Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Search for supermassive magnetic monopoles using mica crystals

The survival of the Galactic magnetic field almost certainly sets an astrophysical upper bound of approx. 10 to the minus 15th power cm(-2) sr(-1) s(-1) on the flux of monopoles. To improve significantly upon this Parker limit with direct, real time searches would require a detector area of approx. 10,000 square meters and a collection time of years. Several such searches are being contemplated. A novel alternative scheme using large mica crystals capable of recording and storing tracks of slow monopoles over a time scale of approx. 10 to the 9th power years was proposed.

Price, P. B.↗

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record↗

Slot-line end-fire antennas for THz frequencies

Tapered slot-line endfire antennas, of BLTSA type, have been fabricated on 1.7 micron thin SiO2/Si3N4 (epsilon (sub r) = 4.5) dielectric membranes. The antenna patterns, in the E-, H-, D- and D-cross planes, were measured at 270, 348, 370, and 802 GHz using bismuth micro bolometer detectors. The antennas have approximately 12 dB directivity, and the -10 dB beam widths are 50 and 55 degrees in the E- and H-planes at 348 GHz, respectively. The measurements at millimeter/submillimeter wavelengths compare well with scale measurements at 45 GHz as well as with theoretical predictions. The overall results are encouraging and show that slot-line antennas can be fabricated for use at THz frequencies. Furthermore, it is shown that the very thin SiO2/Si3N4 membranes are strong enough to be used in practical applications.

Ekstroem, H.↗

Direct 75 milliarcsecond images from the Multiple Mirror Telescope with adaptive optics

We report results from an adaptive optics system designed to provide imaging at the diffraction limit of resolution in the near-infrared at the Multiple Mirror Telescope (MMT). For the present experiment, the aperture consisted of five of the six primary mirrors of the MMT, operating as a coherently phased array. The largest components of the atmospherically induced wave-front aberration are the fluctuations in mean phase between the segments. These errors were derived in real time from the Fourier transform of short-exposure stellar images at 2.2 microns and corrected at an image of the telescope pupil with piston motion from a segmented adaptive mirror. At a correction rate of 43 Hz, this level of adaptive control resulted in an integrated image with a clear diffraction-limited component of 0.075 arcsec FWHM. This stabilized component is present directly in the light arriving at the detector and is not the result of postprocessing. We discuss future improvements to our adaptive wave-front control and its application to astronomical observations.

Lloyd-Hart, M.↗

Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants

A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.

Thornton, Michael G.↗

Quasi‐2D Perovskite Crystalline Layers for Printable Direct Conversion X‐Ray Imaging

Abstract Polycrystalline perovskite film‐based X‐ray detector is an appealing technology for assembling large scale imager by printing methods. However, thick crystalline layer without trap and solvent residual is challenging to fabricate. Here, the authors report a solution method to produce high quality quasi‐2D perovskite crystalline layers and detectors that are suitable for X‐ray imaging. By introducing n ‐butylamine iodide into methylammonium lead iodide precursor and coating at elevated temperatures, compact and crystalline layers with exceptional uniformity are obtained on both rigid and flexible substrates. Photodiodes built with the quasi‐2D layers exhibit a low dark current and stable operation under constant electrical field over 96 h in dark, and over 15 h under X‐ray irradiation. The detector responds sensitively under X‐ray, delivering a high sensitivity of 1214 µC Gy air −1 cm −2 and a sensitivity gain is observed when operated under higher fields. Finally, high resolution images are demonstrated using a single pixel device that can resolve 80–200 µm features. This work paves the path for printable direct conversion X‐ray imager development.

36 MATERIALS SCIENCE↗

Wide Band Gap Radiation Detectors for Deep Space Science

Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.

ion detectors↗

Analysis of simulated measurements of earth emitted radiation using geometric shape factors, and some results from analysis of ESSA 7 and Nimbus 6 data

In the reported study, simulated measurements of earth radiation with wide field-of-view (WFOV) radiometers are reduced to earth fluxes through geometric shape factors. Estimates of emitted flux for global and zonal scales and for regions smaller than the detector field-of-view are compared to fluxes derived directly from a model. Geometric shape factors are used to estimate global, zonal, and regional averages of earth-emitted flux from measurements with WFOV detectors on the ESSA 7 satellite and the Nimbus 6 satellite. Zonal and global averages of emitted flux for each of the 3-month periods of ESSA 7 data are shown in a graph. Another graph shows zonal and global averages of emitted flux for August 1975 obtained with the aid of Nimbus 6. The data are compared to values reported by Green and Smith (1977) who used a spherical harmonic solution.

Weaver, W. L.↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Few arc-minute and keV resolutions with the TIGRE Compton telescope

The tracking and imaging gamma ray experiment (TIGRE) Compton telescope concept can provide an angular resolution of a few arcmin, an energy resolution of a few keV and high sensitivity, while providing the wide field of view necessary for surveying and monitoring observations. Silicon and CdZnTe strip detectors are used to detect Compton pair events and determine their incident directions and energies. Above 400 keV, Compton recoil electrons are tracked through successive layers of thin silicon strip detectors. Compton scattered photons are detected with CdZnTe strip detectors. Pair electrons and positrons are tracked to provide high sensitivity observations in the 10 to 100 MeV range. Polarization studies are performed with large angle Compton scatter events. The TIGRE concept and development status are described.

Zych, A.↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

SOHO Ultraviolet Coronagraph Spectrometer (UVCS) Mission Operations and Data Analysis

The scientific goal of UVCS is to obtain detailed empirical descriptions of the extended solar corona as it evolves over the solar cycle and to use these descriptions to identify and understand the physical processes responsible for coronal heating, solar wind acceleration, coronal mass ejections (CMEs), and the phenomena that establish the plasma properties of the solar wind as measured by "in situ" solar wind instruments. This report covers the period from 15 February 2003 to 14 April 2004. During that time, UVCS observations have consisted of three types: 1) standard synoptic observations comprising, primarily, the H I Lyalpha line profile and the 0 VI 103.2 and 103.7 nm intensity over a range of heights from 1.5 to about 3.0 solar radii and covering 360 degrees about the Sun, 2) sit and stare observations for major flare watches, and 3) special observations designed by the UVCS Lead Observer of the Week for a specific scientific purpose. The special observations are often coordinated with those of other space-based and ground-based instruments and they often are part of SOHO joint observation programs and campaigns. Lead observers have included UVCS Co-Investigators, scientists from the solar physics community and several graduate and undergraduate level students. UVCS has continued to achieve its purpose of using powerful spectroscopic diagnostic techniques to obtain a much more detailed description of coronal structures and dynamic phenomena than existed before the SOHO mission. The new descriptions of coronal mass ejections (CMEs) and coronal structures from UVCS have inspired a large number of theoretical studies aimed at identifying the physical processes responsible for CMEs and solar wind acceleration in coronal holes and streamers. UVCS has proven to be a very stable instrument. Stellar observations have demonstrated its radiometric stability. UVCS has not required any flight software modifications and all mechanisms are operational. The UVCS 0 VI Channel with its redundant optical path for wavelengths near H I Lyalpha is capable of observing the entire UVCS wavelength range. The regions of the detector currently being used require different grating angles for direct OVI observations and redundant path H I Lyalpha observations, and so those can no longer be observed simultaneously. Since December 1998, the 0 VI Channel has been used for all UVCS observations. Although the H I Lyalpha Channel and detector are still operational, increases in the dark count up to about 5x10(exp 4) counts/sec/pixel and an increase in high voltage current to within a factor of two of the maximum used in the laboratory before flight led to the decision to not use that detector after 1998. The visible light channel functioned nominally during the reporting period. UVCS data, data analysis software, calibration files and the mission log are available from the SOHO archive and SAO. All UVCS data are now available within three months of the observations to scientists and the general public via the SOHO Data Archive and SAO. UVCS has resulted in 33 scientific papers in 2003. There were numerous presentations at scientific meetings. UVCS Education and Public Outreach activities involved nine members of the UVCS team. During the reporting period, there were over a dozen events directed at students and teachers, museum audiences, and public audiences via the mass media, internet and educational literature.

Gurman, Joseph↗

Preliminary test data using the MOS DRO with Si:In detector material

The initial testing performed on the Hughes Metal Oxide Semiconductor Direct Readout (MOS DRO) with a Si:In extrinsic infrared array is described. The testing to date was of a screening nature and the results are primarily qualitative rather than quantitative. At a later date the performance optimization phase will be initiated. An encouraging result is that this response is strongly dependent on the detector temperature, to the extent that thermal transients introduced during the chip readout will affect the performance. A responsivity of 1 A/W at 2.2 microns with a bias of 15 volts, which is well below what is optimum bias, was obtained.

Fowler, A. M.↗

DISCO - A Wide Field Heliospheric Imager

DISCO (Direct Imaging of the Solar Corona) is a concept for a compact, side-looking heliospheric imager that captures a wide field of view with a single camera and detector. The first optical element of DISCO is a convex reflector that tends to direct stray light away from the lenses and detector. The angular resolution of the system varies over the field of view and is higher at low elongation angeles where it is most needed to resolve the structure of coronal mass ejections and corotating interaction regions.

Rabin, Douglas↗

GaN-Based Detector Enabling Technology for Next Generation Ultraviolet Planetary Missions

The ternary alloy AlN-GaN-InN system provides several distinct advantages for the development of UV detectors for future planetary missions. First, (InN), (GaN) and (AlN) have direct bandgaps 0.8, 3.4 and 6.2 eV, respectively, with corresponding wavelength cutoffs of 1550 nm, 365 nm and 200 nm. Since they are miscible with each other, these nitrides form complete series of indium gallium nitride (In(sub l-x)Ga(sub x)N) and aluminum gallium nitride (Al(sub l-x)Ga(sub x)N) alloys thus allowing the development of detectors with a wavelength cut-off anywhere in this range. For the 2S0-365 nm spectral wavelength range AlGaN detectors can be designed to give a 1000x solar radiation rejection at cut-off wavelength of 325 nm, than can be achieved with Si based detectors. For tailored wavelength cut-offs in the 365-4S0 nm range, InGaN based detectors can be fabricated, which still give 20-40x better solar radiation rejection than Si based detectors. This reduced need for blocking filters greatly increases the Detective Quantum efficiency (DQE) and simplifies the instrument's optical systems. Second, the wide direct bandgap reduces the thermally generated dark current to levels allowing many observations to be performed at room temperature. Third, compared to narrow bandgap materials, wide bandgap semiconductors are significantly more radiation tolerant. Finally, with the use of an (AI, In)GaN array, the overall system cost is reduced by eliminating stringent Si CCD cooling systems. Compared to silicon, GaN based detectors have superior QE based on a direct bandgap and longer absorption lengths in the UV.

Aslam, S.↗

Acoustic penetration and impact detector for micrometeoroid and space debris application

The Two-Stage Acoustic Penetration and Impact Detector is a simple device for measuring the impact event time, the projectile velocity, the flight path direction and the momentum. The results of laboratory tests have shown that this detector can be used in a wide range of projectile size and velocity. According to measurement purposes the size of the detection area, the distance between the front foil and the target plate and the number of microphones as well as the evaluation procedure can easily be adjusted. The target plate area can also be replaced by another foil detector, if two penetration stages are preferred. This active detector is suitable for a variety of applications in meteoroid and space debris exploration. It can also be supplied with capture cell properties for chemical analysis of inside-deposits. Therefore, this measurement principal has been taken into consideration as a possible flight experiment for instance for a later Longer Duration Exposure Facility (LDEF) flight or future space station activities.

Kuzcera, H.↗

A Role for MST Neurons in Heading Estimation

A template model of human visual self-motion perception, which uses neurophysiologically realistic "heading detectors", is consistent with numerous human psychophysical results including the failure of humans to estimate their heading (direction of forward translation) accurately under certain visual conditions. We tested the model detectors with stimuli used by others in single-unit studies. The detectors showed emergent properties similar to those of MST neurons: (1) Sensitivity to non-preferred flow; Each detector is tuned to a specific combination of flow components and its response is systematically reduced by the addition of nonpreferred flow, and (2) Position invariance; The detectors maintain their apparent preference for particular flow components over large regions of their receptive fields. It has been argued that this latter property is incompatible with MST playing a role in heading perception. The model however demonstrates how neurons with the above response properties could still support accurate heading estimation within extrastriate cortical maps.

Stone, L. S.↗

Semiconductor crystal high resolution imager

A radiation imaging device (10). The radiation image device (10) comprises a subject radiation station (12) producing photon emissions (14), and at least one semiconductor crystal detector (16) arranged in an edge-on orientation with respect to the emitted photons (14) to directly receive the emitted photons (14) and produce a signal. The semiconductor crystal detector (16) comprises at least one anode and at least one cathode that produces the signal in response to the emitted photons (14).

Levin, Craig S.↗