequalities in infrastructure provisioning covary with urbanization levels conceptualized as a multidimensional phenomenon, including demographic, economic, and infrastructural dimensions. Similarly, inequalities in urban infrastructure availability increase monotonically with infrastructure development levels and urban population size. Together, these findings underscore infrastructure inequalities as a feature of urbanization and suggest that understanding urban inequalities requires applying an inequality lens to urbanization.

54 ENVIRONMENTAL SCIENCES↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Priority-enabled Load Balancing for Dispersed Computing

Opportunistic managed access to local in-network compute resources can improve the performance of distributed applications and reduce the dependence on shared network resources. Instead of backhauling application data to a centralized cloud data center for processing, networked services may be adaptively and continuously dispersed into shared compute resources that are closer to the source of need. While this approach has several benefits, support for mission-aware access to computation is often an afterthought, and is implemented as a brittle extension over traditional load-balancer solutions.In this work, we investigate the design of two priority-aware resource allocation strategies and two load-balancing dispatching strategies as first class citizens in an open-source dispersed computing middleware. We present a control theoretic analysis of these load-balancing primitives to identify weaknesses and strengths in our design, and recommend future directions. In parallel, we prototype two priority-aware allocation algorithms to validate our priority predictions. In initial experiments our prototype shows substantial gains in processing prioritized load. Finally, we make our source-code and experimental configurations open source.

Paulos, Aaron↗

Optimal Microgrid Networking for Maximal Load Delivery in Phase Unbalanced Distribution Grids: A Declarative Modeling Approach

Over the last several years, microgrids have increasingly become a part of the discussion about technologies that can improve the resilience of modern electrical grids. During extreme situations, microgrids have the capability to provide electrical service to customers within their boundaries when they would otherwise experience disruptions, and, when networked together, provide services to additional customers outside the microgrid boundaries. As a result, these technologies have motivated the community to develop new approaches for leveraging networked microgrid capabilities that utilize increasing levels of modeling sophistication. This has yielded a new challenge, where it has becoming increasingly difficult to fully quantify and evaluate the contribution of such detail. Here, the primary innovation presented in this paper is a method to standardize the approach to quantifying and evaluating these contributions via a declarative modeling approach that supports seamless mix-and-match of representations to ease comparison of modeling approaches and develop comprehensive understandings of how new contributions improve solutions to this problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variational data augmentation for a learning-based granular predictive model of power outages

As the trend in climate change continues, extreme weather events are expected to occur with increasing frequency and severity and pose a significant threat to the electric power infrastructure. Regardless of the efforts a utility puts towards hardening the grid, storm-induced damage to the utility assets such as cables and distributed energy resources (DERs) that are particularly vulnerable to such events is unavoidable. Access to a highly granular, in space and time, outage forecasting tool with long lead times (i.e., days ahead) will enhance the efficiency of service restoration efforts. Here, in this study, we propose to develop and implement a multi-model framework as an operational tool based on a granular and multi-day outage forecasting model using operational numerical weather prediction model forecasts and detailed component outage information. An innovative two-layered recurrent neural network, i.e., a long-short-term-memory (LSTM)-based variational autoencoder (VAE) framework and a sliding window are used to address the uneven distribution of different types of weather events and make better use of the time-series data. Case studies are performed to demonstrate the performance of the new framework.

54 ENVIRONMENTAL SCIENCES↗

CPS Testbed Architectures for WAMPAC using Industrial Substation and Control Center Platforms and Attack-Defense Evaluation

Advanced persistent threats and cyberattacks can impact wide-area monitoring, protection, and control (WAMPAC) system operation. Many cyber-physical system (CPS) testbeds have been developed for attack-defense experimentation and attack-resiliency tools evaluation for WAMPAC, but they are limited to a simulation-and-emulation based environment. This paper presents a quasi-realistic CPS attack-defense testbed-based framework for WAMPAC applications using the industrial substation and control center platforms such as eTerra integrated with the hardware-in-the-loop CPS smart grid testbed available at Iowa State University. The proposed framework includes various combinations of industry-grade substation and control center platforms, communication topologies, real-time digital simulators, and a novel cyber-physical distributed intrusion-and-anomaly detection system (D-IADS) for WAMPAC applications. The D-IADS includes a master at the control center and geographically distributed sensor devices at each substation. Each D-IADS sensor deployed at a substation or control center network monitors ingress and egress traffic, detect intrusions, and dispatch alerts to the D-IADS master. The D-IADS master centrally monitors and analyze the alerts and controls D-IADS sensors. We considered an EMP60 synthetic CPS grid as a case study to demonstrate the framework and proposed D-IADS for WAMPAC applications against cyberattack vectors such as Man-in-the-Middle DNP3 attack, denial-of-service, and data-integrity attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗